Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Similar documents
Technical data sheets

Technical data sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheets

Technical Data Sheets

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

EFFEKTA Power Supplies

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Uninterruptible Power Supplies. Section BuyLog Catalog 20-1

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerValue 11/31 T kva

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 750/1000 kw With eboost Technology

POWER kva

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

3 Uninterruptible Power Systems

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

TECHNICAL DATA SHEET KVA UPS Systemss

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

LanPro 11 U. Product Description. GE Digital Energy. Uninterruptible Power Supply. LanPro UPS. Technology for the Digital World.

PowerScale TECHNICAL SPECIFICATIONS

Technical Specification SENTINEL PRO

3 Uninterruptible Power Systems

1.1 GENERAL CHARACTERISTICS

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

POWERTRONIX QUASAR 5-40 KVA

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Power+ CLASSIC. 20/30 kva, 3x208 Vac

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

PowerScale kva Technical Specifications

Liebert. FP 50Z kva

EATON 9315 UPS 200 TO 300 KVA Specifications

Uninterruptible Power Systems

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

On-line, Single Phase, Double Conversion UPS

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

SENTINEL VA

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

YOUR POWER IN SAFE HANDS. E Series UPS

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Three Phase UPS Systems Range: 10 to 500kVA

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

UPS Multi Sentry 10-20kVA

Aurora Single Phase Emergency Lighting Inverters

Uninterruptible Power Systems

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

PowerWave 33 Efficient power protection for today s IT and process-related work environments

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Industrial PFC UPS System

3 Uninterruptible Power Systems

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

MKN-DSP SERIES - THREE PHASE

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

2 Uninterruptible Power Systems

Security Plus Online Uninterruptible Power Supply

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Uninterruptible Power Systems

Inform Company Profile

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

D Series: UPS UPTO - 300KVA - Three / Three Phase

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Transcription:

GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gepowerquality.com

General data Topology VFI, on line double conversion Nominal output rating VA/W 700/630 1000/900 1500/1350 1920/1740 Overall efficiency at nominal load % >87 Heat dissipation at inverter nominal load, PF=0.9. and charged battery W 86 123 184 237 Cooling air (77-86ºF) CFM 15 21 32 41 Audible noise level at one meter db(a) < 45 db(a), load and temperature dependent Operating temperature range 32 to 104ºF (0 to +40ºC) 59-77 ºF recommended for batteries) Storage temperature range -4 to 122ºF (-20ºC to +50ºC) Relative humidity Max. 20-95% (non-condensing) Protection degree Steel-plastic / IP20 Safety UL 1778, 4 th Edition EMC FCC Part-15, Class B Surge capacity EN61000-4-5: 6kV line-line / 6kV line-earth Electrostatic discharge immunity EN 61000-4-2, 4kV contact / 15kV air discharge Transport On pallet / Tower and rack mountable Colour RAL 9005 (black) Outlet connectors NEMA 5-20R ( additional L5-20R in 2000 VA ) Inlet connectors IEC-C14 in 700-1000VA and C20 in 1500-2000VA Cooling Forced air Input converter (rectifier + power factor correction) Nominal AC input voltage 120V Input frequency range 45-66 Hz Power factor > 0.99 THDi < 6% Nominal input current (no charging, Uin = nominal) Adc 6.6 9.1 13.9 16 Inrush current None DC output voltage 2 x 210V Battery charger Battery charging characteristic AC input voltage range Constant current charging until boost voltage, then float voltage charging 60 to 140V DC output voltage Vdc 40.5 81 Output current limitation Adc 1.5 Recharge time 3 hours for 90% capacity, standard battery Battery data Battery type Sealed lead acid, VRLA Float voltage at 25 C Vdc 40.5 81 Number & rating of 12V batteries (standard version) 3*7Ah 3*9Ah 6*7Ah 6*9Ah Standard backup time at nominal resistive load min 8 8 7.2 8 End of discharging voltage (Vdc/cell) Vdc 1.66 Standard backup extensions (Table.1 for backup time) NO YES YES YES Modifications reserved Page 2/5

