JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Similar documents
CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

series RVV Variable flow rate controllers

CONSTANTFLOW Volume Flow Controllers

VARYCONTROL VAV Dual Duct Terminal Boxes

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

For installation into ductwork

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

VAV TERMINAL BOXES TYPE: BA BT

Parts and characteristics

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Pressure control damper ERPA

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Ceiling swirl diffusers

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Ventilation grilles for installation into walls, sills or rectangular

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Mechanical mixing box MBM

Fan - Powered Terminal Unit Series Flow

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Pressure relief dampers

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Technical information

Ceiling swirl diffusers

Volume Flow Limiters Type VFL

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

OPTIVENT Housing HVSA, HVSL

Ceiling swirl diffusers with perforated face plate

series Silencers

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Variable Air Volume Dampers

VAV Terminal Units SDS

Ventilation grilles for installation into walls, sills or rectangular

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

Grilles Linear Grilles

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Ceiling swirl diffusers

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Ceiling swirl diffusers with perforated face plate

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

Technical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Smoke damper EKO-SRB1

Regulation and shut-off damper SPB and SPC

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Technical documentation

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

STR Circular VAV Terminal Units

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

FAN POWERED TERMINAL UNITS

Ceiling Swirl Diffuser DQJ

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

VOLUME CONTROL / REGULATING DAMPERS

SINGLE DUCT TERMINAL UNITS

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

Fire damper FK120/FK90 TECHNICAL DATA

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

RETROFIT TERMINAL UNITS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Transcription:

1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

2 VAV regulator, model Description The variable air volume regulators are rectangular control units for use in variable air volume flow systems and single-duct installations. The regulators consist of an air inlet connection manufactured of galvanised sheet and fitted with a cross-shaped sensor that has differential pressure inlets. The control damper has opposed, aerodynamic blades and is manufactured of aluminium. The damper body includes internal airtight seals around its entire perimeter to ensure excellent air tightness. The blades are operated by a gear mechanism to achieve proper friction. The VAV regulator can be fitted with fibreglass thermal-acoustic insulation internally (-DS regulator) upon request. Applications The regulator is installed to supply variable air volume flow to the room, based on variations in the thermal loads or demands of the room. The unit can also be installed for the purpose of controlling the return of air from a room as a function of the incoming air volume, such that the volume maintains a certain level of over pressure or under pressure with respect to the adjacent rooms. Control The air flow regulation is electronic. The control assembly for VAV regulators is composed of the following: 1 Differential pressure sensor. 2 Temperature sensor (not included in the regulator). 3 Controller that receives signals from the temperature and differential pressure sensors. 4 Actuator to modulate the volume control damper, based on the signal received by the regulator 5. The VAV regulator and the actuator are combined in a compact part that includes both functions. The desired maximum and minimum flow rates are set in the VAV regulator and controlled by the actuator according to the signal from the differential pressure sensor; this signal is then converted by the regulator into a flow set point. The VAV regulator varies the air volume within these limits, based on the signal received from the temperature sensor. Flow adjustments and operating tests of all units are performed at the factory.

3 Models and dimensions The dimensions indicated below are standard sizes for the and -DS (internally insulated) VAV regulators. -DS NOMINAL DIMENSIONS, IN MM H 200 300 400 500 600 700 800 900 1000 L 300 400 500 600 700 800 900 1000

4 Technical data. Selection tables Technical data table. Sound power level and pressure loss The following table can be used to obtain the sound power level of regenerated noise (in db/octaves), from a front air flow velocity and a degree of damper opening (pressure loss, in Pa). The data shown in the following table are for VAV regulators with an area of 1 m 2. For other cross-sections, please use the correction factor listed on this page. REGENERATED NOISE % open V (m/s) P est (Pa) Octave bands (Hz) - Sound power (db) L W - db(a) 63 125 250 500 1000 2000 4000 8000 6 2 55 56 52 50 44 44 36 37 52 8 3 64 64 60 58 52 52 45 45 60 100 10 4 70 71 67 64 59 58 51 51 66 12 6 75 76 72 69 64 63 56 56 71 15 10 81 82 78 76 70 70 62 62 78 6 15 55 59 59 59 58 52 43 40 62 8 26 63 66 66 66 65 59 51 47 69 80 10 40 68 72 72 72 71 65 56 53 75 12 58 73 76 77 76 76 69 61 57 79 15 91 79 82 82 82 81 75 67 63 85 3 48 50 56 59 64 67 60 49 40 71 4 85 57 63 65 71 74 67 56 47 78 60 5 133 62 68 71 76 79 73 62 52 83 6 191 67 73 75 81 84 77 66 57 87 7 260 70 76 79 84 88 81 70 60 91 1 23 40 49 46 50 55 53 42 32 59 2 93 56 64 61 65 70 69 57 47 75 40 3 209 65 73 70 74 79 78 66 56 84 4 372 71 79 77 81 86 84 72 62 90 5 581 76 84 81 86 91 89 77 67 95 0,5 37 37 42 40 44 44 47 44 40 52 1,0 146 53 59 57 60 61 64 61 56 69 20 1,5 329 63 69 67 70 71 74 71 66 79 2,0 585 70 76 74 77 78 81 78 73 86 2,5 914 75 81 79 83 83 86 83 78 91 Sound power level correction values, for various control damper cross-sections Area (m 2 ) 0,1 0,15 0,2 0,3 0,4 0,5 0,7 0,9 1 1,2 1,4 1,6 2 Correction -10-8 -6-5 -4-3 -2-1 0 1 2 3 5

5 Technical data. Selection chart Sound power and pressure loss chart, for % opening (20% to 100%) The following chart corresponds to VAV regulators with an area of 1 m 2. For other sections, please use the correction factor listed in the table on the previous page. % damper open L WA [db(a)] Symbols V (m/s) P est (Pa) L WA [db(a)] Frontal air flow velocity through the damper, in m/s Pressure loss in the VAV regulator, in Pa Sound power level, in db(a)

6 Product codes The VAV regulator identification will be coded according to the nomenclature indicated in the table. VAV regulator -DS VAV regulator, insulated L x H Dimensions, in mm Qmin - Qmax Air flow minimum-maximum of setting Coding example: -DS 500x300 **The manufacturer s brand for control components must be specified in the order. **The mechanisms and fasteners are made of corrosion-resistant materials. factory setting