GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

Similar documents
V. Design, Application, Maintenance & Operation Technical Requirements

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related

Operation and maintenance of 11kV, 33kV and 220 kv Substation.

SPECIFICATION FOR. MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons)

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Key features. DESIGNS: - Conservator type - Hermetically sealed

Operating Instructions

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

1. Inspection and Maintenance

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

UniSec Maintenance solutions

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Provincial Railway Guides Section:

Tamilnadu Trade Promotion Organisation, Chennai-89

Medium Voltage Metal-Enclosed Switches

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Installation, Operation and Maintenance Instructions. SLS Series Single Phase Disconnector

Manual for Inverter system type PCI05

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

PHYSICS 6 EXTENDED PHYSICS

9.1.4 Troubleshooting of Faults in LCD Screen

Department of Defense

Guidelines for connection of generators:

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

PR-PUB-NLH-034 NLH 2015 Prudence Review Page 1 of 1

FACT SHEET Standard: Electrical Safety

PORTABLE ELECTRICAL EQUIPMENT SAFE OPERATING PROCEDURE

NEXT STEP B) SAFETY :

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

PRECISION UK Ltd DUPLEX AGSS PLANT

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Car Battery Charger Instructions for Use

Heating and Gas Installations - December 2014

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

Chapter 6 Generator-Voltage System

Medium Voltage Metal-Enclosed Switches

PAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012

Amendment of UN ECE R100 regarding in-use requirements for vehicles of category L Status:

COMPACT SUBSTATION GUIDE

Publication No.: PSG

E-15 Uninterruptible Power Systems (UPS)

Unified requirements for systems with voltages above 1 kv up to 15 kv

2 TONNE TROLLEY JACK

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

2. All electrical items covered by Portable Appliance Testing must be tested on a regular basis by a certified competent person.

Report No.: Name of Ship: Plans referred during Initial Survey:

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Section S7 - DC and AC auxiliary services installations

Switchgear Arrangement, Torque Requirements, Insulation Systems & Maintenance Intervals. Mike Schmaderer

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

AIS Transportation Preventative Maintenance Procedures Manual

Wilkins Safety Group

Ensuring the Safety Of Medical Electronics

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

ELECTRICAL GROUNDING SAFETY PROGRAM

CALTRAP INSTALLATION AND OPERATIONS MANUAL

CAL/OSHA ELECTRICAL LOW VOLTAGE

OWNER S MANUAL POWER INVERTER

Presented to the IAPMO Standards Review Committee on December 9, 2013

Substation LV AC Supplies. Document Number: 1-11-FR-04

Likorall. LOAD TESTING 12 Mechanical lowering load test (242) Maximum load rail system... DOCUMENTATION 14 Instructions / Instruction guide...

The following standards of installation and maintenance are provided as a guide to good practice.

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Switchgear and Distribution Systems for Engineers and Technicians

E-12 Low-voltage Switchboard

Guideline for Parallel Grid Exit Point Connection 28/10/2010

3 TONNE TROLLEY JACK

PRACTICAL TROUBLESHOOTING OF ELECTRICAL EQUIPMENT & CONTROL SYSTEMS

INSTALLATION GUIDE AND USER MANUAL

University of Houston Master Construction Specifications Insert Project Name

UPS Battery Maintenance Training

In any of the 5 star hotels. The exact venue will be informed once finalized.

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

of Fire Pump Assemblies

PROCEDURE. Operative Date: 22/12/2016 Department: HSEC. Revision: Author: D Steel CONTENTS

REVISION HISTORY REVISION NUMBER. DATE PAGE CONTENTS New 28-May-2015

LIQUID LEVEL FLOAT SWITCH. F7 Series INSTALLATION AND OPERATIONS MANUAL. Single-Point, Vertically-Mounted Liquid Level Float Switch

Dial-A-Ride Coles County Council on Aging, Inc. Facilities/Equipment Maintenance

Table of Contents Foreword I. Product Introduction II. Notice For Safety III. Main Technical Parameters IV.

