Calculite LED 7" Downlight

Similar documents
performance & comfort

Remodeler. Complete product = Frame-in kit + Light engine + Trim Order each separately. E ELV dimming 1 120V VA Version A 2 Z V

C4X4L10DL Calculite LED 4 1/2" x 4 1/2" downlight

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent square downlight 800 Lumens

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent round adjustable 800 Lumens

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent round adjustable 800 Lumens

Decorative. PS (cylindrical) Vetro Pendants

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

id + 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

id + 4.5" x 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

PRODUCT SPECIFICATIONS

id + 6" x 6" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

4DS 4.5 Downlight Square

4DR 4.5 Downlight Round

6DR 6 Downlight Round

Blank. UNV Universal voltage V V V V V V. General Distribution Narrow Medium Wide Aisle Double Asymmetric

DCD2 Recessed LED Downlight Commercial New Construction 4", 6", 8" Aperture

Linear. TruGroove recessed micro

6DS 6 Downlight Square

Linear. TruGroove recessed micro

Linear. MicroSquare gen2 suspended

TUNABLE SPECTRUM/TUNABLE WHITE

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K K. EM/10W 10-watt emergency battery [4] TrimLock.

TUNABLE SPECTRUM/TUNABLE WHITE

Linear. TruGroove Recessed

Lumination LED Luminaires LED Downlight Architectural Series DI6R - 6 Round Aperture

Linear. TruGroove recessed

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

L10 - L40: 5-3/4 L50 - L60: 6-1/ K K K F OF 1/2. 65 Open. CG Champagne gold anodize for shower. 45 Open

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K F. 65 Open. SPC Clear specular anodize for shower

LAD6 6 LED Architectural Downlight

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Lightguide D 55% Down Kit G 80% Down Kit J 100% Down Kit

2-520-T Miro XTM FEATURES

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

Lightolier Lytecaster... Inspiring Intelligent Expression Lytecaster recessed luminaires open up ever-growing lighting design opportunities.

LAD6R - Remodel 6 LED Architectural Downlight

LAD8R - Remodel 8 LED Architectural Downlight

4DR 4.5 Downlight Round

6-1/4. Adjusts from 1/2 min. to 5/8 max. Pan size: 8 1/2 x 12 9/16 SERIES TRIM TYPE ADJUSTMENT LUMENS [1] CRI CCT DISTRIBUTION.

LAD8 8 LED Architectural Downlight

Recessed Square. Downlight. BASYS with LED Light Engine BS4DLED BS4D LED. Type: Project: online Find it Fast 756. IBEW Union Made BASYS LED HOUSING

CLUSTERS PLANAR DOWNLIGHT W W W. L U M E N W E R X. C O M

LAD4 4 LED Architectural Downlight

CLUSTERS LINEAR DOWNLIGHT W W W. L U M E N W E R X. C O M

ID+ 6" x 6" trim. High ceiling downlight with a choice of beamspreads is ideal for lobbies, atriums and convention centers.

LCD4 4 LED Commercial Downlight

LCD6 6 LED Commercial Downlight

LCD8 8 LED Commercial Downlight

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) A Acrylic Diffuser

Example: RBX15L840-UNV-WT ARR22L. Family Lumens Color Temperature Voltage Finish Options Optics

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Solid (100% down) G Acrylic diffuser (75-80% down)

4DS 4.5 Downlight Square

ID+ 3.5" x 3.5" 60 cut-off reflector. 50 cut-off reflector. Less than 2.64" low profile housing available.

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Solid (100% down) G Acrylic diffuser (75-80% down)

DCD1 Recessed LED Downlight Commercial New Construction 4, 6, 8 Aperture

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) A Acrylic Diffuser

Linear. FloatPlane Suspended LED

BEAM SPREAD NR = Narrow (36 degree) WD = Wide (56 degree) WW 2 = Wall Wash. REFLECTOR FINISH SD = Semi- Diffused

P15 - P44: 5-3/4 P62: 6-1/2. SCA Sloped ceiling TrimLock K K K K TW Tunable white (80 CRI, 2700K 5000K) 65 Open

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) A Acrylic Diffuser (70-75% up) D Diffuser with 50% Down Kit

RL430-10W-120V-DIM-FL / RL407-10W-120V-DIM-FL Module LED - Elite Lighting Module LED Lighting Component

2-115-T Aqua BRO FEATURES

2LP3GA217R-33FL-UNV-1/2-EBHE-LPT835HL

avenue led features dimensional data performance Narrow 3" slot LED with frosted satin lens.

