TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

Similar documents
TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

ZHA/ZHB SERIES WARNING

TCA SERIES CAUTION. Service Literature TCA090/150 SERIES. 7.5 to 12.5 ton 26.3 kw to 44 kw. Table of Contents

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C

Packaged L Series LCA/LGA/LHA

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Landmark Rooftop Units 50 HZ

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

Z-Series Rooftop Units 60 HZ

CHP

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw

Z-Series Rooftop Units 60 HZ

K-Series Rooftop Units 60 HZ

Packaged L Series LCA/LGA/LHA

Packaged L Series LCA/LCC GUK

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

T CLASS ROOFTOP UNITS 60 HZ

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

FEATURES AND BENEFITS

PACKAGE AIR CONDITIONERS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Landmark Rooftop Units 50 HZ

PCB COMMERCIAL SERIES

Landmark Rooftop Units 50 HZ

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

K-Series Rooftop Units 50 HZ

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

Z-Series Rooftop Units 50 HZ

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PHR5. Product Specifications

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

ELITE SERIES R-410A Ready - Multi-Position

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

VHIA High-Static Ducted Indoor Units - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Z-Series Rooftop Units 60 HZ

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

D M S 760 C01 A A 1 1

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

K-Series Rooftop Units 60 HZ

13 GCS X A X Nominal SEER Minor Revision Number

PHB SERIES 7-1/2 and 10 TON

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

DCH Commercial Contents Standard Features Cabinet Features

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

SERIES GCS PACKAGED UNITS COOLING & GAS HEAT

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS

Landmark Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

TECHNICAL SPECIFICATIONS

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

Landmark Rooftop Units 50 HZ

Tons BTU/h S.E.E.R* E.E.R** HSPF

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013)

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Transcription:

TCA ROOFTOP UNITS Service Literature TCA 180 210 240 300 (10 08) The TCA180S, 180H, 210S, 210H, 240S, 240H and 300S are available in one cabinet size with cooling capacities from 180,000 to 286,000 Btuh (45.7 to 83.8 kw). TCA 15 through 25 ton Optional electric heat is field installed in TCA units. Electric heat operates in single or multiple stages depending on the kw input size. 15kW to 60 kw heat sections are available for the TCA180S, 180H and 15 kw to 90 kw heat sections are available for the TCA210S, 240S, 210H, 240H and 300S. TCA180, 210S and 240S units utilize three compressors and TCA210H, 240H and 300S units utilize four. All units are designed to accept any of several different energy management thermostat control systems with minimum field wiring. Information contained in this manual is intended for use by qualified service technicians only. All specifications are subject to change. Procedures outlined in this manual are presented as a recommendation only and do not supersede or replace local or state codes. If the unit must be lifted for service, rig unit by attaching four cables to the holes located in the unit base rail (two holes at each corner). Refer to the installation instructions for the proper rigging technique. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional installer or service agency. WARNING Electric shock hazard. Can cause injury or death. Before attempting to perform any service or maintenance, turn the electrical power to unit OFF at disconnect switch(es). Unit may have multiple power supplies. ELECTROSTATIC DISCHARGE (ESD) Precautions and Procedures CAUTION Electrostatic discharge can affect electronic components. Take precautions during unit installation and service to protect the unit s electronic controls. Precautions will help to avoid control exposure to electrostatic discharge by putting the unit, the control and the technician at the same electrostatic potential. Neutralize electrostatic charge by touching hand and all tools on an unpainted unit surface before performing any service procedure. Table of Contents Specifations.................... Page 2 Blower Data.................... Page 4 Electric Heat Capacities.......... Page 10 Electric Heat / Electrical Data..... Page 10 Options / Accessories........... Page 17 Parts Arrangment............... Page 19 I Unit Components.............. Page 20 II Placement and Installation...... Page 33 III Start Up..................... Page 33 IV Charging.................... Page 34 V System Service Checks........ Page 35 VI Maintenance................. Page 35 VII Accessories................. Page 37 VIII Diagrams................... Page 43 Page 1 2008 Allied Air Enterprises Inc., a Lennox International Inc. Company Phone: (803) 738 4000

