Portable Metal Detectors By: MODEL P-4000 MANUAL PORTABLE

Similar documents
Houston Office Corpus Christi Branch Dallas Branch 248 McCarty Dr Westway 4770 Gretna P.O. Box P.O. Box 5036 Dallas, TX 75207

Uninterruptible Power System

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

Combustible Gas Detector

MODEL 901 OPERATING INSTRUCTIONS

PARTS AND SERVICE MANUAL

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Troubleshooting Guide: 255 LED Light

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

Troubleshooting Guide for N1225-1/N1237-1/N Alternators

CGD8800X CGD8800X220 Combustible Gas Detector

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Installation and User Manual. with RAIN SENSOR.

OVERHEAD CONSOLE SYSTEMS

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE BATTERY HYDRAULIC POWERPACK HAB1101

IMPORTANT Read and understand instruction booklet before using scanner. Always test scanner for proper operation before each use.

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

PRODUCT MANUAL Gecko Wireless One Zone LED Dimmer and Receiver

N1387 Series Troubleshooting Guide for N Alternators

Setup and Programming Manual

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

ALU-29CF Portable Light NSN:

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

9.2, 9.2s, 9.20, 9.20s Treadmill

LESTRONIC II BATTERY CHARGER MODEL 07210

TALON 22 WHEEL & TALON X-TREME 38 WHEEL TPMS, UP to 188 PSI PRESSURE AND TEMPERATURE WITH CAP OR FEEDTHRU SENSORS

INSTALLATION INSTRUCTIONS

Portable Lighting Equipment Operating Instructions Table of Contents

Uninterruptible Power System

PY600AC Sliding Gate Opener User Manual

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

To ensure proper installation, digital pictures with contact information to before startup.

INSTALLATION GUIDES OUTDOOR LIVING

RATE CONTROLLED TORQUE WRENCH TESTER

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

!" # 0*.!0&!&1* &23# 0

Uninterruptible Power System

User s Manual. Automatic Switch-Mode Battery Charger

Installation Instructions

BROMAN MODEL 210 CONTACT RESISTANCE TEST SET SERIES 5

I1 7.5 Pre-Lit Clear Christmas Tree

WARNING ATTENTION. Please read this information carefully before operating your safe.

7.0 Aspen Pine SYLVANIA Power-Lit TM M5 Warm White LED Pre-Lighted Tree V

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

PowerMax. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.

Peristaltic Pump Operating Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS. Applications: 2005-Current Ford Excursion 2005-Current Ford F250, F-350, F-450 & F-550 Super Duty Pickups.

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Circus Playset CAUTION ELECTRIC TOY

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

REX8+ COVERT MAGMOUNT TRACKING UNIT

Musical Surroundings Presents:

USER MANUAL. Your ZINGO DRIFTA 360 warranty must be registered online within 7 days of purchase.

VERT 1 VERTICAL TAKE OFF / LANDING RC PLANE

ATD-5921 RECHARGEABLE 12 VOLT 18 AMP/HOUR JUMP START OWNERS MANUAL

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

500 Series Troubleshooting Guide for C520 Alternators

ALTERNATOR REQUESTED INFORMATION. Vehicles With Dual Generator [ Engine Mount - LH ] 2007 Ford Pickup 6.0L Eng F350 Super Duty

RK Standby Battery Operator s Manual

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

CI 3000 Coil Inserter

SECTION Multifunction Electronic Modules

Towing and Road Service Guide For the 2003 Saab 9.3 Sedan. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

Sliding Gate Operator User's Manual

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

ASSEMBLY INSTRUCTIONS

OVERHEAD CONSOLE 8C - 1 OVERHEAD CONSOLE CONTENTS

OVERHEAD CONSOLE SYSTEMS

Safe-T-element Installation Instructions

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

TCM & MAT Data Logger Battery Replacement Instructions

Uninterruptible Power System

" Ird. Portable Power 750. Jump Starter and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

Troubleshooting Guide: 355 Lights (24V)

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

APOLLO Gate Operators, Inc.

MODEL No s: PP3, PP3K

Service and Parts Manual

GENESIS Electronic Brake Controller Hayes Brake Controller Company - P/N 81790

Three Function Remote Control System with Alarm (Model RCA-3)

Troubleshooting Guide: 355 Lights (12V)

DriveRight VSS Installation Guide

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

CABINET REEL OPERATING INSTRUCTIONS

The above explanation leaves out a few details, which may frustrate a user. Here are some instructions with pictures to help you be successful.

