INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

Similar documents
INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEMS SENSOR ACTIVATED ROYAL CONCEALED and EXPOSED URINAL FLUSHOMETERS

Royal Flushometer PARTS LIST

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

Maintenance Guide. OPTIMA Components:

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

G2 Optima Plus Flushometer

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED SLOAN EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED CROWN & CROWN II FLUSHOMETER EXPOSED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

INSTALLATION INSTRUCTIONS FOR SOLIS SOLAR-POWERED SENSOR-ACTIVATED CONCEALED FLUSHOMETERS

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

AquaVantage AV ZER6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

ETF-600 Sensor Operated Lavatory Faucet

Reducing Your Water Footprint

AquaSense AV Closet ZEMS Series Automatic Systems Sensor-Operated AquaVantage Flushometer Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED ROYAL EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS ROUGH-IN

AquaSense ZTR Series

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

Installation Instructions

AquaSense ZTR Series

Installation Instructions

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

Sloan Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 6. SLIP JOINT GASKETS AND RINGS

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

INSTALLATION INSTRUCTIONS FOR SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM ROYAL AND REGAL XL CONCEALED CLOSET AND URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

Installation Instructions

Sensor-Operated Exposed Systems ZEMS6200 ZEMS ZEMS ZEMS6201 ZEMS6203

Sloan & Zurn Flush Valves

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

AquaSense AV ZER Series

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

Installation Instructions

GENUINE REPAIR PARTS FOR

Installation Instructions

AquaSense AV TM ZEMS Series

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

Optima Flushometers Current style Royal (after 09/26/10)

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

AquaSense TM ZEG Series

AquaVantage Z6000AV Series

Aquaflush Z6000 Series

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

Installation Instructions

INSTALLATION INSTRUCTIONS FOR DOUBLE AND TRIPLE STATION SENSOR ACTIVATED SOLID SURFACE LAVATORY SYSTEMS

Installation Instructions

AquaSense ZEMS G2 Series

AquaSense ZTR Series

AquaSense AV ZER Series

TABLE OF CONTENTS Flushometer Section

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Model 1001/1001HPS Drinking Fountain

AquaSense TM ZTS6200EV Series

AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES

Installation Instructions

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

Installation and Maintenance Instructions

FOR TECHNICAL ASSISTANCE

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

Transcription:

Code No. 0816170 Rev. 2 (12/11) INSTLLTION INSTRUCTIONS FOR CONCELED CLOSET ND URINL FLUSHOMETERS Model 140 Model 195 Concealed Closet Flushometer 1-1/2 Exposed ack Spud MODEL 140 MODEL 154 Concealed Closet Flushometer 1-1/2 Exposed Top Spud MODEL 142 MODEL 153 Concealed Closet Flushometer 1-1/2 ack Spud MODEL 143 MODEL 144 MODEL 150 MODEL 152 Concealed Urinal Flushometer ack Spud MODEL 190 MODEL 195 Concealed Urinal Flushometer Exposed Top Spud MODEL 192 MODEL 197 LIMITED WRRNTY Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries. THERE RE NO WRRNTIES WHICH EXTEND EYOND THE DESCRIPTION ON THE FCE HEREOF. IN NO EVENT IS SLON VLVE COMPNY RESPONSILE FOR NY CONSEQUENTIL DMGES OF NY MESURE WHTSOEVER. PRIOR TO INSTLLTION Check to make certain that the L dimension shown on the flushometer package is correct for your application. Determine the L dimension for your application by using the following formula: L dimension = Wall Thickness (To Nearest Whole Inch) + 2-3/4 Prior to installing a concealed flushometer, perform the following functions as illustrated in the Rough-in Diagrams on Pages 2 and 3. ore a hole in wall for ctuator. ore a [1 (25 mm) for Model 197 only] hole in wall for piping, if required. Install closet or urinal fixture. Install drain line (NOT supplied by Sloan). Install water supply line. Note: Concealed valves are supplied with double handle opening to allow for installation of Control Stop on either the left or right side of the valve (refer to illustration in Step 4). IMPORTNT: INSTLL LL PLUMING IN CCORDNCE WITH PPLICLE CODES ND REGULTIONS. WTER LINES MUST E SIZED TO PROVIDE N DEQUTE VOLUME OF WTER FOR ECH FIXTURE. FLUSH LL WTER LINES PRIOR TO MKING CONNECTIONS. Sloan s flushometers are designed to operate with 10 to 100 psi (69 to 689 kpa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VLVE IS DETERMINED Y THE TYPE SELECTED. Consult fixture manufacturer for minimum pressure requirements. Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum flowing pressure of 25 psi (172 kpa). With the exception of Control Stop Inlet, DO NOT use pipe thread sealant or plumbing grease on valve components or couplings! TOOLS REQUIRED FOR INSTLLTION Sloan -50 Super-Wrench, Sloan -109 Plier Wrench or smooth jawed spud wrench Drill to bore 1½ (38 mm) and/or hole(s) in wall (see rough-in)

