Safety door-handle system STS

Similar documents
Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Technical data. Standards: IEC/EN BG-GS-ET-15

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Solenoid interlock AZM 200 The non-contact interlock.

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Guard locking systems for the protection of man and machine

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Safety Sensor CSS 180 Product Information

Door locking devices. 4 Schmersal Industrial Switchgear

AZM300 More than just a solenoid interlock

Floor and fine adjustment switches

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Safety switches / Position switches / Command devices

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Operating instructions Solenoid interlock AZM 170

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Safety Switches with Separate Actuator SKC

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Safety switches with separate actuator

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Position switches FR series

Operating instructions Solenoid interlock AZM About this document. Content

Installation and Operating Instructions

Installation and Operating Instructions

Datasheet - MV8H Y

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Safety switches with separate actuator

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Under the aspect of simplified

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Position switches FR series

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Switches with manual reset

LR-LX-LK-LW Safety Switches with separate actuator

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

NHP SAFETY REFERENCE GUIDE

Safety switches for hinged doors

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

HS5E Miniature Interlock Switches with Solenoid

FL series position switches

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety switches for hinges

D4DL. Guard Lock Safety-door Switch. Model Number Structure

SG-B1 SERIES / SG-A1 SERIES

Safety Switches NP GP TP. More than safety.

Transponder-coded. with guard locking

Safety rope switches with reset for emergency stop

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

BETA Switching Switches and Light Indicators

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Safety technique. Emergency Stop Module BH 5928, BI 5928

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

Standard Interlock Safety Switches

More than just a solenoid interlock AZM300

HS1C Interlock Switches with Solenoid

3SE3 1 SIGUARD Position Switches

Prewired position switches FF series

Position switches FD series

LK Position Switches TECHNICAL DATASHEET.

Emergency pull-wire, Belt-alignment, Slack-wire switches. Automation. Catalogue // SYSTEMATIC CONTROL SWITCHGEAR

Safety rope switch with reset for emergency stop

HS6B Series Subminiature Interlock Switch

HS1E Series Full Size Solenoid Locking Switches

Door Interlock Switches

Workshop Solenoid Interlocks

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Transponder-coded. with guard locking

Door Interlock Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

Safety switches with solenoid and separate actuator

Safety rope switch without reset for simple stop

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Transcription:

Safety door-handle system STS

Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks can be mounted inside or outside the hazardous area. No additional handles or levers are required on the safety guard. The door handle is latching. The STS is available with an emergency handle to open the safety guard from within the hazardous area. a lockout tag against unintentional locking. a centring device. The centring device, which is also suitable as end stop, provides for a proper centring of the safety guard, thus enabling a smooth insertion or extraction of the actuator and can be used with all types of actuators. Hazardous areas of machines and plants can be so large, that the machine can be entered completely by personnel. The Machinery Directive requires that in this case personnel cannot be inadvertently locked into the hazardous area. To prevent this situation, the Schmersal solenoid interlocks can be fitted with an emergency exit system. This allows personnel to evacuate the hazardous area easily. By opening the emergency release, the safety circuit of the machine is interrupted and the machine is shut down. However, in order not to endanger personnel that could be inside the hazardous area during the machine start-up or restart, a few aspects have to be taken into account. First of all, the start button must be installed in a location where the operator has a complete overview of the hazardous area. In addition, the start button must not be accessible from inside the hazardous area. Secondly, it is strongly recommended to use a safety control module with a monitored start circuit. These safety control modules enable only a trailing edge signal from the start button, i.e. they enable when the button is released, not when it is pressed. The trailing edge control module can thus detect a failure in the start button (e.g. contact welding) and manipulation. The safety control modules of the Schmersal Group include monitored start function. 2