SPECIFICATIONS General Data 15 17.5 TON Nominal Tonnage 15 Ton 17.5 Ton Model No. TCA180S2B TCA180H2B TCA210S2B TCA210H2B Efficiency Type Standard High Standard High Cooling Gross Cooling Capacity Btuh (kw) 186,000 (54.5) 186,000 (54.5) 218,000 (63.8) 219,000 (64.1) Performance 1 Net Cooling Capacity Btuh (kw) 180,000 (52.7) 180,000 (52.7) 210,000 (61.5) 210,000 (61.5) ARI Rated Air Flow cfm (L/s) 6000 (2830) 6000 (2830) 6700 (3160) 7000 (3305) Total Unit Power kw 18.6 16.7 21.6 19.4 1 EER (Btuh/Watt) 9.7 10.8 9.7 10.8 2 Integrated Part Load Value (Btuh/Watt) 10.1 11.2 10.1 11.2 Refrigerant Type R 22 R 22 R 22 R 22 Refrigerant Charge Furnished Circuit 1 9 lbs. 0 oz. (4.08 kg) 11 lbs. 8 oz. (5.22 kg) Circuit 2 9 lbs. 0 oz. (4.08 kg) 11 lbs. 8 oz. (5.22 kg) Circuit 3 9 lbs. 0 oz. (4.08 kg) 11 lbs. 8 oz. (5.22 kg) 8 lbs. 0 oz. (3.63 kg) 11 lbs. 0 oz. (4.99 kg) 8 lbs. 0 oz. (3.63 kg) 11 lbs. 0 oz. (4.99 kg) 8 lbs. 0 oz. (3.63 kg) 11 lbs. 0 oz. (4.99 kg) Circuit 4 11 lbs. 0 oz. (4.99 kg) Electric Heat Available 15, 30, 45 or 60 kw 15, 30, 45, 60 or 90 kw Compressor Type (no.) Scroll (3) Scroll (3) Scroll (3) Scroll (4) Outdoor Coils Outdoor Coil Fans Indoor Coils 3, 4 Indoor Blower and Drive Selection Net face area sq. ft. (m 2 ) total 56.0 (5.2) 56.0 (5.2) 56.0 (5.2) 56.0 (5.2) Tube diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Number of rows 1 2 1 2 Fins per inch (m) 20 (787) 20 (787) 20 (787) 20 (787) Motor horsepower (W) (4) 1/3 (249) (4) 1/3 (249) (4) 1/2 (373) (4) 1/3 (249) Motor rpm 1075 1075 1075 1075 Total Motor watts 1370 1395 1800 1395 Diameter in. (mm) No. of blades (4) 24 (610) 3 (4) 24 (610) 3 (4) 24 (610) 3 (4) 24 (610) 3 Total Air volume cfm (L/s) 15,850 (7480) 15,450 (7290) 16,000 (7550) 15,450 (7290) Net face area sq. ft. (m 2 ) total 22.3 (2.07) 22.3 (2.07) 22.3 (2.07) 22.3 (2.07) Tube diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) No. of rows 3 3 3 4 Fins per inch (m) 14 (551) 14 (551) 14 (551) 14 (551) Drain connection number and size (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head Nominal motor HP Low Static 3 hp (2.2 kw) 3 hp (2.2 kw) 5 hp (3.7 kw) 5 hp (3.7 kw) Standard Static 3 hp (2.2 kw) 3 hp (2.2 kw) 5 hp (3.7 kw) 5 hp (3.7 kw) High Static 5 hp (3.7 kw) 5 hp (3.7 kw) 7.5 hp (5.6 kw) 7.5 hp (5.6 kw) Max. usable motor Low Static 3.45 hp (2.6 kw) 3.45 hp (2.6 kw) 5.75 hp (4.3 kw) 5.75 hp (4.3 kw) output (US Only) Standard Static 3.45 hp (2.6 kw) 3.45 hp (2.6 kw) 5.75 hp (4.3 kw) 5.75 hp (4.3 kw) High Static 5.75 hp (4.3 kw) 5.75 hp (4.3 kw) 8.63 hp (6.4 kw) 8.63 hp (6.4 kw) Drive Kit Low Static #A 535 725 rpm #A 535 725 rpm #2 685 865 rpm #2 685 865 rpm Standard Static #1 710 965 rpm #1 710 965 rpm #3 850 1045 rpm #3 850 1045 rpm High Static #4 945 1185 rpm #4 945 1185 rpm #6 1045 1285 rpm #6 1045 1285 rpm Field Installed Standard to #A 535 725 rpm #A 535 725 rpm #2 685 865 rpm #2 685 865 rpm Drive Kits Low Static High to Standard Static #3 850 1045 rpm #3 850 1045 #7 850 1045 rpm #7 850 1045 rpm rpm Blower wheel nominal diameter x width (2) 15 x 15 in. (381 x 381 mm) Filters Type of filter Disposable, pleated MERV 7 No. and size in. (mm) (6) 24 x 24 x 2 (610 x 610 x 51) Electrical characteristics 208/230V, 460V or 575V 60 hertz 3 phase NOTE Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95 F (35 C) outdoor air temperature and 80 F (27 C) db/67 F (19 C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80 F (27 C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. 4 Stocked models are available with standard static drives. High static drives are factory installed (configure to order). Low static drive can be factory installed (configure to order) or standard static drives can be converted to low static with field installed kit. High static models can be converted to standard static with field installed kit. Page 2