SPECFIT 8" Retrofit Downlight AD8 DIM010 UNV ADR8. Project: Part#: Type: Ex: AD8-LES-9040-DIM010-UNV-MD-ADR8-CC

Project. Comments. Prepared by

SPECFIT 6" Retrofit Downlight AD6 DIM010 UNV ADR6. Project: Part#: Type: Ex: AD6-LES-9040-DIM010-UNV-MD-ADR6-CC

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Lightguide

Output (nominal lumens) 700 lm, 1000 lm, 1300 lm, 2000 lm, 3000 lm, 4000 lm, 5000 lm. Color and color temperature

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Lightguide D 55% Down Kit G 80% Down Kit J 100% Down Kit

Linear. Chopstick wall

Avenue B. Narrow 3" slot LED with frosted satin lens. Shielding options include corrugated or solid regressed trim or flush lens.

Recessed. EvoKit LED Retrofit Kits Gen 3

Linear. Chopstick suspended

Project name. Qty. Output (nominal lumens) Colour and colour temperature. Optics (nominal distribution) Narrow spot 10, Narrow 20, Medium 40

RL530-12W-120V-DIM-FL / RL507-12W-120V-DIM-FL Module LED - Elite Lighting Module LED Lighting Component

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

SAN FRANCISCO UNIFIED SCHOOL DISTRICT FACILITIES, DESIGN AND CONSTRUCTION ADDENDUM NO. 1

5-5/8" (143 mm) 4" (103 mm) (103 mm) CEILING CUTOUT. ø 3-1/2" (89 mm)

Reflectors are compatible with respective Marquise II series housings manufactured by Nora Lighting.

Linear. Jump Wall/Cantilever

NIOB-2 2" BWF IOLITE TRIMS

J TO 4000 LUMEN 8 LED CYLINDER HYPERBOLIC/PARABOLIC/WALLWASH OPEN APERTURE LC8 SERIES DIMENSIONS 1-1/4

Associated Rsets. Associated Drivers. XI013C030V048DNM1 0-10V dimming Rset2. XI025C100V045DNM1 0-10V dimming Rset2

Catalog # Project. Comments. Prepared by

Fahrenheit DRD3 Adjustable LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Recessed. DuaLED 2x2. with SpaceWise Technology Option

PROJECT INFORMATION PROJECT

Roadway. RoadView. Succeed in your roadway lighting design goals

Tove. High Performance Linear System Recessed

6" LED Open Downlight LF6LEDG4 120V 277V 0-10V Dimming

Catalog # Project. Comments. Prepared by MAX HEIGHT (SEE TABLE) NARROW 5-15/16" [151mm] 5-15/16" [151mm] 7-11/16" [195mm]

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) A Acrylic Diffuser

2000 LUMENS A3-LED. Submittal form is Tel: Fax:

Recessed. HP90 Fluorescent 1x4

5-3/4" (144 mm) 6-3/8" (162 mm) ø 4" (102 mm)

LED Modules. Fortimo SLM. Fortimo LED SLM Gen lm L13

DRD2 Recessed LED Downlight Commercial New Construction 4, 6, 8 Aperture

Transcription:

½" mm ⅛" mm Total height of Light engine + Reflector ⅛" mm ¼" mm Project: Downlighting Location: Cat.No: Type: Calculite LED " features an LED array of high brightness white light LEDs. The new LED boards in Calculite LED ensure a less than -step SDCM color variation between luminaires. Calculite LED " Downlight Round aperture, Narrow, Medium & Wide beam ///lm Lamps: Complete product = Frame-in kit + Trim kit Lumen package for the frame-in kit must match the trim kit. Frame-in kit Series Qty: Notes: example: CLNUVBZV Lumens Installation voltage Version Dimming Options VB CL Calculite " LED round aperture CL Calculite " LED round aperture (v configurations) CUL Calculite LED Universal aperture lm N New construction R Remodeler U Universal (/ V) LD Lutron driver EM Emergency LC Chicago Plenum lm lm lm N New construction R Remodeler V V LD Lutron driver EM Emergency LC Chicago Plenum lm lm lm N New construction R Remodeler V - V (for Canada) lm N New construction V - V (for Canada) lm J J-box mount retrofit U Universal (/ V) lm J J-box mount retrofit V V lm lm S Screw-in base retrofit V Existing wiring will determine if dimming is an option. Existing wiring will determine if dimming is an option. Existing wiring will determine if dimming is an option. Trim kit Series example: CLDLKWCCDPVB Lumens Style CCT Reflector (Required for gypsum installations) CL CL Calculite " LED round aperture CAFMR Flange Version Flangeless trim with plaster ring accessory. VB // lm lm DL Downlight K K N Narrow, K K. s.c K K M Medium,. s.c. K K W Wide,. s.c. CL CCL CCD CCZ WH Clear Comfort clear Comfort clear diffuse Champagne bronze White (painted). C onsult LED-EM spec sheet for Emergency (EM) option details and restrictions. Not available with Lutron driver (LD) diming.. Consult factory for availability of other V (-) option configurations.. Consult factory for availability for other Chicago Plenum (LC) option configurations. Not available for () lumen frame-in kits.. Accessory CAFMR required for gypsum applications and flangelss (FT) trims (minimal " reflector flange).. Available for new construction (N) installation frame-in kits only.. Available for () lumen frame-in kits only.. Available for () lumen trim kits only. Note: See page for Energy Star compatibility. CalculiteLED-in-Downlight-CLDLVB / W White (painted) CAFMR P Polished Flangeless trim with plaster ring accessory. (Requiredaperture) for gypsum installations) (matches FT Flangeless (flush-mount), CAFMR Flangeless trim with plaster ring accessory. (Required for gypsum installations) CAFMR & CAFMR Flangeless trim with plaster ring accessory. (Required for gypsum installations) page of CAXFMR Flangeless trim with plaster ring accessory. (Required for gypsum installations)

