APPENDIX B. Demolitions

Similar documents
CI 3000 Coil Inserter

5.1. EXPLOSIVE TYPES..Elimination of nitroglycerin effects.

Commercial Explosives

QUICKTERM TERMINATION KIT

DSTP20: Fuel Transfer Pump

Coil Inserter Module

INSTALLATION INSTRUCTIONS

Disconnect the negative battery cable!

HD 7700 Setup & Operator Manual

ELECTRICAL CONNECTORS B.1

OZM-72 anti-personnel fragmentation mine Compiled by Vanja Jokic using original Russian military sources, 2011

Installation Instructions

INSTALLATION INSTRUCTIONS

California Friendly Landscape Training

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

User s Manual. Automatic Switch-Mode Battery Charger

Wind Control Panel Instruction Manual (for use with AIR Breeze and AIR 40 12V turbines)

Overcurrent protection

AUTOMATIC SPRINKLER TIMER

SkyHawk M1620 Satellite Modem. Installation and Setup Guide READ ME FIRST

Wind Control Panel Instruction Manual (for use with AIR Breeze and AIR 40 12V turbines)

AirSpeed HC Belt Replacement and Drum. Smart Delivery System USER MANUAL

PRIMADET non-electric delay detonators Dual StoperTM

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Lab Session #1 Initiation Systems and Types of Explosives

MY F150 CrewCab 1. Tools Required E F G. Page 1 of 10 9L3J-19A014-AA Copyright Ford 2013 FoMoCo

Installation and User Manual. with RAIN SENSOR.

RoadRelay 4. Installation Guide

WEBER CARBURETOR TROUBLESHOOTING GUIDE

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

ELECTRIC BENDING IRON

Cantilever Series Mounting Instructions Fullsize Sprinter Van (US) All except WB (AA) present

Tailgate Light Bar Installation by Flopster Feb 2015

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

INSTALLATION INSTRUCTIONS

Using your Digital Multimeter

RP Instruction Manual

WARNINGS AND INSTRUCTIONS for CONSUMERS IN TRANSPORTING, STORING, HANDLING, AND USING EXPLOSIVE MATERIALS

Troubleshooting Title of Bulletin guide for single phase GFCIs Manual machines

PROCEDURE STEPS: WARNING:

DIY Bi-Metallic Strip

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

TIP SHEET T2352, T3396. Installation Tips for RS1 + EVO-ALL 1-BUTTON REMOTE STARTER FOR: Acura RDX PUSH-TO-START / AUTOMATIC

18.5. Electrical Circuits and Safety

British Anti-Tank Mines

EVS RP6020. Instruction Manual

COLD WEATHER START KIT Platinum Mini Split

PRIMADET non-electric delay detonators MS Primadet - millisecond series

Pre-plumbed Blowdown Assembly ½ Model

Body Electrical System

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

NOTES: 1489 N THESTA FRESNO, CA PHONE (559) FAX (559)

Chapter 2 Mobility. Hasty Defense The main obstacle employed is the Threat standard hasty minefield budding block (Figure 2-1).

t!z ESFE~ PARTS AND SUPPLIES ROCKET ASSEMBLY 1. FLYING MODEL ROCKET #2054 .~. 1111l~i '~~

UNIVERSAL ELECTRA-STEER FOR 2 COLUMN 220w Plain w Polished w Plain w Polished

BusPro Series Instruction Manual

XS500 Load Bank. Read all instructions before using the load bank. Contents

TECHNICAL MANUAL OPERATORS INSTRUCTIONS AND ORGANIZATIONAL MAINTENANCE MANUAL SIMULATOR, PROJECTILE AIRBURST, LIQUID: M9 (NSN )

Splicing Procedures 4. 2 Insert the new wire between the parted strands. If more than one wire is being spliced, wrap them in opposite directions. Use

ROADRELAY 5 Installation Guide

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

GM TRUCK BACKUP CAMERA INSTALLATION

Owner s Manual Electronic Harness Controller P/N ASM4250

Stanbury Scarf & Lord Pty Ltd

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

Plastic Tube Flar ing Syste m

Installation Tips for your Remote Start system (for Toyota vehicles) V3.3 revised 1/10/2013