Output converter (inverter) Input voltage range Vdc 200-220 Nominal output power at PF=0.9 VA 700 1000 1500 1920 Nominal output power with resistive load W 630 900 1350 1740 Nominal AC output voltage Vac 120 Output voltage waveform sine wave Output voltage tolerance: - static resistive load < 1% - dynamic mean deviation over half cycle (load step 0-100-0%) < 2% - with measured non-linear load 2.5:1 < 2% - recovery time to +/-1% 2ms Overload capability (battery operation) 110% during 4 minutes, 150% during 2 seconds Short circuit current capability (app. 200ms) 2.1 times nominal current during app. 200 ms Output frequency 50/60 Hz auto selectable ( Default 60 Hz during cold start ) Output frequency tolerance ± 0.05% nominal, unless synchronized with mains Frequency tracking range ± 10% default ( ± 2% selectable ) Max. phase shift difference input-output < 1º typical ( max. 7º during tracking frequency range ) Harmonic distortion with linear load < 1% Harmonic distortion with non-linear load < 6% Power factor range 0.7 to 1 (Lag & Lead) Crest factor handling capability of non-linear load Up to 3:1 Output power derating altitude Up to 1000m no derating Above 1000m 12.5% per 1000m, max. 4000m Protection Automatic transfer to bypass (if available) In case of: - internal circuit failure - over temperature - overload / short circuit Output protected against connection to the mains Inverter bridge PWM and IGBT technology Bypass Primary Element Bypass voltage limits Frequency tracking range Slew rate Overload capability on bypass Static switch -15% to +10% of selected output voltage ± 10% default (± 2% selectable) of selected output frequency 2 Hz/sec 120% 3min. 150% 1 min Interfacing Potential free contacts (optional) Input terminals for Four change-over contacts signalling following alarms: - bypass active - mains failure - battery low - general alarm (programmable) - Remote Power Off - Battery extension pack DC connector Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 3/5

Controls, signals and alarms Front panel details On / Off Push buttons UPS ON/standby LED On Bypass LED On Battery LED Alarm LED (red) Runtime LED bar Load level LED bar Front panel Rear panel details Input thermal circuit breaker Input / Output sockets DC connector for batteries Remote External Power Off Contacts (REPO) USB interface card USB/RS232/Relay Card * SNMP Card* *option Rear panel 2000VA 1500VA 1000VA 700VA Optional features SNMP interface card An SNMP interface adapter can be placed in the SNMP slot in the rear panel of the UPS, which allows the data interface to be connected directly to an Ethernet or Web. USB/RS232/Relay Card The card is provided with an USB connector, a 9-pole sub-d connector and four potential free changeover contacts, representing: mains failure, general alarm, battery low and bypass active. Battery modules extended runtime Additional battery modules (up to 3) may be connected in parallel to in order to achieve a longer runtime. Every battery module is equipped with its DC cabling and it makes connection between modules very easy and simple. Increasing of total battery capacity will correspond to a longer recharging time. Modifications reserved Page 4/5

Table.1 Dimensions and battery run times UPS Model Backup time (min.) Total capacity (Ah) Nr. of extra battery cabinets Dimensions ( HxWxD ) Battery cabinet VH700 8 7 --- --- VH1000 VH1500 VH2000 8 9 --- 26 23 1 48 37 2 66 51 3 7 7 --- 35 21 1 63 35 2 88 49 3 8 9 --- 26 23 1 50 37 2 74 51 3 3.4x17.2x18.5 inch 87x438x470 mm 3.4x17.2x21.3 inch 87x438x540 mm Weight 60 lbs 27kg 101 lbs 46kg Shipping weight 68 lbs 31kg 110 lbs 50kg Dimensions ( HxWxD ) 3.4x17.2x18.5 inch 87x438x470 mm 3.4x17.2x21.3 inch 87x438x540 mm UPS cabinet Weight Shipping weight 35 lbs/16 kg 49 lbs/22kg 37 lbs/17kg 53 lbs/23kg 64 lbs/29kg 73 lbs/33kg 71 lbs/32kg 79 lbs/36kg UPS block diagram, protections and cable sections INPUT: MAINS POWER WITH DISTURBANCES OUTPUT: PERFECT UPS POWER BYPASS FROM MAINS RFI FILTER INPUT CONVERTER OUTPUT CONVERTER AUTOMATIC BYPASS RFI FILTER APPLIANCE OUTLETS OPTIONAL CHARGER BOOSTER ON OFF FRONT PANEL USB RJ11 EXTENSION MICRO-PROCESSOR CONTROL USB RS232 Relay (optional) UPS Model Recommended external fusing of input wiring Mains / Bypass input Cable sections input and output recommended by NEC standards Alternatively, local standards to be respected CABLE SECTIONS mm 2 AWG VH 700 15A Class B MCB 1.8 16 VH 1000 15A Class B MCB 1.8 16 VH 1500 20A Class B MCB 2.5 14 VH 2000 20A Class B MCB 2.5 14 Modifications reserved Page 5/5