ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

Similar documents
Power drill Center punch Wire stripper

7100SZ Series SafeZone Installation and Instruction Manual

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

5600 Series Power Operator Installation and Instruction Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

WARNING: Make sure that (120V, 60Hz) input power is turned off at facility s main circuit breaker before proceeding with installation.

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

TS93 EMF T/PT/TDE. Surface applied door closer

Installation Instructions Series 78-B/FHA Hold Open

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Installation Instructions CAUTION

ASSA ABLOY Universal Door Closers

KEANE MONROE a member of the record group

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

Installation Instructions (07-08) CAUTION

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

NON-SIZED SIZED HANDED

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

9000 Series Trinity The world's most intelligent door closer

NON-SIZED SIZED HANDED

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

CONCEALED CLOSER SERIES

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

51 Series Door Closers. An ASSA ABLOY Group brand

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

CONCEALED CLOSER SERIES

5300 Series 5300 SERIES

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

Installation Instructions. Non Hold Open Models. Sized (Sizes 2,3,4,5) Weaker BC 9303BC 9304BC 9305BC. Stronger +

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

Superior door control for rigorous, high-use applications 6000 LOW ENERGY OPERATOR CATALOG

HIGH SECURITY CLOSERS SERIES

High Security Closers Series

Door Controls DOOR CLOSERS

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

HIGH SECURITY SERIES

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

51 Series Door Closers. An ASSA ABLOY Group brand

5200 Series

D O O R C L O S E R S

6900 PowerMatic Low Energy Power Operator Installation Instructions CAUTION CAUTION WARNING

High Security Closers Series

78-B/F Series. Traditional Door Closers

7570 SERIES Security Door Closer

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

NON-SIZED SIZED HANDED

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

LCN 9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

9550 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING

6900 Series PowerMatic. Low Energy Power Operator

LCN 4010T SERIES HINGE (PULL) SIDE

6900 Series PowerMatic Low Energy Power Operator

Copyright , 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

9540 SERIES. Cast Iron Door Closer

1600 SERIES ALUMINUM STOREFRONT DOOR CLOSERS

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

D o o r C l o s e r s

Installation Instructions

LCN Super Smoothie Adjustable Closer Super Smoothie Adjustable Closer

An ASSA ABLOY Group brand. 400/4400 Series. Institutional Door Closer

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

Handy Lift LT Owners Manual

4310ME Series. Features E25. Special Templates. Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101

*PULL SIDE mount shown

9560 Series Senior Swing. Features. Special Templates. Cover Fasteners Mounting. Certifications

SERIES 1370 DOOR CLOSERS

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

Hunter Automatics HA-8. Installation Manual

*4110 HCUSH mount shown

Handy Lift HD Owners Manual WARNING. BURR 500 lb. Capacity Handy Lift HD PN (40 ) PN (45 ) PN (50 )

4310ME Series. Features E25. Special Templates. Certifications. Cover Fasteners Mounting Arms

Multi-sized cast iron closer for high use applications DOOR CLOSER CATALOG

*HINGE (pull) side mount shown

*CENTER PIVOT arm shown

LCN 2810 SERIES OPERATOR MOUNTS SINGLE DOOR, OVERHEAD CONCEALED CENTER PIVOT ARM OFFSET PIVOT/BUTT HINGE

Transcription:

Pull Side Applications with Slide Track (7210, 7250) (see page 7 for template) 7200 Series Multi-Point Hold Open Installation and Instruction Manual 3 1 Push Side Applications with Double Lever Arms (7220, 7230) (see page 2 for template) 2 Item No. Description 1 Track (Pull Side) 2 over 3 Track Arm (Pull Side) 4 Double Lever Arm (Push Side) Tools required: Allen wrench set (inch) Flat blade screwdriver (potentiometer & terminal size) Screwdriver (Phillips size 2) Tape ruler Power drill enter punch Wire stripper Use screw pack and hardware provided to mount operator. Requirements: Units are handed. Hand of unit and hand of door must be the same. All dimensions shown in inches (mm). Door must be hung on ball bearing butt hinges or 3/4" (19) offset pivots. Door thickness must be 1-3/4" (44) to 2-1/4" (64). Door must swing freely through the entire opening and closing cycle before beginning the installation procedure. Frame face must be a minimum of 2" (51). eiling clearance must be a minimum of 3-1/2" (89) for push side application or 4" (102) for pull side application. See pages 2 and 7 for templates. Power input to unit must be of the same voltage as that stated on the unit. Unit to be mounted on interior of building in dry environment, maximum humidity of 95%. See NFPA70 for wiring requirements and NFPA72 for alarm system requirements. 4 Table of ontents: Push Side Template...2 Push Side Installation...2-4 loser Adjustments...5 Hold Open Position Adj...6 Pull Side Template...7 Pull Side Installation...7-9 loser Adjustments...10 Hold Open Position Adj...11 Non-Detectored Electrical...12 Detectored Electrical...13 RF Unit Electrical...14-15 Troubleshooting...15 General Information...16 opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 1

