Electronic Ignition Module

Similar documents
Electronic Ignition Equipment

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners

For air dampers and control valves of oil or gas burners

Connection Accessories for small Burner Controls

Actuators for air dampers and control valves of oil burners

For air / gas dampers and control valves of oil or gas burners

SQN9... Damper Actuators. Building Technologies HVAC Products. SQN9..., front (covers removed) SQN9..., rear (covers fitted)

Actuators for Air and Gas Dampers

ASZ... Potentiometers. Building Technologies Division. ASZxx.3x

Actuators for Air and Gas Dampers

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

Actuators. Building Technologies Division

Actuators for air and gas dampers

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Actuators for Air and Gas Dampers

SKPx5... Actuators for Gas Valves. Building Technologies HVAC Products SKP15... SKP25... / SKL25 SKP55... SKP75...

Model Number Structure

Differential Pressure Sensors

Gas Pressure Governors

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Proportional controlling element

Actuators for Fire Protection Dampers

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

MF /MS Series

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Boiler Management Unit (BMU)

VLF45... Hot Air Valves. Building Technologies Division

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

2-position electric actuators with Ball valves VBZ ½...11/4

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

SAV Electronic Valve Actuator

User manual. Active neutralizing electrode JO96/1/L

Temperature Controller (Heat Pumps)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Electromotoric Actuators

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Differential Pressure Sensors

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Electromotoric Actuators

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

SAX Electronic Valve Actuator

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Differential Pressure Switch QBM81-

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

Technical Documentation

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

AXIAL FANS Axis / Tubo OPERATION MANUAL

Differential Pressure Switch QBM81-

Emergency lighting units EM powerled

Electrical Actuators

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Actuators for Fire and Smoke Protection Dampers

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Air damper actuators

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

IMMOBILISER SYSTEM INTRODUCTION

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Level Measurement Point level measurement - RF Capacitance switches

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Lexium integrated drives

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

i3000s/i2000 Flex AC Current Probe

Technical data. Safety notes

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Pressure Sensors. for liquid and gaseous media

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Lexium integrated drives

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Electromotoric actuators

2-Year Limited Warranty. See the Users Manual for the full warranty.

Solenoid coil for control in potentially explosive areas Type BZ

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Operating instructions Binary level sensor LMT /00 06/2011

Portable pressure calibrator, Wally Box III Model CPH7600

Emergency lighting units EM powerled

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Surface mounting, flush mounting, and DIN track mounting

VEM motors Thurm GmbH

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Differential pressure sensor

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Overview of types. Technical data. Safety notes

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Transcription:

7 607 Electronic Ignition Module TQO31A27 Electronic ignition module for use with oil or gas burners operating with singleor double-pole ignition. The TQO31A27 and this Data Sheet are intended for use by OEMs which integrate the ignition module in their products. Design The TQO31A27 is an electronic ignition module of compact design with high sparking power. Ignition spark generation is optimized to meet the specific requirements of forced draft oil and gas burners. Integrated suppression elements ensure low interference voltages below the standard limits. A wide voltage range assures reliable highvoltage generation even in the case of unfavorable operating conditions. The housing is made of impact-proof and heat-resistant plastic. The fixing holes and compact design enable the ignition module to be accommodated under the burner control s plug-in base. The TQO31A27 is embedded in synthetic resin. The primary and secondary terminals are of plug-in design. The electronic ignition module is designed for use with the following types of burner controls: LGA..., LGB..., LGD1..., LMG..., LOA..., and LMO... The high-voltage ignition cable is supplied by the burner manufacturer. 03.07.2003 HVAC Products

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! The ignition module generates high-voltage which, if improperly applied, can lead to insulation failure that can cause fire and damage to persons! Do not open, interfere with or modify the module! Before performing any wiring changes in the connection area of the TQO31A27 especially on the high-voltage side completely isolate the module from the mains supply (all-polar disconnection) Ensure protection against electric shock hazard by providing adequate protection for the connection terminals Check to ensure that wiring is in an orderly state Fall or shock can adversely affect the safety functions. Such units may not be put into operation even if they do not exhibit any damage Mounting notes Ensure that the relevant national safety regulation are complied with Mounting work must be carried out by qualified staff Protection against electric shock hazard must be ensured through the way the module is mounted. The parts carrying high-voltage should be protected against dirt and humidity to ensure sufficient sparking power. Insulate the ignition module adequately against non-earthed external, exposed parts Locate the ignition electrode and ionization probe such that the ignition spark cannot arc over to the ionization probe (risk of electric overloads on the connected burner control) Installation notes Installation work must be carried out by qualified staff The connection of the earthing lug to burner ground must be firm and electrically conducting Electrical connection of the high-voltage ignition cables Run the high-voltage ignition cables - always separately while observing the greatest possible distance to the unit and to other cables - as short as possible, avoiding loops and sharp bends Always use suitable high-voltage ignition cable For example: Silicon or TPE cables having - an outside diameter of min. 5 mm - a dielectric strength of at least 40 kv Not suited are PVC, PTFE, or EVA (Radox) cables. 2/5