ROUGH-IN MODEL 140 14-1/2 (368 mm) 10 (254 mm) MODEL 142 9 (229 mm) 7-1/2 (191 mm) 10 (254 mm) 13 (330 mm) 4 (102 mm) MODELS 143/144 + THICKNESS 10 (254 mm) MODEL 152 MODEL 143-14-1/2 (368 mm) MODEL 144-10-1/2 (267 mm) 24 (610 mm) MODEL 143-13 (330 mm) MODEL 144-9 (229 mm) 22-1/2 (572 mm) MODEL 153 MODEL 154 24 (610 mm) 17-1/2 (445 mm) 24 (610 mm) With the exception of the Control Stop Inlet, do NOT use pipe thread sealant or plumbing grease on valve components or couplings. 2 22-1/2 (572 mm) 4 (102 mm) NOTE: Water Closet Valves with -2.4 Model Designation Deliver 2.4 gpf (9.0 Lpf) CENTERLINE This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve s performance.

ROUGH-IN (CONTINUED) MODEL 190 NOTE: Requires (25 mm DN) MODEL 192 NOTE: Requires (25 mm DN) 14-1/2 (368 mm) 13 (330 mm) 14-1/2 (368 mm) MODEL 195 3/4 I.P.S. (20 mm DN ) MODEL 197 3/4 I.P.S. (20 mm DN ) 13-1/2 (343 mm) 12 (305 mm) 13-1/2 (343 mm) 7 (178 mm) 1 (25 mm) CENTERLINE CENTERLINE 1 - INSTLL OPTIONL SWET SOLDER DPTER (ONLY IF YOUR PIPE DOES NOT HVE MLE THRED) ND INSTLL CONTROL STOP For Sweat Solder applications, slide Threaded dapter onto water supply pipe until end of pipe rests against shoulder of dapter. Sweat solder the dapter to water supply pipe. THREDED DPTER Install the Sloan ak-chek Control Stop to the water supply line with the outlet positioned as required. OUTLET K-CHEK CONTROL STOP WTER PIPE IRON PIPE NIPPLE OR COPPER PIPE WITH SWET SOLDER DPTER NOTE Concealed valves are supplied with double handle opening to allow for installation of Control Stop on either the left or right side of the valve (refer to illustration in Step 4). 3

