Switchgear Skid, C1192

Similar documents
ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Three-Phase Pole Mounted Recloser

SWITCHGEAR DIVISION PRODUCT PROFILES

C1000 Series Automatic Cap Bank

Integrated Power Solutions

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Horizontal Circuit Switchers

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Horizontal Circuit Switchers

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Submersible Vacuum Fault Interrupters

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

NEW Solutions for Underground System Growth

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

10. METERING General Requirements

Customer Requirements Meter Socket Configurations

Technical Specification for Pole Mounted Capacitor Rack

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

BGE STRATEGIC CUSTOMER ENGINEERING

Outdoor Enclosure Power System ENC X100MP48F20-AC6

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

SECTION PADMOUNT TRANSFORMER - OIL FILLED

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

C. System Design and Performance Requirements

Underground Distribution Switchgear

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

10 Commercial, Industrial, Agricultural Services

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Wye or Delta Systems DS9181 (CSA Approved)

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Outdoor Enclosure Power System ENC X100MP48F20

Cobra-S. Catalog Cobra-S

OPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Customer Substation Manual

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

MASTERCLAD Metal-Clad Indoor Switchgear

P80074 (150 amp connectors) P80071 (300 amp connectors)

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

PT-200-S Cell on Wheels (COW)

Typical Specification

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Mobile Generator MMG130 Specifications

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

UNDERGROUND SERVICES - SECONDARY

Magnum Mobile Generator MMG125 Specifications

Underground Distribution Switchgear

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Medium Voltage Metal-Enclosed Switches

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Magnum Mobile Generator MMG235 Specifications

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Tradition. Technology. Innovation.

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Metal Clad VCBs ~ Mk1

Unit Substation Transformers 5 and 15 KV Class

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

University of Houston Master Construction Specifications Insert Project Name

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Magnum Mobile Generator MMG75 SS Specifications

Design Standard. Purpose: Design Standard:

COMMERCIAL QUICK REFERENCE

Chapter 6 Generator-Voltage System

Approved Contractor Construction e-guide Residential Commercial

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Magnum Mobile Generator MMG75 Specifications

Publication No.: PSG

Flashing Arrow Panel - 615/815 T/Y

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

STATE OF MINNESOTA PRICING Page % DISCOUNT

Power Break II Switchboard

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Power/Vac OEM Express Switchgear

Approved Meter Sockets and Cabinets

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Transcription:

CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

CUSTOM SOLUTIONS 15kV Modular Application Portable power distribution. Problem Solved Provide a trailer mounted modular skid to bypass main system or provide temporary power in emergencies. Item 1- A 15kV Modular Trailer Mounted Enclosed Secondary Switchgear The trailer mounted modular skid shall consist of a trailer mounted line up of draw-out vacuum circuit breakers and associated controls. The enclosure shall be durable dry powder painted steel. The entire assembly shall be 95kV BIL construction to facilitate use on 13,800V system. The trailer shall include the following: Trailer features include: 8x25 tri-axle, 15,000 lbs. rated, dual tag-along type, 12 I-Beam main frame, 4 each drop-leg leveling jacks, 12 each 16 ply radial tires, 11-gauge checker plate floor and DOT lighting. The trailer shall have two stainless steel ground pads for field grounding. The switchgear enclosures will be Type 3R. The finish shall be the same ANSI 61 Gray tough paint and coating system used on Federal Pacific/ Line Power pad-mounted and metal-enclosed switchgear, based on the requirements of IEEE Std C57.12.28-1999, Coating system performance requirements. The outside skin will be a minimum of 11-gauge. A 1/2 x 4 copper ground bus runs the full length of the enclosure. An outdoor ground, which is painted grey, is located on the main circuit breaker bay. The switchgear is furnished with a circuit breaker electrical racking device, a circuit breaker manual operating handle, a breaker cranking handle, a circuit breaker manual charging handle, and a circuit breaker lifting yolk. All sections of the enclosure will be supplied with space heaters to eliminate condensation. A thermostat and humidistat will be supplied. Outdoor lights will be on each end of the skid. All bus is copper and grounding stirrups are supplied. 90 flanges under circuit breaker doors to guard against water entry. Rear doors shall be hinged and bolted with a padlock provision. A portable stair and platform assembly shall be provided for access to switchgear. Stair shall be stored over tongue for installation where needed. Provisions for hooks on stair and slots for hooks on side of trailer shall be provided. The stair assembly will be fitted with a ground strap for grounding to the trailer. A galvanized base and take-off tower are not included in this offer. BAY 1 2000 amp main draw-out vacuum circuit breaker. Vacuum circuit breaker is a premium, highly reliable, magnetically actuated vacuum circuit breaker. Breaker rating: 15kV, 40kA interrupting current, 2000 amp continuous One set of three (3), 3000:5 multi-ratio current transformers on the line side of the breaker, and one set of three (3), 3000:5 multi-ratio current transformers on the load side of the breaker. Each CT is rated C400 down to the 1200:5 tap. Incoming may be either in the bottom with entry onto lug pads suitable for 4 each 1000kcm aluminum cables per phase, or in the top through three 2000 amp polyester air-to-air bushing insulators, gray glaze with creepage as required for corrosive and contaminated environments.