Commissioning notes Commissioning and maintenance work must be carried out by qualified staff Prior to commissioning the plant, check to ensure that wiring is in an orderly state High-frequency equipment places special requirements on high-voltage ignition cables and electrodes. Always use special high-voltage ignition cables and electrodes that are suited for this type of ignition equipment An important prerequisite for ensuring operating safety is the correct sizing and adjustment of the spark gap. Adjust it such that safe ignition is ensured under all permissible operating conditions The location of the ignition module, the high-voltage ignition cables and the spark gap on the burner have a considerable impact on the generation of electromagnetic disturbances. The notes relating to the laying of high-voltage ignition cables and adequate earthing of both the module and burner should be observed In the case of frequent burner startup repetitions and short on times, ensure that the ignition module s permissible on time will not be exceeded Norms and certificates Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Low-voltage directive 89 / 336 EEC 73 / 23 EEC ISO 9001: 2000 Cert. 00739 ISO 14001: 1996 Cert. 38233 Service notes Disposal Maintenance work must be carried out by qualified staff Each time a unit has been replaced, check to ensure that wiring is in an orderly state and make the safety check as described in «Commissioning notes» The ignition module contains electric and electronic components and may not be disposed of together with household waste. Local and currently valid legislation must be observed. Ordering Electronic ignition module (Without accessories) When ordering, please give the complete type reference. TQO31A27 Accessories Mains cable, 25 cm long, with ferrules Mains cable, 50 cm long, with ferrules Mains cable, 120 cm long, with ferrules Insulating plug for single-pole operation AGV31.001 AGV31.002 AGV31.003 AGB2.001 3/5

Technical data General unit data Rated data, primary side Operating voltage AC 230 V Voltage range AC 220 V 15 %...AC 230 V +10 % Mains frequency 50...60 Hz ±5 % Primary current 0.25 A Power rating 60 VA Power factor cos ϕ > 0.6 Discharge current to ground, < 1.2 ma to DIN EN 50165 Leakage current against ground </- 5 ma to DIN EN 50 165 Terminals on the primary side double-pole, quick connectors 2.8 x 0.8 mm Safety class I Rated data, secondary side, at AC 230 V / 50 Hz High-voltage output 2 x 7.5 kv ampl. or 1 x 15 kv ampl. Ignition current 40 ma (rms) Ignition frequency 16 khz ±4 khz Spark energy (double-pole operation) 500 mj On time 33 % in 3 min at 35 C 20 % in 3 min at 60 C No-load operation max. 30 s High-voltage terminal round connector, 4 mm Spacing of electrodes 2.5...5 mm Interference suppression / immunity Network disturbances to DIN EN 61000-3-2 / DIN EN 61000-3-3 Immunity to DIN EN 50165 / EN 61000-4-6 / EN 61000-4-3, degree of severity 3 Limit values Operating voltage On time at AC 265 V and 60 C Miscellaneous Degree of protection Earthing Weight Tightening torque for fixing screws min. AC 187 V (reduced sparking power) max. AC 265 V 14 % in 3 min IP 40 (with connectors plugged in) with earthing lug, 4.2 mm dia. approx. 265 g 1.2...1.5 Nm (locking paint recommended) Environmental conditions Transport DIN EN 60 721-3-2 Climatic conditions class 2K2 Mechanical conditions class 2M2 Temperature range -25...+60 C Humidity < 95 % r.h. Operation DIN EN 60 721-3-3 Climatic conditions class 3K5 Mechanical conditions class 3M3 Temperature range -10...+60 C Humidity < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted! 4/5

Dimensions Dimensions in mm 4 12 7607m02e/0703 36 8 2 x 7 4,3 2 x 4,7 9 76 70 11,1 57 85 3,1 23 8 4 39 11 5 2 x 8 2 x 5 63 4,2 2 Earthing lug 2003 Subject to change! 5/5