Installation and Operation

Similar documents
Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation Guide. Marine Filter SURT023M SURT024M

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Installation Power Management Unit Battery Cables and Battery Harness

Broadband PowerShield. CP27U Models. User Manual

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation and Operation

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Installation and Operation

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

SUA1000I-IN / SUA1500I-IN 230 VAC

Installation and Operation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

Installation and Operation Manual Smart-UPS Tower 220/230/240 Vac SRC1000ICCIND; SRC1000UXIND

Installation and Operation

Installation and Operation

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

BroadBand PowerShield. 20 AHr Battery. User Manual

APC Smart-UPS RT UXI/UXICH

Safety and General Information

Installation and Operation

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Installation and Operation

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

Operation Manual. Smart-UPS Uninterruptible Power Supply. Rack-Mount 2U. 750/1000/1500 VA 120/230 Vac VA 120 Vac. 100/120/208/230 Vac

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Electrical Installation

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

Installation and Operation Manual Back-UPS BR1000-CH

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

Installation and Operation Back-UPS BX550CI-CN

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Technical Specifications. Symmetra PX kw 208 V

Power Distribution Units

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

Operation Manual. Smart-UPS. Uninterruptible Power Supply VA Short-depth Rack-Mount with Lithium-ion batteries. 120 Vac

3000VA 120/208/230VAC

Operation and Maintenance

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Power Distribution Units AP9560 & AP9561

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

MM-AVR UPS Series User s Manual

CTFRP Series Power Supplies

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500 VA Short-depth Rack-Mount with Lithium-ion batteries.

Technical Specifications

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Installation and Operation Manual Back-UPS BR800/1100CI-IN

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

10 Year Limited Warranty

PVI 60KW, PVI 82KW, PVI 95KW

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

English. User s Manual. APC Smart-UPS. 2U Rack and Stack External Battery Pack , Revision 1 5/00

Power. On Your Terms.

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

BATTERY PACK. User's Manual

USER MANUAL English / Español

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

USER GUIDE 1 USER GUIDE

All other marks are trademarks or registered trademarks of their respective holders.

Users Guide for Ac-sync

SUNTURA SOLAR TRACKER

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. 1000/1500 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

EPS Technical Specifications 06/2015.

User Manual Back-UPS BE425M/425M-LM, BN450M/450M-CA

SUNTURA HD SOLAR TRACKER

Installation and Operation Smart-UPS SUA500PDR

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Grid Tied Limiter User Manual

Operating and Installation Instructions

HP190SL Series Slimline Radon Fans

BlinkerBeam Solar Controller

WiFi Tank Level Monitor Installation Instructions

Firstmate Installation Manual and User's Guide May, 2003

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Back-UPS CS Back-UPS CS 350

User s Manual. Complete Off-Grid Solar Kits (100 to 600 Watts) Complete Off-Grid Solar Kit Manual Revision 1.0

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Fifth Wheel Power Hitch Operations Manual

Cabling for power, control, and video must be run to the installation site before the mount is installed.

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Transcription:

Installation and Operation Smart-UPS External Battery Pack Tower/Rack-Mount 2U/3U SRC192XLBP SRC240XLBP1 SRC240XLBP2 oem0141a

Smart-UPS External Battery Pack Tower/Rack-Mount 2U/3U SRC192XLBP SRC240XLBP1 SRC240XLBP2 English

Overview The APC by Schneider Electric Smart-UPS SRC 5/6/8/10 kva is a high performance uninterruptible power supply (UPS). It provides protection for electronic equipment from utility power blackouts, brownouts, sags, and surges; small utility fluctuations and large disturbances. The UPS also provides battery backup power until utility power returns to safe levels or the batteries are fully discharged. Safety Read the Safety Guide included in the package before installing the UPS. Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. Inventory Recycle the packaging. SRC192XLBP (12) (6) (1 pair) (2) SRC240XLBP1/SRC240XLBP2 (12) (12) (1 pair) (2) All models (1) (1 User Manual) 2

Specifications Temperature Operating 0 to 40 C (32 to 104 F) -15 to 45 C (5 to 113 F) Storage charge UPS battery every six months Maximum Elevation Humidity Operating Storage 3,000 m (10,000 ft) 15,000 m (50,000 ft) 0% to 95% relative humidity, non-condensing This unit is intended for indoor use only. Select a location sturdy enough to handle the weight. Do not operate UPS where there is excessive dust or temperature or humidity are outside specified limits. This unit has air vents. Allow adequate space for proper ventilation. Environmental factors impact battery life. High temperatures, poor utility power, and frequent, short duration discharges will shorten battery life. Installation Tower Configuration Install stabilizer brackets oem0076a x4 oem0077a x4 3

