Inst all a ti o n and Oper a tin g Instru c ti o n s

Similar documents
Bianco RainsaverMK4E Installation and Operating Instructions

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

INSTRS30709 rev 1 02/10/09 Page 1

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

Bianco Rainsaver MK3 Installation and Operating Instructions. The no brainer. Bianco Rainsaver MK3 & MK3E Installation and Operating Instructions

CENTRAL SLURRY SYSTEMS Model 911

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

OWNER S MANUAL FOR THE PROTECTEAT TEAT SPRAY SYSTEM

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

OPERATION & MAINTENANCE INSTRUCTIONS

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

CENTRAL SLURRY SYSTEMS Model 915

123 Industrial Loop Road Paynesville, MN Phone:

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Instruction Model 18537

Rainwater Harvesting Solutions WATER STORAGE AND RAINWATER HARVESTING USER MANUAL ABOVE GROUND WATER TANKS

first flust water diverters water quality first downpipe, post/wall mounted and in-ground diverters

Fuel Tank Sweeper #9049 OPERATOR S MANUAL

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

MODEL NO. UTL-60-7

FIXED DEPTH INSERTION METER INSTRUCTIONS

1600 PSI ELECTRIC PRESSURE WASHER

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Tools Needed for Mounting Cleá Filling Station

Breezair TBA 550 Installation Manual

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Installation & Operation Instruction Manual FWINSMAN300. Yardney - Filtaworx FW02 - FW03

Flotender Owners Manual. For Greywater Recycling Systems

Oil Pump Models L 5016, L 5116 & L 5132

Matala. VersiFlow Series. Instruction and Maintenance Manual

MODEL NO. SK-61-12V 12 VOLT SKID MOUNTED LAWN & GARDEN SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

PRE-PLUMBED SEWAGE SYSTEM

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

OPERATION & MAINTENANCE INSTRUCTIONS

OWNER S MANUAL Model: LG ( ) (25 Gallon Lawn & Garden Trailer Sprayer)

Installation Operation Parts

HALLMARK INDUSTRIES INC

LAWN SPRINKLER, IRRIGATION PUMP

WARNING Carefully Read These Instructions Before Use

SUBMERSIBLE DIRTY WATER PUMP

GB2 35/50 GPM Grease Interceptor for Indoor Use

Hampton Roads Planning District Commission

Submersible Tank Pump

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

SUBMERSIBLE WATER PUMPS

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information

INSTALLATION, OPERATING AND SERVICE MANUAL

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Model: SK-61-4R 60 Gallon Skid Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

MODEL NO GALLON H.P. SKID SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

PROPER ELECTRICAL CONNECTIONS

Owners Manual: - Pumps

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

GeyserMax-Flow Series

MODEL VG08001 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Owner's Manual. Model: ( ) (150 Gallon, 5.5 HP Skid Sprayer) Technical Specifications. General Information. Warranty/Parts/Service

Rain Harvesting Pty Ltd

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Tank at Ground Level. Tank on Stand

OWNER S MANUAL. Model: ATV ( ) ***IMPORTANT REMINDER*** Technical Specifications. Assembly Instructions. General Information

KNAPSACK ELECTRIC SPRAYER

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

Installation must be in Accordance with AS/NZS

MODEL H INSTALLATION INSTRUCTIONS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

LG-60-3PT-WP-309-BL-TSC

Installation - Tank & Aerator

WASH SYSTEM. Instructions for Use

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Pressurized Bead Filters

PACKING LIST DESCRIPTION MODEL NUMBER - PANEL HOUSING HAND SHOWER HOSE HAND SHOWER FLEXIBLE HOSES 16" LONG WITH 1/2" FEMALE 88

INSTALLATION & OPERATING INSTRUCTIONS

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

Reverse Osmosis System

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Installation and Operation Instruction Manual FWINSMAN303. Yardney - Filtaworx FW06EX - FW10

Model S-777NA USER MANUAL. Please ensure this manual is read and understood before using the scooter.

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

Transcription:

Inst all a ti o n and Oper a tin g Instru c ti o n s Congratulations, you are now the proud owner of an Aqua2use GWDD!