zardous areas Since solenoid interlocks are either locked or unlocked by a solenoid, they require different solutions for manual unlocking in power-off condition (for example during machine installation or maintenance) than for unlocking during machine operation. Manual release During the mounting and installation of machinery fitted with spring-to-lock (power to unlock) solenoid interlocks require a way of opening the safety guard during a power failure, usually by means of a tool such as a triangular key. The Schmersal solenoid interlocks are fitted with such an auxiliary unlocking mechanism, the so-called manual release (Fig. 2 and 3). Upon operation of the manual release, the positive break safety contacts are simultaneously opened, thus preventing unexpected machine restart. Emergency exit The emergency exit allows an intentional opening of the safety guard from within the machine without tools, for example when personnel trapped inside a machine must quickly evacuate the hazardous area (Fig. 1, 2 and 4). Emergency release With an emergency release, the safety guard can be opened from outside the hazardous area without the operator using any tool, for example when a fast intervention into the hazardous area is required to guarantee process safety. Unlocking is possible without special tools, resetting however requires a repairlike intervention. Fig. 2: Mounting of an AZM 41 TEI solenoid interlock with emergency exit inside the hazardous area and manual release outside the hazardous area Fig. 3: Mounting of an AZM 161 solenoid interlock with manual release outside the hazardous area Fig. 1: Mounting of an AZM 161 T solenoid interlock with emergency exit inside the hazardous area Fig. 4: Mounting of an AZM 41 T solenoid interlock with emergency exit inside the hazardous area 3

Selection table: Safety door-handle system Actuator Mounting position actuator Door hinge Safety switch with sepa AZ 16 With emergency handle inside right AZM AZ 16-STS30-01 * left AZ 16-STS30-02 * AZM outside right AZ 16-STS30-0 AZM left AZ 16-STS30-06 AZM Without emergency handle inside right AZM AZ 16-STS30-03 * left AZ 16-STS30-04 * AZM outside right AZ 16-STS30-07 AZM left AZ 16-STS30-08 AZM * For actuators mounted on the inside, mounting plate MP TG-01 (see page 14, not included) must be used to fix the door handle to the profile. View from inside the hazardous area View from outside the hazardous area 4

ate actuator Solenoid interlocks Safety sensor AZ 330 AZ 41 AZM 161 AZM 41 ICS AZ 330-STS30-01 * AZ 41-STS30-01 * AZM 161-STS30-01 * AZM 41-STS30-01 * AZ 330-STS30-02 * AZ 41-STS30-02 * AZM 161-STS30-02 * AZM 41-STS30-02 * AZ 330-STS30-0 AZ 41-STS30-0 AZM 161-STS30-0 AZM 41-STS30-0 ICS 4 ST1-B30-0 AZ 330-STS30-06 AZ 41-STS30-06 AZM 161-STS30-06 AZM 41-STS30-06 ICS 4 ST1-B30-06 AZ 330-STS30-03 * AZ 41-STS30-03 * AZM 161-STS30-03 * AZM 41-STS30-03 * AZ 330-STS30-04 * AZ 41-STS30-04 * AZM 161-STS30-04 * AZM 41-STS30-04 * AZ 330-STS30-07 AZ 41-STS30-07 AZM 161-STS30-07 AZM 41-STS30-07 ICS 4 ST1-B30-07 AZ 330-STS30-08 AZ 41-STS30-08 AZM 161-STS30-08 AZM 41-STS30-08 ICS 4 ST1-B30-08