2 - INSTLL VCUUM REKER FLUSH CONNECTION ssemble Pipe, Elbows, Couplings, Nylon Slip Gaskets, Rubber Gaskets and Flanges as illustrated on back page. Hand tighten all Couplings. VCUUM REKER IMPORTNT: WHEN CUTTING SCORED PIPE TO FIT, LEVE MINIMUM OF 1-1/4 (32 mm) OF SCORING TO ENSURE PROPER ENGGEMENT WITH COMPRESSION S. FLUSH CONNECTION 3 - MOUNT CTUTOR SSEMLY TO Remove ctuator Shaft End, Coupling and Mounting Nut from ctuator ssembly. -31 GSKET CTUTOR SHFT END MOUNTING NUT (FIXTURE SIDE) Insert Shaft of ctuator ssembly through the wall opening from fixture side of wall. C Install Mounting Nut, Coupling and ctuator Shaft End to ctuator ssembly. Hand tighten Mounting Nut to wall. Securely tighten ctuator Shaft End to ctuator assembly. CTUTOR SSEMLY 4 - INSTLL FLUSHOMETER Lubricate tailpiece O-ring with water. Insert djustable Tailpiece into Control Stop while mounting Flushometer to ctuator ssembly. Tighten ctuator and Tailpiece Couplings by hand. lign Flushometer directly above the Vacuum reaker Flush Connection. ssemble Vacuum reaker Flush Connection to Flushometer. Tighten Vacuum reaker Coupling by hand. 4-1/4 (108 mm) MX. Use a Sloan -50 Super-Wrench, Sloan -109 Plier Wrench or smooth jawed spud wrench to secure all couplings. This will eliminate damage to chrome or special finish that normally occurs when slip-joint pliers, pipe wrenches or other toothed tools are used. 5-1/4 (133 mm) MX. -31 GSKET DJUSTLE TILPIECE C D Use a wrench to tighten the following couplings in the order shown. lign Flushometer ody and securely tighten first the Tailpiece Coupling (1), then the ctuator Coupling (2), then the Vacuum reaker Coupling (3), then all Flush Connection Couplings (4) and finally the Spud Coupling (5). Using a wrench, securely tighten ctuator Mounting Nut to wall. FLUSHOMETER ODY TILPIECE 1 G-44 GSKET CONTROL STOP NOTE Maximum adjustment of the Sloan djustable Tailpiece is 1/2 (13 mm) IN or OUT from the standard (centerline of Flushometer to centerline of Control Stop). CTUTOR SSEMLY 2 If roughing-in measurement exceeds 5-1/4 (133 mm), consult factory for longer tailpiece. 3 VCUUM REKER 4 5 FLUSH CONNECTION S SPUD 4

