FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

Similar documents
AWZ 110. AWZ 13,8V/1A/7Ah/LM

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

AWZ 200. AWZ 13,8V/2A/7Ah/L

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

BNC BNC 12V/8x1A. Switch mode power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

HPSB 2512B v.1.0 HPSB 13,8V/2A/7Ah Buffer, switch mode power supply unit.

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

PSU-S-12V/L-3A/9/FTA/PTC-TR-MC AWZ v.1.0

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Elmdene International Ltd

Power supply for fire detection and fire alarm systems, smoke and heat control systems, and other fire protection systems, series ZSP135-DR

PSU EN54-4 Power Supplies

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

CX-SERIES ADVANCED BATTERY CHARGER

AC/DC Converter MBP250-2A13D13M

Industrial Power Supplies

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

R series solar charger inverter 1000W to 6000W

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

SecuriFire. Power Supply Unit B6-PSU. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Uninterruptible power supply Supply MEg101.4

D R C- 4 0 s e r i e s

Harness the Power of the Sun

AccuPower AQU126B Installation Instructions

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

GENERALITIES TECHNICAL FEATURES

Uninterruptible Power Supplies

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

CBI All in One DC UPS Power Solutions

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Pure Sine Wave Inverter Charger

PRODUCTS: POWER SUPPLY

AccuPower AQU128B Installation Instructions

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

CX Series User s Manual

IGLOO IGLOO EASY INSTRUCTION MANUAL

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Installing Power Components

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Features. Description. Table of Contents

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

LS200 Series Instruction Manual

SBC / 2140 / Stage Battery Charger User Manual

All In one uninterruptible power supply solutions

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

MILPOWER SOURCE M120BA-1A

USER GUIDE 12 V Lead acid batteries Ah

AL600ULX Series. Power Supply/Charger Installation Guide

DEEP SEA ELECTRONICS PLC

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

Autoranging Industrial Multimeter

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Industrial Chargers and

POWER SUPPLY aps-412_en 06/16

User Manual 1KVA-5KVA INVERTER / CHARGER

Application Engineering

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

Aurora Wind Interface Box

CZH-LABS Electronics-Salon

TECHNICAL DESCRIPTION

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

U n i n t e r r u p t i b l e P o w e r S y s t e m

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Fuse state indicator MEg72. User manual

DC (on) LED Signal. Multiple output connector for easy wiring

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Installation Instructions

Phoenix Inverter

CENTRAL BATTERY UNIT. Installation and maintenance instructions TKT3122

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

Application Engineering

AME. Rectifier - Battery charger. Industrial applications: Key features:

User Manual. Solar Charge Controller 3KW

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual

DEEP SEA ELECTRONICS PLC

RU BMS Power Supply and Battery Management System Owners Guide

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Emergency lighting units EM powerled

Three Phase UPS Systems Range: 10 to 500kVA

Transcription:

DSOS24V v.1.0 FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V EN* Edition: 2 from 30.08.2017 Supercedes edition: 1 from 24.05.2016

PSU features. Compliant with the requirements of the PN-EN 54-4 and PN-EN12101-10 standards and pt. 12.2 of the Regulation of the Minister of Interior and Administration of the Republic of Poland of 20.06.2007 Power supply for the call station of the DSO system, e.g. the PVA-15CST and two PVA-20CSE extensions by BOSCH 24V DC Uninterruptible Power Supply Single battery power supply (7Ah /12V) Wide supply voltage range (176-264V AC) Low ripple voltage Microprocessor-based automation system Measurement of the resistance of the battery circuit Automatic temperature compensation of the battery charging Battery test Two-phase battery charging The accelerated battery charging Battery electrical continuity control Battery voltage control Battery fuse status control Battery charge and maintenance control Deep discharge battery protection (UVP) Battery overload protection. Battery output protection against short-circuit and reverse polarity connection Output voltage control Acoustic indication of failure Technical inputs/outputs with galvanic isolation Technical outputs - relay type. ALARM technical output of collective failure EPS technical output of 230V AC power failure indication PSU technical output of power supply failure indication APS technical output of battery failure indication LED Optical indication. Protection types: SCP short-circuit protection OLP overload protection Convection cooling. Warranty - 3 year from the production date 2

