Visual comparison of Plain & Hazy PP Film

Similar documents
Technical Specification For Outdoor Substation Harmonic Filter Banks

EMPAC Metal enclosed capacitor bank for wind applications

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

CP Automatic capacitor bank

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Technical Specification for Pole Mounted Capacitor Rack

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Q pole Pole Mounted Capacitor System

C1000 Series Automatic Cap Bank

Power Factor Correction Equipment

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

LV Capacitor CLMD Reliability for Power Factor Correction

High Reliable Components for Power Factor Correction and Power Quality

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

HARYANA VIDYUT PRASARAN NIGAM LTD.

THE PROTECTION OF INDUSTRIAL CAPACITOR BANKS BY CURRENT LIMITING FUSES. By M.J. Smart and B. Wadcock

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

POWER CAPACITORS. Cylindrical capacitor standard duty

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Air-insulated switchgear UniGear type ZS1

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager

GROUP D. Switch & Protective device.

AF series contactors (9 2650)

LV Capacitor CLMD03 Power Module Instruction manual

Power System Solutions (PSS)

PhiCap Capacitors for Power Factor Correction

CLMD Low-voltage capacitors for reliable power factor correction

AF series contactors (9 2650)

Distribution transformers Efficiency over life-cycle

DYNACOMP. The top-class reactive power compensator

Medium Voltage Metal-Enclosed Switches

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

B kv T&D GAS INSULATED SWITCHGEAR

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

LV Capacitor Bank APC

Beaver Power Factor Correction Capacitors

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 240 Kvar

Medium Voltage Metal-Enclosed Switches

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

MV capacitors banks and accessories

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

Technical Information

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar

MODVAR Low voltage reactive power compensation modules Installation manual

Medium Voltage Capacitors

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

multicond Power capacitors Data sheet: multicond

FUSES. Safety through quality

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

LV Capacitors QCap-L series Capacitors for power factor correction

MSD TM MEDIUM VOLTAGE CAPACITORS ELECTRONICON KONDENSATOREN GMBH GERA GERMANY

MV POWER CAPACITORS AND BANKS. All film dielectric MV Power Capacitors QUALITY MADE IN ITALY

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Capacitor Switching Contactors Type K3...-A, K3...-K

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SUBSTATION DESIGN TRAINING

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Vacuum Circuit Breaker

8DJ. Maintenance-free for lifetime

Medium voltage products. Fuses

Trifazni kondenzatorji KNK

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Power factor correction Harmonic filtering Dynamic flicker compensation

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

KOREA INDONESIA COMPANY NAME SAMWHA CAPACITOR CO., LTD. ESTABLISHMENT AUGUST 1956 HEADQUARTER USD10,000,000 CAPITAL REVENUE USD150,000,000 (2009)

EE 741 Over-voltage and Overcurrent. Spring 2014

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

Extensible Unit - VCE2a

MEDIUM VOLTAGE METAL ENCLOSED CAPACITOR BANKS

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

OTEC Transfer switch open transition

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

3NP1 Fuse Switch Disconnectors up to 630 A

SWITCHED POWER FACTOR AND *********HARMONIC CORRECTION EQUIPMENT MEDIUM VOLTAGE SECTION 16280E

NXPLUS C Single busbar. Maintenance-free for lifetime

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Transcription:

ECOVAR High Voltage Power Capacitors are manufactured at our Sinnar Plant in India which is an ISO 9001 accredited facility & houses a computer aided design manufacturing processing and testing infrastructure that ensures all products manufactured strictly comply with domestic and international standards and perform to the highest levels of safety reliability and life expectancy. Technology and Basic Construction : Amongst most electrical products Power Capacitors are highly susceptible to premature failures if improperly installed or if the application or load profiles are non linear or the system parameters are erratic. It is therefore of atmost importance that capacitors are designed to perform under such onerous conditions. Hence material selection quality inputs design manufacturing and processing parameters assume critical importance. ECOVAR High Voltage Power Capacitors are manufactured from raw material inputs sourced from the world s foremost manufacturers of plastic film dielectrics aluminum electrode foils and electrical insulating fluids. ECOVAR Capacitors generally utilize the following raw materials unless special end use applications necessitate use of alternative material : Dielectric : Electrical Grade Double Side Hazy Biaxially Oriented Polypropylene Film. Electrode : High Purity Soft Annealed Aluminum Foil. Impregnant : Phenly Xylyl Ethane (PXE) / Jarylec Non PCB Non Toxic Biodegradable. Housing : Stainless Steel / Mild Steel Sheet. Bushings : Soldered or Welded Brown / Gray Glazed Porcelain Insulators. Exterior finish : Etched Primer with Final Coats of Epoxy Paint. Visual comparison of Plain & Hazy PP Film Power Loss : ECOVAR Power Capacitors are uniquely designed to deliver optimun performance at very economic operating cost viz. power loss which are limited to maximum of 0.12 Watts / kvar on start up and 0.1 Watts / kvar after 500 hrs of operation. The extremely low watt losses contribute significantly in enhancing the capacitor life expectancy levels. Watt Loss & Capacitance Variation Graphs : Variation in losses (W/kvar) as a Variation in losses (W/kvar) as a Variation of capacitance C(μF) as

function of temperature function of operating time a function of temperature Fusing Techniques : Internal Fuse Design : ECOVAR Capacitor units are generally provided with internal fuses across each element for rendering internal protection to the capacitor unit in case of a fault occuring within the element winding. These fuses are designed on the basis of stored energy principle and coordinated to withstand all normal and some abnormal system overloads and disturbances and to render overall unit protection. (Refer to detailed internal fuse technical write up available on request). ECOVAR Capacitor units are also offered with option of conventional external fuses (Expulsion type / HRC type) depending on the unit kvar rating as also application and severity of protection required. Top Externally Fused Cell Internally Fused Cell Diagram Showing Internal Fusing Of Element In One Series Group : External Fuse Design :