SPECIFICATIONS General Data Cooling Performance 20 25 TON Nominal Tonnage 20 Ton 25 Ton Model No. TCA240S2B TCA240H2B TCA300S2B Efficiency Type Standard High Standard 243,000 (71.2) 251,000 (73.5) 302,000 (88.4) Gross Cooling Capacity Btuh (kw) Net Cooling Capacity Btuh (kw) 234,000 (68.5) 240,000 (70.3) 286,000 (83.7) ARI Rated Air Flow cfm (L/s) 8000 (3775) 7500 (3540) 9000 (4245) Total Unit Power kw 24.1 22.2 30.1 1 EER (Btuh/Watt) 9.7 10.8 9.5 3 Integrated Part Load Value (Btuh/Watt) 10.1 11.2 9.7 Refrigerant Type R 22 R 22 R 22 Refrigerant Circuit 1 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 0 oz. (4.99 kg) Charge Furnished Circuit 2 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 0 oz. (4.99 kg) Circuit 3 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 0 oz. (4.99 kg) Circuit 4 11 lbs. 8 oz. (5.22 kg) 11 lbs. 0 oz. (4.99 kg) Compressor Type (no.) Scroll (3) Scroll (4) Scroll (4) Electric Heat Available See page 18 for capacities 15, 30, 45, 60 or 90 kw Outdoor Net face area sq. ft. (m 2 ) total 56.0 (5.2) 56.0 (5.2) 56.0 (5.2) Coils Tube diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Number of rows 2 2 2 Fins per inch (m) 20 (787) 20 (787) 20 (787) Outdoor Motor horsepower (W) (4) 1/3 (249) (4) 1/3 (249) (4) 1/2 (373) Coil Fans Motor rpm 1075 1075 1075 Total Motor watts 1395 1395 1800 Diameter in. (mm) No. of blades (4) 24 (610) 3 (4) 24 (610) 3 (4) 24 (610) 3 Indoor Coils 4, 5 Indoor Blower and Drive Selection Total Air volume cfm (L/s) 15,450 (7290) 15,450 (7290) 16,000 (7550) Net face area sq. ft. (m 2 ) total 22.3 (2.07) 22.3 (2.07) 22.3 (2.07) Tube diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) No. of rows 3 4 4 Fins per inch (m) 14 (551) 14 (551) 14 (551) Drain connection number & size (1) 1 in. NPT coupling (1) 1 in. NPT coupling (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head Nominal motor HP Low Static 5 hp (3.7 kw) 5 hp (3.7 kw) 7.5 hp (5.6 kw) Standard Static 7.5 hp (5.6 kw) 7.5 hp (5.6 kw) 10 hp (7.5 kw) Max. usable motor output (US Only) High Static 10 hp (7.5 kw) 10 hp (7.5 kw) N/A Low Static 5.75 hp (4.3 kw) 5.75 hp (4.3 kw) 8.63 hp (6.4 kw) Standard Static 8.63 hp (6.4 kw) 8.63 hp (6.4 kw) 11.5 hp (8.6 kw) High Static 11.5 hp (8.6 kw) 11.5 hp (8.6 kw) N/A Drive Kit Low Static #2 685 865 rpm #2 685 865 rpm #7 850 1045 rpm Standard Static #7 850 1045 rpm #7 850 1045 rpm #6 1045 1285 rpm High Static #6 1045 1285 rpm #6 1045 1285 rpm N/A Field Installed Low Static Drive Kit #9 685 865 rpm #9 685 865 rpm #7 850 1045 rpm Blower wheel nominal diameter x width (2) 15 x 15 in. (381 x 381 mm) Filters Type of filter Disposable, pleated MERV 7 No. and size in. (mm) (6) 24 x 24 x 2 (610 x 610 x 51) Electrical characteristics 208/230V, 460V or 575V 60 hertz 3 phase NOTE Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95 F (35 C) outdoor air temperature and 80 F (27 C) db/67 F (19 C) wb entering evaporator air; minimum external duct static pressure. 2 Tested at conditions included in with ARI Standard 340/360; 95 F (35 C) outdoor air temperature and 80 F (27 C) db/67 F (19 C) wb entering evaporator air; minimum external duct static pressure. 3 Integrated Part Load Value tested at 80 F (27 C) outdoor air temperature. 4 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. 5 Stocked models are available with standard static drives. High static drives are factory installed (configure to order). Low static drive can be factory installed (configure to order) or standard static drives can be converted to low static with field installed kit. Page 3

