Eligible Renewable Generation (ERG) Application INSTRUCTIONS

Similar documents
TERMS AND CONDITIONS

Municipality Generator Interconnection Application Single Meter Application Part I

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

Please Refer to Attached Sample Form

2018 Solar Home & Solar Share Home Program Manual

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Electrical District No. 3 SOLAR Q & A

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

NET METERING APPLICATION

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

MISSOURI SERVICE AREA

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Lassen MUD PV BUYDOWN PROGRAM Photovoltaic Systems Guidelines

Duke Energy Carolinas North Carolina Interconnection Request Checklist

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

Net Metering Service. Customer Information Package

APPLICATION Net Energy Metering Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

To: Honorable Public Utilities Board Submitted by: /s/ Barry Leska AGM Energy Resource Planning. From: Alan Hanger Approved by: /s/

White River Electric Association, Inc. Net Metering Information & Service Requirements

Consumer Guidelines for Electric Power Generator Installation and Interconnection

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

2018 Solar Installer Training. March 2018

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

IGNITION INTERLOCK MANUFACTURER RENEWAL AGREEMENT

Contents. Solar Select TM Frequently Asked Questions

Renewable Net Metering Program Appendix ESD APX 001 1

RENEWABLE ENERGY PROGRAM Step 1, Section 1 ENROLLMENT FORM FOR LEASED RESIDENTIAL AND SMALL COMMERCIAL PHOTOVOLTAIC AND WIND TURBINE SYSTEMS

REVISION NO.: 7 EFFECTIVE: 07/07/16

ELECTRICAL DISTRICT # 2

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

06/05/2018. COMMUNITY SOLAR OVERVIEW For Generation Owners and Subscribers

HydroGenerations PROGRAM HANDBOOK

Taxicab and Vehicle for Hire- New Driver Packet

CHOCTAWHATCHEE ELECTRIC COOPERATIVE, INC RESIDENTIAL SERVICE--NET METERING RIDER

RIDER NM NET METERING

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

City Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.

Your Friendly and Caring Member Cooperative. Consumer Guidelines for Electric Power Generator Installation and Interconnection

Emergency Vehicle Application Package

JEA Distributed Generation Policy Effective April 1, 2018

Should I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson

Shedding Light on S lar Overview of Solar Finance

Non-Residential Solar Energy Photovoltaic (PV) Packet

Louisiana Net Metering Service. Customer Information Package

Electric Vehicle Charging Station Incentives PROGRAM HANDBOOK

ADOPT INTERCONNECTION AGREEMENT FORMS FOR CUSTOMERS INSTALLING GENERATION EQUIPMENT PURSUANT TO REGULATION 23.

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

Residential Photovoltaic (PV) Packet

Solar*Rewards Frequently asked questions system size and customer usage

Solar Net Metering and Billing FAQ

City of Washington, Kansas Electric Department. Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources

The brand you can trust.

WOLFEBORO MUNICIPAL ELECTRIC DEPARTMENT NET METERING PILOT PROGRAM. Customer-Owned Renewable Energy Generation Resources (25 Kilowatts or Less)

APPLICATION Net Energy Metering (NEM2) Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

London Hydro Connection Checklist

TILLAMOOK PEOPLE S UTILITY DISTRICT

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Renewable Energy System - Electricity System Connection Application Form

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT

Qualifying trucks must be a Class 3 to Class 8 truck with a history of operating in Hunts Point and/or Port Morris.

Freeing The Grid Resource for better solar policy

24. SOLAR INCENTIVE PROGRAM II

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Connecting your home or small business generation

NEW HAMPSHIRE ELECTRIC COOPERATIVE S (NHEC) ABOVE THE CAP NET METERING INTERCONNECTION APPLICATION INFORMATION

2018 Clean Diesel Rebate Program

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

PG&E California Solar Initiative (CSI) & Net Energy Metering (NEM) Interconnection Webinar. March 26, 2009

LIBERTY UTILITIES (CALPECO ELECTRIC) LLC SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No.

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT AGRICULTURAL PUMP ENGINE COMPONENT

NET ENERGY METERING RIDER Rider NEM. Certain words, when used in this Rider NEM shall be understood to have the following meanings:

Application to Amend Net Metering Service under RS Appendix B. Revised RS 1289 Clean and Black-lined

City of, Kansas Electric Department. Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No.

Interconnection Process for Generation Systems

Rider 11 Partial Requirements Service (PRS)

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

The following permits are required to install a solar PV system with a maximum power output of 10 kw or less:

Southern California Edison s Charge Ready Home Installation Rebate Pilot (CRHIRP) Sample Supporting Documents

Consumers Energy Net Metering

PSNH INTERCONNECTION REQUEST

Interconnection Process Simplification Webinar

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Expedited Permitting Process for Electric Vehicle Charging Stations

Please Refer to Attached Sample Form

ATTACHMENT 14 RESOLUTION NO. 5888(14) Supersedes Schedule NEM of Resolution No. 5592(09) Schedule NEM NET ENERGY METERING

2017 Solar Installer Training. October 2017

Solar Power Installation Application

MCCOOK PUBLIC POWER DISTRICT McCook, Nebraska BOARD POLICY NUMBER 488

December 13, This document was filed with the Board of Public Utilities on December 13, It is awaiting final approval by BPU staff.