Double Lever Arm (Push Side) Use of an auxiliary door stop, by others, is required for these applications. eiling Line 3-1/2 Min (89) 2 Min (51) RH - Right Hand LHR - Left Hand Reverse Hinge Edge Of Door LH - Left Hand RHR - Right Hand Reverse 1 Prepare Frame Drill #7; Tap 1/4-20 UN 4 (101.6) A 11-1/4 (285.8) 5/16 (7.9) 19-3/4 (501.7) 11/16 (17.5) 7/8 (22.2) 7/8 DIA THRU (22.2) For oncealed Wiring Only Frame Rabbet Top of Door B Hinge or Pivot 1-3/4 (44.5) 1-5/8 (41.3) Left hand door shown, right hand opposite. All dimensions shown in inches (mm). 1-3/4 (44.5) DOOR OPENING ANGLE To 100 100 to 180 Frame Soffit Dim A Inches 5-7/8 3-1/8 (mm) 149.2 79.4 Dim B Inches 13-3/8 10-5/8 (mm) 339.7 269.9 2 loser Mounting Install two screws in the key slot locations leaving gap between screw head and frame face as shown (a). a opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 2

3 Operator Mounting Hang closer body by key hole slots (b) and slide closer toward hinge to capture screw heads (c). Warning: Do not allow pedestrian traffic through opening until all mounting screws are tightened. b c 4 loser Mounting Install remaining mounting screws through back plate and tighten all four screws (d). Pull wiring through holes (if concealed wired). d For oncealed Wired Only (If surface wired, see page 13-15) 5 Arm Shoe Mounting Mount closer arm shoe to door face as shown. opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 3

36 Attach Arm Main Arm F L R F 37 Arm Screw (7/16 Drive) Preload loser Spring Arm Mark Y S Z Pinion Flat Align the pinion flat with the letter "S". With the door closed and latched, rotate main arm until secondary arm is perpendicular to the door frame, then tighten adjustment screw as shown with 7/16 wrench. 90 38 loser Spring Adjustment losing Force + Stronger 11/16" Wrench Weaker Slowly increase closer power until door closes consistently. A closer set to the ADA required 5 lbs opening force may not be strong enough to close the door due to latching hardware, air pressure, or frame issues. opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 4

39 loser Adjustments losing Speed ontrols Valve "S" ontrols Sweep Range from full open to 5. Valve "L" ontrols Latch Range from 5 to closed. Opening ycle Valve "B" controls the strength of cushioning in Backcheck Range. NEVER close this valve completely it is not to provide a positive stop. Valve "P" adjusts the angle that backcheck is felt in the open cycle. "S" Sweep 5 Slower F Hex Key r aste "L" Latch 5 0 Slower F Hex Key r aste Hex Key "B" Backcheck - + Stronger Weaker 75 Never lose backcheck valve completely "P" Backcheck Position Hex Key 90 75 Do not remove valves from closer. Hydraulic oil will escape. 10 3 Electrical onnections See Page 13 for Non-Detectored Units See Page 14 for Detectored Units See Page 15 for RF Units opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 5

11 3 Selective Hold Open am Adjustment Setting Hold Open Angle Make all required electrical connections and turn power switch to on for nondetectored units (detectored units cannot be turned off at the closer). (See previous step) Open door to desired hold open angle. b 5/32 hex wrench Loosen cam screw and rotate cam until switch closes and door holds open. Rotate cam until it touches the switch. a Tighten cam screw but do not over torque as this will cause damage to cam. Force door out of hold open by closing the door, then test hold open by opening to hold open angle again. c d Backplate 5/32 hex wrench e SHO switch in open position. loser not in hold open. Right hand pull-side shown. Switch shown in hold open position (closed). Un-used pin SHO switch in closed position. loser in hold open. 12 3 Attach over Attach cover using screws provided. opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 6