" Round Aperture, Downlight, Narrow Medium & Wide ///lm New Construction New New Construction Construction Remodeler Remodeler Remodeler ½" ½" mm mm Side view ⅝" ⅝" Side view mm mm Side view Side view ¼" dia. ¼" dia. mm mm " dia." dia. Second driver on High Ceiling Trim Kits only mm mm CeilingCeiling cutoutcutout " max. " max. Maximum Ceiling Thickness mm mm "Ceiling max with Wide Ceiling thickness thickness " max with Narrow and Medium ¼"dia. ¼" dia. mm mm ¾"dia. ¾" dia. mm mm ¾" dia. ¾" dia. mm mm ⅞" ⅞" ½" ½" mm mm mm mm ⅛" ⅛" mm mm Total Total heightheight of of Light Light engine engine + + Reflector Reflector ⅝" ⅝" mm mm ⅛" ⅛" mm mm Frame-in kits New construction Mounting frame: Galvanized stamped steel for dry or plaster ceilings. Vertical adjustment: Light engine adjusts in frame below ceilings up to " max. Mounting brackets: Galvanized Steel. Adjustable through aperture. Use " or " lathing channel, " EMT or optional mounting bars (see Options and Accessories for optional mounting bars). Remodeler Quick-ship Philips is committed to providing customers with the products they need when they need them. For Service Smart ( day) and Spec Smart ( week) availablility please reference the Philips Luminaire Smart Service Guide or contact your Philips Lighting representative. Quick-ship SKUs apply to the United States only. " ¾" mm mm ¾" mm Junction box mount Options and accessories Dimming capability: -V or Lutron dimming (see LED-DIM spec sheet). Emergency capability: Inverter (see CP- spec sheet - ZI series). Integral (see LED-EM spec sheet - add EM suffix). Sloped ceilings: Retrofit Compatible with slope ceiling adapters Compatibility: Downlight only. (see SCA spec sheet). Capability: Converts " (mm) or Mounting bars: " (mm) Lightolier incandescent frame-in " long (set of ) kit without additional wiring using existing " long (set of ) Calculite E base. Wood joist telescoping Socket cup support: Spun steel. mounting bars (minimum Holds Calculite incandescent socket cup. " and maximum ") Socket extender: Phenolic E base. T-Bar anchor clips: Connect to existing lamp holder. For "/" mounting bars (set of ) CalculiteLED-in-Downlight-CLDLVB / page of Decorative elements: DA Consult in Vetro spec sheet Compatibility: Flanged downlight only. Power pack: Swivel junction box for tight plenum spaces. Snap-off covers permits wiring from top. Spring holder: Galvanized steel. Accepts up to " (mm) ceiling thickness. Retrofit Retrofit ¼" ¼" mm mm " ¾" mm mm ¾" mm Screw-in base