INSTALLATION OF PUMP OPERATED AQUA2USE GWDD The Matala Aqua2use GWDD is specifically designed for Grey Water (Gray Water) reuse from the laundry, shower and bath waste water. We recommend that you also check with your local Water Authority if an approval must be applied for to install this type of Seasonal Use Grey Water Diversion Device and if there is any restriction as to who is allowed to install this unit. It is mandatory that the power circuit to the Aqua2use GWDD is protected by a residual current circuit breaker and we highly recommend a surge protection device be fitted as well. CONNECTING YOUR UNIT 1. Position the unit near your 50mm (2 ) DWV greywater waste pipe, allowing approx 360 mm (14.2 ) from ground level to cut in point Inlet A and 214mm (8.4 ) from overflow point C If the unit is not preassembled remove the filters and all of the fittings from the unit, taking note of the order of the filters. Water should flow from inlet to outlet through the Black Green Blue Grey filters. 2. Sit the unit on a suitable concrete slab as a stable base making sure that the unit is level and the drain point M is accessible. Assemble and fit the drain assembly M. Ensure the backing nut is tight. The fitting on the drain has a 25mm (1 ) thread and plug provided and the outside diameter is suitable for 40mm (1.5 ) DWV pipe. This should be plumbed back to your waste pipe for ease of cleaning. The plumber can fit an inline valve here for easy flushing. 3. Now assemble the inlet basket D. Position the threaded elbow inside the basket to the lowest point with the female thread pointing outward. Fit the bulkhead adaptor C through the corresponding hole in the tank R into the inlet basket. Make sure it is tight and the gaskets are in place. The elbow should be facing down. Now thread the upper bulkhead adaptor C into the female thread diverter valve. Again make sure it is tight and the gaskets are in place. 4. Fit the overflow stand pipe E to corresponding hole in the bottom of inlet basket. Make sure the pipe fits through the basket. It is possible to adjust the overflow level by moving this pipe up or down, but we advise that, the bottom end of the pipe reaches the lowest point of the basket. The inlet and overflow assembly should now be completed.

5. Now assemble the fittings and hose to the pump. First the 32mm (1 1/4 ) socket and hose barb are fitted to the top of the pump. Use multi grips to tighten the fittings on the pump. You will need warm water to make the hose flexible enough to fit over the barbs. Hands tighten the hose clamp on the pump end. Now fit the outlet barb O to the hose. This barb has several steps. Cut off the first section. The 32mm (1 1/4 ) hose fits the second step. Tighten the hose clamp on this section. The pump is now ready to be placed in the unit. 6. Carefully position the pump into the tank. Place the outlet adaptor P through the upper outlet in the tank. Tighten the locking nut. Now fit the level control box to the tank. The SS bracket is designed to fit between the two ribs of the tank wall. This has to be firmly in place. Make sure the probes aren t touching any part of the tank or the pump. The floats must move freely. Also inspect the floats for damage that may have occurred in transit. 7. Starting at the inlet basket end install the MATALA filter media in the tank. Starting with BLACK then GREEN. Make sure the filters slide all the way home to fit snug to the bottom of the unit. 8. Now install GREEN and BLUE filters. Again Make sure the filters slide all the way home to fit snug to the bottom of the unit. 9. Now you are ready to install the last two MATALA filters in order, BLUE then GREY. Make sure all filters are correctly installed. There should be no gaps around any part of the filter. Note: the Grey filter is the largest filter and sits higher than all the other filters. 10. Now install the Stainless Steel anti distortion bracket across the middle lugs of the Aqua2use GWDD. 11. Take the electric lead out through cut out in the tank. 12. Assemble the diverting valve B insert locator to the diverting valve inlet cover S. Now fit this inlet cover to the lid. The locator lugs clip to this assembly to the lid. 13. It is advisable as this point to flush the unit with clean water to check the operation of the pump. This will also ensure that no foreign material enters the drip system and that your unit is operating correctly.

