McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

Similar documents
Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay Climate Control Singer

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay Air-Cooled Reciprocating Chiller ALR

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay Central Station Air Handler Medium Pressure MSL

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

Hoshizaki America, Inc.

Eclipse 2000 Service Parts

Product Manual C: Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to Watts)

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

GUIDE SPECIFICATIONS. ES Series R-410A

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

REPLACEMENT PARTS MANUAL

PARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

REPLACEMENT PARTS MANUAL

Product Data. 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

NM650 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

REPLACEMENT PARTS MANUAL

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

FM800R SERVICE PARTS

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Low Profile Unit Cooler

Transcription:

Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History...3 Nomenclatures Serial Number...4 Model Number...4 Field Installed Accessories Thermostats and Subbases for Electromechanical Control Units...5 Thermostats and Subbases for Mark IV Control Units...5 Thermostat Accessories...6 Hoses & Valves...6 Filters and Filter Components...6 Unit Accessories...7 Refrigeration Circuit Diagram...8 Components...9, 10 Fan and Housing Assembly... 11 Control Box Standard Control Layout- 60 HZ...12 Standard Control Layout- 50 HZ...13 Components...14, 15 Critical Parts List...CPL1 WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 2

Parts List Revision History Rev. Date A 02/99 Page 3 - Added Revision History page. Page 16 - Corrected part number for Control Box (Bub. Num. 29). B 01/13 Reformat to current standards. Change p/ns to 9 Digits. Page 4- Added Serial Number February, 1999 and Later. Page 18- Delete sheet metal note & replace with- Sheet metal is obsolete. Field fabricate. CPL1- Add Critical Parts List. C 08/17 Pages 11-12 Combine on one page & delete one page. Pages 17-18 Delete pages- Sheet metal. CPL1- Change motor p/n 060704503 to V from 460/60/3V. Delete Refrigeration Circuit. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 3

Nomenclature Serial Number 7 8 A 12345 00 Plant Identification Number 7 = Auburn Year Manufactured S = 1987 T = 1988 U = 1989 V= 1990 W= 1991 X= 1992 Y= 1993 Z= 1994 5= 1995 Engineering Revision Serial Number Month Manufactured A=January G= July B=February I=August C=March J=September D= April K=October E= May L=November F= June M=December CCH 015A E G S Digits 1-3 Model Type CCH= Ceiling Concealed Water Source Heat Pump CCG= Ceiling Concealed Cooling Only CCW= Ceiling Concealed Extended Range Heat Pump Digits 4-7 Unit Size / Vintage 007A = 7,000 Nominal Cooling Btuh 009A = 9,000 Nominal Cooling Btuh 012A = 12,000 Nominal Cooling Btuh 015A = 14,000 Nominal Cooling Btuh 019A = 19,000 Nominal Cooling Btuh 024A = 24,500 Nominal Cooling Btuh 030A = 30,000 Nominal Cooling Btuh 036A = 35,000 Nominal Cooling Btuh 042A = 41,000 Nominal Cooling Btuh 048A = 48,000 Nominal Cooling Btuh 060A = 61,000 Nominal Cooling Btuh Model Number Digit 10 Return Air Arrangement S = Straight Discharge E = End Discharge Digit 9 Voltage A = 115/60/1 G = 208- N = F = 208-230/60/3 T = 460/60/3 W = 575/60/3 J = Q = 380/50/3 Digit 8 Control System E= Electromechanical Control M= Mark IV Control C= MicroTech Control WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 4

Field Installed Accessories Thermostats & Subbases for Electromechanical Control Units STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Thermostat Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off- Auto" switch and fan "On-Auto" switch. Subbase DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Requires factory installed night setback relay or field installed night setback or night setback/demand control relay. Night setback bulb set 8 o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Requires minimum of 6 wires. Thermostat Subbase PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-2000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Part Number 803005245 (Includes subbase) 060687201 060687401 060687301 060687401 060602301 (Includes subbase) Thermostats & Subbases for Mark IV Control Units STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off- Auto" switch and fan "On-Auto" switch. Subbase STANDARD MANUAL & AUTO CHANGEOVER THERMOSTAT & SUB- Thermostat BASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Subbase DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK AND OVERRIDE. Honeywell T874/Q674. LED Thermostat for "Service." Mounts horizontal. Requires grounding of unit "U" terminal. Night setback bulb set 8 o F below day heat setpoint. Night setup bulb set Subbase 6 o F above day cool setpoint. System "Off-Auto" switch and fan "On-Auto- Override" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE FOR OPERATING TWO UNITS. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch. 803005245 (Includes subbase) Thermostat 060685301 Thermostat Subbase PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-2000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Part Number 060684801 060685301 060684901 060685501 060684801 060685201 060684701 060602301 (Includes subbase) WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 5