" Round Aperture, Downlight, Narrow Medium & Wide ///lm Calculite LED " CLDLKWCCDPVB Calculite LED " Trim kits are backwards compatible with all Calculite LED " Frame-in Kits. Trim kits. Heatsink cast aluminum. Thermal pad. LED board. Reflective insert. Reflector." anodized or panted aluminum. Mixing chamber injection molded polycarbonate. Diffusion film. Glass." clear borosilicate. Retaining ring." anodized aluminum Features Ceiling cutout: " aperture; " (mm). Depth: " ( mm) including light engine. Power connection: Attaches to light engine via push-in connector (on frame). Removable cover provides access. Junction box: Allows inspection from below. UL listed for No. AWG, C through branch circuit connectors. Thermal protector: Meets NEC & UL requirements. Do not install insulation above or within " of luminaire. Thermal Management: Heat sink and thermal design along with the clean room assembly process ensures specified performance levels are maintained. ENERGY STAR All new construction (N) frame-in and trim kit configurations are ENERGY STAR certified except for the following: - Trim Kits: Champagne bronze (CCZ) reflector finishes. - All lumen () optics configurations. - All lumen () optics configurations. - All emergency (EM) configurations. - All V configurations. Electrical Electronic power supply: or V, /Hz, encased, overload and short circuit protected, thermal regulation to protect against overheating, sound rating. A, - C minimum starting temperature. Rated life: Offers, hour rated life (lm offer, hour rated life) at % lumen maintenance (L). Tested in accordance with IES LM-- and TM--. Frame-In kit Electrical specifications CL UVBZV lm w/-v dimming volts freq. current Labels culus, I.B.E.W. Suitable for wet locations. year warranty. ENERGY STAR certified (see exclusions to the left). LED drive current LED power* power THD factor Power factor V /Hz.A ma W W <% >. V /Hz.A ma W W <% >. CL _VBZV V /Hz.A ma W W <% >. lm w/-v dimming V /Hz.A ma W W <% >. CLN_VBZV V /Hz.A ma W W <% >. lm w/-v dimming V /Hz.A ma W W <% >. * + - % = Applies to both New Construction (N) and Remodeler (R) Installations. _ = Applies to both V () and V () voltages. CalculiteLED-in-Downlight-CLDLVB / page of

" Round Aperture, Downlight, Narrow Medium & Wide ///lm Calculite LED " CLDLKWCCDPVB Calculite LED " Trim kits are backwards compatible with all Calculite LED " Frame-in Kits. Trim kits. Heatsink cast aluminum. Thermal pad. Connector. LED board. Reflector." anodized or panted aluminum. Mixing chamber injection molded polycarbonate. Reflective insert injection molded polycarbonate. Glass." clear borosilicate. Diffusion film. Retaining ring." anodized aluminum Features Ceiling cutout: " aperture; " (mm). Depth: " ( mm) including light engine. Power connection: Attaches to light engine via push-in connector (on frame). Removable cover provides access. Junction box: Allows inspection from below. UL listed for No. AWG, C through branch circuit connectors. Thermal protector: Meets NEC & UL requirements. Do not install insulation above or within " of luminaire. Thermal Management: Heat sink and thermal design along with the clean room assembly process ensures specified performance levels are maintained. Electrical Electronic power supply: or V, /Hz, encased, overload and short circuit protected, thermal regulation to protect against overheating, sound rating. A, - C minimum starting temperature. Rated life: Offers, hour rated life at % lumen maintenance (L). Tested in accordance with IES LM-- and TM--. Frame-In kit Electrical specifications volts freq. current Labels culus, I.B.E.W. Suitable for wet locations. year warranty. LED drive current LED power* power THD factor Power factor CLN_VBZV V /Hz.A ma W W <% >. lm w/-v dimming V /Hz.A ma W W <% >. * + - % _ = Applies to both V () and V () voltages. CalculiteLED-in-Downlight-CLDLVB / page of

" Round Aperture, Downlight, Narrow Medium & Wide ///lm W LED, K, Medium lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNUVBZV Trim: CLDLKMCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '.......... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % W LED, K, Wide lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNUVBZV Trim: CLDLKWCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '.......... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Wattage controlled to within + - %.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLED-in-Downlight-CLDLVB / page of

" Round Aperture, Downlight, Narrow Medium & Wide ///lm W LED, K, Medium lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKMCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '.......... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % W LED, K, Wide lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKWCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '.......... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Wattage controlled to within + - %.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLED-in-Downlight-CLDLVB / page of

" Round Aperture, Downlight, Narrow Medium & Wide ///lm W LED, K, Medium lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKMCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '.......... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % W LED, K, Wide lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKWCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '.......... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Wattage controlled to within + - %.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLED-in-Downlight-CLDLVB / page of

" Round Aperture, Downlight, Narrow Medium & Wide ///lm W LED, K, Narrow lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKNCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '..... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % W LED, K, Medium lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKMCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '..... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Wattage controlled to within + - %.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLED-in-Downlight-CLDLVB / page of

" Round Aperture, Downlight, Narrow Medium & Wide ///lm W LED, K, Wide lumen - - - -.%.%.%.% ' ' ' ' '.'.'.'.'.' CL = % CCL = % CCD = % CCZ = % WH = % K = % K = % K = % K = % Frame: CLNVBZV Trim: CLDLKWCLWVB CCT : watts : Spread: Report no : K lms. W. lm/w min. GFR * diameter is where drop to % of maximum. Multiple unit data - RCR ' ' ' ' '..... 'x'x' Room, Workplane.' above floor, //% Reflectances Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = %. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Wattage controlled to within + - %.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/luminaires CalculiteLED-in-Downlight-CLDLVB / page of Philips Lighting, North America Corporation Franklin Square Drive, Somerset, NJ Tel. -- Imported by: Philips Lighting, A division of Philips Electronics Ltd. Hillmount Rd, Markham, ON, Canada LC S Tel. --