Model APS-25CH Installation Manual

Transcription:

MODEL P-4000 PORTABLE METAL DETECTOR MODEL P-4000 MANUAL PORTABLE

All solid state circuitry. Factory direct repair service. Two year warranty RENS Metal Detectors reserves the right to make changes in specifications and prices at any time without prior notice Spare Fuse 9525 SW Commerce Circle, Wilsonville, OR 97070 Phone: 503.222.9992 / 800.367.9992 Fax: 503.222.0073 Email: RENS@cnxsind.com www.cnxsind.com

INTRODUCTION Congratulations! You re the owner or operator of a P-4000 Portable Metal Detector. Please read this manual carefully and completely. If you have any questions please feel free to contact our Sales or Service Department at 800-367-9992. CONTENTS I. ASSEMBLY II. BATTERY CHECK III. OPERATION OF UNIT Environment Indications of Metal Detection To Reset the Unit Daily Operation Setup Operation in a Noisy Environment Temperature Changes Suggested Method for Scanning Logs Scanning Standing Timber IV. SPECIFICATIONS Sensitivity V. MAINTENANCE / SERVICE (In House) Recharging the Battery Battery Pack Replacement

I. ASSEMBLY 1. Assemble the 3 piece adjustable handle; make sure the button snaps into one of the holes. To change length, depress the button and twist handle. Snap button into new hole. 2. Connect coil lead to control box. It is extremely important this is done correctly: the female coil connector has a channel that must match up with the ridge on the male connector on the control box. 3. Adjust D-Handle and Control Box to comfortable position. NOTE: The large loop in the search coil lead (Shown in Picture) must be maintained. This minimizes damage to the cable during frequent adjustments of the search head position. ~ 1 ~

II. BATTERY CHECK The unit was checked out and completely operational when sent from the factory. Transit time and storage may degrade the battery charge. If this is the case, the battery should be topped off before use. To check battery charge: turn MODE switch to BATT position. If the needle on the meter is high in the GREEN area battery is charged; when the needle drops close to or is in the red area, it needs to be recharged. Directions to recharge the battery are in section V (MAINTENANCE / SERVICE, paragraph A). ~ 2 ~

III. OPERATION OF UNIT After the satisfactory battery check: a. Turn MODE switch from BATT to RUN b. Position detector in start position so magnetic field can align itself correctly. c. The meter needle will move to midscale after two full scale deflections within about 4-6 seconds. d. The unit will sound for a few seconds as it warms up and creates a magnetic field. e. The POWER lamp will switch from RED to GREEN and the sound will stop* f. The unit will be ready to operate in about 2-3 more seconds. *Under some extreme temperature change conditions the sound may continue as intermittent grunts for another minute or two. NOTE: Random movement of metal detector will cause the detector s magnetic field to scramble causing the unit to trip. If the unit is false tripping due to a scrambled magnetic field, turn it off and begin start-up process as stated previously. ~ 3 ~

ENVIRONMENT SCAN IN A METAL FREE ENVIRONMENT Remember that a metal detector will not only detect metal in the log, or lumber, but in the surrounding area as well. DO NOT place logs on reinforced concrete pad or on ground surfaces containing buried metal such as pipes. Using the P-4000, scan the area for buried or hidden metal. Once you know the area is clear of metal, begin scanning the material. ~ 4 ~

INDICATIONS OF METAL DETECTION A. If metal is being detected a sound will be heard a small piece of metal will produce a small movement of the needle and a short chirp of sound. B. Detection of a large or particularly dense metal object may be indicated by the power indicator light turning RED, meter needle movement to the FAR RIGHT and a CONSTANT ALARM sound. HOWEVER: Check that this is not a false indication. Turn unit away from scanning area. If unit settles down and resets itself, scan area again. If the metal detector acts in the same manner, a large metal object is being detected this is a normal reaction for the Metal Detector. If unit does not settle down, RESET by turning unit off and going through start up procedures as stated previously. TO RESET THE UNIT To RESET, turn MODE switch to OFF, wait 1 to 2 seconds, then turn MODE switch to RUN. NOTE: If the detector is set on a metal floor or near any other large piece of metal for a time while the system is in RUN mode, it will be necessary to perform a RESET action to remove the large error voltage that develops. If a RESET is not performed it will take upwards of two minutes for the unit to restore itself to proper operation. ~ 5 ~