Field Installed Accessories Thermostat Accessories NIGHT SETBACK THERMOSTAT. Honeywell T822. Mounts vertically. No LED. No switches. For applications requiring a separate NSB stat. UNIVERSAL THERMOSTAT GUARD. Honeywell TG500A. Clear plastic w/ring base, lock and keys. DELUXE LOCKING COVER FOR T874/Q674 THERMOSTATS. Honeywell TG504A. Applies only to T874/Q674 thermostats. Replaces standard thermostat cover. Includes cover, lock and keys. ADAPTER PLATE FOR T874/Q674 THERMOSTATS. Allows for horizontal thermostat to be mounted on a vertical junction box 7-DAY TIME CLOCK. OVERRIDE TIMER - 1 HOUR. OVERRIDE TIMER - 6 HOUR. Part Number 803005180 802005426 060684501 802007673 802005716 802005717 802005718 Hoses & Valves Part Number STANDARD SUPPLY OR RETURN HOSE. Rubber hose with MPT 2' long, 1/2" I.D. 802025396 swivel hydraulic fittings on each end. Order two per unit. 3' long, 1/2" I.D. 802025397 FIRE RATED SUPPLY OR RETURN HOSE. Stainless steel, braided 2' long, 1/2" I.D. 802025593 hose with one MPT and one MPT swivel fitting. Order 2 per unit. 3' long. 1/2" I.D. 802025594 CONDENSATE HOSE ASSEMBLY. Requires trap by others. Order Clear plastic, 38" long 060687701 one per unit. Fire rated, 24" long 060688801 Includes fitting to be soldered on unit. Fire rated, 36" long 060688802 BALL VALVE. Combination shutoff and balancing valve with memory 1/2" FPT 802026097 stop. Order two per unit. Filters & Filter Components Part Number 2" THICK THROWAWAY FILTER. Fits into 2" thick filter rack. Must order in multiples of 12. 060687102 1" THICK THROWAWAY FILTER. Replacement for standard filter. Must order in multiples of 12. 060604802 1" THICK CLEANABLE FILTER. Must order in multiples of 12. 060687003 2" THICK PLEATED FILTER, 35% EFFICIENT. Must order in multiples of 12. 060759802 RETURN AIR DUCT COLLAR & TWO INCH FILTER RACK. 060672221 WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 6

Field Installed Accessories Unit Accessories SHUTDOWN RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. For shutdown of the unit from an external 24 volt AC power source. Relay mounts at control box. NIGHT SETBACK RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. Relay to put unit into NSB mode from an external 24 volt AC power source. Relay mounts at control box. Operation requires ACO stat with built-in NSB or a separate NSB stat. NIGHT SETBACK/DEMAND CONTROL RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source (3 total wires required). Relay mounts at control box, operation requires ACO stat with built-in NSB or separate NSB stat. RANDOM START RELAY FOR ELECTROMECHANICAL CONTROL 115, 208/230, 265V UNITS. Time delay relay to delay compressor startup when coming off night operation and to not allow all units to start at the same time. 460, 575V CONDENSATE OVERFLOW SAFETY SWITCH FOR ELECTROMECHANICAL CONTROL UNITS. Float switch in drain pan to shut down compressor operation when pan fills. AUXILIARY RELAY. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operate. BOILERLESS SYSTEM KIT. Must be Mark IV control unit. Includes electronics and sensor to lock out compressor operation at 50 o F to 60 o F EWT and provide SPNO contacts to a field supplied electric heater control system. LOGIC LINK II. Must be Mark IV control unit. Includes electronics, ACO stat and subbase for adjustable night setback and setup and compressor only shutdown (demand control/load shed) from a 24 volt AC external power source. Also includes 1 hour override control at the thermostat. LOGIC LINK II WITH BOILERLESS SYSTEM. Incorporates both Logic Link and Boilerless System control in one package. Includes ACO stat and subbase, and EWT sensor. Requires 24 volt AC external power source. MULTIPLE UNIT CONTROL PANEL. Allows master unit to be controlled by any thermostat. Slave units "follow" with paralleled operation. Master & 1 Slave Master & 3 Slaves Kit Not recommended with Boilerless System. Circuit Board only MOTORIZED VALVE. Includes prewired valve/operator, 3 foot conduit assembly with leads and quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum operating pressure. Requires control relay. See below. CONTROL RELAY FOR MOTORIZED VALVE. 1/2" FPT Relay only (3 req'd.per unit) Part Number 802005291 802005728 802007881 802005496 802005498 803005260 803005073 060844701 060845001 060846001 803005159 859002819 802005857 802005872 Kit with bleed port Valve 859004351 only with bleed port 802026205 Kit without bleed port Valve only w/o bleed port 060977401 060977001 Kit 859004354 Relay only 803005073 WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 7

