Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

LEDVANCE SUPERSTAR LED Downlight Gen 2

Installation Instructions

Installation Instructions

Installation Instructions

DOWNLIGHTS DEDICATED LED DOWNLIGHTS 017. DEDICATED LED DOWNLIGHTS 035. DOWNLIGHT FITTINGS

15 DOWNLIGHTS - dedicated LED. Downlights DEDICATED LED DOWNLIGHTS DOWNLIGHT FITTINGS

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

PIL0478 ISSUE 01/ 07/16

Light Source User Guide

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Measurements are expressed in millimeters.

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

Beams Spot (15 to 21.5 ) Narrow Flood (24 to 28.5 ) Flood (38 to 39 ) Wide (60 to 65 ) Reflectors Aluminum reflectors

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

DALI 650mA LED Driver

LED 2/3/4ft T8 Tube 120V

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

LE D ECO LINE. Lighting Factory

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

650mA Phase Dimmable LED Driver

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

HIGH BAY HIGH LUMEN LED INDUSTRIAL LUMINAIRE

1000mA - 650mA Phase Dimmable LED Driver

Solid State T8 tube is the smart alternative to a

Light Source User Guide

Product highlights. Retrofit only E26 adaptor Indoor / outdoor applications. 2 installation options Surface mount

CLA IPART APPROVED PRODUCTS 2017

ROOF. design: Laura Andreini

Recessed Downlights. Zas

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Product highlights. Retrofit only E26 adaptor Indoor / outdoor applications 90+ CRI. 2 installation options Surface mount


Interior Utility Lights

Fire Rated Downlights Product Catalogue

P/N Wheeler. user manual

ECO EXT (DIMMABLE)

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

E-CORE LED TUBE GX16T-5 DATA SHEET 1 /5

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

T8 Retrofit. LED Tubes

Mania EF1 user manual

Linear Line Voltage LED Engine

CFP-LED Contractor Select Flat Panel. Installation Instructions

GC SERIES HORTICULTURAL LIGHTING SYSTEM

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

High Bay Luminaire Series

TRUET5 EXT (DIMMABLE)

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

TECTONIC LED CORP. ISO

LED Driver + Dimmer 5YEAR. 40W, 60W or 100W Constant Voltage LED Driver with Integrated Dimmer for Single Gang Box Mount FEATURES & BENEFITS

E-CORE LED LIGHT ENGINE 2 AND DALI DATA SHEET 1 / 7. Application:

LED IMPORTANT SAFETY INSTRUCTIONS

The Tracking Magnet Recessed High-tech LED lighting system for interior architecture

User Guide for Logo Projector

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

LED Pinspot 2. Snapshot. User Manual

LED Pinspot 2. Snapshot. User Manual

Installation Instructions: Eco Linear High Bay

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

GP12 TECHNICAL MANUAL

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Light is reliable LED Lamps and Luminaires

4.2. Continuous line. Recessed Linears

Sylvania 7.5' Pre-Lit Troy Fir Tree LED Color Changing and Multi Function One Plug Tree Tree ID #T1, Item # V

E-CORE PAR20 / PAR30 / PAR38 DATA SHEET 1 / 11. Application:

LED Recessed Troffer Retrofit Kit

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

LED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER

18W Round LED Slimline Emergency Light

E-CORE GLS WIDE 13W / 10,5W / 7W DATA SHEET 1 / 6. Application:

LED Indoor Lighting Product Guide

Ardito LED - A2RSF SPECIFICATION SHEET. 2-1/2" Series. Ultra-Thin Profile Round Regressed Shower Trim SPECIFICATIONS

2017 STANDARD Products Inc. All Rights Reserved. Rev. January 11, 2018.

Product Installation Instruction LED Tube Lamp Retrofit Kits

Luminaires - LED High Bay

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Low profile frame is just 0.5" thick CONFIGURATIONS

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS

Linear Line Voltage LED Engine

Transcription:

TITAN RECESSED SPOT LIGHT SKU#177010, 177011 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality MFL product. To ensure correct function and safety, please read and follow all instructions carefully before assembly, installation and use. Please keep instructions for future reference. Warranty This light fitting is covered by a 5 year warranty. The warranty is from date of purchase, not the date of installation. Please retain proof of purchase. The use of non-compatible dimmers may damage your LED light fitting and will void your warranty. Warranty will be void if there is any damage due to improper usage or modification to the fitting. Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty. Installation Requirements Before installation, check the installation location in the ceiling has access to a socket outlet which is connected to a wall light switch and dimmer. If it does not, please contact a licensed electrician to arrange installation of the socket outlet, wall light switch and dimmer before continuing. All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. If unsure, please contact a licensed electrician. Select a suitable location for installation: - The mounting point must support 2 times the weight of the fitting. - This fitting is suitable for indoor use. - Ensure the fitting is not installed in direct line of an air vent/system. - If installing a fitting in an area prone to moisture, ensure that the area is well ventilated and an appropriately rated exhaust fan is used if required. Damage or corrosion caused by moisture is not a product fault, and as such is not covered under warranty. This fitting is dimmable and has been tested at the date of publication with the dimmers listed in thespecification section. The use of a LED dimmer such as the Lucci LEDlux SKU# 290998 dimmer is highly recommended. NOTE: For the best dimming range, use with the Lucci LEDlux SKU# 290998 dimmer and adjust the variable resistor at minimum and maximum dimming positions on the dimmer during the installation. NOTE: Dimming may cause buzzing sounds or a slight flicker. There may be slight delays with the LED light start up or slight uneven light performance when more than one LED light fitting is linked together, switched ON or dimmed. This is not a product fault and as such is not covered under warranty. NOTE: Some dimmers have a minimum load of 20W. Ensure the dimmer position is on the maximum setting beforeturning on the LED light and adjust the dimmer down to your desired light level. NOTE: Testing cannot account for installation variables such as variation in mains supply voltage, cable capacitance, electrical noise, transients, surges and ripple control signals (commonly found in NSW & QLD). NOTE: The information provided is correct to the best of Beacon Lighting s knowledge at the date of publication.this fitting has an insulating ceiling type IC-4 rating. Building insulation material can safely be exposed continuously to temperatures up to 90 C may abut and cover the luminaire. (Please refer to the Clearance Information section and the IC-4 Rating section in this instruction manual for further details.) If loose fill insulation or thermal insulation is not fixed into position or if there are loose combustible materials (e.g. leaves or combustible materials stored in the roof space), a barrier or guard is required as per the Clearance Information section in this instruction manual. The LED driver must be placed at least 100mm away from the LED module to allow for cooling. 1 P a g e p u b l i s h e d o n 0 2 2017v1.0

The LED driver can be placed under the insulation. (Please refer to the Clearance Information section in this instruction manual for further details.) The LED module is only suitable for use with HEPLED Driver model#:lmtc15w300-z The fitting must not be used if the diffuser on the LED module has been damaged or cracked. Take care not to pull any electrical wires during unpacking as this may damage the connection. Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement. Check whether the fitting has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work. Installation Directions 1. Remove all packaging material from the product and be careful not to throw away accessories that may be hidden within the packaging material. NOTE: Before installation, plug the fitting into a socket outlet to ensure the LED fitting is working correctly. 2. Cut an installation hole of Ø 80mm into the ceiling. Fig.1 3. Connect the fitting plug to the socket outlet.press the springs in towards lamp body and put the LED module up through the cut-out hole and into the ceiling.fig.2 4. Ensure all the clearance values are maintained during and after installation ofthe LED module, LED driver, thermal insulation, loose fill insulation, loose combustible materials and any structural members. Please refer to the Clearance Information section and the IC-4 section in this instruction manual for further details. 5. Hold the frame (A) to pullthe lamp body (B) out from the frame. Rotate and tilt the lamp body to your preferred lighting angle. Do not exceedthe maximum angle show infig.3 6. After the installation, switch on the fitting to test and enjoy your new lighting product. 7. To change the reflector (D), pull out the inner cylinder (A) and fixed ring (B), remove the diffuser (C) and the reflector (D). Reposition the reflector (F), diffuser(c), fixed ring (B) and your preferred colour inner cylinder (A, G or H - included). Fig.4 2 P a g e p u b l i s h e d o n 0 2 2017v 1.0