Installation Tips Crimestopper/ProStart Remote Start system + PLJX + DLRM + SPDT (for GM vehicles) T0760 v1.1 updated 2/5/14

Airbag Deactivation Shunt Kit Installation Instructions

Designed for 2014 and newer 1500 Series and 2015 and newer Heavy Duty GM Silverado/Sierra Double Cab vehicles

PRODUCT INSTALLATION GUIDE

BX8848 Installation Instructions 4 Diode Wiring Kit For Motorhomes With Red Tail Lights

Installation Instructions

SB SWITCH CONTROL BOX

MY F150 SuperCab 1. Tools Required. Page 1 of 12 9L3J-19A014-BA Copyright Ford 2013 FoMoCo

Installation Instructions Dual Perimeter Plate Nitrous System (#82185)

This LED flashtube kit covers models 400, 404, 500, 504, 600, 680 & 506.

Model 2300DL Installation Guide

STREET SCENE EQUIPMENT,INC. CONNECTING STREET SCENE SIGNAL MIRRORS

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

Installation Instructions

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

Pure sine wave charger inverter Product Manual

Measurements are expressed in millimeters.

2) Front Airbag Operation (Driver's and Passenger's)

I1 7.5 Pre-Lit Clear Christmas Tree

ASSEMBLY INSTRUCTIONS

OPERATOR, PARTS & INSTALLATION MANUAL BX8894, BX88100


and Original Series Pickup Lift Mounting Instructions Fullsize Chevy & GMC Trucks: 1500 & 2500 LD HD & 3500HD BOLT-ON GUSSET

This chapter contains operational verification, adjustment, and repair/replacement procedures for major

UNSIGNED HARDCOPY NOT CONTROLLED

Electrical Hazard Three factors determine the resistance of a substance to the flow of electricity: conductors insulators extreme caution

Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good t

Kinetic Contraptions. Build a Hovercraft, Airboat, and More with a Hobby Motor. Curt Gabrielson

SUPERHONE Installation * Operation * Maintenance * Replacement Parts

LAWN SPRINKLER, IRRIGATION PUMP

Power Distribution System User s Manual. Model: PDS-100

To increase the height of the trailer increase the length, to reduce the height, decrease the length of the link.

Transcription:

APPENDIX B Demolitions GENERAL There will be times when you have to use demolitions for: Breaching minefield. Breaching wire obstacles. Clearing landing zones. Blowing holes in walls of buildings. Blowing down trees to create obstacles. HOW TO PREPARE FIRING SYSTEMS Information on the preparation and placement of demolition charges is in FM 5-25 and in GTA 5-10-27. This appendix covers the preparation of firing systems that are basic to all demolition work. There are two types of firing systems NONELECTRIC SYSTEM and ELECTRIC SYSTEM. CONTENTS GENERAL.............................B-1 HOW TO PREPARE FIRING SYSTEMS....................B-1 B-1

NONELECTRIC SYSTEM To prepare a nonelectric firing system, take these steps: STEP 1. Clear the cap well of a block of TNT or push a hole about the size of a blasting cap (3 cm [1% in] deep and.65 cm [¼ in] in diameter) in a block of C4 explosive. STEP 2. To help prevent a misfire, cut and discard 15-cm (6-in) length of fuse from the free end of the time blasting fuse. That part of the fuse may have absorbed some moisture from the air through the exposed powder in the end of the fuse. B-2

STEP 3. Determine what length of fuse is needed. To do this, first compute the burning time of a 91.4-cm (3-ft) section of fuse. Divide this burning time by 3 to find the burning time of 30.5 cm (1 ft) of fuse. Next, determine the time it takes to reach a safe distance from the explosion. Now divide the time required to reach that distance by the burn time of 30.5 cm (1 ft) of fuse. This will give the number of centimeters (ft) of fuse needed. STEP 4. Inspect the nonelectric blasting cap to make sure it is clear of foreign matter. STEP 5. Gently slip the blasting cap over the fuse so that the flash charge in the cap is in contact with the end of the time fuse. DO NOT FORCE THE FUSE INTO THE CAP. STEP 6. After seating the cap, crimp it 3.2 mm (1/8 in) from the open end of the cap. Hold it out and away from your body when crimping. B-3

