Installation & Operating Instructions

Similar documents
Installation & Operating Instructions

MAINTENANCE & OPERATING INSTRUCTIONS

Please Read this manual before operating your UltraRide Suspension, and keep it for future reference.

Link Mfg. Ltd th St. NE Sioux Center, IA USA

Factors to consider when selecting a diverter valve

SWING CHECK VALVES SERIES 52-SC SERIES 600

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

TactAir 4-Stage PCP Hand Pump. Operation Manual

Hydraulic Angling Ditching Bucket owner s manual. Read before operating. Important safety and operation instructions inside.

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

BAYCO DRY BULK D B D DIXONVALVE.COM. Dry Bulk Products. pages Dry Bulk Replacement Parts. pages Dixon Bayco. Index.

6L Oil-less Air Compressor 53103

Installation, Operation and Maintenance Instructions

Installation Manual. Model Chassis Code Engine Code Year

MOM FRIENDLY. DAD READY.

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

OPERATION AND PARTS MANUAL

Dry Bulk 2009 catalog

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Wall Mount Installation Manual

INSTALLATION INSTRUCTIONS 88029

TS93 EMF T/PT/TDE. Surface applied door closer

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Instructions for MB832 Manual Barrier Ver0614

OPERATIONS MANUAL LEVER CHAIN HOIST

Table of Contents BDU Series Features and Benefits

FT150 MIXER REPAIR KIT INSTRUCTIONS

GA-160 Gas Amplifier

3PC TONNEAU COVER WITH SPORTS BAR INSTALLATION INSTRUCTIONS

SS188HF Toyota Land Cruiser Prado 150 Series KDJ150R 3.0L 4 Cyl. D-4D Diesel (1KD-FTV Engine)

Installation Manual. Model Chassis Code Engine Code Year

Portable Oil Free Silent Series Compressor Operating Instructions

EXTRA WIDE STEEL ROLLATOR

SS730HF NISSAN D40 NAVARA DUAL CAB/R51 PATHFINDER - 2.5L YD25DDTi ENGINE

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

I Button Chemical Dispenser. Overview. Installation Instructions

Medical Treatment Chair. T688 Series How to use guide

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Diesel Engine Shutdown Valve

3 PIECE HARD TONNEAU COVER INSTALLATION INSTRUCTIONS

Suspension Leveling Kits HIGH LOW REGULAR. .f. KT ASSEMBLY AND USAGE GUIDE

INSTALLATION AND OPERATING INSTRUCTIONS

Hopper Loaders S Series

PNEUMATIC SLIDING VALVE

INSTALLATION INSTRUCTIONS

MGM Brakes Service Manual

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and operating instructions EB Pneumatic Control Valve Type and Type Globe Valve Type 3522 ANSI Class 300

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

Omniaire 1000V Instruction Manual-8/05

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

M&H AWWA C508 STANDARD SWING CHECK VALVES

DON T FORGET ABOUT YOUR OVERHEAD DOORS

NECO Pumping Systems

KWIK-LOC TANDEM DOLLIE PARTS MANUAL CRAFTSMEN TRAILER, LLC. 2007

MAINTENANCE GUIDELINES FOR NIBCO ¼ THROUGH 3 CLASS 125, 150, 200 & 300 BRONZE SWING CHECK VALVES FIGURE NUMBERS

Automatic Belt Tensioners:

Maintenance Manual and Illustrated Parts Catalogue Extra EA Chapter 37 Vacuum. Page Date: 8. December Page 1

CIRCLE SEAL CONTROLS

Parts Manual. cascade

Parts Manual. cascade

UTV Universal Stronghold Auto- Latch Double Boot Mount

Vandal Resistant Ringdown/Autodialer Telephone

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

ANTI-SKID BRAKING SYSTEM (ABS)

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Installation, Operation and Maintenance Instructions

INSTALLATION, OPERATION, MAINTENANCE MANUAL

665 Series Dispenser. Metering tip kit

INSTALLATION INSTRUCTIONS

Pump Model P Corrosion Resistant Pump

M&H AWWA C508 STANDARD SWING CHECK VALVES

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

SS732HF NISSAN D40 NAVARA / R51 PATHFINDER 4.0Ltr V6 Petrol (VQ40 Engine) Built: Nissan Motor Iberica, S.A.