Safety door-handle system AZ 16 Technical data AZ 16-STS30-88 max. 100 60 max. 100 93 Thermoplastic enclosure Long life Double insulated X 3 cable entries M16 x 1. Large wiring compartment High level of contact reliability with low voltages and currents Available with LED Available with AS-Interface Safety at Work Shearing force 1,000 N Door handle latching Lockout tag against unintentional locking available Centring device available Standards: IEC/EN 60947--1 EN 1088 BG-GS-ET-1 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing Actuator: stainless steel 1.4301 Protection class: IP 67 to EN 6029 Contact material: silver Contact type: changeover with double break Zb, or 2 NC contacts or 3 NC contacts, galvanically separated contact bridges Switching system: A IEC 60947--1 slow action, NC contact with positive break Termination: screw terminals -ST: Connector M 12 x 1.4 poles Cable size: max. 2. mm 2 (incl. conductor ferrules) Cable entry: 3x M 16 x 1. U imp : 6 kv U i : 00 V I the : 10 A Utilisation category: AC-1, DC-13 I e /U e : 4 A / 230 VAC 4 A / 24 VDC Max. fuse rating: 6 A gl/gg D fuse Positive break travel: 8 mm Positive break force: 10 N for each NC contact fitted Ambient temperature: 30 C + 80 ºC Mechanical life: > 1 million operations Latching force: 30 N for ordering suffix r 138 40, 7 23 116 6, 96 6, 17 12-3 102 2 0 0 6, AZ 16 STS30-02/-04/-0/-07 102 2 AZ 16 STS30-01/-03/-06/-08 17 6, 12-3 96 116 40, 7 23 138 Approvals H C D AZ16-➀zvk-➁-➂ N Replace Description ➀ 1 NO/1 NC 02 2 NC 03 3 NC 12 1 NO/2 NC ➁ Without LED G24 With LED ➂ Cable entry M 16 M20 Cable entry M 20 ST Connector M12 x 1 (only for 2 contacts) Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (for variant -0 and -06 incl. mounting plate) Ordering example To order, first choose the desired safety switch and then the door handle system: for example AZ 16-02zvrk-ST and AZ 16-STS30-01. Accessories see page 14. Mounting inside, Mounting outside, AZ 16-STS30-01 AZ 16-STS30-02 AZ 16-STS30-03 AZ 16-STS30-04 AZ 16-STS30-0 AZ 16-STS30-06 AZ 16-STS30-07 AZ 16-STS30-08 The drawings are always shown with a view to the switch. 6

Safety door-handle system AZ 330 9 max. 100 60 max. 100 100 Metal enclosure Long life High level of contact reliability with low voltages and currents 1 cable entry M20 x 1. Shearing force 1,000 N Door handle latching Lockout tag against unintentional locking available Centring device available Actuating head: Technical data Standards: IEC/EN 60947--1 EN 1088 BG-GS-ET-1 Enclosure: light-alloy diecast, paint finish Actuator: brass, blue chrome-plated Protection class: IP 67 to EN 6029 Contact material: silver Contact type: changeover with double break Zb, or 2 NC contacts, or 3 NC contacts, galvanically separated contact bridges Switching system: A IEC 60947--1 slow action, NC contact with positive break Termination: screw terminals Cable size: max. 1. mm 2 (incl. conductor ferrules) Cable entry: 1x M 20 x 1. U imp : 4 kv U i : 20 V I the : 10 A Utilisation category: AC-1 I e /U e : 4 A / 230 V Max. fuse rating: 6 A gl/gg D fuse Positive break travel: 10.7 mm Positive break force: N for each NC contact fitted Ambient temperature: 30 C + 90 C Mechanical life: 1 million operations AZ 330-STS30-4 184 23 116 68, 6, 6, 46 108 17 20 0 12-3 0 12-3 20 17 108 6, AZ 330 STS30-02/-04/-0/-07 AZ 330 STS30-01/-03/-06/-08 46 6, 116 68, 184 23 4 90 270 Approvals H AZ 330-➀-➁-➂ N Replace Description ➀ 03-zk 3 NC 12-zük 1 NO/2 NC ➁ 1637 Gold contacts ➂ U90 Actuating head can be rotated 90 for door hinge left U270 270 rotation for door hinge right Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (For variant -0 and -06 incl. mounting plate) Ordering example To order, first choose the desired safety switch and then the door handle system: for example AZ 330-12-zük-U90 and AZ 330-STS30-02. Mounting inside, Mounting outside, AZ 330-STS30-01 AZ 330-STS30-02 AZ 330-STS30-03 AZ 330-STS30-04 AZ 330-STS30-0 AZ 330-STS30-06 AZ 330-STS30-07 AZ 330-STS30-08 Accessories see page 14. The drawings are always shown with a view to the switch. 7