TABLE OF CONTENTS: 1. Technical description. 1.1 General description. 1.2 Block diagram. 1.3 Description of components and power supply connectors. 1.4 Technical parameters 2. Installation. 2.1 Requirements 2.2 Installation procedure. 2.3 The procedure for checking the power supply 3. PSU operation indication. 3.1 Optical indication of operation. 3.2 Technical outputs. 4. Maintenance and operation. 4.1 Overload or short circuit of the power supply output (SCP activation) 4.2 Protection against reverse battery connection. 4.3 Deep discharge battery protection UVP. 4.4 Battery test 4.5 Measurement of the resistance of the battery circuit 4.6 Measurement of the battery temperature 4.7 Maintenance 1. Technical description. 1.1 General description. The DSOS24V is designed for uninterruptible power supply of call stations (firefighter's microphone) used in VAS (Voice Alarm Systems) requiring stabilized voltage of 24V DC (-5%/+5%). In the case of mains power loss, the PSU immediately switches to battery power. The power supply unit is housed in a metal enclosure (color red RAL 3001) with space for a 7Ah / 12V battery. The power supply unit uses maintenance free, AGM or gel batteries (7Ah/12V). 1.2. Block diagram. Fig. 1.Block diagram of the power supply unit. 3

1.3 Description of components and power supply connectors. Table 1. Components of the PCB of the power supply (see Fig. 2). Componen Description t No. F BAT fuse in the battery circuit, T2A / 250V BUZZER acoustic indicator PANEL Output terminal of the external optical indication TEMP battery temperature sensor jack LED lights - optical indication: AC AC voltage AUX 24V DC output voltage PSU PSU failure APS battery failure ALARM collective failure LB battery charging F AUX fuse in the battery circuit, 24V DC, F500mA / 250V jumper; switching on acoustic indication - indication ON - indication OFF Description: jumper on, jumper off Jumper for configuring the relay contacts: NC or NO. - contact closed in case of failure - contact open in case of failure (factory setting) Terminals of technical outputs EPS technical output of AC power failure indication PSU technical output of power supply failure indication APS technical output of battery failure indication ALARM technical output of collective failure indication The 1..8 Connector for connecting the CST BUS The RJ45 connector for connecting the call station (microphone) Fig. 2. The view of the printed circuit board of the power supply unit. 4

Table 2. Components of the power supply (see Fig. 3). Component Description No. Mounting shelf with dimensions of 540 x 190 [mm] for the call station PVA-15CST and two PVA-20CSE extensions by BOSCH LED lights - optical indication: AC AC voltage DC 24V DC output voltage FAILURE collective failure Battery space for a 7Ah/12V battery Battery connectors; positive: +BAT = red, negative: - BAT = black PE-N-L power connector 230V AC, F MAIN =T3,15A / 250V Fig.3. The view of the power supply unit. 5

1.4 Technical parameters: - Electrical parameters (Table 2) - Mechanical parameters Table 3) - Safety of Use (Table 4) - Operation parameters (Table 5) Table 2. Mechanical parameters. Power supply type: A (EPS - External Power Source) Supply voltage: 176 264V AC Current consumption 0,15A @230V AC Power supply frequency 50Hz PSU power 10W Rated voltage 24V DC (-5%/+5%) Output current 200mA The maximum resistance of the battery circuit 300mΩ Ripple voltage 45mV p-p max. Current consumption by PSU systems during battery operation I = 115mA Battery charging current 0,4A The coefficient of temperature compensation of the battery voltage -20mV/ ºC (-5ºC 40ºC) Low battery voltage indication Ubat < 11,5V, during battery operation Short-circuit protection SCP and overload protection OLP F500mA melting fuse at the 24V DC output (requires fuse replacement) Battery circuit protection SCP and reverse polarity connection T2A- F BAT melting fuse (failure requires fuse replacement) Deep discharge battery protection (UVP) U<10V (± 1V) disconnecting (+BAT) the battery Technical outputs: - EPS FLT; output indicating AC - relay type: 0.5A@ 30VDC/50VAC power failure - APS FLT; output indicating battery failure - PSU FLT; output indicating PSU failure - ALARM; output indicating collective failure Optical indication. - AC; LED indicating AC power status - DC; LED indicating 24V DC power status at the PSU output - FAILURE; LED indicating failure Acoustic indication: Fuses: - F AUX - F BAT - F MAIN - green, normal status: permanently illuminated, failure: not lit - green, normal status: permanently illuminated, failure: not lit - yellow, normal status: not lit, failure: permanently illuminated - Piezoelectric indicator ~75dB /0.3m F500mA / 250V T2A / 250V T3,15A / 250V Table 3. Mechanical parameters. Enclosure dimensions 550 x 380 x 200 (WxHxD) [mm] (+/- 2) Mounting 445 x 280 [mm] Net/gross weight: 9,8/10,5 kg Enclosure DC01 steel plate 1 mm, color red (RAL 3001) Terminals Mains supply: Ф0,51 2 (AWG 24-12) Outputs: Ф0,51 2 (AWG 24-12) The BAT battery output: Ф6 (M6-0-2,5) Notes: Convection cooling. 6