An expulsion fusing system as used for protecting capacitors consists of three components which include the fuse tube / barrel the fuse link and the ejector spring. The proper operation of a fuse is dependent upon these components working in close harmony with each other. The illustrations below show the fuse assembly operation & visual indications of the fuse in fused and blown fuse position. Proper assembly of the fusing system is critical to the successful operation of the fusing system whereas incorrect installation may result in severe damage to the fuses the capacitors and / or capacitor bank. Expulsion fuse mounting arrangement Fuse link operation inside barrel Spring in Fused Position Spring in Blown Fuse (Indicating) Position Top Technical Comparison Between Internally & Externally Fused Capacitor Banks : Parameter Of Comparison External Fusing Internal Fusing Fuse isolates only the failed / faulty element No Yes

Capacitor unit is isolated on fuse operation Yes No Reduction in Bank output after fuse operation Considerable Negligible Reduction in unit life after fuse operation Unpredictable Marginal Bank with cells of higher kvar Out put No Yes Reliability of fuse co ordination / unbalance protection Un Predictable Case rupture protection Yes No Economy in cost of installation No Yes Vary Reliable Space requirement for installation Occupy More Space Occupy Less Space Visual indication of fuse operation Yes No Terminal to case insulation protection Yes No Consistency in fuse operation / protection No Yes Fuse is subject to routine electrical testing along with the unit Fuse is protected from environmental hazards No No Yes Yes Cost of structural steel & weight Higher Lower Convenience of assembly and connections Cumbersome Convenient External electrical clearances Are Less Are More Unit replacement in case of failure Convenient Cumbersome Types Of Mounting : Illustration showing Space saving & External Clearances

Capacitor banks can be offered with option of units mounted horizontally or vertically performance parameters remaining the same in either case. However for space saving compactness and better clearances in case of moderately sized or larger rated outdoor installations horizontal mounting is recommended. Internal or external fusing can be offered for both types of mounting options. Internally Fused Horizontally Mounted Units Externally Fused Vertically Mounted Units Pole Mounted Capacitors : Pole Mounted Capacitor Banks can be offered with power out puts from 300 kvar to 1200 kvar. These are operated with automatic vacuum / gas insulated switches and find applications on rural feeders where monitoring is difficult hence warrant a virtually maintenance free installation. These capacitors are usually offered with external fuses as bank and unit ratings are small. However dual fusing techniques are also offered as this helps not only in preventing case rupture due to dual protection but also ensure that the external fuses do not operate fictitiously as the internal fuses take care of most of the faults leaving the external fuse to operate only in case of a container to pack insulation failure / major external fault. Typical arrangement of externally fused pole mounted capacitor bank

General Arrangement Of ECOVAR Capacitor Unit : Bank Connections & Configurations : Capacitors Banks can be offered with option of the following configurations : 3 Ø Delta Connected. 3 Ø Y Connected. 3 Ø Y Y Connected. 1 Ø H Connected (Traction Duty Application for Railways). For Y / Y Y connected capacitor banks the star point is usually kept floating & used for sensing voltage & current unbalance. Accordingly suitable unbalance protection relays are provided on the control & relay panel to provide for tripping the bank on occurrence of severe unhealthy or unbalanced conditions. Below are connection diagrams that indicate various configurations & protection techniques. Also detailed herein are various protection schemes with switching & protective accessories. Delta Connected Capacitor Bank Y Connected Capacitor Bank With Voltage Unbalance Protection Y Y Connected Capacitor Bank With Current Unbalance Protection Capacitor Bank Control & Protection Schemes : Top

Universally practiced switching and protection schemes are designed and engineered to render total and thorough protection to the capacitor installation from internal abnormalities as also from external system disturbances or hazards. It is strongly recommended to provide over voltage under voltage over current earth fault ON time delay and unbalance protection to capacitor bank installations. Some typical protection schemes are shown in the schematic diagram below. Y Connected Capacitor Bank With Switching & Protection Equipment : Y Y Connected Capacitor Bank With Switching & Protection Equipment : Typical Layout Of An Outdoor Capacitor Installation :

Shown alongside is a typical layout of outdoor capacitor installation along with relevant switchgear and protection equipment. Reference standards : ECOVAR High Voltage Power Capacitors can be offered to comply with various international standards such as : IS : 13925 & IS : 12672 IEC : 60871 NEMA : CP 1 CEI : 33 7 VDE : 0560/4 BS : 1650 ANSI : IEEE Std 18 French : C 54102 CSA : C.22 2 No 190 AS : 2897 Range : Unit Voltage : 1.1 kv to 24 kv Unit Out put : 50 kvar to 600 kvar Bank Voltage : 3.3 kv to 145 kv Bank Out put : 300 kvar to 50 MVAr Basic Insulation Levels : The insulation levels for capacitor banks for various voltage networks are given in the table below : Basic Insulation Level of bank kv (SYSTEM) 12 24 36 72.5 123 145 Power Frequency withstand Voltage kv (RMS) 28 50 70 140 185 230 1.2/50 ms impulse withstand Voltage kv (PEAK) 75 125 170 325 450 500 Permissible Over Loads : Capacitor cells and banks may be required to perform under stressed and overloaded conditions for certain durations.

The permissible upper limits with respect to voltage and current overloading and the corresponding durations are : Current : 1.30 times rated current continuously. Voltage : 1.10 times VN for 12 hrs in a duration of 24 hrs. 1.15 times VN for 5 min. in a duration of 24 hrs. 1.30 times VN for 1 min. in a duration of 24 hrs.