Railroad Ball Valves Series 5REB3

Quick Install Lift AL065 Installation Guide & Owners Manual

CHEVY / GMC 1500HD / 2500HD 2WD 8 LUG 7 BASIC KIT

Installation Manual. Bullet Proof Oil Cooler Kit. Neal Technologies, Inc. (patent pending) Updated 12/23/09

3PC TONNEAU COVER INSTALLATION INSTRUCTIONS. Ford Ranger/Mazda BT-50 (without bedliner)

3M Overhaul Service Kit

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Instructions for Porsche PN s * and

SS77HFZ Toyota Land Cruiser 70 series (Wide Nose) Suits: 4.2L 6cyl Diesel (1HZ engine) Replaces Factory Toyota Raised Air Intake (Genuine Snorkel)

Long Tube Header Installation For Dodge Challenger SRT-8 & R/T, Charger SRT-8 & R/T, Magnum SRT-8 & R/T & Chrysler 300 SRT-8 & 300C

3M Overhaul Service Kit

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

Installation instructions

Models P420A-3100 & P420A-5100

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR

ICV & ICVA Flanged Injection Control Valves 2 (DN 50) Type Installation, Maintenance and Operating Instructions

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

INSTALLATION INSTRUCTIONS COUPLING NUT MOUNTED CHAIN UNIT KIT. Dealer Customer Vehicle Truck # P.O. # Unit # Bracket # Chain Wheel Kit#

Dry Bulk Handling Equipment

Brake master cylinder with 25.4 mm (0.999 in.) diameter piston and brake servo, component summary

John Berends Implements Pty Ltd OPERATOR S MANUAL PARTS LIST

2000SR. Installation Instructions May Donovan Enterprises 3353 S.E. Gran Park Way Stuart, Florida

Transcription:

Installation & Operating Instructions For Dixon Bayco 3" Swing Check Manifold Valves for Pneumatic Service For Sales and Service Contact USA: Dixon Bayco USA Chestertown, Maryland Phone: 410-778-2000 Fax: 410-778-4702 Toll Free: 800-355-1991 E-mail: dixonbayco@dixonvalve.com Canada: Dixon Group Canada Limited Innisfil (Barrie), Ontario Phone: 705-436-1125 Fax: 705-436-6251 Toll Free: 877-963-4966 E-mail: isales@dixongroupcanada.com Europe: Dixon Group Europe Ltd Preston, England Phone: +44 (0)1772 323529 Fax: +44 (0)1772 314664 E-mail: enquiries@dixoneurope.co.uk Asia Pacific: Dixon (Asia Pacific) Pty Ltd Wingfield, South Australia Phone: +61 8 8202 6000 Fax: +61 8 8202 6099 E-mail: enquiries@dixonvalve.com.au Mexico: Dixva, S. de R.L. de C.V. Monterrey, N.L Phone: 01-800-00-DIXON (34966) Fax: 01-81-8354-8197 E-mail: contactenos@dixonvalve.com.mx dixonvalve.com

Item No. Qty. Description 1 1 Body 2 1 Flapper Assembly (Silicone or metal seal) 3 1 Flap Valve Yoke 4 6 Bolt 5 6 Washer lock 6 1 Shaft LH 7 1 Shaft RH 8 1 Spring RH 9 1 Spring LH 10 1 Gasket 11 1 Top Cap 12a 1 Adapter 3" (models 3090MA / 3091MA only) 12b 1 Adapter 4" (models 3090MB / 3091MB only) 13ab 1 O-ring (3090MA / 3091MA, 3090MB / 3090MB) Repair Kit 3091RK2 includes 2, 3, 6, 7, 8, 9, and 10 Repair Kits 3090RK2 / 3091RK1 include 2, 3, 4, 5, 6, 7, 8, 9 and 10 Repair Kit 3030RK3 includes items 8 and 9. Security Kit 3030SK includes two drilled bolts (4) and a wire lead seal. Repair Kit 3090RK1 includes item 13AB. 2 090084 R9 3" SCMV