14. Finally fit the Aqua2use GWDD tank cover Q to the tank and lock it using the two Stainless steel clips provided. 15. The Aqua2use GWDD unit can be buried and backfilled with clean loose sand up to the outside lip on the main container. Maximum burying depth is 400mm (15.7 ). Make sure the lid is still accessible and that dirt or other material will not enter the unit or interfere with the bypass valve. Your Matala Aqua2use GWDD unit is now ready for operation. GRAVITY OPERATION OF MATALA AQUA2USE GWDD UNIT 1. The assembly of the Gravity operated unit is exactly the same as the Pump operated unit. The difference is that the discharge point is now the same as the drain point in the pump system. It is not recommended to bury a gravity system. 2. Because you are not using a pump to produce the head pressure to move the water out of the Aqua2use GWDD, it is critical that the location of the Gravity unit is of sufficient height to operate the drip system. Generally 1 metre (40 inch) is the absolute minimum head required. Please refer to manufactures recommendations as this will differ between products. 3. Connect a length of 25mm (1 ) lilac pipe from the point M to your dripper system. Using a larger pipe will mean less friction loss. This is critical for the efficient operation of a gravity system. 4. Fit a bypass tee and two inline vales to this pipe before it connects to the drip system. Both valves are located on the downstream sides of the tee. By opening one valve and closing the other this will allow you to flush out any left over sludge after you clean the filters. The drain flush line can be plumbed back to your sewerage system. TROUBLE SHOOTING Water does not flow into Check the diverting valve, reset to correct position.

the unit The unit is full but the pump is not operating The pump cannot maintain the rate of Inflowing water. The pump section is empty while the water level is high on inlet side Grey Residual is building up around the Pump Offensive odours are released from your unit Check if pump is connected to the power source and check if power is available. The pump should automatically start when water reaches the higher float switch. If the pump does not start, clean the top float switch and test again. Make sure neither float is jamming. If it still doesn t operate, then call a licensed service agent. A correctly designed irrigation system should allow the outflow to be equal to the inflow. Are you using the correct main line and drip tube? And do you have enough drip tube connected. Also check for kinks or blockages in pipe work from unit. If you intend to irrigate sloped area, please consult an irrigation specialist to adjust your irrigation equipment and lay-out accordingly. Service and clean the filter media to maintain Flow. Check the filter media, make sure it is seated correctly and that there are no voids under the filter mats which will cause bypass around the filters. Your unit could need servicing. Thoroughly clean the unit and the filter media. Make sure No non dissolving substances have entered the unit. IE fats and oil. WARNINGS AND PRECAUTIONS FOR GREY WATER (GRAY WATER) REUSE Do not connect your Aqua2use GWDD to your kitchen sink, dishwasher or a toilet system. When washing items such as soiled nappies, please switch your diversion valve to divert direct to the sewerage system. Do not distribute grey water from your Aqua2use GWDD unit via sprinklers or allow for airborne dispersion. Only irrigate when necessary and switch unit to divert when raining. Do not let diverted greywater to run off to neighbouring properties. Do not leave unit unattended when carrying out maintenance or when the cover is removed.