Refrigeration Circuit Diagram TO WATER REGULATING VALVE (OPTION) 2 6 7 5 4 8 3 10 11 12 1 WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 8

Refrigeration Circuit Components 015 019 Bub. Num. Part Number 1 Compressor 13200 BTUH 060626701 1 1 1 Compressor 13200 BTUH 060626702 1 1 Compressor 1,2 17150 BTUH 060603002 1 1 Compressor 1,2 Bristol 060603001 A A 1 Compressor 3 Bristol 060806401 A A 1 Compressor 1,2 Bristol 060603002 B 1 Compressor 3 Bristol 060806402 B 1 Compressor Bristol 060603703 C 1 Compressor 1,2 Tecumseh 060618301 A A 1 Compressor 1,2 Tecumseh 060618302 B N/S Plug, Threaded 1/2" Red 802028117 1 1 1 1 1 1 1 1 N/S Compressor Overload 060943901 1 1 N/S Compressor Overload 060943902 1 N/S Capacitor, Compressor 25 Mfd, 370V 002007847 1 1 1 1 1 N/S Capacitor, Compressor 25 Mfd, 440V 802007855 1 1 N/S Capacitor, Compressor 30 Mfd, 370V 802007848 1 N/S Bracket, Capacitor 060675201 1 1 1 1 1 1 N/S Bracket, Capacitor 060675202 1 1 2 Coaxial Coil, (Wate To Refrig.) 1,2 Copper 2 Coaxial Coil, (Wate To Refrig.) 1,2 Copper 060601701 1 1 1 1 2 Coaxial Coil, (Wate To Refrig.) 3 Cupronickel 060601702 1 1 1 1 2 Coaxial Coil, (Wate To Refrig.) 1,2 Copper 060601801 1 1 1 1 2 Coaxial Coil, (Wate To Refrig.) 3 Cupronickel 060601802 1 1 1 1 3 Fin Tubular Coil (Air To Refrigerant) 060623801 1 1 1 1 3 Fin Tubular Coil (Air To Refrigerant) 060623501 1 1 1 1 N/S = Not shown on diagram Continued on next page. * Used with Bristol compressors. 1 = CCH 2 = CCG 3 = CCW a Standard Range Units: Bristol compressor used starting with Serial Number 7TA27218, Tecumseh used prior to this S/N. Extended Range Units: Bristol compressor always used. b Standard Range Units: Bristol compressor used starting with Serial Number 7TA29952, Tecumseh used prior to this S/N. Extended Range Units: Bristol compressor always used. c Standard and Extended Range Units: Bristol compressor always used. NOTE: Bristol compressor may be used to replace equivalent Tecumseh compressor (minor piping change and Bristol compressor mounting hardware required). WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 9