To properly operate and maintain your Dixon Bayco 3090 / 3091 swing check valve the following instructions are provided. Please read with care as improper handling or maintenance may cause a hazardous condition. Do not modify your Dixon Bayco swing check valve for any reason. It can result in a hazardous condition due to operating difficulties or operation malfunction. Disassembly or tampering will void the product warranty. Immediately remove from service any swing check valve that is not performing satisfactorily. Installation Dixon Bayco swing check valves are properly adjusted and ready to use upon leaving the factory. Swing check valves are designed to be tough and to provide long service with reasonable care and handling. 1. Ensure arrow is pointing downstream of product flow when installing. 2. Apply appropriate gasket for square-flanged model. Temperature Dixon Bayco 3090 / 3091 series swing check valves are rated for direct blower mounted service. (400 F / 204 C) 3" SCMV 090084 R9 3

Inspection and Maintenance Swing check valves can fail to operate if not properly maintained. Frequently check for damage, loose or missing parts. Swing check valves assure one-way airflow during the off loading or unloading of product. Swing check valves prevent back flow of product into the blower or piping system. These safety devices consist of a simple flapper valve that swings clear of the air stream during the normal off-loading operation, but will immediately close when there is an air stoppage or airline pressure reversal. Once installed, the valves are often ignored. However, they are a crucial element in the proper operation of the dry bulk air transfer systems and the protection of expensive blower equipment. Swing check valve simplicity and historical durability are probably the reason for inspection complacency. But, swing checks are subject to temperature extremes and vibration fatigue that can affect wear and longevity. Wear in particular can result as flapper and hinge mechanisms vibrate constantly during road travel. Also remember that blowers raise intake air temperatures by as much as 200 F. That means if the outside is 100 F, then airline plumbing (including swing checks) can reach 300 F. High temperatures combined with pulsation stress from the blower and road travel vibration creates a hostile working environment that warrants performance inspections on a regular basis. There are two basic ways to inspect swing checks: (a) visual/manual, on the tanker and (b) removed from tanker, on a test stand. Do not attempt to inspect the valve while in use; this may result in severe damage or injury. 4 090084 R9 3" SCMV

How to Inspect The complete valve assembly may be removed and replaced without removing the valve body from the system. Please note that the shafts and springs are designed for left and right orientation, ensure that these components are located correctly. The colored spring should be used in conjunction with the right hand threaded shaft. 1. Remove the inspection cap/cover and hand operate valve to ensure springs are in good working order and flapper seats properly without restriction. 2. Whilst pulling the flapper forwards, pull upwards on the valve yoke to withdraw the complete flapper assembly (take care to ensure that springs are secure during valve withdrawal). 3. Inspect valve seat and valve for wear or gaps. 4. Inspect for product stuck in flapper assembly or valve seat causing the flapper to hang open. 5. If springs are replaced, please ensure that, after replacement, the valve assembly is free to without excessive resistance. If excessive resistance is felt: - Ensure that the springs are fully pressed onto the shaft. - Reduce spring pre-load by moving torsion spring legs to alternative pre-load stop. The correct amount of pre-load allows the valve to be freely opened to 90. Should problems be encountered replace valve immediately. Your Dixon Bayco 3090 / 3091 swing check valve is designed for minimal flow restriction and low pressure drop during operation. The valve return springs are designed to provide sufficient pre-load to return the valve to the closed position with only limited pre-load. Excessive pre-loading of the return springs may lead to premature failure. 3" SCMV 090084 R9 5

Inspection Frequency Swing check valves should be routinely inspected as part of a preventative maintenance schedule for dry bulk tankers. The units should be given, at a minimum, a visual/manual inspection every 2-3 months. Do not use anything other than genuine Dixon Bayco parts in your Dixon Bayco swing check valve. Repair kits are available for all replaceable parts (refer to parts breakdown for details). Use of nonapproved or modified parts can result in a hazardous condition due to operating difficulties or operation malfunction. Modification or tampering will void the product warranty. Dixon Bayco Warranty For complete warranty information, please refer to the latest Dixon catalog. 6 090084 R9 3" SCMV