ROTA PULSE FLOW SENSOR Slip Insertion Paddlewheel (with inductive coil pulse output & built in op-amp circuit)

Similar documents
RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

RPFS. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products 41 Carter Road, Brookvale NSW 2100

LCD Dual Resettable Counter and Rate flowmeters

LCD Dual Resettable counter and Rate flowmeters (Universal Slip Insertion Paddlewheel)

LCD Resettable counter flowmeters (Universal Slip Insertion Paddlewheel (for pipes 20 to 100mm dia.)

MRPU5 - LCD RESETABLE COUNTER FLOWMETERS (Screwed Insertion Paddlewheel)

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

RUN ACCUM. TOTAL STOP BAT LOW HIGH

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

WATER & IRRIGATION METERS QUALITY FLOW METERS FOR THE AGRICULTURE AND AQUIFER MANAGEMENT. Quality Engineered Systems

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

BI-DIRECTIONAL INSERTION METER

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

INSERTION flow sensor for continuous flow measurement

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

PSF50 Paddle flow switch

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

Signet 2517 Brass Paddlewheel Flow Sensor * *

Operating Manual Model- P282 Digiflow Controller

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

DOR Insertion Paddle Wheel Flowmeter

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

Insertion magnetic inductive flowmeter

Electromagnetic Flowmeters. Product Overview.

CORROSION RESISTANT IN LINE FLOW SWITCHES

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

A1 Commercial Grade Meters

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

digital flow meters BW Digi-Meter F-1000

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

DIGIFLO ELECTRONIC FLOWMETER

A1 Commercial Grade Meters

TX 115/215 Hot-tap Insertion Turbine Instructions

MODELS 48 RA 48 BRA2 48 BRA4 48 BRAD 48 RAS 48 RAZ 48 RAD 48 RAC

FLOWX3 F3.60M.S Insertion Magmeter

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

ManuFlo Catalogue

TX101/201 Insertion Turbine Instructions

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

FIRE HYDRANT/HOSEREEL PORTABLE TESTER

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

ISTEC MAGNETIC METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

MX-SERIES OVAL GEAR FLOW METERS

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Magnetic Inductive Flowmeter EP / UMF2 (B)

DOR. Insertion Paddle Wheel Flowmeter/Monitor. for low viscous liquids. Flow range: ,300 l/s to ,000 l/s. Flow velocity range: 0.

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

High Performance Turbine Technology

TX101/201 Insertion Turbine Instructions

flow x3 flow monitoring

TX115/215 Hot-tap Insertion Turbine Instructions

Paddle-wheel flow controller for On/Off control

Flow Sensors & Instruments

MODEL 1100 TURBINE FLOW METER

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

B U I L D I N G C O N N E C T I O N S T H AT L A S T

G2 Industrial Grade Meters

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

Hydro-Flow Model 2200 Installation and Operation Guide B

SeaMetrics Flow Meters and Flow Computers

INSTALLATION AND OPERATION

Paddle-wheel flow controller for On/Off control

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

DTK. OEM Pelton Wheel Flow Sensor

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

ProMinent Beta Solenoid Diaphragm Metering Pumps

PA - Turbine Flowmeter Range

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

FLOWMETERS PRODUCT OVERVIEW

DUALPULSE BI-DIRECTIONAL INSERTION FLOW TRANSDUCER INSTRUCTION MANUAL IMDP DUALPULSE LOCK

Positive Displacement Flowmeters

Model 1100 Turbine Flow Meter

MODELS 46 ARA 46 ARAS 46 ARAC 46 RASD

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

G2 SERIES INDUSTRIAL GRADE METERS

SST Series Sand Media Filtration Systems

Paddle-wheel flow controller with optical principle for On/Off control

Certified according to DIN EN ISO Technical Datasheet. HM Series. Turbine Flow Meters

Magnetic-inductive flow meter for hazardous areas

Transcription:

FEATURES ROTA PULSE FLOW SENSOR Slip Insertion Paddlewheel (with inductive coil pulse output & built in op-amp circuit) DATASHEET ± 2.5% accuracy @ velocity range 0.5 to 8.5 m/sec. ± 1.5% accuracy over linear range 0.7 to 7.0 m/sec. Repeatability of rate ±1.0%. Inductive coil pulse output (built in op-amp circuit) for low current applications (Ideal for dataloggers and other battery powered devices) Maximum process temperature 60 C. Simple installation and maintenance. Voltage supply range of 2.7 to 5 VDC. Large range of pipe adapter fittings: Standard in sizes 15 to 100mm, Long Stem version 110-315mm (upto 500mm) Stainless Steel 17-4PH paddlewheel rotor without magnets. (Standard) -LS (Long Stem) The inserts directly into a large range of pipe adapter fittings available in, Galvanized Iron,, Stainless Steel or Polypipe materials, covering pipe sizes 15 to 100mm (standard sizes), -LS for sizes 110-500mm. This makes the RPFS-LO series units suitable for a wide range of liquid flow measurement, monitoring and batching for battery powered or low current requirement applications. With only one moving part and limited intrusion into the pipe, and combined with its flow-through design, the paddelwheel allows accurate measurement of liquid flows with virtually no head losses. Each of the 4 blades of the rotor (paddlewheel) extends approximately one centimetre into the flowing liquid. The sensor generates a square wave pulse with the frequency output proportional to flow velocity and proportional to pipe diameter. Magnets are not used, thereby eliminating iron particles jamming the rotor. The alloy rotor used also makes the RPFS less susceptible to interference from turbulence and particles hitting the rotor, thereby giving superior flow results. SENSOR SPECIFICATIONS Model (Standard) -LS (Long Stem Version) Type of pulse Near 50% duty cycle pulse Near 50% duty cycle pulse Cable type & length M12 Plug and socket, 5 mtr cable 1/ M12 Plug and socket, 5 mtr cable or 2/ Two mtr flying cable lead Cable conductors 2-core shielded (3 wire) 2-core shielded (3 wire) Fluid temperature 80 C max. 80 C max. Weather rating IP67 IP67 Pressure rating 150psi 400psi Accuracy statement ± 2.5% for 0.5 to 8.5 m/s, ±1% for 0.7 to 7.0 m/s, ± 2.5% for 0.5 to 8.5 m/s, ±1% for 0.7 to 7.0 m/s, Repeatability statement +/- 0.6% +/- 0.6% For Pipe Sizes 15 to 100mm standard, 110 to 315mm (via ManuFlo saddle clamps) > 110 to 500mm (via & connect to customer supplied -f entries on pipe. PERFORMANCE (op-amp circuit) INPUT VOLTAGE DC @3V @5V Standby Current (ma) 5 micro-amps 5 micro-amps Pulsing Current (ma) Pulse switching max. 30mA 30mA Pulse Vpp 0 3 VDC 0 5 VDC Duty Cycle 50% 50% Waveform Square wave Square wave ManuFlo Page 1 MANU ELECTRONICS PTY LTD

SENSOR CONSTRUCTION Model -LS (Long Stem) Body Delron O-rings x 2 Neoprene Neoprene Rotor Stainless Steel 17-4PH Stainless Steel 17-4PH Bushes Delron Delron Axle Tungsten Carbide Tungsten Carbide Lockcap PVDF PVDF Dimensions Overall (approx.) 135L x 30W mm 200L x 30W mm APPLICATIONS Since the RPFS Flow Sensor was first manufactured in 1984, over 30,000 units are now in use worldwide. They are used in a large variety of applications, including measurement of fresh and recycled water in concrete batch plants, measurement of water irrigation, salt water, chlorinated water and countless other low viscosity liquid measurement processes (Note: is not suitable for pulsating flows). The inductive coil sensors are energy misers suitable for low current requirements and are ideal for battery powered applications using FRT303 or ME5 or other battery powered Indicators (up to 150m away). The was specially developed for use with 3 rd party loggers where battery draw or solar powered apps require low current draws is an issue. SPARE PARTS SELECTION OF PIPE DIAMETER Order Code PW PWAH BS020 LC Description Paddlewheel, with bushes Axle for paddlewheel Neoprene O-ring Locking Cap PC5 BSPB SLC M12 Plug-in cable 6m length Standard Standard SST with locating key and locknut Long stem adapter with locating key and locknut Sealer Locking Cap (1) For >315mm diameter pipes: Pulses per Litre = 50273 / [ (Pipe diameter in mm) 2.016 ] (2) NOTE: Due to gravitational forces, the pulse output value can differ up to 6% between a vertical flow that is upwards or downwards. Where possible, perform a calbration check to determine pulse rate given the pipe diameter and flow conditions. Once calibrated, meter will give linear and repeatable results within the flow range. ManuFlo Page 2 MANU ELECTRONICS PTY LTD