BLOWER DATA BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT WITH WET INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 Any factory installed options air resistance (electric heat, economizer, etc.). See table below 2 Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 17 Then determine from table the blower motor output and drive required. 15 TON 0.40 to 1.50 in. w.g. TCA180 Air External Static (in. w.g.) Volume cfm 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Low Static 3 HP, Drive Kit A Standard Static 3 HP, Drive Kit 1 4800 577 1.13 620 1.31 662 1.48 702 1.66 742 1.83 777 2.01 811 2.18 842 2.36 872 2.54 902 2.72 932 2.89 960 3.07 5000 585 1.25 628 1.43 670 1.60 710 1.78 750 1.95 783 2.13 815 2.30 848 2.50 880 2.70 910 2.88 940 3.05 968 3.23 5500 605 1.45 648 1.65 690 1.85 728 2.05 765 2.25 800 2.45 835 2.65 865 2.85 895 3.05 925 3.25 955 3.45 983 3.65 6000 630 1.75 670 1.95 710 2.15 748 2.38 785 2.60 818 2.83 850 3.05 880 3.25 910 3.45 940 3.68 970 3.90 998 4.13 6500 650 2.05 690 2.28 730 2.50 768 2.75 805 3.00 838 3.23 870 3.45 900 3.70 930 3.95 958 4.18 985 4.40 1013 4.63 7000 675 2.35 715 2.63 755 2.90 790 3.15 825 3.40 858 3.68 890 3.95 920 4.20 950 4.45 978 4.70 1005 4.95 1030 5.18 7200 687 2.55 725 2.81 763 3.06 798 3.33 833 3.60 866 3.86 898 4.11 926 4.36 954 4.61 984 4.90 1013 5.19 1038 5.44 NOTE Bold To operate in this range, unit must be ordered with High Static Drive and drive kit #3 must be ordered separately for field installation. 1.60 to 2.60 in. w.g. TCA180 Air External Static (in. w.g.) Volume cfm 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP High Static 5 HP, Drive Kit 4 Field Furnished Drive 4800 987 3.24 1014 3.42 1041 3.60 1064 3.78 1087 3.95 1112 4.13 1136 4.30 1159 4.50 1181 4.70 1204 4.88 1226 5.06 5000 995 3.40 1020 3.60 1045 3.80 1070 3.98 1095 4.15 1118 4.33 1140 4.50 1163 4.70 1185 4.90 1208 5.10 1230 5.30 5500 1010 3.85 1035 4.05 1060 4.25 1085 4.48 1110 4.70 1133 4.90 1155 5.10 1178 5.30 1200 5.50 1220 5.70 1240 5.90 6000 1025 4.35 1050 4.58 1075 4.80 1098 5.00 1120 5.20 1145 5.43 1170 5.65 1193 5.88 1215 6.10 1235 6.33 1255 6.55 6500 1040 4.85 1065 5.10 1090 5.35 1115 5.60 1140 5.85 1163 6.08 1185 6.30 1205 6.53 1225 6.75 1248 7.00 1270 7.25 7000 1055 5.40 1080 5.68 1105 5.95 1130 6.20 1155 6.45 1178 6.70 1200 6.95 1220 7.20 1240 7.45 1263 7.73 1285 8.00 7200 1063 5.68 1088 5.94 1113 6.19 1136 6.44 1159 6.69 1182 6.96 1204 7.23 1226 7.50 1248 7.77 1269 8.03 1289 8.28 NOTE Bold, italics drive is capable of the values noted but will exceed motor horsepower. AIR RESISTANCE (in. w.g.) Factory or Field Installed Options Air Volume cfm Electric Heat Economizer Horizontal Roof Curb MERV 11 Filter 4800.08.01 5000.08.01 5500.10.02 6000.01.11.02 6500.01.02.13.02 7000.01.04.15.03 7200.01.05.16.03 Page 4