STEP 7. When using TNT, insert the blasting cap into the cap well. When using C4, place the cap into the hole made in the C4 and mold the C4 around the cap. DO NOT FORCE THE CAP INTO-THE HOLE. STEP 8. Insert the free end of the fuse into an M60 fuse igniter and secure it in place by screwing on the fuse holder cap. B-4

STEP 9. To fire the fuse igniter, remove the safety pin, hold the barrel in one hand. Take up the slack, before making the final strong pull. If the fuse igniter misfires, reset it by pushing the plunger all the way in. Then try to fire it as before. If it still misfires, replace it. STEP 10. If a fuse igniter is not available, split the end of the fuse and place the head of an unlighted match in the split. Make sure the match head is touching the powder train. STEP 11. Then light the inserted match head with a burning match or strike the inserted match head on a matchbox. If the fuse burns but the explosive charge does not go off, there is a misfire. Wait 30 minutes before trying to clear it. If the misfire charge was not tamped (nothing packed around it), lay another charge of at least one block of C4 or TNT beside it. If it was tamped, place at least two blocks of C4 or TNT beside it. Do not move the misfire charge. The detonation of the new charge should detonate the misfire charge. B-5

ELECTRIC SYSTEM To prepare an electric firing system, take these steps: STEP 1. After finding a safe firing position and a place for the charge, lay out the firing wire from the charge position to the firing position. Before leaving the charge position, anchor the firing wire to something. Always keep the firing device with you. Do not leave it at the firing position. STEP 2. Check the firing wire with the galvanometers or circuit taster to make sure it does not have a short circuit or a break. This is best done with one man at each end of the firing wire. To check for a short, separate the two strands (the bare ends) of the firing wire at the firing position. B-6

Have the other soldier do the same thing with the other end of the wire at the charge position. At the firing position, touch the bare ends of the two strands to the galvanometer/circuit tester posts. The needle on the galvanometers should not move, nor should the light on the circuit tester come on. If the needle does not move or if the light does not come on, the wire has a break replace it. If the wire has no short when tested, test it for a break. Have the soldier at the charge position twist the bare ends of the strands together. Then touch the two strands at the firing position to the galvanometers/ circuit tester posts. That should cause a wide deflection of the galvanometer needle or cause the circuit tester light to come on. If the galvanometers needle does not move or if the light does not come on, the wire has a break replace it.. B-7

STEP 3. At the firing position, check the blasting cap with a galvanometers or circuit tester to make sure it does not have a short. Remove the short circuit shunt and touch one cap lead wire using the galvanometers, the needle should make a wide deflection. If it does, the cap is good. If the needle fails to move or only makes a slight deflection, replace the cap. of C4 plastic explosive, push a hole in it about the size of a blasting cap. STEP 5. Position the charge. Then splice the lead wires of the cap to the firing wire (pigtail knot). When using the circuit tester, the light should come on when the handle is squeezed. If it does not, replace the cap. STEP 4. Move to the charge position and, if the charge is a block of TNT, clear its cap well if the charge is a block B-8

STEP 6. Insert the cap into the cap well of the TNT and secure it with the priming adapter, or insert the cap into the hole made in the C4 and mold the explosive around the cap. STEP 7. Move back to the firing position and check the wire circuit with the galvanometers or circuit tester (same technique as described earlier). If the circuit checked out and the blasting machine does not set off the charge, there is a misfire. If an untamped charge misfires, investigate at once. If the charge is tamped, wait 30 minutes before investigating, then take these steps: STEP 1. Check the firing wire connection to the blasting machine to be sure that the contacts are good. STEP 2. Make two or three more attempts to fire the charge. B-9

STEP 3. Try to fire it again using another blasting machine. new charge. This should also detonate the misfire charge. STEP 4. Disconnect the firing wire from the blasting machine and shunt (twist together) the ends of the wire. STEP 5. Move to the charge position to investigate. Take the blasting machine with you. STEP 6. Check the entire circuit, including the firing wire, for breaks and short circuits. STEP 7. Make no attempt to remove the primer or the charge. STEP 8. If the fault has not been found, place a new primed charge beside the misfire charge. STEP 9. Disconnect the old blasting cap wires from the firing wire and shunt the ends of the blasting cap wires. STEP 10. Attach the new blasting cap wires to the firing wire and fire the B-10