In case of extended periods of non operation it is advised to complete a service and clean of the unit to avoid the possibility of drying out the sludge on the filters. MAINTENANCE OF YOUR AQUA2USE GWDD Your Aqua2use GWDD has been designed for minimum maintenance. Due to the high flow capabilities of the 3 dimensional MATALA filters you should only need to clean your unit after approximately 40,000 litres (10,500 gallons) of flow through. Depending of the number of occupants and the amount of water flowing through your unit the cleaning cycle will be between 120 180 days. Your MATALA filters still will keep working even up to maximum capacity. Some heavy load situations may require servicing your unit on a more frequent basis. If you are considering not using your unit for an extended period of time such as a few months. Please carry out a full service and clean before decommissioning. This will keep your Aqua2use GWDD in optimum condition. When servicing and cleaning your unit please we recommend that you wear protective rubber gloves and avoid skin contact as much as possible. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Turn the diverting valve B to the bypass position. This will prevent greywater entering the unit. Remove the Stainless Steel clips from the unit. Then remove the lid. You can now access the MATALA filter media. For PUMP OPERATED UNITS it is advised to drain the unit via the drain fitting M. For GRAVITY OPERATED UNITS you need to open your drain valve on the bypass tee. If you don t have this installed remove the pipe from the bottom fitting M and fit a temporary drain away from the unit. Sediment will now be directed away from your irrigation system. Rinse the pump with clean water. Caution Do not spray water onto the Electrical control box. Remove the MATALA filter media one at a time taking note of colour order. Black, Green, Blue, Grey. Gently tap the filter on a raised flat surface; this will cause the grey sediment to be displaced. Dispose of waste in compost heap or in a plastic bag in the garbage. Rinse each filer until you are happy that they are clean. Drain or sponge out the remaining residual in the very bottom of the Aqua2use GWDD tank. WARNING: DO NOT PUMP THE GREY RESIDUAL THROUGHT YOUR IRRIGATION SYSTEM. Reinstall the MATALA filters to the tank in colour order Black, Green. Green, Blue. Blue, Grey. For Pump systems close the drain fitting M and then reinstall the pump. For Gravity systems turn your drain valve to off, and remove your temporary drain and reconnect your irrigation system.

17. Refit the tank cover Q and refit the retaining clips to cover. 18. Finally turn diverting valve B to operate position allowing the water to be diverted into your unit. 19. Your unit is now serviced and ready for operation. At this time it is good practice to service your irrigation system. Turn on the drain valves at the end of your irrigation lines and remove and sediment that may have accumulated in the pipes. Check for any leaks or damage to the irrigation pipe-work. PUMP OPERATION OF YOUR AQUA2USE GWDD The Aqua2use GWDD unit is unique in that it comes with an electronic pump control (EPC). This pump control not only starts and stops the pump via the float level; it also is programmed to override the function of the high float switches at least once per day. This will ensure it will have little or no residual remaining in the unit. The EPC also avoids the use of an external clock which will easily be disrupted by temporary shutdown of electrical supply. No electrician is required and only one standard 10amp outlet is needed to be connected to operate the unit. All government departments are pushing for low or no residual water in Grey Water (Gray Water) Diverters. Your Aqua2use GWDD meets or exceeds these requirements. Pump Performance Table: Maximum flow of 130 lpm (34 gpm) at 1 metre head. (3-foot head) Rated flow of 65 lpm (24gpm) at 5 metres head. (16-foot head) Maximum current 1.2amps 240 volt. (2.5amps 115 volt): Cable length 4M (13 feet) Warranty is 12 months replacement, on condition that pump is returned to the factory for inspection. All pumps have a serial number. This allows for tracking of sales and warranty claims Make sure you keep your proof of purchase for any claims that may arise. To Start the Aqua2use GWDD Direct the diverting valve B to allow grey water (gray water) to divert into the unit.

Connect the power plug to 240V/50Hz or 115V/60Hz (pay attention to power specification which indicated in the colour box) power supply with surge protection. Note: This circuit must be protected by a residual circuit breaker and or by a Ground Fault interrupter GFI breaker. Your pump should need no further attention other than periodic cleaning along with the Matala filter mats. GRAVITY OPERATION OF THE AQUA2USE GWDD To start up the unit: Direct the diverting valve B to allow grey water (gray water) to divert into the unit. Ensure you have positioned the unit with enough height (head) to operate the irrigation system. Minimum requirements will have to be calculated out on site. Grey water (Gray water) will flow through the filters and out to your distribution system from the outlet M. Aqua2use GWDD Components Matala Water Technology Co., Ltd. Warrant this unit for a period of 12 months from

the date of purchase. On condition that all faulty parts or pump are returned to the manufacturer. Parts or pumps will be replaced or repaired upon inspection if deemed to be faulty if inside the warranty period and the fault was no caused by misuse. Incorrect installation or operation of your unit is not covered by warranty. Damages incurred to persons or property by incorrect operation or installation of your unit are not covered by this warranty. Warranty commences from date of purchase please provide proof of purchase with all warranty claims.