INSTALLATION GUIDE Adapter Tee keyway fittings are available in: 1. Class 18 Cat. 19 Slip tees (F-glue-ends) pressure pipe, Sizes: 20, 25, 32, 40, 50, 65, 80 & 100 mm. high pressure saddle clamps: 40, 50, 80 and 100mm. 2. Galvanized Iron threaded connections: BSP (F): pipe sizes 25, 32, 40 & 50 mm; BSP (M) pipe sizes 80 & 100mm. 3. Gunmetal BSP(m) threaded connection end pipe tube tees 20 mm. 4. Polypipe saddle clamps in pipe sizes 40, 50, 63, 75, 90, 110 mm 5. saddles 40, 50, 80 and 100mm. 6. Stainless steel 25mm, others fabricated on request. 7. FOR PIPE SIZES 110mm and larger refer to the RPFS-LS model **Further custom made fittings are available on request. Use ManuFlo BSPB or (Long Stem) or Stainless Steel pipe adapter keyway - with locknut, which has a 1 OD BSP thread for screwed insertion into 1 (female BSP) half-sockets which can be welded directly to pipe, the BSPB fittings can be coupled to any female entries including saddle clamps (Fig 1) Installation Conditions IMPORTANT: A minimum of 10x pipe diameter before (upstream of) the sensor and at least 5x pipe diameter after sensor of straight pipe section must be fitted, with no bends, reductions, enlargements, restrictions, valves etc within this section. This will help eliminate flow turbulence to ensure optimum accuracy performance (Fig 3 below) The RPFS sensor must measure in a full pipe flow section (Fig 2) Can be installed in a horizontal, inclined or vertical pipe position. (Note: If mounted in horizontal or inclined pipe, make sure insertion position of sensor is at top or 45 from top, not on the underside). FIG.2 FIG.1 FIG.3 IMPORTANT: ELECTRICAL INSTALLATION / DATA Cable connection (M12 plug where fitted): (M12 PLUG VERSION) Black = Pulse Brown = +3 to 5Vdc Blue = 0V / Ground (FLY WIRE VERSION) White = Pulse Red = +3 to 5Vdc Shield = 0V / Ground # If connecting to non-manuflo equipment, a 2K2 pull-up resistor may be required between (+) and Pulse. For extra cable length, use shielded cable only! WARNING: To avoid electrical interference the should not be installed within 30cm of any AC fields, otherwise 50Hz could be detected and create oscillations. ManuFlo Page 3 MANU ELECTRONICS PTY LTD