BLOWER DATA BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT WITH WET INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 Any factory installed options air resistance (electric heat, economizer, etc.). See table below 2 Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 17 Then determine from table the blower motor output and drive required. 17.5 TON 0.30 to 1.30 in. w.g. TCA210 Air Volume External Static (in. w.g.) Covered By Drive At Nominal Air With Economizer, Standard Filters And Wet Indoor Coil cfm 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Furnished Low Static 5 HP, Drive Kit 2 Standard Static 5 HP, Drive Kit 3 5600 609 1.51 652 1.71 694 1.91 732 2.12 769 2.33 803 2.53 837 2.73 868 2.93 899 3.13 928 3.33 957 3.53 6000 630 1.75 670 1.95 710 2.15 748 2.38 785 2.60 818 2.83 850 3.05 880 3.25 910 3.45 940 3.68 970 3.90 6500 650 2.05 690 2.28 730 2.50 768 2.75 805 3.00 838 3.23 870 3.45 900 3.70 930 3.95 958 4.18 985 4.40 7000 675 2.35 715 2.63 755 2.90 790 3.15 825 3.40 858 3.68 890 3.95 920 4.20 950 4.45 978 4.70 1005 4.95 7500 700 2.75 738 3.03 775 3.30 810 3.58 845 3.85 878 4.15 910 4.45 938 4.70 965 4.95 993 5.23 1020 5.50 8000 725 3.20 763 3.50 800 3.80 833 4.08 865 4.35 898 4.65 930 4.95 958 5.23 985 5.50 1013 5.80 1040 6.10 8400 746 3.55 783 3.87 819 4.18 853 4.49 886 4.80 916 5.12 946 5.43 974 5.73 1001 6.03 1029 6.35 1056 6.66 NOTE Bold To operate in this range, unit must be ordered with High Static Drive and drive kit #7 must be ordered separately for field installation. 1.40 to 2.50 in. w.g. TCA210 Air Volume External Static (in. w.g.) Covered By Drive At Nominal Air With Economizer, Standard Filters And Wet Indoor Coil cfm 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard Static 5 HP, Drive Kit 3 High Static 7.5 HP, Drive Kit 6 5600 985 3.74 1012 3.95 1037 4.15 1062 4.35 1087 4.58 1112 4.80 1135 5.00 1157 5.20 1180 5.41 1202 5.62 1223 5.83 1244 6.04 6000 998 4.13 1025 4.35 1050 4.58 1075 4.80 1098 5.00 1120 5.20 1145 5.43 1170 5.65 1193 5.88 1215 6.10 1235 6.33 1255 6.55 6500 1013 4.63 1040 4.85 1065 5.10 1090 5.35 1115 5.60 1140 5.85 1163 6.08 1185 6.30 1205 6.53 1225 6.75 1248 7.00 1270 7.25 7000 1030 5.18 1055 5.40 1080 5.68 1105 5.95 1130 6.20 1155 6.45 1178 6.70 1200 6.95 1220 7.20 1240 7.45 1263 7.73 1285 8.00 7500 1048 5.78 1075 6.05 1100 6.33 1125 6.60 1148 6.88 1170 7.15 1193 7.40 1215 7.65 1238 7.95 1260 8.25 1280 8.50 1300 8.75 8000 1065 6.40 1090 6.70 1115 6.98 1140 7.25 1163 7.55 1185 7.85 1208 8.13 1230 8.40 1253 8.70 1275 9.00 1295 9.30 1315 9.60 8400 1081 6.96 1106 7.26 1131 7.58 1156 7.89 1179 8.19 1201 8.49 1224 8.79 1246 9.09 1266 9.38 1286 9.67 1307 9.98 1328 10.29 NOTE Bold, italics drive is capable of the values noted but will exceed motor horsepower. Italics field furnished drive AIR RESISTANCE (in. w.g.) Factory Installed Options Air Volume cfm Electric Heat Economizer Horizontal Roof Curb MERV 11 Filter 5600.10.02 6000.01.11.02 6500.01.02.13.02 7000.01.04.15.03 7500.01.06.17.03 8000.02.09.19.04 8400.02.11.21.04 Page 5