Connect External Battery Packs to UPS Battery safety Read and adhere to all safety warnings when the external battery packs are installed. Failure to observe these warnings may result in serious injury, death or damage to the equipment. Do not attempt to install the external battery packs. A qualified electrician should perform the installation of the external battery packs. Practices Precautions Always wear: Goggles or face shields Acid-resistant, insulated gloves Protective aprons Protective overshoes or rubber boots Always Use: Insulated tools Rubber mats to cover batteries during servicing Rubber mats or rubber stands on the floor Adequate lifting devices Remove: watches, rings, and other metal objects from your body Do not lay tools or metal parts on top of battery packs. Lead-acid batteries contain hazardous, toxic materials. Do not open, alter or mutilate battery packs. Internal materials may be harmful to the skin and eyes. Do not dispose of batteries in a fire. There is danger of explosion. Handle, transport and recycle batteries in accordance with local codes and regulations. 4

Installation SRC192XLBP SRC240XLBP1/SRC240XLBP2 1. Set the circuit breaker switch on the rear panel of external battery pack to the OFF position. 2. Remove battery connector cover on both the UPS and the battery pack. Keep the screws. 3. Plug the XLBP cable into the UPS external battery pack receptacle. 4. Secure the cable on the UPS and the battery pack with the screws removed in step 2. 5. Set the circuit breaker switch on the rear panel of the battery pack to the ON position. Oem0070a oem0083a oem0085a 5

Configure UPS Parameters This configuration affects the accuracy of the predicted runtime calculations the UPS performs while running on battery power. Refer to the Battery String Configuration tables at the end of this section for detailed instructions. Smart-UPS RC models must be programed to recognize the number of battery strings connected to the UPS. There are four options available for configuring the UPS to recognize the number of battery strings 1. UPS terminal mode 2. UPS display interface Configure UPS connection settings using UPS terminal mode Connect the serial cable to the serial port on the back of the UPS. If using USB communication to the UPS, disconnect USB cable prior to connecting serial cable. 1. Open a terminal program, such as HyperTerminal From the Desktop, go to: Start, Programs, Accessories, Communication, HyperTerminal 2. Follow the prompts to choose a name and select an icon. Disregard the message, "...must install a modem," if it is displayed. Click Cancel 3. Go to File, Properties. Select the COM port that is connected to your UPS. The port settings are: bits per second - 2400 data - bits 8 parity - none stop bit - 1 flow control - none 4. Click OK in each of two windows 5. Press ENTER Configure the number of battery strings through the display interface menus 1. Press the Enter key into the main menu. Main Menu Status 2. Scroll down to configuration. Main Menu Configuration 3. Press the enter key into the menu of configuration. Language English 4. Scroll down to battery setup by number of battery pack. Ext Battery Packs: 0 5. Select the correct number of battery pack. 6

Configure the number of battery strings using UPS terminal mode 1. Once the blank terminal window is open, follow these steps to enter the number of battery strings: NOTE: Letter key commands are case sensitive. Use capital letters when using letter key commands. 2. Press Y. The UPS will respond with SM in the command box. If the UPS does not respond to the Y command, ensure the serial cable is securely connected to the serial port on the UPS. Use only an APC supplied serial cable. 3. When SM appears in the command box press the > key. The UPS will respond with the number of battery strings connected to the UPS. If the UPS has not been previously programmed to recognize the number of battery strings this number will be 1. 4. Use the + or - keys to change the number of battery strings. OK will appear in the command box. 5. Press > key. The number of battery strings will appear in the command box. NOTE: The + or - keys and the > key must be used again to change the number of battery strings from this point in the programming. 6. Press R. The UPS will respond with BYE in the command box. 7