INSPECTION AND MAINTENANCE CHECKLIST

Company Directive STANDARD TECHNIQUE: SD4O/1. Standard HV Connection Arrangements

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Equipment Strategy for Stand By Diesel Generators Strategy

Electrical Safety. Presented By- C S Chakraverty. L&T Construction ( MMH ) Head- E&I Operation

XS400 Load Bank. Read all instructions before using the load bank. Contents

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Transcription:

PART B-04 TITLE: DISTRIBUTION SUBSTATIONS SPECIFICATION NO: B-04 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 2 YEAR PERIOD) AMENDMENTS/REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED Page B-04:1

TABLE OF CONTENTS PAGE 1. SCOPE... 3 2. INSPECTION, MAINTENANCE, AND TESTING CATEGORIES... 3 2.1 Periodic inspection and maintenance... 3 3. PREVENTATIVE MAINTENANCE AND TESTING... 4 3.1 Condition-based maintenance... 4 3.1.1 Post fault conditions... 4 3.1.2 Other conditions... 4 4. PROCEDURES... 4 4.1 Written policies and procedures... 4 4.2 Procedures for inspecting... 5 4.2.1 General... 5 4.2.2 Control room... 5 4.2.3 Medium voltage equipment... 6 4.3 General conditions... 7 4.2.2 General... 7 4.2.3 Reporting and recording... 8 5 PRIORITY RATINGS... 9 6 DOCUMENTATION... 9 Annex A... 10 Annex B... 12 Page B-04:2

1. SCOPE This document provides guidelines for the minimum maintenance requirements of distribution substations. A distribution substation is defined as a part of an electrical system, confined to a given area, including mainly the termination of distribution lines, switchgear, buildings and transformers. 2. INSPECTION, MAINTENANCE, AND TESTING CATEGORIES The following maintenance strategies are applicable to the maintenance of distribution substations. a) Periodic inspection and maintenance should be performed to verify proper system operation and general system upkeep. b) Preventative maintenance (PM) and testing may require removing the equipment from service and performing tests on the equipment or the materials to ensure proper operation. This type of maintenance occurs on a regularly scheduled basis. c) Condition-based maintenance should be performed following a fault condition, excessive number of operations of equipment or any abnormalities found. 2.1 Periodic inspection and maintenance Substation monthly inspections and maintenance should consist of the following: a) Verify cleanliness of substation, both inside and outside the building should there be a building. Particular attention should be given to combustible rubbish material such as newspapers, drawings and storage of materials not related to substation operations and maintenance in the same room or area. b) Check for the presence of oil, dust or other material generated from traction power equipment inside or outside the equipment room or building. c) Inspect and replace air filters if necessary d) Verify correct operation of any oil/water separators. e) Check for presence of water or other material leaking into the substation from elsewhere. f) Check for the presence of any burning smell, fumes, scorch marks or other material that could be signs of a future breakdown. g) Test emergency exit lighting and doors to verify they are fully operational. h) Verify operation of all lamps. Replace as necessary. Page B-04:3

i) Verify operation of all alarms. j) Verify operation of heating and ventilation systems. k) Verify that voltmeters/ammeters/wattmeters (and battery chargers and inverters if present) give sensible readings. Investigate any unexpected readings. l) Record all counter readings and other parameters as required and where available. 3. PREVENTATIVE MAINTENANCE AND TESTING Preventative maintenance should include all items in Section 3.1 of this document. 3.1 Condition-based maintenance 3.1.1 Post fault conditions Post-fault conditions are defined as any condition where a system failure occurred that has caused either repetitive faults or lockout trip of any subsystem. Example: A dc circuit short circuit would require a thorough check of the circuit breaker, distribution system, ground, and associated devices. 3.1.2 Other conditions a) Exceeding the recommended number of operations under load conditions for circuit breakers. b) Defects encountered during monthly inspections that would generate a priority 1 or 2 as listed in Section 5 of this guideline. c) Any abnormal conditions found. 4. PROCEDURES The Licensee should perform inspection, maintenance, and testing in accordance with this guideline and develop local policies and procedures to meet the requirements herein. No work should be performed unless proper procedures, documentation, and authorization have been obtained to perform the prescribed task at the designated location. Upon completion of the work, the respective supervisor must be informed that the prescribed task is completed. 4.1 Written policies and procedures Each Licensee should develop specific written policies and procedures that take into account specific equipment designs and local operating conditions to implement the inspection, maintenance, and testing required by this guideline. These policies and procedures should give maintenance staff clear guidance and criteria for performing these activities. Page B-04:4

