new fume hoods providing performance and protection

Similar documents
Fume Hoods Overview OVERVIEW

FUME HOOD SELECTION GUIDE

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

LABORATORY FUME HOODS

LABORATORY FUME HOODS

3.5 Exposure Control Measures

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

General Purpose Walk-In Fume Hood

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

General Purpose Walk-In Fume Hood

How to Use a Chemical Fume Hood Safely

January, 2014 Page 1 of 6

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

F. VAV hoods shall have a restricted bypass plate.

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

Bedcolab Vanguard Laboratory Fume Hoods

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

th Avenue Spring Lake, MI Ph:

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

CORPORATION DURALAB CORPORA

Thermo Scientific Hamilton Air Flow Products. Table of Contents

UNIVERSITY OF ROCHESTER DESIGN STANDARDS JANUARY 2012 SECTION FUME HOODS AND LOCAL EXHAUST SYSTEMS

Requires Ductwork and Blower

Element D Services Heating Ventilating and Air Conditioning ODG010107

The Green Solution Hood (Chemical Filtration) 2. Eliminator HP Series High Performance Energy Efficient Hood 6

Fume Hood Operation & Maintenance Manual

LABORATORY FUME HOODS OF 5

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

STATE UNIVERSITY CONSTRUCTION FUND

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

LABORATORY CABINETRY AND SPECIALTIES: FUME HOODS

Lab Safety & Energy Optimization. Introduction & Agenda

Protector XStream Laboratory Hoods

Frontier. Laboratory Fume Hood. Perfectly tailored solutions for your fume containment needs

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

Laboratory Fume Hoods & Enclosures

Design Standard - Fume Hoods & Fume Hood Exhausts

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

SECTION LABORATORY FUME HOODS

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

HEMCO. Laboratory Fume HoodsR

Laboratory Fume Hoods

Ductless Nanoparticle Containment Enclosures

Protector Airo Filtered Fume Hoods

AUDIO-VISUAL EQUIPMENT

Element D Services Heating, Ventilating, and Air Conditioning

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Products & Capabilities

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

AUDIO-VISUAL EQUIPMENT

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting

LABORATORY HOOD MANUAL

Supreme Air Fume Hood Option Availability

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Element D Services Heating, Ventilating, and Air Conditioning

USER'S GUIDE TO FUME HOODS. Procedures for Increasing the Effectiveness of Laboratory Hoods. Revised December, Hood Basics

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

High Performance Fume Hood Laminar Topography and Perfect Protection Perimeter

Laboratory Carts & Benches

Protector Laboratory Fume Hoods & Enclosures Overview

High Performance Fume Hood

Laboratory Fume Hoods & Enclosures

Pre-Wired and Pre-Piped

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

Completing Your Fume Removal System

Accessories Standard Service Fixture Kits

HEMCOR ISO 9001:2008 Certified Company

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

Compounding Safety Solutions.

Protector Demonstration Hoods

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

Laboratory Fume Hood

Esco Ascent Max Ductless Fume Hood

82863_Graphx_Conn:Layout 1 11/26/08 8:59 AM Page 1 DUCTLESS ENCLOSURES

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Air Sentry High Performance Fume Hood Operation & Maintenance Manual

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Protector Echo Filtered Fume Hoods

Other HEMCO Products. Installation, Operation, Maintenance Manual

Ductless mobile fume hoods with modular filtration column

High Performance Ductless Balance Enclosures

Clear Creek Business Center 187,865 Sq. Ft. OFFICE/FLEX/INDUSTRIAL

V05 General Purpose Bench Fume Hood

Thermo Scientific Hamilton Horizon Fume Hoods. Operation, Maintenance and Installation Instructions

High Performance Fume Hood Laminar Topography and Perfect Protection Perimeter

LABGARD FEATURES

Model ND-2 Specification

Polypropylene Total Exhaust Fume Hoods

Laboratory Fume Hood. Operation & Maintenance Manual APR 2005

Fume cupboards and extraction devices

Ductless Nanoparticle Containment Enclosures

W-VI Series - Internal Make-up Air Wall Canopy

Ventilated Balance Enclosures

Transcription:

new fume hoods providing performance and protection

five questions to get us started 1. Will the use of your hood require a special application hood? 2. How high of a priority is energy conservation? 3. What type of exhaust system will your hood be connecting to? 4. What size and type of hood do you need? 5. What sash configuration do you require?

things to consider as you choose Count on us to help you make smart and informed choices about fume hoods and the options that go under, over and inside them. plan with confidence: hood types Our hoods come in a variety of types designed for specific applications and can be made to match your specific size requirements in height and depth. These types include: bench, floor-mounted, ADA, distillation, teaching, double-sided and canopy. specialty hoods We offer hoods designed for many purposes. Whether you re testing and monitoring radioisotopes, handling perchloric/caustic acids or need clear viewing panels for student demonstrations, we will be able to offer a lab-tested solution. sash types Our chain-driven sashes include vertical, combination and split-postless designs. To meet your unique needs, horizontal-sliding sashes or a variety of tailored configurations are also available. work surfaces Select from epoxy resin in a variety of colors, stainless steel or heavy-duty polymers. Sink options include multiple sizes, colors and mounting configurations. optional features Complement your fume hood s functionality with a wide variety of available options including: alarms, apparatus rods, tissue screens, sash stops, sash pockets, self-lowering sash mechanisms, automatic sash operators and pass-throughs. plumbing fixtures Our front-loaded plumbing valves for water, air, vacuum and a full complement of laboratory gases are designed for exceptional serviceability. Valves are color-coded and can be factory installed to facilitate quick and efficient installations. base configurations We offer a full line of cabinets and tables that are designed as perfect base components for your fume hoods: table bases, insulated cabinets for solvents and flammables, corrosion resistant acid cabinets, vacuum pump cabinets or additional storage space. Whatever the need, we can provide the right option.