Track Mount (Pull Side) eiling Line 4 Min (102) 2 (51) Min RH - Right Hand Door LHR - Left Hand Reverse Left Hand Door - LH Right Hand Reverse - RHR 1 3/4 (19) Prepare Frame Prepare holes for mounting per instructions on page 2. *Track screws are self tapping and are smaller than closer mounting screws* 23 (584.2) 14-1/2 1-1/16 1-3/8 (368.3) (27) (34.9) 3-1/4 (82.6) 7/8 (22.2) 7/8 DIA THRU (22.2) For oncealed Wiring Only Frame Soffit Top of Door 6 (152.4) A Track Mount Unit 19-1/8 (485.8) 1-3/4 (44.5) 1/8 gap (3.2) *9/64 (3.6) Holes for track screws* Hinge or Pivot Series Standard Arm Double Egress Arm Dim "A" 5/8 (15.9) 1-1/4 (31.8) Right hand door shown, left hand opposite. All dimensions shown in inches (mm). 2 loser Mounting Install two screws in the key slot locations leaving gap between screw head and frame as shown (a). a opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 7

3 loser Mounting Hang closer body by key hole slots (b) and slide closer toward hinge to capture screw heads (c). Warning: Do not allow pedestrian traffic through opening until all mounting screws are tightened. b c 4 loser Mounting Install remaining mounting screws through back plate and tighten all four screws (d). Pull wiring through holes (if concealed wired). d For oncealed Wired Only (If surface wired, see page 13-15) 5 Arm Mounting Use main arm to rotate pinion until flat is visible. Align the pinion flat as shown. RIGHT HAND LEFT HAND Fully close Latch & Sweep Valves with wrench provided. 36 Attach Arm Attach with provided screw and washer. Tighten arm screw with 5/32" hex wrench. RIGHT HAND Mount closer arm to pinion square as shown. RE-INSTALL HERE *All views from floor looking upward* LEFT HAND PINION FLAT *For onnected Free Swing Arm see Instructions 80-9372-0101-000* opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 8

37 Mount Track If opening angle greater than 125, spring cushion stop cannot be used and an auxiliary stop by others is required. Set Screws toward hinge D B A) Insert slider into track. B) For openings 125 or less, insert spring cushion stop on hinge side of track. For openings greater than 125, omit spring stop. A ) Insert end caps (both ends). D) Secure track to door using screws provided. E) Snap on cover. E 38 onnect Arm to Track Secure arm to slider assembly using 3/16" wrench. Turn wrench counter clock wise to tighten. HINGE Open Latch & Sweep Valves with wrench provided. Open door to maximum desired swing minus 5 and hold. Slide spring cushion stop assembly against slider assembly and secure to track using 5/64" or 2mm wrench. 39 loser Spring Adjustment losing Force + Stronger 11/16" Wrench Weaker Slowly increase closer power until door closes consistently. A closer set to the ADA required 5 lbs opening force may not be strong enough to close the door due to latching hardware, air pressure, or frame issues. opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 9

10 3 loser Adjustments losing Speed ontrols Valve "S" ontrols Sweep Range from full open to 5. Valve "L" ontrols Latch Range from 5 to closed. Opening ycle Valve "B" controls the strength of cushioning in Backcheck Range. NEVER close this valve completely it is not to provide a positive stop. Valve "P" adjusts the angle that backcheck is felt in the open cycle. "S" Sweep 5 Slower F Hex Key r aste "L" Latch 5 0 Slower F Hex Key r aste Hex Key "B" Backcheck - Weaker + Stronger 75 Never lose backcheck valve completely "P" Backcheck Position Hex Key 90 75 Do not remove valves from closer. Hydraulic oil will escape. 11 3 Electrical onnections See Page 13 for Non-Detectored Units See Page 14 for Detectored Units See Page 15 for RF Units opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 10

12 3 Selective Hold Open am Adjustment Setting Hold Open Angle Make all required electrical connections and turn power switch to ON for nondetectored units (Detectored units cannot be turned off at the closer). Open door to desired hold open angle. Loosen cam screw and rotate cam until switch closes and door holds open. Rotate cam until it touches the switch. b 5/32 hex wrench Tighten cam screw but do not over torque as this will cause damage to cam. a Force door out of hold open by closing the door, then test hold open by opening to hold open angle again. c d 5/32 hex wrench e Right hand pull-side shown. Switch shown in hold open position. SHO switch in open position. loser not in hold open. Un-used pin SHO switch in closed position. loser in hold open. 13 3 Attach over Attach cover using screws provided. opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 11