BLOWER DATA BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT WITH WET INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 Any factory installed options air resistance (electric heat, economizer, etc.). See table below 2 Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 17 Then determine from table the blower motor output and drive required. 20 TON 0.30 to 1.30 in. w.g. TCA240 Air Volume External Static (in. w.g.) Covered By Drive At Nominal Air With Economizer, Standard Filters And Wet Indoor Coil cfm 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Low Static 5 HP, Drive Kit 2 Standard Static 7.5 HP, Drive Kit 7 6400 648 1.99 688 2.22 727 2.46 764 2.69 801 2.92 834 3.15 866 3.39 896 3.62 926 3.85 954 4.08 981 4.30 7000 675 2.35 715 2.63 755 2.90 790 3.15 825 3.40 858 3.68 890 3.95 920 4.20 950 4.45 978 4.70 1005 4.95 7500 700 2.75 738 3.03 775 3.30 810 3.58 845 3.85 878 4.15 910 4.45 938 4.70 965 4.95 993 5.23 1020 5.50 8000 725 3.20 763 3.50 800 3.80 833 4.08 865 4.35 898 4.65 930 4.95 958 5.23 985 5.50 1013 5.80 1040 6.10 8500 750 3.65 788 3.98 825 4.30 858 4.60 890 4.90 920 5.23 950 5.55 978 5.85 1005 6.15 1033 6.48 1060 6.80 9000 780 4.20 815 4.53 850 4.85 880 5.18 910 5.50 940 5.83 970 6.15 998 6.48 1025 6.80 1053 7.15 1080 7.50 9600 811 4.87 845 5.22 879 5.57 910 5.94 941 6.31 970 6.67 999 7.02 1027 7.38 1054 7.74 1079 8.08 1104 8.41 1.40 to 2.50 in. w.g. TCA240 Air Volume External Static (in. w.g.) Covered By Drive At Nominal Air With Economizer, Standard Filters And Wet Indoor Coil cfm 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard Static High Static 10 HP, Drive Kit 6 6400 1008 4.53 1035 4.75 1060 4.98 1085 5.22 1110 5.45 1135 5.68 1157 5.91 1180 6.15 1202 6.40 1225 6.65 1246 6.88 1268 7.11 7000 1030 5.18 1055 5.40 1080 5.68 1105 5.95 1130 6.20 1155 6.45 1178 6.70 1200 6.95 1220 7.20 1240 7.45 1263 7.73 1285 8.00 7500 1048 5.78 1075 6.05 1100 6.33 1125 6.60 1148 6.88 1170 7.15 1193 7.40 1215 7.65 1238 7.95 1260 8.25 1280 8.50 1300 8.75 8000 1065 6.40 1090 6.70 1115 6.98 1140 7.25 1163 7.55 1185 7.85 1208 8.13 1230 8.40 1253 8.70 1275 9.00 1295 9.30 1315 9.60 8500 1085 7.10 1110 7.40 1135 7.73 1160 8.05 1183 8.35 1205 8.65 1228 8.95 1250 9.25 1270 9.55 1290 9.85 1310 10.15 1330 10.45 9000 1105 7.83 1130 8.15 1153 8.45 1175 8.75 1198 9.08 1220 9.40 1243 9.75 1265 10.10 1288 10.45 1310 10.80 1330 11.10 1350 11.40 9600 1129 8.77 1154 9.13 1177 9.46 1199 9.78 1222 10.14 1244 10.50 1267 10.87 1289 11.23 NOTE italics field furnished drive. AIR RESISTANCE (in. w.g.) Factory Installed Options Air Volume cfm Electric Heat Economizer Horizontal Roof Curb MERV 11 Filter 6400.01.02.13.02 7000.01.04.15.03 7500.01.06.17.03 8000.02.09.19.04 8500.02.11.21.04 9000.04.14.24.04 9600.05.16.26.05 Page 6