Safety door-handle system AZ 41 88 max. 100 60 max. 100 93 Metal enclosure 2 switches with different actuating functions in a single enclosure Long life High level of contact reliability with low voltages and currents 2 cable entries M20 x 1. Adjustable ball latch to 00 N Shearing force 30,000 N Door handle latching Lockout tag against unintentional locking available Centring device available Technical data Standards: IEC/EN 60947--1 EN 1088 BG-GS-ET-1 Enclosure: light-alloy diecast, paint finish Actuator: brass, blue chromed-plated Protection class: IP 67 to EN 6029 Contact material: silver Contact type: changeover with double break Zb or 2 NC contacts, galvanically separated contact bridges Switching system: A IEC 60947--1 slow action, NC contact with positive break Termination: screw terminals Cable size: max. 1. mm 2 (incl. conductor ferrules) Cable entry: 2x M 20 x 1. U imp : 4 kv U i : 20 V I the : 6 A Utilisation category: AC-1 I e /U e : 4 A / 230 VAC Max. fuse rating: 6 A gl/gg D fuse Positive break travel: 3.8 mm Positive break force: min. 31 N Ambient temperature: 2 C + 70 ºC Mechanical life: > 1 million operations Latching force: 0-00 N (adjustable) AZ 41-STS30-210 16 116 49, 23 83, 6, 6, 17 6, 20 20 12-3 2 102 AZ 41 STS30-02/-04/-0/-07 0 17 83 0 6, 20 20 12 2-3 102 AZ 41 STS30-01/-03/-06/-08 116 17, 23 133 Approvals H C D AZ 41-➀zpk N Replace Description ➀ S1: A S2: 02/11 2 NC 1 NO/1 NC 02/02 2 NC 2 NC 02/20 2 NC 2 NO 11/11 1 NO/1 NC 1 NO/1 NC Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (For variant -0 and -06 incl. mounting plate) Ordering example To order, first choose the desired safety switch and then the door handle system: for example AZ 41-11/11zpk and AZ 41-STS30-01 Accessories see page 14. Mounting inside, Mounting outside, AZ 41-STS30-01 AZ 41-STS30-02 AZ 41-STS30-03 AZ 41-STS30-04 AZ 41-STS30-0 AZ 41-STS30-06 AZ 41-STS30-07 AZ 41-STS30-08 The drawings are always shown with a view to the switch. 8

Safety door-handle system with solenoid interlock AZM 161 88 max. 100 60 max. 100 93 Thermoplastic enclosure 6 contacts Manual release, emergency exit or emergency release Long life Double insulated X High holding force 2,000 N Power to lock / Spring to lock Cage clamps or screws terminals 4 cable entries M16 x 1. AS-Interface Safety at Work available Shearing force 1,000 N Door handle latching Lockout tag against unintentional locking available Centring device available Technical data Standards: IEC/EN 60947--1 EN 1088 BG-GS-ET-19 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing Actuator and latching bolt: stainless steel 1.4301 Protection class: IP 67 to EN 6029 Contact material: silver Contact type: changeover with double break Zb, galvanically separated contact bridges Switching system: A IEC 60947--1 slow action, NC contact with positive break Termination: screw terminals or cage clamps Cable size: max. 1. mm 2 (incl. conductor ferrules) Cable entry: 4x M 16 x 1. U imp : 4 kv U i : 20 V I the : 10 A Utilisation category: AC-1, DC-13 I e /U e : 4 A / 230 VAC 2. A / 24 VDC Max. fuse rating: 6 A gl/gg D fuse Positive break travel: 9. mm Positive break force: 10 N for each NC contact fitted U s : 24 VAC/DC 110/230 VAC, 0/60Hz Solenoid: 100% ED Power consumption: max. 10 W Ambient temperature: 2 C + 60 ºC Mechanical life: > 1 million operations F max : 2,000 N Latching force: 30 N AZM 161-STS30-99, 116 17 21 23 17 6, 100 6, 20 12-3 0 2 102 20 20 2 102 6, 0 12-3 100 6, 17 AZM 161 STS30-02/-04/-0/-07 23 21 2 AZM 161 STS30-01/-03/-06/-08 116 9, Approvals H C D AZM 161 ➀-12/12rk➁-➂-➃ N Replace Description ➀ SK Screw terminals CC Cage clamps ST Connector M 12 x 1 (wiring, see Main Catalogue) ➁ Spring to lock a Power to lock ➂ Manual release T Emergency exit N Emergency release ➃ 024 U s 24 VAC/DC 110/230 U s 110 / 230 VAC Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (For variant -0 and -06 incl. mounting plate) Ordering example To order, first choose the desired solenoid interlock and then the door handle system: for example AZM SK-12/12rk-T-024 and AZM 161-STS30-01 Accessories see page 14. Mounting inside, AZM 161-STS30-01 AZM 161-STS30-02 AZM 161-STS30-03 AZM 161-STS30-04 Mounting outside, AZM 161-STS30-0* AZM 161-STS30-06* AZM 161-STS30-07 AZM 161-STS30-08 (* Only power to lock) The drawings are always shown with a view to the switch. 9