Louisville Gas and Electric Company

EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A

Transcription:

INSTRUCTIONS THIS DOCUMENT CONTAINS: ERG Application INSTRUCTIONS ERG Application INFORMATION ERG Application FORM ERG Application CHECKLIST Please read the INSTRUCTIONS and INFORMATION before completing and submitting the FORM. General Instructions for Completing the FORM A. New Solar Customers (New ERG Customers) If installing new solar only, complete all items EXCEPT 5 and 6. If installing new solar and battery storage, complete ALL items. B. Existing ERG or NEM Customers If expanding your solar only, complete all items EXCEPT 5. Complete item 4 for your additional solar and item 6 for your combined solar system. If adding battery storage to your existing solar only, complete all items EXCEPT 4. If expanding your solar and adding battery storage, fill out ALL items. Complete item 4 for your additional solar and item 6 for your combined solar and battery system. Interconnection Fees The interconnection application fees under Rider ERG are: $330 for residential installations $660 for commercial and multi-family installations up to 50 kilowatts (kw), and Minimum $1,100 for installations greater than 50 kw. AMP will provide an estimate for these fees if in excess of the minimum. These fees apply to new ERG installations and expansions of existing ERG systems to include additional generation or battery systems. Existing NEM are subject to these fees when installing new battery storage capacity. Item Instructions 1. AMP Customer-Owner Information: Provide the required customer information, including street address where the system will be installed and AMP account number for existing customers. 2. Installer Information: If customer intends to install the system, check Customer Owner box. If not, provide installer contact information. If there are multiple installers, provide the information for all installers. 3. System Owner Information: Provide system owner information if different from AMP Customer Owner. Generation Application Form 9-18-18 V1.4 Page 1 of 6

INSTRUCTIONS 4. New or Additional Generation System: Provide the information for new generation installations OR for the additions made to an existing system. It may be useful to review the general discussion of PV system specifications and installation guidelines at: http://www.energy.ca.gov/reports/2001-09-04_500-01- 020.PDF. a. PV Modules: Enter the manufacturer's name, model number, watts per module as reported by the CEC, and quantity of photovoltaic modules in the system. b. Inverters: Enter the manufacturer's name, model number, and efficiency (as reported by the CEC) of the inverter(s) in the system. c. Capacity and Energy Production: For solar PV systems, multiply the PTC watts per module, quantity of modules, and inverter efficiency to calculate the total AC system capacity. 5. Battery Storage System (if applicable): Enter the battery manufacturer s name, battery model, quantity, total battery energy storage capacity, continuous power rating, maximum power rating, and the intended use of your battery system (e.g. partial home backup, self-consumption, etc.) 6. Combined System (if applicable): Enter the rated capacity for your entire generation system (existing plus additions). If installing a battery system, indicate the combined capacity of your generation and battery storage system. 7. Installed System Cost: Enter total cost of the system, including equipment and installation. 8. Required Attachments: In addition to the completed application form, submit the following documents: a. Signed copy of the AMP Interconnection Agreement b. Drawing submittals (Required to obtain building permit only) i. Site Plan & System Layout ii. 1-Line or 3-Line Diagram iii. Equipment data and/or Cut-sheets iv. Elevation Drawing c. Declaration Page(s) of customer s homeowner or business liability insurance policy coverage Generation Application Form 9-18-18 V1.4 Page 2 of 6

Solar Rebate Program Availability INFORMATION AMP s Net Energy Metering (NEM) Solar Rebate Program has been fully subscribed and no further applications will be accepted under Rider NEM. All new installations will be under Rider ERG. For existing NEM customers, expanding generation capacity or adding storage will not affect your status under NEM, provided that the expanded system complies with the requirements of Rider NEM. Existing NEM customers who sign a new AMP Interconnection Agreement upon expansion or addition of a storage system will retain their original 10-year interconnection agreement length for NEM purposes. System Requirements All Customer-Owners must accept the terms and conditions contained in the AMP Interconnection Agreement For Residential, Commercial, or Municipal Electrical Generation Facilities or the AMP Interconnection Agreement for Federal Agencies (AMP Interconnection Agreement), and obtain necessary building permits from the City of Alameda. Consistent with AMP s ERG Rider, the capacity of an eligible renewable generator must not exceed 1,000 kw (CEC-AC). One customer is defined as the load served by one meter. Systems with a total capacity in excess of 25 kw (PV rated capacity plus continuous battery output) may be subject to additional distribution studies. All installations must comply with the California Electrical Code. For complete system requirements, please refer to the ERG Plans and Installation Requirements, which can be found at http://www.alamedamp.com/environment/installing-solar/forms-documents. Changes to System or Ownership A Customer-Owner must notify AMP at least 60 days prior to any change in ownership of a system or system relocation. AMP will conduct a mandatory site inspection upon reinstallation. Additionally, a system relocation, change in capacity, or addition of a battery system will require new building permits from the City of Alameda, a new AMP Interconnection Agreement, and current proof of insurance. Generation Application Form 9-18-18 V1.4 Page 3 of 6