Clearance Information AS/NZS 3000 Wiring Rules LOCATION DISTANCE DESCRIPTION A B C D 50 mm (Minimum) 50 mm (Minimum) 0 mm (Abutted) 100mm Clearance between the top of the recessed luminaireand any combustible materials, building elements or objects above it. Clearance between the side of the recessed luminaireand any combustible materials, building elements or objects. Insulation can be abutted against the side of recessed luminaire and covered as per IC-4 Rating. See IC-4 Rating section for more details. Auxiliary equipment/driver/transformer must be placed 100mm away from the luminaire.it can be placed under the thermal insulation and covered. IC Rating AS/NZS 60598.2.2 : 2016 1. A closed luminaire that allows building insulation to come into contact with its sides and to cover it. 2. Type IC-4 recessed luminaire can be used together with building insulation that can safely beexposed continuously to temperatures up to 90 C may abut and cover the luminaire; 3. The declared IC-4 rating is based on the default testing ambient temperatures 25 C according to thestandard. 4. The insulation material must be glasswool insulation batts type, with maximum R-value 5.0. RISK OF FIRE Required clearance from structural members and building elements SCB = 50 mm HCB = 50 mm 3 P a g e p u b l i s h e d o n 0 2 2017v 1.0

Safety tips Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning or making any adjustment to the fitting. To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power. Select a suitable location away from liquids and hazards. Ensure that the fitting does not come in contact with corrosive chemicals, etc. To clean, wipe with a damp clean cloth. Never soak the fitting with water. Troubleshooting PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Check your circuit breaker/safety switch box and turn on power to your circuit. Does not work. (New installation) Does not work. (Existing installation) Wiring loose or no power to the fitting. No power to the fitting. Unplug the fitting and test in a functional socket outlet with power. If the fitting does not switch on then contact your nearest Beacon Lighting store. If the fitting is working, have your licensed electrician check the wiring or socket outlet to the fitting. Check your circuit breaker/safety switch box and turn on power to your circuit. Contact your nearest Beacon Lighting store. Flickers when dimming. (New installation) Flickers when dimming. (Existing installation) Buzzing sound. Uneven light start up. Non-compatible dimmer used. Some dimmers have a variable loading adjustment function. eg. Lucci LEDlux SKU# 290998 dimmer. This may not have been adjusted during the installation of the dimmer. Dimmer position on low. Non-compatible dimmer used. Dimmer position on low when switched on. Check the dimmer used. Ensure the dimmer used is on the list of compatible dimmers in this manual. The variable resistor needs to be adjusted to suit the fitting load to reduce the flickering. Ensure the dimmer position is on the maximum setting before turning on the fitting and adjust the dimmer down to your desired light level. Check the dimmer used. Ensure the dimmer used is on the list of compatible dimmers in this manual. Ensure the dimmer position is on the maximum setting before turning on the fitting and adjust the dimmer down to your desired light level. 4 P a g e p u b l i s h e d o n 0 2 2017v 1.0

Specifications SKU # 177010 177011 Colour White Black Rated Voltage INPUT: 220-240V~ 50Hz, OUPUT: 26-43VDC, 0.3A, constant current, Rated Wattage 14W LEDSpecs CREE LED, 3000K, 650 initial lumens Dimmer Information Weight Cut-out Size IP Rating Highly Recommended Dimmers Lucci LEDlux SKU# 290998 Compatible Dimmers LUMEX Load Smart LT1D450LS; DIGINET LED Smart MEDM; Clipsal 31E2RUDM, 32E450TM, 32E450UDM, 31E2PUDM and 32ELEDM; HPM: Cat. 400T 0.7kg Φ80mm IP20 Dimensions Serviceable Parts LED Driver Model # W: Max.145mm x H: Max. 295mm LED module and LED driver are both serviceable. LMTC15W300-Z 5 P a g e p u b l i s h e d o n 0 2 2017v 1.0