NON-DETETORED ELETRIAL ONNETIONS Power input to unit must be of the same voltage as that listed on the label. All wiring connections use standard wiring practice conforming to local wiring codes. Maximum wire size is 18AWG. Make input power connections to the terminal block or power supply using illustrations below. Surface mount power input: Remove appropriate shaded area from cover for surface wired installations only. Repaint cut edges as necessary to prevent corrosion. 7/8" 7/8" learance For Strain Relief 2-5/8" over surface facing ceiling. Stand-Alone wiring instructions below. (To incorporate other devices, see included wiring instruction manual: 80-9342-0904-000) 120V A INPUT Make power connections as shown below. aution: Determine proper input power; 24V or 120V. On/Off Switch To Power Supply Ground Neutral Live Terminal Block Make onnections Here 24V D INPUT Make power connections as shown below. On/Off Switch 24V(+) 24V(-) Terminal Block Make onnections Here opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 12

SMOKE DETETOR ELETRIAL ONNETIONS Power input to unit must be of the same voltage as that listed on the label. All wiring connections use standard wiring practice conforming to local wiring codes. Maximum wire size is 18AWG. Make input power connections to the terminal block or power supply using illustrations below. Surface mount power input: Remove appropriate shaded area from cover for surface wired installations only. Repaint cut edges as necessary to prevent corrosion. 7/8" 7/8" 120V A INPUT Make power connections as shown below. learance For Strain Relief over surface facing ceiling. 2-5/8" Stand-Alone wiring instructions below. (To incorporate other devices, see included wiring instruction manual: 80-9342-0904-000) aution: Determine proper input power; 24V or 120V. On/Off Switch Power Supply Ground Neutral Live Terminal Block Make onnections Here 24V A/D INPUT Make power connections as shown below. 24VD Input Power Only Test/Reset Switch 24V(+) 24V(-) Terminal Block Make onnections Here opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 13

RF REMOTE REEIVER UNITS ELETRIAL ONNETIONS Power input to unit must be of the same voltage as that listed on the label. All wiring connections use standard wiring practice conforming to local wiring codes. Maximum wire size is 18AWG. Make input power connections to the terminal block or power supply using illustrations below. aution: Determine proper input power; 24V or 120V. Surface mount power input: Remove appropriate shaded area from cover for surface wired installations only. Repaint cut edges as necessary to prevent corrosion. 7/8" 7/8" learance For Strain Relief 2-5/8" over surface facing ceiling. 120V A INPUT Make power connections as shown below. 12-24V A/D OM NO N On/Off Switch Power Supply Ground Neutral Live Terminal Block Make onnections Here 24V A/D INPUT Make power connections as shown below. 12-24V A/D OM NO N On/Off Switch 24V(+) 24V(-) Terminal Block Make onnections Here opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 14