4.2 Procedures for inspecting To monitor the condition of the Substation the following should be done: 4.2.1 General In the absence of an RCM Study, all Substations and major primary equipment within should be inspected at least once quarterly. a) All defects should be reported immediately to the Licensee s respective supervisor for immediate attention. b) All defects found should be recorded and reported through the appropriate channels along with the date and time of the inspection and the name and department of the person who carried out the inspection; c) If there are any defects that can be corrected with the equipment in service, immediate action should be taken. E.g. replacement of silica gel. d) Pollution levels on all equipment should be visually inspected. An anti-pollution medium should be applied in accordance with local requirements. 4.2.2 Control room a) All panels should be correctly labelled at the front and back (if applicable); b) All panels should be clean and free of dust; c) All indication equipment should be working; d) All meters (e.g. ammeters, voltmeters) and recorders should be in working order; e) All panel-blanking plates should be fitted as required; f) Key boxes, where fitted, should be kept locked or sealed; g) The latest revision of the substation diagram should be displayed at all times; h) All kwh, kva and kvah demand indicators should be inspected and readings should be taken; i) All protection relays that may have operated should be checked, logged and only reset once reported to the relevant control centre; j) NB: Turn the panel light switches to the off position after concluding an inspection; k) The substation logbook should be in place; l) Panels opened should be barricaded; m) Control panel labelling should be permanent. Page B-04:5

4.2.3 Medium voltage equipment 4.2.3.1 Outdoor Busbars and structures a) Inspect all busbars and structures for discoloration (indicative of overheating), galvanic corrosion, deformation, buckling or cracking. Where corrosion occurs, this should be immediately rectified. b) All insulators should be checked for chipped, cracked or broken sheds. A maximum of 20 % of chipped, cracked or broken sheds is permitted on an insulator. c) Check all connections for loose, missing or damaged bolts. d) Busbar labelling should be legible and correctly installed. e) Structure earthing should be intact and properly connected. f) Check for bird nests. g) Ensure that all equipment that should be locked is locked. h) Ensure that all barricading is in place where applicable. 4.2.3.2 Air-break isolators Air-break isolators should be inspected and maintained in accordance with OEM manuals 4.2.3.3 Circuit-breakers Circuit-breakers (including indoor switchgear) should be inspected and maintained in accordance with OEM manuals 4.2.3.4 Instrument transformers a) Insulators should be inspected for chips or breakage. A maximum of 20% of chipped, cracked or broken sheds is permitted on an insulator; b) There should be no insulating oil leaks or SF6 leaks (check SF6 pressure gauge). If any leaks are found these should be repaired by authorized personnel only. c) All oil levels should be correct; d) All gauge glasses should be clean and clear; e) Terminal box covers should be secured in position. Wire should not be used to secure the covers; f) All metal work should be checked for corrosion and rust; and g) Earth straps should be in good condition and should be effectively connected. Page B-04:6

4.2.3.5 Capacitor banks Note: Do not enter a capacitor bank enclosure when the capacitor bank is live. Capacitor bank maintenance should be carried out in accordance with OEM manuals and/or in compliance with applicable standards. a) Externally fused capacitors should be inspected for blown fuses; b) Insulators should be inspected for chips, cracks or broken sheds. A maximum of 20 % of chipped, cracked or broken sheds is permitted on an insulator; c) Capacitor cans should be checked for insulating fluid leaks; d) The fence and gate should be checked to ensure that they are properly secured, in a good state, free of rust and effectively earthed. The gate should be locked at all times with the appropriate type of lock; e) All notices and labels should be securely fixed and legible; f) Earth straps should be in a good condition and should be effectively connected; and g) An earthing procedure for each specific unit should be available at each site for earthing purposes. 4.3 General conditions 4.2.2 General All fences and gates should be properly secured, in good mechanical condition and they should comply with applicable earthing standards. a) All statutory notices and signs should be clearly displayed b) All buildings, doors, windows and paintwork should be in a good condition; c) All MV yards should be free of weeds and clear of loose wires, debris and unused equipment; d) All telephones and radios should be in working order and emergency telephone numbers should be displayed next to the telephone; e) All trench covers should be in place and free of damage; f) Yards should be free of silts and water pooling after rain; g) Floodlighting should be checked to ensure that all lights are working. If fitted with day/night switches, the functioning of the day/night switch should also be verified; h) Stand-by generators should be run-up in accordance with the relevant procedures; Page B-04:7