5 - FLUSH OUT LINE ND DJUST CONTROL STOP C D Shut off Control Stop by turning handle CLOCKWISE. Then remove Flushometer Cover. Lift out the inside Parts ssembly as a complete unit. Reinstall Flushometer Cover and tighten with wrench. Open Control Stop. Turn on water supply to flush line of any debris or sediment. Shut off Control Stop and remove Flushometer Cover. Reinstall Inside Parts ssembly and Flushometer Cover. Tighten Cover with wrench. Open Control Stop and activate Flushometer Valve. djust Control Stop to meet flow rate required for proper cleansing of fixture. Open Control Stop COUNTERCLOCKWISE ONE FULL turn from closed position. ctivate Flushometer. djust Control Stop after each flush until the rate of flow delivered properly cleanses the fixture. Sloan Flushometers are engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when the plumbing fixture is cleansed after each flush without splashing water out from the lip ND a quiet flushing cycle is achieved. Never open Control Stop to where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture must be able to accommodate a continuous flow from the valve. Never open the Control Stop to where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture must be able to accommodate a continuous flow from the valve. TROULESHOOTING GUIDE 1. Flushometer does not function (no flush).. Control Stop or Main Valve is Closed. Open Control Stop or Main Valve.. Handle or Push utton ssembly is worn. Install Sloan Handle Repair Kit (C-70-) or replace handle or push button. C. Relief Valve is worn. Replace Royal Performance Kit (Royal) or Inside Parts Kit (Regal). 2. Volume of water is not sufficient to siphon fixture.. Control Stop is not open wide enough. djust Control Stop for desired delivery of water volume.. Urinal flushometer parts installed in a Closet flushometer. Replace inside Urinal Flushometer parts with proper Closet Flushometer parts. C. Incorrect Dual Filtered Diaphragm ssembly (Royal Flushometers) or Inside Parts Kit (Regal Flushometers) is installed in flushometer; for instance, Urinal assembly inside a Closet flushometer, or Low Consumption assembly inside a higher consumption fixture. Determine the flush volume required by the fixture and replace Royal Performance Kit or Inside Parts Kit. Use valve label and markings on fixture for reference. D. Water supply volume or pressure is inadequate. If no gauges are available to properly measure supply pressure or volume of water at the Flushometer, then remove the Relief Valve from the Dual Filtered Diaphragm ssembly (Royal) or Inside Parts Kit (Regal), reassemble the flushometer and completely open the Control Stop. If the fixture siphons, more water volume is required. IMPORTNT LWS ND REGULTIONS PROHIIT THE USE OF HIGHER FLUSHING VOLUMES THN LISTED ON FIXTURE OR FLUSHOMETER. If the fixture does not siphon or if a Low Consumption flush is required, steps must be taken to increase the water supply pressure and/or volume. Contact the fixture manufacturer for minimum water supply requirements of the fixture. 3. Flushometer closes off immediately.. Ruptured or damaged diaphragm. Replace Royal Performance Kit (Royal) or Inside Parts Kit (Regal).. For Regal Flushometers n enlarged bypass orifice from corrosion or damage. Replace Inside Parts Kit. 4. Length of flush is too short (Short Flush).. For Regal Flushometers The Diaphragm ssembly and Guide ssembly are not hand tight. Screw the two assemblies hand tight.. For Regal Flushometers n enlarged bypass orifice from corrosion or damage. Replace Inside Parts Kit. C. Dual Filtered Diaphragm ssembly (Royal) or Inside Parts Kit (Regal) is damaged. Replace Royal Performance Kit or Inside Parts Kit. D. Incorrect Dual Filtered Diaphragm ssembly (Royal) or Inside Parts Kit (Regal) is installed in Flushometer; for instance, Urinal assembly inside a Closet Flushometer, or Low Consumption assembly inside a higher consumption fixture. Determine the flush volume required by the fixture and replace Royal Performance Kit or Inside Parts Kit. Use valve label and markings on fixture for reference. E. Handle or Push utton ssembly is worn. Install Sloan Handle Repair Kit (C-70-) or replace handle or push button. 5. Length of flush is too long (Long Flush) or continuous.. For Royal Flushometers Metering bypass hole in Diaphragm is clogged. Remove the Dual Filtered Diaphragm ssembly. Remove the Primary and Secondary Filter Rings from the Diaphragm and wash under running water. Replace Royal Performance Kit if cleaning does not correct the problem.. For Regal Flushometers Relief Valve (-19-) is not seating properly or bypass orifice is clogged. Disassemble the working parts and wash thoroughly. NOTE: SIZE OF THE ORIFICE IN THE YPSS IS OF UTMOST IMPORTNCE FOR THE PROPER METERING OF WTER INTO THE UPPER CHMER OF THE FLUSHOMETER. DO NOT ENLRGE OR DMGE THIS ORIFICE. REPLCE INSIDE PRTS KIT IF CLENING DOES NOT CORRECT PROLEM. C. Supply line water pressure has dropped and is not sufficient to close the valve. Close Control Stop until pressure is restored. D. Dual Filtered Diaphragm ssembly (Royal) or Inside Parts Kit (Regal) is damaged. Replace Royal Performance Kit or Inside Parts Kit. E. Incorrect Dual Filtered Diaphragm ssembly (Royal) or Inside Parts Kit (Regal) is installed in Flushometer; for instance, Urinal assembly inside a Closet flushometer, or Low Consumption assembly inside a higher consumption fixture. Determine the flush volume required by the fixture and replace Royal Performance Kit or Inside Parts Kit. Use valve label and markings on fixture for reference. F. White Closet Relief Valve has been used in a Urinal flushometer. Replace Closet Relief Valve (-19-C) with lack Urinal Relief Valve (-19-U). G. Inside Cover is cracked or damaged. Replace the Inside Cover (-71). H. Conditions in the piping system may contribute to the noise. degree of high pressure in the piping may be relieved by adjustments to Control Stop. Other noises created by loose pipes, lack of air chambers, inadequate pipe sizes, etc., are problems that must be discussed with the building engineer. 6. Chattering noise is heard during flush.. Inside Cover is damaged. Replace Inside Cover (-71).. For Regal Flushometers -156- Segment Diaphragm has been installed upside-down. Reposition the Segment Diaphragm properly (see markings on the Diaphragm). 7. Leaking at Handle or Push utton ssembly.. The -39 Seal is worn or deteriorated. Install new -39 Seal. NOTE: The -39 Seal will easily slide onto the -40 ushing if it is wet.. Handle gasket has been omitted. Install -31 Handle Gasket or Sloan Handle Repair Kit (C-70-). C. Valve Handle ushing is worn. Install Sloan Handle Repair Kit (C-70-). When further assistance is required, please contact your local Sloan Representative or Sloan Technical Support at: 1-888-SLON-14 (1-888-756-2614) or visit us online at: www.sloanvalve.com 5