15kV Modular BAY 1 - continued A removable link will be provided to de-energize the roof bushings when not in use. (i.e. when bottom feed is selected.) A circuit breaker test cabinet shall be mounted in Bay 1 and fitted with 30 long leads. BAY 2 A draw-out tray with three (3), 7970V, single bushing, fused PTs shall be located over the circuit breaker. BAY 3 One (1) 13,800CPT, (station power transformer), 25kVA. One (1) draw-out fuse drawer for CPT. BAY 4 and BAY 5

CUSTOM SOLUTIONS 15kV Modular BAY 6 Control Section-housing relays and electronics. The Control Section shall include the following: Qty. 4 SEL-351S - 351S7XHB4F5462 1 SEL-351 351S71H4455462 2 SEL-0551-0551003X5X1X 1 SEL-587-058710325X1X 1 SEL-241101A3A3A3A3A013X 1 1 Item Cooper SMP-CP 16-125-250VDC, Cable serial-3 DB9M- 83-946, surge suppressor-fsp 401 MC, 4PT terminal block-1504djrc72459, 12PT terminal block-1512djrc72459. B & B Electronics #485LDRC9, 9-PIN, RS-232 to RS-422/485, optically isolated converter (din rail mounted) 1 Transtector surge suppressor, double wire pair, (4) wire, 2-20ma, RS-422, #FSP 4001MC 4 FT-14 Switch 8 FT-1 Switch 7 Switches 1 Digital Counter 13 Toogle Switch 14 LED Lights 1 Pomona 4969 Converter 1 Miscellaneous terminators and connectors A rear door will allow for access to the back of all relay and control components. A hand operated pendant with a 50 cord will be supplied for remote circuit breaker close and tripping. The pendant is a water/oil tight NEMA 4 hand held device similar to a crane control pendant. Fitted with a plug, it can be plugged into a receptacle corresponding to any of the circuit breakers in the line-up. An AC and a DC panel board are included in the rear of this bay. All circuit breaker DC circuits will run directly from the DC panel board. Two (2) 120V convenience receptacles.

15kV Modular BAY 7 Battery and Power Compartment Batteries to be stacked or two- tier in lieu of two-step to save depth. The battery compartment will be provided with a large double door opening at the end to remove or service batteries as required. The landing will be coated with skid resistant paint. Battery system 60-6V-6oGi-150-N6, rated 150AH, 125VDC is in the base price. A retracting mast shall be fixed to the bay for antenna mounting. The mast shall lift the antenna over the top of the enclosure. An external control termination cabinet located on the side to accept four each 4 conduits from below. Control wires exiting this structure will be terminated on well marked terminal blocks. Portable Ground Grid Assembly Quantity of twenty-two (22) 4 x5 panels of extra rigid crimped wire cloth, 304 stainless steel, 2-inch opening, 0.120-inch wire diameter. Panels are equipped with 304 stainless steel tabs for joining together and grounding to existing underground ground grid/rods. Quantity of twenty-four (24) PVC posts with post driver, pointed socket and post caps. 125 of rigid polyethylene fence, 2 x 2 diamond pattern, 48 tall, orange in color. Ground lug and ground wire for securing ground grid to main ground. Storage brackets on rear of switchgear for storing ground grid during transportation. Approximate Total Dimensions: 40 L x 8 W x 13.25 H (Mast extends to 26.5 H) Approximate Weight: 35,000 pounds Estimated Lead Time 3 Weeks Engineered Drawings 18-20 Weeks Fabrication Upon Release