i) All indoor lights and emergency lights should be in working order; j) Access roads should be properly maintained. k) Any excessive audible noise i.e. transformer vibration or arcing of substation equipment should be reported to the responsible person; 4.2.3 Reporting and recording All substations should have a log book and inspection sheet. All work done by any person at the substation should be recorded. An example of such a sheet is shown in Annex A. The following should be recorded, as a minimum, into CMMS (Computerized maintenance management system) after each inspection: a) Present and maximum loading of all panels in amperes; b) All relays that may have operated since the substation was last visited; c) All fault trips; d) All oil levels, SF6 and air pressures; e) Present and maximum oil and winding temperatures of all transformers; f) All breaker counter readings. Concerning breakers with panel and mechbox meter, the mechbox meter reading should be recorded. g) Tap-change operations, if applicable; h) All checks undertaken such as; 1) Lighting; 2) Stand-by generator, 3) Cooling fans and oil pumps. i) The condition of silica gel and the oil dashpot on all breathers; j) All defects found should be noted and reported to the appropriate supervisor; k) Date and time of the inspection and the name of the person who carried out the inspection. Page B-04:8

5 PRIORITY RATINGS The licensee should develop a priority rating system to evaluate and determine the effects that any single defect will have on the network if they choose to operate with a known defect. Recommended priority ratings are: Priority 1: The defect will endanger the safety of personnel and/or continuation of revenue service. A permanent or temporary repair should be made immediately. Priority 2: The defect may cause disruption of revenue service. The repair should be made in a predetermined timeframe set by each system. Priority 3: The defect will not affect revenue service. The repair should be made in a predetermined timeframe set by each system. 6 DOCUMENTATION The Licensee should develop and implement a fully auditable process for recording and tracking inspection, maintenance, and testing activities and outstanding system defects. Such documentation should be documented, reviewed, and filed in accordance with electricity distributer s procedures and the equipment manufacturer s recommendations. Documentation should be kept for the life of all in-service equipment. Page B-04:9

A.1 Informative Annex A Recommended Inspection Intervals for Substations The following are guidelines and recommended intervals for the various maintenance inspections to be carried out on Substations Item/Equipment Interval Activity Substations Quarterly Inspection and cleaning substation Cleaning (surroundings) Quarterly Inspection and cleaning Batteries monthly inspection Security Systems monthly inspection Workshop equipment monthly Safety checks Air-conditioning monthly check and clean filters Mini Substations Quarterly Inspection and cleaning Substation surroundings Quarterly Cleaning and cutting of grass Filter Plant Quarterly Check and maintain Workshop equipment Quarterly Check and maintain Page B-04:10

Neutral Resistors half yearly Inspect tanks and check valves Outdoor substation yard half yearly Infrared scan. Insulator washing Motorized Isolators half yearly Check and maintain Substations Annually Fire extinguishers overhaul. Transformers Annually oil tests On Load Tap Changer 2 yearly Overhaul Substation Buildings 5 yearly Paint and maintain Outdoor transformers 5 yearly Paint and maintain Open Substation Yards 5 yearly Paint and maintain Batteries 5 yearly Clean and overhaul Substations 10 Yearly Clean and overhaul Page B-04:11

B.1 Documentation Annex B (Informative) Each substation should have a logbook or CMMS containing the following transformer information: Transformers: a) Make b) Type c) Serial No d) Vector Group e) MVA f) Voltage Ratio (MV/LV) g) Rated full load amps (MV/LV) h) % impedance The following should be recorded in the substation logbook at each inspection: a) Present winding temperatures, where applicable b) Maximum winding temperatures, where applicable c) Present LV load in amps, where applicable d) Maximum LV load in amps e) All oil levels (Main and conservator) f) Condition of silica gel and oil dashpot g) Working condition of the cooling fans, where applicable h) Any defects or abnormalities found and details of repairs i) Date and time of the inspection j) The name of the person who carried out the inspection Ring main units: a) All oil levels b) SF6 pressure level c) Earth fault indicator d) Any defects or abnormalities found and details of repairs e) Date and time of the inspection and f) The name of the person who carried out the inspection B.2 Training The maintenance staff should have adequate training and competence to perform required tasks safely. Page B-04:12