BLOWER DATA BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT WITH WET INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 Any factory installed options air resistance (electric heat, economizer, etc.). See table below 2 Any field installed accessories air resistance (duct resistance, diffuser, etc.). See page 17 Then determine from table the blower motor output and drive required. 25 TON 0.0 to 1.10 in. w.g. TCA300S Air External Static (in. w.g.) Covered By Drive At Nominal Air Volume With Economizer, Standard Filters And Wet Indoor Coil cfm 0.0 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 RPM BHP RP BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP M Field Furnished Drive Low Static 7.5 HP, Drive Kit 7 Standard Static 8000 725 3.20 763 3.50 800 3.80 833 4.08 865 4.35 898 4.65 930 4.95 958 5.23 985 5.50 1013 5.80 1040 6310 1065 6.40 8500 750 3.65 788 3.98 825 4.30 858 4.60 890 4.90 920 5.23 950 5.55 978 5.85 1005 6.15 1033 6.48 1060 6.80 1085 7.10 9250 790 4.45 825 4.80 860 5.15 893 5.50 925 5.85 955 6.20 985 6.55 1013 6.88 1040 7.20 1065 7.53 1090 7.85 1115 8.20 10000 835 5.40 868 5.78 900 6.15 930 6.50 960 6.85 988 7.23 1015 7.60 1043 7.98 1070 8.35 1095 8.70 1120 9.05 1145 9.43 10750 875 6.40 908 6.83 940 7.25 970 7.65 1000 8.05 1028 8.45 1055 8.85 1080 9.25 1105 9.65 1130 10.05 1155 10.45 1178 10.83 11500 915 7.40 948 7.88 980 8.35 1010 8.80 1040 9.25 1068 9.68 1095 10.10 1118 10.53 1140 10.95 1165 11.40 1190 11.85 1210 12.23 12000 935 7.95 963 8.35 990 8.75 1020 9.23 1050 9.70 1075 10.15 1100 10.60 1125 10.98 1150 11.35 1173 11.80 1195 12.25 NOTE Bold, italics drive is capable of the values noted but will exceed motor horsepower. Bold To operate in this range, unit must be ordered with Standard Static Drive and drive kit #7 must be ordered separately for field installation. 1.20 to 2.20 in. w.g. TCA300S Air External Static (in. w.g.) Covered By Drive At Nominal Air Volume With Economizer, Standard Filters And Wet Indoor Coil cfm 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard Static 10 HP, Drive Kit 6 Field Furnished Drive 8000 1090 6.70 1115 6.98 1140 7.25 1163 7.55 1185 7.85 1208 8.13 1230 8.40 1253 8.70 1275 9.00 1295 9.30 1315 9.60 8500 1110 7.40 1135 7.73 1160 8.05 1183 8.35 1205 8.65 1228 8.95 1250 9.25 1270 9.25 1290 9.85 1310 10.15 1330 10.45 9250 1140 8.55 1163 8.88 1185 9.20 1208 9.53 1230 9.85 1253 10.20 1275 10.55 1295 10.55 1315 11.20 10000 1170 9.80 1193 10.15 1215 10.50 1238 10.88 1260 11.25 1283 11.62 10750 1200 11.20 1222 11.57 11500 1230 12.60 AIR RESISTANCE (in. w.g.) Factory Installed Options Air Volume cfm Electric Heat Economizer Horizontal Roof Curb MERV 11 Filter 8000.02.09.13.04 8500.02.11.15.04 9250.04.15.18.05 10,000.06.19.21.06 10,750.10.23.25.06 11,000.11.25.27.07 Page 7

BLOWER DATA CEILING DIFFUSER AIR RESISTANCE Air Volume cfm L/s 2 Ends Open in. w.g. Pa RTD11 185 1 Side/2 Ends Open in. w.g. Pa Step-Down Diffuser RTD11 275 All Ends & Sides Open 2 Ends Open 1 Side/2 Ends Open in. w.g. Pa in. w.g. Pa in. w.g. Pa All Ends & Sides Open in. w.g. Pa Flush Diffuser FD11 185 in. w.g. Pa FD11 275 5000 2360.51 127.44 109.39 97.27 67 5200 2455.56 139.48 119.42 104.30 75 5400 2550.61 152.52 129.45 112.33 82 5600 2645.66 164.56 139.48 119.36 90 5800 2735.71 177.59 147.51 127.39 97 6000 2830.76 189.63 157.55 137.36 90.31 77.27 67.42 104.29 72 6200 2925.80 199.68 169.59 147.46 114 6400 3020.86 214.72 179.63 157.50 124 6500 3065.42 104.36 90.31 77.34 85 6600 3115.92 229.77 191.67 167.54 134 6800 3210.99 246.83 206.72 174.58 144 7000 3305 1.03 256.87 216.76 189.49 122.41 102.36 90.62 154.40 99 7200 3400 1.09 271.92 229.80 199.66 164 7400 3490 1.15 286.97 241.84 209.70 174 7500 3540.51 127.46 114.41 102.45 112 7600 3585 1.20 301 1.02 254.88 219.74 184 8000 3775.59 147.49 122.43 107.50 124 8500 4010.69 172.58 144.50 124.57 142 9000 4245.79 196.67 167.58 144.66 164 9500 4485.89 221.75 186.65 162.74 184 10,000 4720 1.00 249.84 209.73 182.81 201 10,500 4955 1.10 273.92 229.80 199.89 221 11,000 5190 1.21 301 1.01 251.88 219.96 239 in. w.g. Pa POWER EXHAUST FANS Return Duct Negative Static Pressure Air Volume Exhausted in. w.g. Pa cfm L/s 0 0 8630 4070 0.05 12 8210 3875 0.10 25 7725 3645 0.15 37 7110 3355 0.20 50 6470 3055 0.25 62 5790 2730 0.30 75 5060 2390 0.35 87 4300 2030 0.40 100 3510 1655 0.45 112 2690 1270 0.50 125 1840 870 Page 8