Table 4. Safety of Use. Protection class PN-EN 60950-1:2007 I (first) Protection grade PN-EN 60529:2003 IP30 Insulation electrical strength: - between the input (network) circuit and the output circuits of the PSU (I/P-O/P) 3000 V/AC min. - between the input circuit and PE protection circuit (I/P-FG) 1500 V/AC min. - between the output circuit and PE protection circuit (O/P-FG) 500 V/AC min. Insulation resistance: - between input, output, and protective circuit 100 MΩ, 500V/DC Table 5. Operation parameters. Environmental class PN-EN 12101-10:2007 1 Operation temperature -5ºC...+40ºC Storage temperature -25ºC...+60ºC Relative humidity 20%...90%, no condensation Sinusoidal vibrations during operation: 10 50Hz 50 150Hz 0,1g 0,5g Surges during operation 0,5J Direct insolation unacceptable Vibrations and surges during transport According to the PN-83/T-42106 standard 2. Installation. 2.1. Requirements. The power supply unit should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V AC and low-voltage installations. The device is designed for a continuous operation and is not equipped with a power-switch. Therefore, an appropriate overload protection in the power supply circuit should be provided. Moreover, the user shall be informed about the method of disconnecting the mains voltage (usually through assigning an appropriate fuse in the fuse-box. The electrical system shall follow valid standards and regulations. The PSU shall work in a vertical position to ensure free, convection air flow around the enclosure. The rules for power supply, enclosures, shielding, and cable routing- according to application - must be observed in order to meet the requirements of LVD and EMC directives. As the PSU cyclically runs a periodic battery test, during which the connection resistance is measured, pay attention to the proper installation of the battery cables. Connecting cables should be securely connected to battery side terminals and to the power supply connector. 2.2. Installation procedure. CAUTION! Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. To turn off the power, use an external switch where the distance between the contacts of all poles in a disconnected state is at least 3mm. Selection of installation cables should take account 187 of the Regulation of the Minister of Infrastructure on technical conditions to be met by buildings and their location, as amended on 12 March 2009. 1. Mount the power supply to the wall in the selected location using special metal expansion plugs. Do not use PVC plugs. 2. Connect the power cables (~230V) to the L-N terminals of the power supply. Connect the ground wire to the terminal marked by the earth symbol PE. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with the PE symbol on the PSU enclosure. Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a device failure or an electric shock. 7

3. Connect the RJ45-RJ45 cable from the call station of the "CST BUS" to the "MIC" jack on the power supply board. Fig. 4. Connecting the call station to the power supply. 4. Mount the mounting brackets to the call station paying attention to their correct position in relation to the right "P" and left "L" sides. 5. Connect the transmission cable (from the DSO CST-BUS control panel) to the "IN" connector on the power supply board (mark 1..8). 6. If needed, connect the device cables to the technical outputs: - EPS FLT; technical output of 230V AC power failure indication - PSU FLT; technical output of power supply failure indication. - APS FLT; technical output of battery failure indication - ALARM; technical output of collective failure of the PSU When technical outputs require reverse operation move the configuration jumpers (Table 1, point 8). 7. Insert the battery in the designated compartment of the enclosure (Fig. 3 [3]). Connect the battery with the power supply board paying special attention to the correct polarity. 8. Mount the temperature sensor near or directly on the battery. 9. Switch on the 230V AC supply. The corresponding LEDs on the front panel of the power supply should be lit: green AC and green DC. 10. Once the tests and operation control have been completed, the enclosure can be locked 2.3. The procedure for checking the power supply. 1. Check the indication displayed on the front panel of the power supply unit: a) The AC LED should remain lit to indicate the presence of the supply voltage. b) The DC LED should remain lit to indicate the presence of the output voltage. c) LED light DAMAGE off. 2. Check the output voltage after 230V AC power failure. a) Simulate the lack of 230VAC mains voltage by disconnecting the appropriate switch in the electrical installation. I. The AC LED should go out II. The DC LED should remain lit to indicate the presence of the output voltage. III. After approximately 10s the EPS and ALARM technical outputs will change status into opposite. IV. Acoustic indication will be activated. b) Turn on the 230V AC mains voltage again. Indication should return to the initial status within a few seconds. 3. Check whether the lack of continuity in the battery circuit is properly indicated. a) Disconnect the battery cable (230V AC mains supply) during normal operation of the power supply unit. 8