MAINTENANCE Recommended Periodic Checks: With clean liquids, sensor check of the paddle wheel is recommended once every year. In applications with reclaimed or contaminated fluids, regular quarterly maintenance checks are recommended. Removal of RPFS from Pipe Fitting Square Keyway Type Nipple Adaptor:(see FIG 5) 1 - Unscrew the black locking cap (anti-clockwise). 2 - Place a small to medium sized flat thin bladed screwdriver in the join where the insertion sensor body meets the (See FIG 4), twist the screw driver to prize the two apart till the slots clear the keyways, then pull or twist upwards until the sensor is released (never pull via the cable). Removal of RPFS from Pipe Fitting Triangular Keyway Type Nipple Adaptor:(see FIG 6) 1 - Unscrew the black locking cap (anti-clockwise). 2 - Hold the neck of the Tee piece in your left hand, grasp the RPFS body with your right hand and turn slowly anti-clockwise until the sensor hydraulically raises out of slot then pull upwards out of the socket (never by the cable). **When returning the sensor to insert so the keyway and slots line up then then push down until they locate. Screw the black locking cap clockwise to hold the sensor in place (hand tightened only). Cleaning: 1 - If the paddlewheel (rotor) and or sensor body is coated with scale, immerse the sensor section in diluted hydrochloric acid, scour gently if required. 2 - For ease of removal or refitting of sensor we strongly recommend to lubricate the body O-rings using petroleum jelly. 3 - If the paddlewheel requires servicing, push out the axle using a small hole punch or similar implement, remove the paddle wheel and service or replace rotor and/or axle as required (spare parts available from ManuFlo). Fault Diagnosis & Rectification: If the RPFS sensor ceases to count, the paddlewheel may be blocked, remove inspect and clean as described above. If the RPFS pulses when there is no flow, a nearby 50Hz AC field is probably causing these false counts. Move the flow sensor away from the 50Hz field, or move the source of the field if practical. If the standard cable length supplied is not sufficient and needs extending contact ManuFlo for suitable screened cable and never run extended cable across or near to other cables that are potential EMF sources. ManuFlo Page 4 MANU ELECTRONICS PTY LTD

ORDER CODES FOR PIPE ADAPTOR FITTINGS Material GAL Polypropylene Polypropylene STAINLESS BRASS BRASS Type T-Piece slip T-piece Saddle Clamp Saddle Clamp Saddle Clamp T-Piece T-piece Socket For Gal pipe Pressure pipe Pressure pipe Pressure pipe Poly Pipe Black S/Steel pipe pipe 20 mm 20 BRA20 25 mm GAL25 ( -T2) 25 SS25 BRA25 32 mm GAL32 32 BSOC: 40 mm GAL40 40 40SC SCP40 SC40 50 mm GAL50 50 50SC SCP50 SC50 63 mm SC63 65 mm 65 SCP65 75 mm SC75 80 mm GAL80 80 80SC SCP80 SC80 80 mm GAL80-F (Table D flanged) 90 mm SC90 100 mm GAL100 100 100SC SCP100 100 mm GAL100-F (Table D flanged) 110 mm SC110-LS 125 mm SCP125-LS SC120-LS 140 mm SC140-LS 150 mm 150SC-LS SCP150-LS 160 mm SC160-LS 200 mm 200SC-LS SCP200-LS SC200-LS 225 mm SCP225-LS SC225-LS 250 mm SCP250-LS SC250-LS 280 mm SC280-LS 300 mm 300SC-LS SCP300-LS 315 mm SC315-LS 500 mm pipe socket for 25-100mm pipes also BSPB & BSOC: pipe socket for 100-500 mm pipes also Long Stem Galvanised iron threaded ends BSP (female) Note: 25mm can be supplied with straight pipe sections already fitted (Part GAL25-T2) T-piece Class 18 Cat 19 Glue-in (female) 1100 kpa 1400 kpa 150mm: 1600 kpa > 150mm: 1000 kpa Poly-pipe agricultural Saddle Clamps 150mm: 1600 kpa > 150mm: 1000 kpa Stainless Steel 316 T-piece. BSP (female) threaded entry T-piece BSP (female) threaded entry pipe socket & BSPB s (see Fig 1 Page 3) GAL80-80mm Galvanized Iron pipe adapter (80mm ɸ x 600mm long) Stainless Steel adapter for 25-100mm pipes Due to continuous product improvement, specifications are subject to change without notice. BSPB brass adapter for 25-100mm pipes ** Pipe fitting options for the RPFS are as per the table however other fitting types may also be available on request**