CRE ND CLENING DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean Flushometers that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Flushometer from any splattering of cleaner. cids and cleaning fluids will discolor or remove chrome plating. PRTS LIST Item Part Description No. No. 1 Valve ody 2 H-730- ak-chek Control Stop 3 K-46 Gasket 4-6 Coupling 5 C-43-3 (76 mm) Push utton ctuator ssembly 6 C-9- lind Nut Push utton ctuator ssembly 7-12- Lever ctuator ssembly 8 V-500- ¾ (19 mm) Vacuum reaker ssembly R 8 V-500-1½ (38 mm) Vacuum reaker ssembly R 9 F-2-W ¾ (19 mm) Slip Joint Coupling R 10 F-15- ELL with ¾ (19 mm) Tail R (Models 195 and 197) 11 F-2-1½ (38 mm) Slip Joint Coupling 12 F-21 1½ (38 mm) Double Slip Elbow 13 F-2-1½ (38 mm) Coupling with S-21 Gasket (for Model 154, Order Part Number F-5-) 14 F-110 1-1/4 (32 mm) Outlet Tube 15 F-2-U 1-1/4 (32 mm) Slip Joint Coupling R 16 F-2- Slip Joint Coupling (Set of Two) 17 F-102 Outlet Tube CP (for Models 143 and 144, Order Part Number F-100) 18 F-7 Flange (Not Furnished with Models 143 and 144) 19 F-5- Spud Coupling ssembly CP 20 F-25- Elbow ssembly 21 F-100 Outlet Tube R (for Model 154, Order Part Number F-102) 22 F-15- Elbow ssembly CP 23 F-15- ELL with 3/4 (19 mm) Tail CP (Model 197) 24 F-5-1-1/4 (32 mm) Spud Coupling ssembly CP 25 F-5-3/4 (19 mm) Spud Coupling ssembly CP 26 F-25-1-1/4 (32 mm) Elbow ssembly 27 V-500- Vacuum reaker ssembly R (Model 150) F-22 1 (25 mm) Female Outlet R F-2- Coupling with S-21 Gasket Part number varies with valve model variation; consult factory. Manufactured in the U.S. by Sloan Valve Company under one or more of the following patents: U.S. Patents. 5,295,655; 5,542,718; 5,558,120; 5,564,460; 5,730,415; 5,865,420; 5,887,848; 5,967,182. Other Patents Pending. ak-chek, Para-flo, PERMEX, Turbo-Flo MODEL 140 MODEL 142 MODEL 143 MODEL 144 8 8 8 16 20 20 12 12 17 12 18 18 17 19 19 22 MODEL 150 27 12 5 6 7 2 16 MODEL 153 MODEL 152 MODEL 154 INSTLL 8 WITH 8 8 FLNGE GINST 13 SPUD 16 16 22 16 19 21 12 17 18 12 17 18 19 MODEL 190 MODEL 192 MODEL 195 MODEL 197 8 8 8 8 14 3 OPTIONL (SEE PIPING DETIL T RIGHT) 4 16 INSTLL WITH FLNGE GINST SPUD 1 21 20 13 11 15 16 26 10 9 10 23 12 12 13 17 18 24 18 25 NOTE: The information contained in this document is subject to change without notice. SLON HEDQURTERS 10500 Seymour venue Franklin Park, IL 60131 Phone: 1-800-9-VLVE-9 or 1-800-982-5839 Fax: 1-800-447-8329 www.sloanvalve.com 2011 SLON VLVE COMPNY Code No. 0816170 Rev. 2 (12/11) 6