Safety door-handle system with solenoid interlock AZM 41 Technical data AZM 41-STS30-88 max. 100 60 max. 100 93 A: Adjusting screw ball latch 0-00 N Metal enclosure Two switches in one enclosure Robust design Long life High holding force 3,00 N Adjustable ball latch to 00 N Various manual and emergency releases available Spring to lock / Power to lock 2 cable entries M20 x 1. EEx version available Shearing force 30,000 N Door handle latching Lockout tag against unintentional locking available Centring device available Standards: IEC/EN 60947--1 EN 1088 BG-GS-ET-19 Enclosure: light-alloy diecast, paint finish Actuator: brass, blue chromed-plated Protection class: IP 4 or IP 67 to EN 6029 Contact material: silver Contact type: changeover with double break Zb or 2 NC contacts, galvanically separated contact bridges Switching system: A IEC 60947--1 slow action, NC contact with positive break Termination: screw terminals Cable size: max. 2. mm 2 (incl. conductor ferrules) Cable entry: 2 x M20 x 1. U imp : 4 kv U i : 20 V I the : 6 A Utilisation category: AC-1 I e /U e : 4 A / 230 VAC Max. fuse rating: 6 A (slow blow) Positive break travel: mm Positive break force: min. 1 N (depending on the setting of the ball latch) Solenoid: 100% ED U s : 12 VDC 24 VAC/DC 110 VAC, 0/60 Hz 230 VAC, 0/60 Hz Power consumption: max. 10 W Ambient temperature: 2 C + 0 ºC Mechanical life: > 1 million operations F max : 3,00 N Holding force of the integrated ball latch: 0-00 N (adjustable) 217 172 116 6, 23 6, 129 6, 17 129 0 6, 17, 20 20 10 2-3 102 AZM 41 STS30-01/-03/-06/-08 6, 20 20 10-3 2 102 AZM 41 STS30-02/-04/-0/-07 0 17 116 23 133 Approvals H C D AZM 41 -zpk➀-➁ N Replace Description ➀ ➁ 10 Spring to lock a Power to lock Without manual release E Manual release: with triangular key F With triangular key (sealing screw) RS Cylinder lock with key T Emergency exit NS Emergency release TE Emergency exit inside + manual release outside, interlock mounting outside TEI As above, interlock mounting inside Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (For variant -0 and -06 incl. mounting plate) Ordering example To order, first choose the desired solenoid interlock and then the door handle system: for example AZM 41-zpk-TEI and AZM 41-STS30-01 Accessories see page 14. Mounting inside, Mounting outside, AZM 41-STS30-01 AZM 41-STS30-02 AZM 41-STS30-03 AZM 41-STS30-04 AZM 41-STS30-0* AZM 41-STS30-06* AZM 41-STS30-07 AZM 41-STS30-08 (* Only version TE) The drawings are always shown with a view to the switch.

