Industrial Chargers and

Similar documents
AME. Rectifier - Battery charger. Industrial applications: Key features:

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A

Industrial PFC UPS System

POWER kva

Technical Data Sheets

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

POWER kva

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheets

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

AT30 SERIES BATTERY CHARGER

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Protect RCS BROCHURE JUNHO 2013

Technical data sheets

Technical Data Sheets

EFFEKTA Power Supplies

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Data Sheets

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Switchmode rectifier type. Type UP phase. »We store the world's energy« Network

AT EVO SERIES BATTERY CHARGER

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

EVO AT SERIES BATTERY CHARGER

Industrial Power Supplies

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

ATevo SERIES BATTERY CHARGER

Technical Data Sheets

Three Phase UPS Systems Range: 10 to 500kVA

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Illuminator Series CR NEMA 3R

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Specification SENTINEL PRO

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Availability secured. For Railway, trackside and infrastructure Systems

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

SECTION DC POWER SUPPLY/BATTERY CHARGER

POWERTRONIX QUASAR 5-40 KVA

AT SERIES EVO BATTERY CHARGER

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

DC POWER SUPPLY SYSTEMS

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

PRODUCT SPECIFICATION File: EA-400H2U-02 Date: Feb., 16, 2005

PowerValue 11/31 T kva

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Power Conversion Systems. SCHAEFER International. Switchmode Power Supplies, Chargers & Inverters. Thyristor-controlled Power Supplies & Chargers

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

MGE TM Galaxy TM 7000

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

PRODUCT SPECIFICATION File: EA-250U1C-10 Date: May, 25, 2005

Availability secured. For power generation transmission and distribution

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

QUEENSLAND URBAN UTILITIES

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

PRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Power Supply EL

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Keatec Energy Catalogue 2018 Telecommunications

Automatic DC Power Supply/Battery Charger

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

MTPi2000C - 80 KW (RANGE)

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

PRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Switching Power Supplies

Master DIALOG INDUSTRY RANGE

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

UPS Multi Sentry 10-20kVA

Features. Description. Table of Contents

Availability secured. For power generation transmission and distribution

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

MGE TM Galaxy TM 7000 GFC

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Supply EL

Technical data sheets

INTELEPOWER CX COMMUNICATIONS SYSTEMS

EMERGENCY VEHICLE BATTERY MANAGER PS2024

R series solar charger inverter 1000W to 6000W

Chloride Apodys rectifier-charger 3Ph

Transcription:

Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines Energy and Power Generation, Transmission, Distribution Transportation Rail, Airports, Shipping Water Desalination, Treatment Instrumentation & Process Control Chemicals, Mining, Steel, Paper Robust, Reliable and Flexible These are robust, industrial rectifiers using microprocessor controlled thyristor technology to provide high-reliability power supply and battery charging capabilities. >> www.powersupplysystems.com

>> Industrial Chargers and DC Systems Key features Communications system used to monitor and control the defined parameters locally or remotely. Choice of several types of batteries: - nickel-cadmium - vented or gas recombination - lead acid - vented or gas recombination Battery testing Parallel operation Simplified maintenance Customised exact solutions using an extensive range of options High MTBF and low MTTR Bespoke documentation; drawings, manuals Total solutions including switchgear, load distribution. International Service support comprehensive packages including; - Product Services: Installation, Commissioning, Service Contracts - Site Services: Load testing, monitoring Specification INDUSTRIAL CHARGERS AND DC SYSTEMS INPUT SPR Single phase 230Vac ± 10% TPR Three phase 400Vac ± 10% Other voltages available as non-standard option Exceptional variations + 15 / - 20% (functional) Frequency 50Hz or 60Hz ± 6% OUTPUT Nominal voltage (Udc) 24V 48V 110V 220V (on request 12, 32, 60, 125 and 250V) Range of operating voltage Floating charge 75% to 125% of Udc Nominal High rate charge 75% to 135% of Udc Nominal Commissioning charge 75% to 135% of Udc Nominal Static voltage regulation ± 1% in the following conditions: at float charge 0-100% DC load variation input voltage ± 10% input frequency ± 6% temperature from 0 C to 40 C Dynamic voltage regulation Using standard filter and the battery connected (capacity higher than 5 times I nom) Load step Deviation Recovery time 10%-100% -5% 250ms 100%-10% +5% 70ms

Current regulation ± 1% to I max Long-term stability of UDC 0.15% for 1000 hours Temperature coefficient of UDC 0.02% per C Charging characteristic Constant current/ constant voltage (I/U as per IEC 478-1) during float charge Input/Output isolation 2000 VAC between input/output and electrical earth Insulation resistance > 10 MΩ, 500 VDC Ripple Max 1% rms of nom. DC voltage, with a battery Ah capacity of 5 times the charger nom rating, battery connected (see our filter options). 2.5% rms typical (max 5%) on rectifier output, battery not connected. PROTECTION Polarity reversal of battery => blows battery fuse (optional) AC and DC surge limitation Soft-start function 0 to 100% Short-circuits Limited to 100% of rated current Internal DC fuse Non-volatile storage of system parameters and user setting Mains failure shutdown Rectifier failure shutdown High-voltage DC shutdown Thermal protection EMC emissions Generic emission standards EN 50081-2 and generic immunity standards EN 50082-2 available as standard option. Safety According to EN 50178 standards ENVIRONMENTAL Ambient temperature Operating : 0 C to + 40 C Derate from 40 C to 55 C by lowering the output current by 1.25% per C Storage: -25 C to +70 C Relative humidity Operation: from 20% to 95% non condensing. Storage: from 15% to 90% (in original packaging). Acoustic noise Typical 45-65 db(a) Altitude Up to 1000m, derate from 1000 to 4000m by lowering the output current by 7% per 1000 m.