3. PSU operation indication. I. Within 5 minutes the PSU will start signaling a failure in the battery circuit. II. The ALARM LED will start blinking. III. The APS and ALARM technical outputs will change status into opposite. IV. Acoustic indication will be activated. b) Reconnect the wires in the battery circuit. c) The power supply should return to normal operation, indicating the initial status, within 5 minutes after the battery test is completed. 3.1 Optical indication. The PSU is fitted with three LED lights at the front panel FAILURE AC voltage ON - PSU supplied with 230V AC voltage OFF - no 230V AC supply 24V DC output voltage ON - 24V DC voltage at the MIC output of the power supply OFF - no 24V DC voltage at the MIC output of the power supply Collective failure blinking - failure OFF normal operation 3.2 Technical outputs. The power supply is fitted with relay indication outputs changing state upon the occurrence of a specific event: EPS FLT output of 230V AC power failure indication. Output indicating 230V AC power failure. Under normal status with the 230V AC supply on - the output is closed (open *); in the case of power failure the output is switched to an open state (shorted *) after 10 seconds. APS FLT output of battery failure indication. Output indicating failure in the battery circuit. Under normal status with the 230V AC supply on - the output is closed (open *); in the case of failure the output is switched to an open state (shorted *). Failure can be triggered by the following events: - Faulty battery - Undercharged battery - Disconnected battery - High resistance of the battery circuit - Battery voltage below 11,5V during battery-assisted operation - Battery fuse failure - No continuity in the battery circuit PSU FLT output of power supply failure indication Output indicating PSU failure. Under normal status with the 230V AC supply on - the output is closed (open *); in the case of failure the output is switched to an open state (shorted *). Failure can be triggered by the following events: - Battery voltage below 13V - Battery voltage higher than 14,6V - Failure of the battery charging circuit - F AUX fuse failure - Too high battery temperature - Temperature sensor failure - Internal damage of the power supply ALARM technical output of collective failure indication. Output indicating collective failure. Under normal status with the 230V AC supply on - the output is closed (open *); in the case of failure at any EPS, APS, or PSU output, the output is switched to an open state (shorted *). * Depending on the position of the jumper for configuring the relay contacts, see Table 1, item 8 9

4. Maintenance and operation. 4.1. Overload or short circuit of the power supply output (SCP activation) In the case of short circuit or overload of the power supply, the F AUX fuse becomes permanently damaged. Restoration of the voltage at the output requires fuse replacement 4.2. Protection against reverse battery connection. The power supply unit is protected against reverse battery connection. In the case of incorrect connection the FBAT fuse becomes damaged. The return to normal operation is possible only after replacing the fuse and correct connection of the batteries. 4.3. Deep discharge battery protection (UVP). The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing voltage below 10V±1V at the battery terminals will disconnect the battery within 15 seconds. Re-connecting the battery to the power supply occurs automatically once the 230V mains voltage is restored. 4.4. Battery test The PSU performs the battery test every 5 minutes. During the test the power supply controller measures the electrical parameters in accordance with the implemented measurement procedure. A negative result occurs when the continuity of the battery circuit is interrupted, the resistance in the battery circuit is above 300 mω, or when the terminal voltage drops below 12V. The battery test is automatically locked when the power supply is in the mode in which performing the battery test is not possible. Such a state occurs, e.g. during battery-assisted operation or in the case of power supply overload. 4.5. The measurement of the resistance of the battery circuit The power supply unit is fitted with a function that checks the resistance in the battery circuit. During the measurement, the power supply controller takes into account the key parameters in the circuit and in the case of exceeding the limit value of 300m Ohm it indicates failure. A failure may indicate significant battery consumption or loosening of the connection cables. 4.6. Measurement of the battery temperature The power supply unit is fitted with a temperature sensor to monitor the temperature parameters of the installed battery. The measurement of the battery temperature and the charging voltage compensation extend the battery life. 4.7. Maintenance. Technical inspections and maintenance can be performed after disconnecting the power supply from the power network In the case of fuse replacement, use a replacement of the same parameters Re-tighten all screw connections after 4 weeks from installation of the power supply. 2 [9.10]. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http://, www.zasilacze.pl 10