FORM START: Type of Installation (see INSTRUCTIONS) Check all that apply: Installing new PV System only Installing new PV system and storage Expanding existing PV system ERG Customer Adding storage to existing PV system ERG Customer NEM Customer NEM Customer 1. AMP Customer Owner (Physical Site of Installation) Residential Commercial Municipal Name on AMP Account: AMP Account #: Installation Address: Alameda, CA 9450 Email: Phone: Fax: 2. Installer Information Customer-Owner Other Installer (shown below) Company Name: Contact Name: Address: Phone: Fax: Email: 3. System Owner Information (if different from AMP Customer- Owner above, i.e., leased system) Company Name: Contact Name: Address: Phone: Fax: Email: 4a. New or Additional Generation (PV) System (see www.gosolarcalifornia.org/equipment/index.html) Module Manufacturer: Module Model #: CEC Watts/Module: Quantity: Inverter Manufacturer: Inverter Model #: Efficiency: Quantity: 4b. New or Additional PV System Rated Capacity and Energy Production CEC Watts/Module Quantity of Modules Inverter Efficiency = System Rated Capacity = Watts AC 5. Battery Storage System (if applicable) Manufacturer: Model: Quantity: Total Battery Capacity kwh Continuous Power Rating: Maximum Power Rating: Intended Use: kw kw Generation Application Form 9-18-18 V1.4 Page 4 of 6

6. Combined System (if applicable) Total PV Rated Capacity: kw 7. Installed System Cost Total cost of system: $ 8. Required Attachments Signed copy of AMP Interconnection Agreement Declarations Page(s) of customer s insurance FORM Total PV Rated Capacity + Battery Continuous Power: kw 9. Final Generating System Specifications (Upon Completion) If the system components change between the approval of the Generation Application Form and the interconnection of the system, a new Generation Application Form must be completed with the final installed components, signed, and returned to AMP. Check if this is a revised final application. AGREEMENT Each of the Undersigned declares under penalty of perjury that: 1) Information provided in this form is true and correct to the best of my knowledge, 2) Site of the installation is located within Alameda Municipal Power s service territory, 3) Customer s intent is to operate the system at the listed site of installation for its useful life. Customer-Owner (Signature): Date: System Owner (Signature): (If different from Customer) Date: Please email, mail or drop-off your Generation Application Form & attachments to AMP s Customer Resources Department: Email solar@alamedamp.com Mail or Drop-off Alameda Municipal Power Renewable Generation Program 2000 Grand Street P.O. Box H Alameda, CA 94501 Generation Application Form 9-18-18 V1.4 Page 5 of 6

Date Sequential Steps Notes CHECKLIST 1. Energy audit (OPTIONAL) Call AMP at (510) 748-3900 to schedule a free energy audit. 2. Application and Attachments Submit (via mail,email, or drop-off) the following to AMP s Customer Resources Department: Generation Application FORM Signed copy of AMP Interconnection Agreement Declarations Page(s) of customer s insurance policy Interconnection fees (if applicable) AMP will review the application to insure the system meets our criteria for interconnection. AMP will send an email or letter confirming receipt of all required documents. 3. Building permit Obtain building permit at the Permit Center in City Hall, located in Room 190 within the Community Development Department. For more information, please call (510) 747-6800. To check status of the permit application, go to the epermit Portal: http://alamedaca.gov/epermit-portal. The following system drawings should be submitted with the permit application: Site Plan & System Layout 1-Line or 3-Line Diagram Equipment data and/or Cut-sheets Elevation Drawing 4. Electrical inspections 1. Upon completion of any installation which includes battery storage, send an email request to AMPInspect@alamedamp.com. Please include the permit number, address, and contact information in the email to schedule an AMP electrical inspection. If you are not able to send an email request you may call (510) 814-5676 for assistance. NOTE: If installing new solar or expanding existing solar systems, an AMP inspection is not required prior to scheduling final building permit inspection. 2. Call Permit Center at (510) 747-6830 to schedule final building permit inspection. Email a copy of the final building permit to solar@alamedamp.com to complete interconnection. Generation Application Form 9-18-18 V1.4 Page 6 of 6