Ratings SPR - Single Phase Rectifier SPR - Output Output Voltage Vdc Output Current A 24V 5 10 15 25 35 50 75 100 48V 5 10 15 25 35 50 75 100 110V 5 10 15 25 35 50 - - 220V 5 10 15 25 - - - - Information on other output voltages available on request. Type example: 24SPR10 = SPR 24V/10A TPR - Three Phase Rectifier TPR - Output Output Voltage VDC Output Current A 24V 25 50 75 100 125 150 200 250 >250 48V 25 50 75 100 125 150 200 250 >250 110V 25 50 75 100 125 150 200 250 >250 220V 25 50 75 100 125 150 200 250 >250 Information on other output voltages and output current over 250A available on request. Type example: 24TPR50 = TPR 24V/50A CABINETS Wall mounted and floor standing cabinets available depending on system rating and options specified. Weights and dimensions on request. Also available: Dual system in single cabinet Battery integrated in system cabinet Matching battery cabinets >> Industrial Chargers and DC Systems FEATURES Rectifier output current Load DC voltage Metering AC mains voltage (Average Voltage) Rectifier output voltage Controls Rectifier failure trip High DC voltage trip Mains failure trip

Alarms High charge voltage battery Low charge voltage battery Rectifier failure High rectifier current High DC load voltage Low DC load voltage AC voltage high and low (mains failure) Earth fault + / earth fault - Over temperature trip (only in case of forced-air cooling) Alarm reset Adjustment of alarm levels Available customisation features for the high rate charge Manual Automatic: 0 to 99h Periodic: 1 month, 6 months or 12 months Commissioning charge Current limitation for commissioning charge Available customisation features for the alarms Latch (display alarm and/or relay outputs) Adjustable alarm time delays Monitoring High rate charge time remaining List of current alarms History of up to 200 events OPTIONS To provide exact solutions for each application, Saft power systems offers a wide range of options: Remote alarm Battery temperature compensation Manual adjustment of voltage and/or current (limited to non-battery systems) Interior light High DC voltage trip End of discharge contactor Input MCB / fuse / switch or contactor Battery MCB fuse / switch Load MCB / fuse / switch Analog meters in front panel Blocking diode for parallel redundancy Cabinet heater Fuse / MCB trip alarm High ripple voltage alarm 24V and 48V telecom filter Diode dropper Audible alarm Low electrolyte level Protection: - External cabinet: up to IP65 - External wall-mounted cabinet: IP41 - Open-door cabinet: IP20 Interior single-phase 16 A max AC outlet LED indicators in front panel Remote voltage sensing (battery) Battery room fan control during high rate charge Four multifunction digital inputs are available, for example: - Low electrolyte level - High ripple voltage - Battery symmetry fault - Diode dropper fault - Fuse/ circuit breaker trip - Free programmable text Five inputs for specific controls Over temperature trip (Only in case of forced ventilation) Monitoring: - Stored and time-stamped history of events Communication galvanically isolated RS232C Remote surveillance and control software (sparc) Battery/ load current measurement Special treatment (Tropicalization, relative humidity up to 95%, etc) Low smoke wiring (halogen-free) Special markings Customised cabinets (paints, etc.) Mains change-over switch Special types of fuses Door mounted on/off switch 12 Pulse control Protocol convertor (Byte-bus, J-bus) Battery fuse box Other options on request EMC filtering >>

BATTERIES Saft power systems has considerable in-house knowledge in battery technology and is able to offer expert advice on the specifying, selection, operation and testing of batteries. Our total system solutions include a wide range of products using lead acid and nickel-cadmium batteries in vented and gas recombination technologies. Replacement batteries can be supplied and installed by our global service team. SERVICE Saft power systems Global Services offer the following services to support all Industrial Power Supply Products: Product Services Installation & Commissioning Preventative Maintenance Spare Part Kits Refurbishments Service Contracts 24/7 Global Service Cover Training SAFT POWER SYSTEMS For more information please refer to our website: http : // www.powersupplysystems.com Site Services Battery Replacement Load Bank & Site Capacity Tests Power Quality Services Standby generators and other essential equipment hire and supply E-service/remote Monitoring Battery Monitoring Facility & Equipment Management Design & Build - Turnkey Solutions Power Systems Whenever wherever wattever Industry - IT - Telecoms - Transportations- Services Realisation: MultiCopy Purmerend SPR/TPR-SPS 01.06-E. Information subject to change without notice. Copyright