Battery configuration tables Smart-UPS XLICH Models - Configure the Number of Battery Packs. Each battery pack consists of one 192 V or one 240 V battery module. Count the number of battery packs being used and enter that number. Configuration # of Battery Packs Factory Default UPS with 1 external battery pack 1 SRC192XLBP 5000 VA/6000 VA SRC240XLBP1 8000 VA SRC240XLBP2 10000 VA UPS with 2 external battery packs 2 UPS with 3 external battery packs 3 UPS with 4 external battery packs 4 UPS with 1 external battery pack 1 UPS with 2 external battery packs 2 UPS with 3 external battery packs 3 UPS with 4 external battery packs 4 UPS with 1 external battery pack 1 UPS with 2 external battery packs 2 UPS with 3 external battery packs 3 UPS with 4 external battery packs 4 Smart-UPS UXI/UXICH Models - Configure the Number of Battery Packs. Each battery pack consists of one 192 V or one 240 V battery module. Count the number of battery packs being used and enter that number. Configuration # of Battery Packs Factory Default UPS with 1 external battery pack 1 SRC192XLBP 5000 VA/6000 VA SRC240XLBP1 8000 VA SRC240XLBP2 10000 VA UPS with 1 external battery pack 1 UPS with 2 external battery packs 2 UPS with 3 external battery packs 3 UPS with 1 external battery pack 1 UPS with 1 external battery pack 1 UPS with 2 external battery packs 2 UPS with 3 external battery packs 3 UPS with 1 external battery pack 1 UPS with 1 external battery pack 1 UPS with 2 external battery packs 2 UPS with 3 external battery packs 3 8

Maintenance, Transport and Service Battery Replacement The external battery packs do not have user replaceable battery modules. Contact APC at www.apc.com to order replacement external battery packs. Once the battery packs have been disconnected the connected equipment is not protected from power outages. When the battery packs have been replaced the LED on the display interface will prompt the user to enter a new battery replacement date. Return spent batteries to an appropriate facility for proper disposal and recycling. Prepare the UPS for Transport Service 1. Disconnect the UPS from all external battery packs. 2. Shut down and disconnect all equipment connected to the UPS. 3. Shut down and disconnect the UPS from utility power. 4. Follow shipping instructions outlined in Service on page 9 in this manual. If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in the Troubleshooting section of the UPS manual to eliminate common problems. 2. If the problem persists, contact APC Customer Support through the APC Web site, www.apc.com. a. Note the model number of the UPS, the serial number located on the rear side of the unit, and the date purchased. If you call APC Customer Support, a technician will ask you to describe the problem and attempt to solve it over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). b. If the UPS is under warranty, repairs are free. c. Procedures for servicing or returning products may vary internationally. Refer to the APC Web site for country specific instructions. 3. Pack the UPS in its original packaging. If this is not available, refer to www.apc.com for information about obtaining a new set. a. Pack the UPS properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under warranty. b. Always DISCONNECT THE UPS BATTERY before shipping in compliance with U.S. Department of Transportation (DOT) and IATA regulations. Mark the RMA# on the outside of the package. 4. Return the UPS by insured, prepaid carrier to the address given to you by Customer Support. 9

Contact Information APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Refer to the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Local, country-specific centers: go to www.apc.com for information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. 10

One-Year Factory Warranty The limited warranty provided by American Power Conversion (APC ) in this statement of Limited Factory Warranty applies only to products you purchase for your commercial or industrial use in the ordinary course of your business. Terms of warranty APC warrants its products to be free from defects in materials and workmanship for a period of one year from the date of purchase. The obligation of APC under this warranty is limited to repairing or replacing, at its sole discretion, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence or misapplication or has been altered or modified in any way. Repair or replacement of a defective product or part thereof does not extend the original warranty period. Any parts furnished under this warranty may be new or factoryremanufactured. Non-transferable warranty This warranty extends only to the original purchaser who must have properly registered the product. The product may be registered at the APC Web site, www.apc.com. Exclusions APC shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation or testing. Further, APC shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair, installation, start-up by non-apc designated personnel, a change in location or operating use, exposure to the elements, Acts of God, fire, theft, or installation contrary to APC recommendations or specifications or in any event if the APC serial number has been altered, defaced, or removed, or any other cause beyond the range of the intended use. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. APC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. APC EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, APC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. APC WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, APC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUENTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. NO SALESMAN, EMPLOYEE OR AGENT OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT. Warranty claims Customers with warranty claims issues may access the APC customer support network through the Support page of the APC Web site, www.apc.com/support. Select your country from the country selection pull-down menu. Open the Support tab at the top of the Web page to obtain contact information for customer support in your region. 2009 APC by Schneider Electric. APC, the APC logo, and Smart-UPS are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners. 11

990-3713 9/2009