standard versatile, reliable understanding your fume hood. A fume hood properly designed, manufactured, installed and operated will deliver a safe working environment to laboratory personnel. Each of our fume hoods are designed and built to enhance the laboratory experience while protecting the user within the lab. Our hoods are built to SEFA requirements, tested to ASHRAE-110 and can be UL listed. We provide a variety of hoods styled for different environments that can feature a chain and sprocket sash system, front-loaded valves, energy-efficient options and ergonomic designs. With over 25 years experience in the lab construction industry, New England Lab can help ensure the proper integration of hoods with the mechanical system of the lab. We offer a wide array of options and accessories to adapt your fume hood to your particular industry and will guide you through the process to help you choose wisely. Pro Series Fume Hood The Pro Series hood has been engineered for both performance and economical savings, making it our most requested model. Pro Series hoods come standard with stainless steel high performance airfoils and a durable chain and sprocket sash system. The Pro Series product line is available in a variety of configurations from bench mounted to floor mounted to ADA, in addition to special applications such as distillation, percholoric acid and radioisotope.

heavy duty ergonomic strength enhanced efficiency stylish containment Harvard Series Fume Hood Our Harvard Series hood is designed with some high-end features such as a heavy-duty steel frame that adds strength to the hood structure. This hood also has ergonomically angled front posts that point the service handles and electrical outlets towards the operator. A glass by-pass panel is standard on this model in order to provide full sight lines within the hood. Also standard are high-performance stainless steel airfoils and durable chain and sprocket sash systems. This hood is ideally suited for use with VAV (Variable Air Volume) exhaust systems. Safeguard Series Fume Hood The Safeguard Series hood is developed for aesthetics, ergonomics, and energy efficiency. This hood has been designed with a smooth front panel for a more modern look. An epoxy-coated stainless steel flush airfoil flips up for easy access to the spill containment trough. Our standard chain and sprocket sash mechanism delivers the easiest and most reliable sash operation available with an exceptionally long lifespan. When released, the self-lowering sash automatically returns to 18 to further protect the user and conserve energy. Our 34 high viewing sash provides a clear and unobstructed view of the fume hood interior.

high performance energy savings instructional maximized visibility RFV2 Series Fume Hood The RFV2 (Reduced Face Velocity) Series hood is specifically designed for high performance and energy efficiency. This fume hood has been successfully tested to both standard and modified ASHRAE procedures at face velocities as low as 50 fpm. The unique rear baffle system combined with the performance sash handle and downwardly vectored airflow provide safe containment at low face velocity without the need for mechanical baffle systems or fans. The standard features include a flush sill with containment trough, a reliable chain and sprocket drive mechanism, and a self-lowering sash with full 34 high viewing. Observation2 Series Fume Hood The Observation2 Series hood was specifically designed to meet the needs of students and teachers. By combining side and back viewing windows, narrow posts and a 5 angled sash, enhanced visibility is achieved for both instruction and observation. Pre-plumbed in the factory, you can choose up to eight services. Available in single or double-sided configurations, this hood features low profile airfoils, a high quality stainless steel cable sash drive system and a spill trough for secondary spill containment. It comes with an 18 self-lowering sash for extra protection and for increased energy efficiency. This hood is suitable for non-corrosive teaching environments.

specialized fume hoods variable conditions delivering the right hood. NOVAGUARD Series Fume Hoods With a popular demand of maximized visibility, the NovaGuard Series hood has a 44-2/2 viewing area and optional side glass windows. A self-lowering sash system, flush sill airfoil and 5 angled sash come standard. Preplumbed fixtures within the alcoves allow for a fully utilized interior width. At New England Lab, we know that your satisfaction with a fume hood depends upon us listening to you, understanding the requirements of your lab and delivering upon that understanding. Trust our experience to help determine which hood best suits your needs. Hoods can be constructed in a multitude of sizes and configurations. Some hood types include: Bench Mounted Floor Mounted ADA Specified Distillation Teaching Double-Sided Polypro Series Fume Hoods The Polypro Series hoods are extremely durable and highly resistant to corrosives. The seam-welded, light-weight construction has no exposed metals and is easily cleanable and stain resistant. With bonded thermal plastic construction, the Polypro hoods are ideally suited for acid digestion, aqua regia and other wet and corrosive applications. Our line of fume hoods is designed to meet a variety of specialized applications such as: Radioisotope Perchloric Acid Demonstration Acid Digestion Class 1 Div. 1 & 2 Hydrofluoric Acid Hoods must also tie in to various mechanical systems including HVAC, electrical and plumbing. Some hood Ductless Fume Hoods operations to consider include: Constant Volume (CAV) Low Constant Volume Our filtered and ductless hoods are designed to protect the user and the environment from hazardous vapors and can offer significant operational cost savings. Filtered hoods feature specially formulated filter technology with computer controls and redundancy for the most intense chemical filtered applications. Contact your New England Lab Representative to determine if this solution safely meets your needs. Restricted By-Pass (VAV) High Performance For further assistance in selecting your fume hood, contact one of our experienced lab furniture specialists at 888.635.2080 or newenglandlab.com.

new labs: Lab tested means three fundamental things: we ll understand what matters to you, take pride in our craft and products, and deliver service that makes your new lab right. As you consider our guides for casework, furniture systems, fume hoods and the accessories that accompany them, look to New England Lab for consultation to help you choose the products that best fit your lab needs. furnished with understanding crafted with precision made right with service New England Laboratory Casework Co., Inc. P 888.635.2080 F 781.932.9981 Baltimore Boston Raleigh Richmond newenglandlab.com