Airscrew 5 to 17 Vmax Vaneaxial Fans General Vaneaxial Information Vmax Vaneaxial Fans comprise a combination of rotating impeller and stationary guide vanes, housed within an axial duct known as the fan case. The function of the guide vanes is to increase the pressure capability of the fan. Higher aerodynamic efficiencies are achieved with true airfoil blade designs. These fans typically operate up to the aerodynamic stall point. The axial configuration allows easy installation into ducted systems, with cooling air passing over the integral motor, allowing compact motor design with high power demand in small packages. The Vaneaxial designs are suitable for operation in severe environments, including sand scavenge applications. Vmax Fans are available in AC or DC supply configuration and can be supplied with thermal protection, speed sensing and customized interfaces. 17 Vmax Fan 17 Vmax Series: imum Performance Curve* 1... Static Pressure (inches water gauge)... RPM.. Airflow (cfm) *Individual Performance Curve Characteristics Available Upon Request General Physical Envelope:.9 x Ø.9 (17mm x Ø17mm) Weight: 7.1lbs. (.Kg) Airflows up to 195 CFM (l/s) Static Pressures: up to. IWG (.kpa) Designed to Mil Specs Suitable for Sand Scavenge Applications Options/Accessories Speed Sensors Thermal Sensors Materials and Finishes Aluminium alloy anodized dyed black impeller, guidevanes and case Stainless steel SD shaft High precision, sealed ABEC 7, maintenance free bearings Stator wound to class H insulation Stainless steel blades for sand scavenge applications Chrome impeller track for erosion protection Thermal Protection Finger Guards -
Unit Description Key The unit description key is for reference only and should not be confused with a part number. While most units are custom configurations, not all variations of the key shown below are possible. Please contact the Application Engineering department for more information regarding possible custom configurations. 5 A A 1 5 1 1 REPRESENTS A DESIGN STAGE OF THE FAN (EX: THIS NUMBER WILL CHANGE WITH MODIFICATIONS IN THE UNIT, AFFECTING INTERCHANGEABILITY BUT NOT USUALLY PERFORMANCE) REPRESENTS A PARTICULAR ITEM OR DESIGN WHEN ASSOCIATED WITH THE PRECEDING NUMBER ELECTRICAL SUPPLY OR DRIVE: 1 = VOLTS DC = (NOT YET ALLOCATED) = 1 VOLTS DC 7 = BELT DRIVE = HYDRAULIC DRIVE = DIRECT DRIVE WITH INTEGRAL BEARINGS = / Hz AC 9 = (NOT YET ALLOCATED) 5 = Hz AC = TURBINE DRIVE AIRSCREW AERODYNAMIC DESIGN REFERENCE FAN CONFIGURATION A = AXIAL (EX: AIR DISCHARGE AXIALLY) C = CENTRIFUGAL (EX: AIR DISCHARGE CENTRIFUGAL) P = PARTITION-MOUNTED (EX: WITH FREE DISCHARGE, NOT ARRANGED FOR DUCTED OUTLET OR INLET) IMPELLER TYPE: A = AXIAL C = CENTRIFUGAL M = MIXED FLOW IMPELLER DIAMETER IN MILLIMETRES (IN THE CASE OF MIXED FLOW USE THE MEAN OUTLET DIAMETER) EXAMPLE: 5, AA1, 551 WHERE: 5 = 5MM IMPELLER DIAMETER, A = AXIAL IMPELLER, A = AIR DISCHARGE AXIALLY, 1 = AERODYNAMIC DESIGN REFERENCE, 5 = Hz AC LINE ELECTRICAL SUPPLY, 1 = FIRST INSTALLATION DESIGN STAGE Ordering Information When ordering, please specify the specific Airscrew part number listed on the following model table. Further ordering information, based on the configuration and motor series, may be obtained by contacting customer service. Please refer to the Unit Description Key explanation above. -7
Standard Product Offering of AC Line Powered Models Part # Prod Description FLOW (CFM) Pressure (IWG) RPM Watts Line Amps (A) Amb (C) Weight (lbs) Phase Hz Volts Airflow Source Data 95 MOD 71. 17. 7. AS5-19 119 5.55 7.55 1. 7 5.5 AS1-11 1-AA-5-1 77 11. 11 17.5 7.9 AS1-1-AA-5 77. 11.1 1 5.7 7 11.9 AS1-1 15-AA1-51 11. 11.59.7 7 1. AS5-1 59 -AA-511. 11. 9.5 7 5. AS1-19 71 MOD 17.7 1 7.7 AS1-5 Standard Product Offering of DC Line Powered Models Part # Prod Description FLOW (CFM) Pressure (IWG) RPM Watts Line Amps (A) Amb (C) Weight (lbs) Volts Airflow Source Data 1 5-AA-11 5 9. - 7 7.75 AS- 1.5. 119.5 5 5. AS5-9-1. 5.7 9.7 75 5.7 AS5-17 71 Mod 1. 5.7 9.7 7 5. AS5-17 71 Mod 1 1.7.1 7.9 7 5. AS- 17 Vmax Fan * *Part Number Specific Drawings Available Upon Request -
P/N 95 MOD AS5-51.. 15.9 5.71 57.1.57 P/N 19 119 AS1-11.57 17.1 5.71 7.9. 11. 1 57 7 19 57 7 9 7 1 7 AIR FLOW - CFM at.75 lbs/ft³ DENSITY AIR FLOW - CFM at.75 lbs/ft³ DENSITY P/N 1-AA-5-1 AS1-.57 17.1 5.71 7.9. 11. 1. 9. 7... 1 P/N 1-AA-5 AS1-1.57 17.1 5.71 7.9. 11.. 5 17. 1 1.... 5 55 17 5 19 57 7 9 19 57 7 9 1 AIR FLOW - CFM at.75 lbs/ft³ DENSITY 1 7 AIR FLOW - CFM at.75 lbs/ft³ DENSITY P/N 15-AA1-51 AS5-1.57 57.1 5.71 51.9. 771. 9 1 15 9 75 5 75 P/N 59 -AA-511 AS1-. 1.71.57 7..9 1.1. 7.. 1.. 7 1 AIR FLOW - CFM at.75 lbs/ft³ DENSITY 19.. 57. 7. 9 1 AIR FLOW - CFM at.75 lbs/ft³ DENSITY -9
P/N 19 71 MOD AS1-5.57 57.1 5.71 51.9. 771. 9 1 P/N 1 5-AA-11 AS-. 5.71.57 171. 171.9 57.1. 7 9 7. 5.. 1. 5 1 15 9 5 7 1 9 19 5 17 55 AIR FLOW - CFM at.75 lbs/ft³ DENSITY 5 15 AIR FLOW - CFM at.75 lbs/ft³ DENSITY P/N AS5-17.1.9 51..57 5.71. 5 9 1 5 75 5 P/N 9-1 AS5-17 17.1.9 51..57 5.71. 9.... 1. 1 9 1 19 5 AIR FLOW - CFM at.75 lbs/ft³ DENSITY 9 1 19 AIR FLOW - CFM at.75 lbs/ft³ DENSITY P/N 71 Mod 1 AS5-17.1.9 51..57 5.71. 9.... 1. 1 P/N 17 71 Mod 1 AS- 17.1.9 51..57 5.71. 7 5 7 9 1 5 75 5 9 1 19 9 1 19 AIR FLOW - CFM at.75 lbs/ft³ DENSITY 7 CONSULT FACTORY FOR DATA AIR FLOW - CFM at.75 lbs/ft³ DENSITY -9
NOTES: -91