EC series GMS30CS-AU 50

Similar documents
EP series WPS100S-AU rpm,3-phase/5-wiring

EP series WPS800S rpm,3-phase/5-wiring

EP series WPS150BS-AU rpm,3-phase/5-wiring

WPS60/S EP Series. Features:

WPS20/S EP Series. Features:

GMS200C/S EC Series. Features:

GMS350C/S EC Series. Features:

GMS100C/S EC Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

WPS100/S EP Series. Features:

WPS350/S EP Series. Features:

WPS150/S EP Series. Features:

WPS250/S EP Series. Features:

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

DIESEL GENERATING SETS GMS240C6S. NOISE LEVEL: Your Partner for Power

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

GMS1400C / GMS1400CS. Features: EC Series

GMS800C/ Features:

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

WCS2000 / WCS2000S. Features: WCS Series

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

WPS1000 / WPS1000S. Features: EP Series

TPD2250H6.3 TECHNICAL DATA

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GMP400PX/ Features:

WPS625 / WPS625S. Features: EP Series

GMP80PX/ Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

WPS1250 / WPS1250S. Features: EP Series

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Better Soundproof, Better Life!

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

GMS100C / GMS100CS. Features: EC Series

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

1 / Genset general description

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

DS100C6S. 2 Years or 2000 Hours Warranty. Power Your Dream! Enclosed structure, Small in size, High safety, Easy installation and operation

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

WPS100 / WPS100S. Features: EP Series

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

1 / Genset general description

Technical specification

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

Standby Amper VOLTAGE

Standby Amper VOLTAGE

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

Rental Power QSB7 series engine

Super Silent, Superior Life!

Standby Amper VOLTAGE

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

13,000 Watt Diesel Generator AGi13P E

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5

Powered by Cummins Model:YN-95C

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

Diesel generator set QSB7 series engine

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

1 / Genset general description

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

10,000 Watt Diesel Generator AGi9P E

K26M POWER 240 MONO 230 MONO 220 MONO

FE - C KW / 650KVA 600KVA

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

20 KW / 25 KVA LIQUID COOLED POWERED by

APD-ULJ250. Standby Power

500 KW / 625 KVA POWERED by

Diesel generator set QSK23 series engine

Rental Power QSL9 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Engine Make. (1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Weifang Ricardo Generator

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Transcription:

EC series GMS30CS-AU 50 Hz @1500rpm,3-phase/5-wiring 1 Standards &Conditions Design Standards The designs and the productions are in conformity with: Conformite Europeenne (CE) ISO8528-5:2005 GB/T2820.5-2009 AS 3000-1997 AS 3010.1-1988 Environmental Operating Conditions Installation place: Outdoors or indoors (well ventilated). Ambient temperature: -25 to 45.The coolant heater is needed when the temperature is below 5 Humidity: Less than 90%. Altitude: Below one thousand (1000) meters above sea level. 2x12V sealed for life maintenance free battery Lockable battery isolator switch Powder coated canopy 50 radiator Oil pump on the engine Non-returning valve for fuel inlet hose of the engine Steel base frame with forkslots Vibration isolators between the engine/alternator and base frame Base fuel tank for 40 hours running Drain points for fuel tank Breather valve for fuel tank General technical data Factory Inspection Inspection items. Protection devices working test. Starting ability in normal temperature. 50% rated power load moment capability. Voltage deviation and speed variation: 0%, 25%, 50%, 75%, 100%, 110% Load. Painting Process the manufacturer's standard. The customer could also choose the color which the manufacturer offers. 2 General Features Cummins engine 4B3.9G1 Close coupled to a Stamford alternator PI144K Microprocessor control module PLC-7320 SCHENIDER main circuit breaker: 3-Phase 63A Rotate speed governor: Mechanical governor Excitation System: Self ExcitedSHUNT A.V.R.Model: AS480 Key switch Emergency stop switch ATS (automatic transfer switch) receptacle Remote run connextor Model... GMS30CS-AU Structure type... R Tank capacity...270l Dry weight...1398.2kg Noise level @7m...N/A Dimensions L W H... 2588x1101x1708mm Standby Power... 32kVA/26kW Prime Power... 30kVA/24kW Voltage 380V 400V 415V 440V Ampere 45.6A 43.3A 41.7A 39.4A Genset Fuel Consumption Frequency/Load 25% 50% 75% 100% 110% 50Hz (L/h) 1.6 3.2 4.8 6.4 7.0

Diesel engine Engine Manufacturer/Brand...Cummins Engine Model...4B3.9G1 Dimensions L W H...765 582 908mm Dry Weigh (approx.)...308kg Number of Cylinders...4 Bore...102mm Stroke...120mm Displacement...3.9L Compression Ratio...16.5 Type of injection... Direct injection Intake System... Natural aspirated Intake Resistance... 4.98kPa Cooling System...Water cooled Fan... Pusher Battery Voltage... 12/24V Type of Fuel...0# or ASTM2 Type of Oil... API-CG4/CH4 or ACEA-E3/E5 Oil Capacity...9.5L Type of Coolant... Glycol mixture Coolant Capacity...19.6L Back Pressure... 10.1kPa Standby Power...27kW Continuous Power...24kW Fuel Consumption(100%load)...229g/kW.h Alternator Alternator Manufacturer/Brand... Stamford Alternator Model...PI144K Exciter...Brushless Cooling Fan... Plastic Windings...100% copper Insulation Class... H Winding Pitch...2/3 Terminals...12 Drip Proof... IP23 Altitude... 1000m Overspeed...2250rpm Air Flow... 0.135m³/s(50HZ),0.165m³/s(60HZ) Voltage Regulation...±1.0% Total harmonic TGH / THCat no load < 1.5 % - on load < 5% Telephone Interference...THF<2%;TIF<50 PLC-7320 Control System PLC-7320 is an advanced control module based on microprocessor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, and automatically start the engine when the mains is abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automatically shut down the engine and indicate the engine failure. Microprocessor control, with high stability and credibility Monitoring and measuring operational parameters of the mains supply and genset Indicating operation status, fault conditions, all parameters and alarms Multiple protections; multiple parameters display, like pressure, temp. etc. Manual, automatic and remote work mode selectable Real time clock for time and date display, overall runtime display, 250 log entries Overall power output display Integral speed/frequency detecting, telling status of start, rated operation, overspeed etc. Communication with PC via RS485 OR RS232 interface, using MODBUS protocol

4 Overall Dimensions

5 Control System

1000020732-B5 E 12.2011