Safety door-handle system with solenoid interlock AZM 41-xpkE AZM 41-xpkNS AZM 41-zpkTE 2,6 2,6 12, 18 ø20 7 24 11,2 ø20 2,2,2 100 42 130 46, Manual release Release by means of M triangular key M triangular key available as accessory For maintenance, setting-up, etc. Only used on units with spring to lock Emergency release Emergency release is used where an inadvertently locked-in person must leave a dangerous, already interlocked area Release by pressing in the lock button Resetting can only be carried out by authorised personnel using key In released condition, the guard device is protected against unintentional closing Manual release Release and resetting using M triangular key Emergency exit by pushing the red latched button Resetting by pulling on the red latched button In released condition, the guard device is protected against unintentional closing Interlock mounting outside AZM 41-zpkF AZM 41-xpkT AZM 41-zpkTEI 21 27 10 2,6 18 12, 24 19 26,2,2 100 42 130 46, Manual release Release by means of M triangular key After removing the sealing screws, manual release can be carried out using an M triangular key M triangular key available as accessory A chain secures the sealing screw against loss Only used on units with spring to lock Emergency exit Emergency exit is used where an inadvertently locked-in person must leave a dangerous, already interlocked area Emergency exit by pushing the red latched button Resetting by pressing in the latching pin In released condition, the guard device is protected against unintentional closing Manual release Release and resetting using M triangular key Emergency exit by pushing the red latched button Resetting by pulling on the red latched button In released condition, the guard device is protected against unintentional closing Interlock mounting inside AZM 41-xpkRS 2,6 The IP protection class depends on the type of release and is indicated by an x or z in the ordering suffix. ø20 30,2 Protection class IP 4 for example Protection class IP 67 for example AZM 41-xpkNS AZM 41-zpkF Manual release Release by means of cylinder lock Resetting can only be carried out by authorized personnel using key Only used on units with spring to lock In released condition, the guard device is protected against unintentional closing 11

Safety door-handle system with coded ICS safety sensor ICS 9 max. 100 120 Metal enclosure with individually coded ICS safety sensor Operation without physical contact Control category 4 Actuator ICS-B30 incl. mounting plate for easy mounting Axial offset of ± 3 mm possible Connector ST1 Shearing force 67,000 N Door handle is latching in closed condition Lockout tag against unintentional locking available Centring device available Technical data Standards: IEC/EN 60947--3 PDF/M Control category: 4 to EN 94-1 Enclosure: metal capsulated Protection class: IP 67 to EN 6029 Protection class: II to IEC 60947-1 Termination: connector, 6 poles, M 23 x 1 (Conninvers RC) Operating principle: transponder Switching distance, hysteresis: 13 ± mm, < 1% Switching status indication: LED, 2 x identification (green); 1 x fault (red) Input voltage U L1,L2 : 12... 24... 30 VDC, cyclic: pulse: 1... ms; pause: 1... ms Output voltage U A1,A2 : U L1,L2 V < U A1,A2 < U L1,L2 1 V Output current: < 400 ma for each output Outputs: 2 semi-conductor outputs, PNP Response time: > 10 ms, typ. 18 ms Switch-off time: > 7 ms, typ. 100 ms Max. cable length: 300 m Operating voltage U L+ : 1... 24... 30 VDC Operating current I e : < 90 ma Ambient temperature: 30 C + 60 C Shock resistance: 30 g / 11 ms Resistance to vibrations: 10... Hz, Amplitude 1 mm ICS 4 ST1-B30-3 189 13 14, 132 112 90 47 10 12 60, 13 + 6, ICS 4 ST1-B30-0/-07 17 ICS 4 ST1-B30-06/-08 9 9 17 60, 10 12 13 + 90 112 132 14, 47 189 13 3 6, Approvals H C D ICS 4 see on the right Included in delivery ICS safety sensor Mounting plate for safety switch Actuator incl. mounting plate Emergency handle incl. mounting plate Ordering example To order, simply choose the desired safety sensor including the door handle system: for example ICS 4 ST1-B30-0 Mounting outside, ICS 4 ST1-B30-0 ICS 4 ST1-B30-06 ICS 4 ST1-B30-07 ICS 4 ST1-B30-08 The drawings are always shown with a view to the switch. Accessories see page 14. 12