Refrigeration Circuit Components 015 019 Bub. Num. Part Number 4 Capillary 33 x.064 x.125 802001009 2 2 2 2 4 Capillary 22 x.064 x.125 802001158 2 2 2 2 5 Strainer 802001068 1 1 1 1 5 Strainer 060628801 1 1 1 1 6 Reversing Valve 802026045 1 1 1 1 1 1 1 1 7 Solenoid, Reversing Valve 24V 802026121 1 1 1 1 1 1 1 1 8 Switch, High Pressure 060605401 1 1 1 1 1 1 1 1 10 Thermostat, Low Temp Cutout 1,2,3 066540601 1 1 1 1 10 Thermostat, Low Temp Cutout 1,2 066540601 1 1 1 1 10 Thermostat, Low Temp Cutout 3 066540603 1 1 1 1 11 Speed Clip, Thermostat 802017214 1 1 1 1 1 1 1 1 12 Accumulator 3 060721701 1 1 1 1 12 Accumulator 3 060721801 1 1 1 1 N/S Flanged Nut, Compressor Mounting * 802012035 3 3 3 4 4 4 4 4 N/S Grommet, Compressor Mounting * 4 060623301 3 3 3 N/S Grommet, Compressor Mounting * 4 802003084 4 4 4 4 4 N/S Sleeve, Compressor * 4 060623401 3 3 3 N/S Sleeve, Compressor * 4 031313600 4 4 4 4 4 N/S Sleeve, Compressor * 5 044074900 3 3 3 4 4 4 4 4 N/S Spacer, Lower, Compressor Mounting * 5 060687901 3 3 3 4 4 4 4 4 N/S Spacer, Top, Compressor Mounting * 5 060687801 3 3 3 4 4 4 4 4 N/S Spring, Compressor Mounting * 5 060688001 3 3 3 4 4 4 4 4 N/S Flanged Nut, Compressor Mounting ** 802012035 4 4 4 4 N/S Sleeve, Compressor Grommet ** 4 031313600 4 4 4 4 N/S Grommet, Compressor Mounting ** 4 802003084 4 4 4 4 N/S Grommet, Compressor Mounting ** 5 802003436 4 4 4 4 N/S Retainer Washer, Compressor Mounting ** 5 802003437 4 4 4 4 N/S Spring, Compressor Mounting ** 5 802003438 4 4 4 4 N/S Washer, Compressor Mounting ** 5 802003439 4 4 4 4 N/S Drain Pan 060638002 1 1 1 1 1 1 1 1 N/S Water Regulating Valve 1,2,6 802026194 1 1 1 1 1 1 1 1 N/S Water Regulating Valve 1,2,6 802026200 1 1 1 1 1 1 1 1 N/S = Not shown on diagram * Used with Bristol compressors. ** Used with Tecumseh compressors. 1 = CCH 2 = CCG 3 = CCW 4 = Standard Construction units only. 5 = Extra Quiet Construction Units only. (Optional). 6 = Only on units with Water Regulating Valve Option. WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 10

Fan and Housing Assembly 18 16 17 22 20 20 STRAIGHT DISCHARGE IS STANDARD 15 21 END DISCHARGE SAME AS STANDARD EXCEPT ROTATED 180 015 019 Bub. Num. Part Number 15 Motor, 1/8 HP 060704501 1 1 1 1 15 Motor, 1/8 HP 060704502 1 1 15 Motor, 1/8 HP 060704503 1 1 N/S Motor Mount Kit 062200601 1 1 1 1 1 1 1 1 16 Capacitor 3 MFD, 370V 802007005 1 1 1 1 1 1 1 1 17 Bracket, Capacitor 850010570 1 1 1 1 1 1 1 1 18 Blower Housing, Weldment 060699603 1 1 1 1 1 1 1 1 19 Inlet Ring 060828601 1 1 1 1 1 1 1 1 20 Wheel, Blower 060704801 1 1 1 1 1 1 1 1 21 Support Bracket 060613201 1 1 1 1 1 1 1 1 22 Protector, Terminal 802007316 1 1 1 1 1 1 1 1 N/S = Not shown on diagram. WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 11

Control Box Standard Control Layout- 60 HZ 34 32 29 43 33 35 30 38 37 36 27 28 26 FRONT VIEW SIDE VIEW WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 12

Control Box Standard Control Layout- 50 HZ 34 42 32 29 41 33 39 40 35 30 43 27 38 28 37 36 26 FRONT VIEW SIDE VIEW WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 13