Troubleshooting SYMPTOMS PROBABLE AUSE ORRETIVE Door holds open but at the wrong angle. am switch engaged too early or too late. am switch shorted. PROGRAMMING RF REMOTE REEIVER UNITS DIP SWITH SETTINGS # 1 DESRIPTION FUNTION OFF Pulse Relay Press the transmitter once and the relay will be active momentarily. ON Toggle Relay Door does not hold open. Door not closing when Test/Reset switch depressed. (Detectored units only) Press the transmitter once and the relay output is active indefinitely, press it again and the relay will de-energize indefinitely. # 2 DESRIPTION FUNTION (Pulse Mode Only) OFF 0.5 sec Hold Time Relay will remain active 0.5 second after the loss of activation. ON 10 sec Hold Time Relay will remain active 10 seconds after the loss of activation. HAND HELD ONFIGURATION No power to unit. Loose wire connection. am switch not engaged. Wiring incorrect. Short circuit across Test/Reset switch. PUL TOG ON 1 2 0.5s l 10s PUL TOG ON 1 2 ATION heck input voltage: 24VD or 120VA Inspect wiring for loose connections. Adjust am position (see pg. 6 or 11) Adjust am position (see pg. 6 or 11) Inspect am switch wiring for short circuit. Inspect wiring (see pg.13-15). Inspect Test/Reset switch for short circuit. 0.5s l 10s In Toggle Setting (1-ON), the Hold Time is inactive. Either setting for #2 dip switch will have the same result. PUL TOG ON 1 2 0.5s l 10s 0.5 second Pulse Setting PUL TOG ON 1 2 0.5s l 10s 10 second Pulse Setting 1. Set dip switches on the receiver to the desired activation cycle (dip switch 1 -Toggle or Pulse and dip switch 2-0.5s or 10s hold). 2. Press either Learn w/delay Button or Learn w/no Delay Button on the receiver depending on the activation requirements (If delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay). After learn cycle is complete, adjust potentiometer to desired delay time (0-30 sec). 3. Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from transmitter). NOTE: Repeat Steps 2-3 to program additional transmitters. 4. To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED illuminates on the receiver. This indicates that the relay has been activated. PUSH PLATE ONFIGURATION 1. Before beginning, it is easiest to have already prepared the installation of the pushplate. 2. onnect the wires from the transmitter to the NO and OM contacts of the pushplates switch. 3. Follow Steps 1-4 (Hand-Held onfiguration); depress the pushplate to activate the transmitter. 4. Attach the transmitter to the inside of the electrical box and complete the installation. REMOVING TRANSMITTER ODE(S) SINGLE TRANSMITTER ODE 1. Press both DELAY and NO DELAY BUTTONS simultaneously until Red LED flashes once (approximately 1 second). 2. Press transmitter button twice within 10 seconds and the transmitter code will be deleted. ALL TRANSMITTER ODES 1. Press and hold both DELAY and NO DELAY BUTTONS simultaneously until Blue LED illuminates then release (approximately 10 seconds). DETETORED AND NON-DETETORED UNITS SYMPTOMS PROBABLE AUSE ORRETIVE Red LED flashes on RF unit and can t program receiver. Receiver intermittently doesn t receive the transmitter signal. RF UNITS Push plate stuck or faulty transmitter. Receiver antenna wire is too short TERMINAL STRIP DIP SWITH LEARN WITH DELAY BUTTON ANTENNA WIRE BLUE LED RED LED ATION LEARN W/O DELAY BUTTON DELAY POTENTIOMETER (Time Adjustment) Disconnect each push plate or remove batteries until LED goes out. Replace faulty push plate. Add 6 3/4 lengths of wire to antenna until it receives signal. For problems not listed here, see page 16 for Technical Product Support ontact info. opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 15

General Information loser/holder Unit Assembly (Handed) MPSO Test/Power Switch MPDO loser/holder Unit Assembly (Handed) Test/Power Switch Power Supply (120V units only) Backplate Smoke Detector Backplate Power Supply (120V units only) Backplate Mtg Screw (4) Backplate Mtg Screw (4) over over Mtg Screw (6) over over Mtg Screw (6) Included with Pull Side or Double Egress Slide Track (7100-1T) 7110 Main Arm (7110-1A) 7150 Main Arm, Handed (7150-1L: Left Hand 7150-1R: Right Hand) Fasteners 1/4-20 machine screw Self tapping screw (Track screws only) Preparation for Fasteners Door or Frame Drill-Sizes Drill: #7 (0.201 dia.) Metal Tap: 1/4-20 Metal / Wood Pre-Drill: 9/64 hole Track End ap (2) ushion Stop Assembly (7100B) Track Mtg Screw (2) Included with Push Side Track over Slide Assembly (7100SLD) Standard Self tapping screw (loser mounting screws only) Sleeve nuts and bolts (Shoe screws only) Metal / Wood Hollow Metal Aluminum or Wood Pre-Drill: 3/16 hole 9/32 (7 mm) through; 3/8 (9.5 mm) door face opposite to closer 3/8 (9.5 mm) through 7120 Arm Assembly (7701-1A) Arm Screw (7701-MAS) 7130 Arm Assembly (7701-1B) Optional Through-bolts and grommet-nuts All 9/32 (7 mm) thru; 3/8 (9.5 mm) dia. x 3/8 (9.5 mm) deep on door opposite to closer ertifications UL228, UL10B 3000 Highway 74 East Monroe, N 28112 Tel: (877)- 974-2255 Fax: (800)-338-0965 www.nortondoorcontrols.com opyright 2010, 2014 Yale Security Inc., an Group company. All rights reserved. 16