Safety door-handle system with coded safety sensor Operating principle The ICS safety sensor in combination with its individually coded ICS-B30 actuator is based on the identification principle. The machine can only start when the ICS-B30 actuator is in locked position. Two self-monitoring channels monitor the safety code in the safety sensor. Each channel has an output with two output transistors. This output monitoring detects short-circuits between the output and the supply and prevents the machine start-up. Earth faults and low voltage of an output cause the two outputs to be switched-off. The safety control module typically is a safety PLC or a guard door monitor. Generally, these devices provide the power supply for the safety sensor and its two outputs. The output supply emits cyclic signals for cable breakage or cross-wire monitoring. Function The enabling signal for the safety circuit is active for as long as the ICS-B30 actuator is inserted and in locked position in the ICS safety sensor. In this situation, the two LED's (CH1 + CH2) of the ICS safety sensor are green. The hysteresis range is signalled by a red flashing LED (ERR) (the outputs remain enabled and show the typical hysteresis behaviour). When leaving the hysteresis range, the green LED s extinguish and the red LED lights. Wiring example Transponder Actuator Safety sensor Reader Monitoring channel 1 (Ch1) Monitoring channel 2 (Ch2) End level 1 End level 2 This diagram shows the mounting of the ICS with its dual-channel structure L+ L1 A1 L2 A2 L The LED indications signal the ICS status (actuated/not actuated) and possible fault situations. Below, a few possibilities are shown: LED LED CH1 LED ERR LED CH2 Situation LED CH1 LED CH2 LED ERR (green) (green) (red) Normal operation Sensor actuated ON ON OFF Sensor not actuated OFF OFF ON Hysteresis range ON ON flashes Fault situations Malfunction CH1 OFF ON ON Malfunction CH2 ON OFF ON Short-circuit CH1* flashes flashes ON Short-circuit CH2* flashes flashes ON * For supply voltage (L+ or L-) 13

Safety door-handle system Accessories Accessories 78, 0 2 1 97 1, 10 46, 6 0 6, 20 48, 18 116 16 M 34 Lockout tag SZ 41-1/-2 Mounting plate MP TG-01 1 1 6 4 3 2 26 Centring device TFA Euroconnector ISC 4 ST1 Centring device TFI ICS-Cover Accessories general Lockout tag for STS30-01/-03/-06/-08 SZ 41-1 for STS30-02/-04/-0/-07 SZ 41-2 Centring device: Mounting outside TFA-010 Mounting inside TFI-010 Centring device only for AZ 16-STS30 and AZM 161-STS30 : Mounting outside TFA-020 Mounting inside TFI-020 (Dimensions see page 1) Accessories only for AZ and AZM Mounting plate MP TG-01 Accessories only for ICS Euroconnector M23, 6 poles Cover for connector ICS 4 ST1 ICS-Cover 14

Centring device TF. TFA 2 0 Mounting outside Self-centring of the guard door End stop Suitable for all types of actuators Actuator can be easily inserted or extracted 10 4 73 20 6, 40 10 TFI Mounting inside Self-centring of the guard door End stop Suitable for all types of actuators Actuator can be easily inserted or extracted 1

K.A. Schmersal GmbH Safety control systems Möddinghofe 30 D-479 Wuppertal Germany Phone +49 - (0)2 02-64 74-0 Fax +49 - (0)2 02-64 74-1 00 E-Mail info@schmersal.de Internet http://www.schmersal.com x.000/l.d./10.2004/teile-nr. 117742/Ausgabe 02