DAILY OPERATION SETUP 1. Turn MODE switch to BATT position to observe battery charge level. 2. Adjust sound volume to comfortable level. 3. Turn MODE switch to RUN position. When LED Lamp indicates GREEN, and sound is silent, unit is ready to operate. 4. Adjust sound VOLUME as needed. OPERATION IN A NOISY ENVIRONMENT Sound level is adjustable from 0-100db. When using the unit in a noisy environment, it may be advantageous to use the supplied earphones. CAUTION: To prevent ear damage when using earphones make sure VOLUME control is fully counter-clockwise before switching unit to RUN. After unit is active, turn VOLUME control to a comfortable sound level. TEMPERATURE CHANGES The unit will automatically compensate for any long-term drift due to temperature changes. To minimize the effect of drastic fast temperature changes, store unit in a location with similar temperature as working environment. ~ 6 ~

SUGGESTED METHOD FOR SCANNING LOGS NOTE: In most cases scanning of a log cannot be done in one pass. Please follow suggested scanning method below and consult sensitivity chart in Section IV (Specifications). 1. Place search head close to the log surface and scan the entire length of the log as shown in diagram. 2. Move to other side of the log and repeat step 1. 3. Roll log over as required to expose unscanned surfaces. Scan the rest of the circumference of the log covering the complete surface of the log. This procedure will ensure that the metal detector scans the entire surface of the log 2 1 3 ~ 7 ~

SCANNING STANDING TIMBER Search Head position is easily adjustable. To rotate the Search Head for vertical scanning, hold firmly and rotate D-Handle and Control to desired position. COMMON USER PROBLEM The MODE switch is sensitive to over-torqueing. The switch wiring configuration does not allow for extra room to move in either direction beyond the three designed spots: OFF, BATT, RUN. Twisting too far will damage the unit, making it necessary to repair. NOTE: Obvious excessive torque damage to the switch wiring constitutes operator damage, and is not covered under Warranty. ~ 8 ~

IV. SPECIFICATIONS WEIGHT LENGTH POWER With Battery Pack, approximately 7.5 lbs (3.4 kg) 51.5 57 (1.31m 1.45m) Adjustable in 3 positions 17.5 Volt rechargeable Battery Pack. Unit is protected with one (1) type 3 AG 3/10 Amp Slo-Blo fuse located in battery compartment. New fully charged Battery Pack will provide approximately 10 hours of continuous use. Time to completely recharge a fully discharged Battery Pack is approximately 14 hours. ~ 9 ~

SENSITIVITY All detection distances measured from point A* Metal Type 5D Nail (finish) 8d Nail 10d Nail 16d Nail 40d Nail 50d Nail 60d Nail Distance 9 (229mm) 12 (305mm) 12.5 (318mm) 13.5 (343mm) 15 (381mm) 16.5 (419mm) 16.5 (419mm) 8 Spike 18 (457mm) Fence Staple 12 (305mm) The above items CAN NOT BE DETECTED farther away than shown in the above chart. ~ 10 ~

V. MAINTENANCE / SERVICE (In House) A. RECHARGING THE BATTERY Plug charger into 120 V wall socket. Insert charger connector into the receptacle on the rear of the P-4000 control box marked CHARGER. If the battery is fully discharged, it will take 14 or more hours to fully recharge. Unit may be left on the charger continuously when not in use. The LED light becomes BRIGHTEST when the battery is LOW. When the unit is fully charged the LED light will become DIM. B. BATTERY PACK REPLACEMENT To replace the battery pack, loosen the two screws securing the battery compartment access door located at the rear of the control instrument. Grasp battery, push on battery and lift, then pull to remove. Unplug old battery pack. Install new battery pack and close compartment door. CAUTION: Handle battery pack with caution. In the unlikely event a short develops or the battery pack is damaged it could cause excessive internal heat buildup. NOTE: Use only a RENS supplied battery charger for the rechargeable battery pack. ~ 11 ~

Metal Detectors by 9525 SW Commerce Circle, Wilsonville, OR 97070 Phone: 503.222.9992 / 800.367.9992 Fax: 503.222.0073 Email: RENS@cnxsind.com www.cnxsind.com Updated 2017