Control Box Components 015 019 Bub. Num. Part Number 26 Control Board, Mark IV 3 060638806 1 1 1 1 1 1 1 1 26 Control Board, Electromechanical 1 60679202K 1 1 1 1 1 1 1 1 N/S Control Board, Microtech 2 060959401 1 1 1 1 1 1 N/S Sensor Assy. Water Temperature 1 4EZS9158 2 2 2 2 2 2 N/S Clamp 802017214 2 2 2 2 2 2 2 2 27 Stand-Off 3 802028130 7 7 7 7 7 7 7 7 27 Stand-Off 1 802028130 4 4 4 4 4 4 4 4 N/S Stand-Off 2 802028130 1 1 1 1 1 1 28 Nylon Nut 3 802012415 7 7 7 7 7 7 7 7 28 Nylon Nut 1 802012415 4 4 4 4 4 4 4 4 N/S Nylon Nut 2 802012415 1 1 1 1 1 1 29 Control Box 061225702 1 1 1 1 1 1 1 1 30 Low Volt Guard 060609401 1 1 1 1 1 1 1 1 32 Contactor, Compressor 1,3 803005193 1 1 1 1 32 Contactor, Compressor 1,3 802005655 1 32 Contactor, Compressor 1,3 803005105 1 1 32 Contactor, Compressor 1,3 803005196 1 N/S Contactor, Compressor 2 047356506 1 1 1 N/S Contactor, Compressor 2 803005223 1 1 1 33 Relay, Fan 1,3 803005132 1 1 N/S Relay, Fan 2 047356506 1 1 1 1 1 1 34 Cup Washer, Ground Screw 802007455 1 1 1 1 1 1 35 Relay, Random Start 1,4 802005496 1 1 1 1 1 1 1 1 36 Relay, Shutdown 1,5 061019403 1 1 1 1 1 1 1 1 N/S = Not shown on diagram 1 Electromechanical Control units only. (Units with Model No. Digit 8 = E). 2 MicroTech Control units only. 3 Mark IV Control units only. (Units with Model No. Digit 8 = M). 4 Only on units with Random Start Relay Option. 5 Only on units with Shutdown Relay Option. Continued on next page. WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 14

Control Box Components 015 019 Bub. Num. Part Number 37 Relay Night Setback 1,4 802005728 1 1 1 1 1 1 1 1 37 Relay, Demand Control, BD Galt 1,5 802007881 1 1 1 1 1 1 1 1 38 Relay, Auxilliary 6 803005073 1 1 1 1 1 1 1 1 39 Angle Bracket 060760401 1 1 N/S Relay, Timed Output 2 802005206 1 1 1 1 1 1 N/S Relay, Boilerless System 2 802005206 1 1 1 1 1 1 N/S Relay, Fresh Air Damper 2 802005206 1 1 1 1 1 1 N/S Relay, Motorized Valve 2 802005206 1 1 1 1 1 1 N/S Terminal Block 2 3-Pole 049759001 2 2 2 2 2 2 N/S Terminal Block 2 4-Pole 049759002 1 1 1 1 1 1 N/S Terminal Block 2 5-Pole 049759003 1 1 1 1 1 1 N/S End, Terminal Block 802007431 1 1 N/S Terminal Board 2 802007090 1 1 1 42 Terminal Lug 802007744 1 1 43 Transformer 1,2,3 208/240V-24V 060614101 1 1 1 1 1 1 43 Transformer 1,2,3 265V-24V 060630701 1 1 N/S Transformer 2 24V 060949301 1 1 1 1 1 1 N/S Circuit Breaker 803007113 1 1 1 1 1 1 1 1 N/S Condensate Overflow Switch 1 803005260 1 1 1 1 1 1 1 1 N/S Condensate Overflow Wire 2,3 056794401 1 1 1 1 1 1 1 1 N/S = Not shown on diagram 1 Electromechanical Control units only. (Units with Model No. Digit 8 = E). 2 MicroTech Control units only. 3 Mark IV Control units only. (Units with Model No. Digit 8 = M). 4 Only on units with Night Setback Option. 5 Only on units with Demand Control Relay Option. 6 Only on units with Auxiliary Relay Option. WSHP; CCH,CCG,CCW 015-019 Vintage A Rev. C 08/17 RPL 0552357 / Page 15

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay WSHP, Ceiling Concealed CCH, CCG, CCW 015, 019 Vintage A Critical Components Unit Sizes Voltage Part Number Controls Control Board, MicroTech ALL ALL 060959401 Control Board, Mark IV ALL ALL 060638806 Control Board, Electromechanical ALL ALL 060679202 Compressor Compressor 015 208-060626701 Compressor 015 060626702 Compressor 015 060603002 Compressor, Bristol (CCH, CCG) 019 208-060603001 Compressor, Bristol (CCW) 019 208-060806401 Compressor, Bristol (CCH, CCG) 019 060603002 Compressor, Bristol (CCW) 019 060806402 Compressor, Bristol 019 060603703 Compressor, Tecumseh 019 208-060618301 Compressor, Tecumseh 019 060618302 Fan Motor Motor, 1/8HP ALL 208-060704501 Motor, 1/8HP ALL 060704502 Motor, 1/8HP ALL 060704503 Fan Housing & Wheel Assembly Blower Housing ALL N/A 060699603 Wheel, Blower ALL N/A 060704801 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 552357 Rev. C 08/2017 CPL Page 1 of 1