BLOWER DATA CEILING DIFFUSER AIR THROW DATA 1 Effective Throw Range Model Air Volume No. Step-Down Flush cfm L/s ft. m ft. m Diffuser Model RTD11 185 FD11 185 5600 2645 39 49 12 15 28 37 9 11 180 5800 2740 42 51 13 16 29 38 9 12 Models 6000 2830 44 54 13 17 40 50 12 15 6200 2925 45 55 14 17 42 51 13 16 6400 3020 46 55 14 17 53 52 13 16 6600 3115 57 56 14 17 45 56 14 17 Model No. 210, 240, 300S Models Air Volume 1 Effective Throw Range Step-Down Flush cfm L/s ft. m ft. m Diffuser Model RTD11 275 FD11 275 7200 3400 33 38 10 12 26 35 8 11 7400 3490 35 40 11 12 28 37 9 11 7600 3585 36 41 11 13 29 38 9 12 7800 3680 38 43 11 13 40 50 12 15 8000 3775 39 44 12 13 42 51 13 16 8200 3870 41 46 12 14 43 52 13 16 8400 3965 43 49 13 15 44 54 13 17 8600 4060 44 50 13 15 46 57 14 17 8800 4155 47 55 14 17 48 59 15 18 1 Throw is the horizontal or vertical distance an airstream travels on leaving the outlet or diffuser before the maximum velocity is reduced to 50 ft. (15 m) per minute. Four sides open. DRIVE KIT SPECIFICATIONS Blower Motor Outputs RPM Range Nominal hp Maximum hp Nominal kw Maximum kw Drive A Drive 1 Drive 2 Drive 3 Drive 4 Drive 6 Drive 7 Drive 9 3 3.45 2.2 2.6 535 725 710 965 5 5.75 3.7 4.3 685 865 850 1045 945 1185 7.5 8.63 5.6 6.4 1045 1285 850 1045 685 865 10 11.5 7.5 8.6 1045 1285 *Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by manufacturer are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. MANUFACTURER S NUMBERS DRIVE COMPONENTS RPM ADJUSTABLE SHEAVE FIXED SHEAVE BELTS SPLIT BUSHING Drive H.P. Min Max Supplier No. OEM Supplier No. OEM Part No. Supplier OEM Supplier No. OEM No. Part No. No. Part No. Part No. A 2 & 3 535 725 1VP40x7/8 79J0301 BK95 x 1 7/16 80K1601 BX59 59A5001 N/A N/A 1 3 710 965 1VP40x7/8 79J0301 BK72 x 1-7/16 100244 13 BX56 100245 11 N/A N/A 2 3 & 5 685 865 1VP50x1 1/8 P 8 1977 BK100 x 1-7/16 39L1301 BX62 57A7701 N/A N/A High 3 5 850 1045 1VP65x1 1/8 100239 03 BK110H 100788 06 BX66 97J5901 H 1 7/16 49M6201 4 5 945 1185 1VP60x1 1/8 41C1301 BK90H x 1 7/16 100788 04 BX62 57A7701 H 1 7/16 49M6201 5 7.5 945 1185 1VP60x1 3/8 78L5501 BK90H x 1 7/16 100788 04 BX63 97J5501 H 1 7/16 49M6201 6 7.5 1045 1285 1VP65x1 3/8 78M7101 BK90H x 1 7/16 100788 04 BX64 97J5801 H 1 7/16 49M6201 6 10 1045 1285 1VP65x1 3/8 78M7101 1B5V86 78M8301 5VX760 100245 21 B 1 7/16 100246 01 7 7.5 850 1045 1VP65x1 3/8 78M7101 BK110H 100788 06 BX66 97J5901 H 1 7/16 49M6201 8 10 1135 1365 1VP65x1 3/8 78M7101 1B5V80 100240 05 5VX660 100245 20 B 1 7/16 100246 01 Page 9

ELECTRIC HEAT CAPACITIES 15 kw 30 kw 45 kw 60 kw 90 kw Volts Input kw Btuh No. kw Btuh No. kw Btuh No. kw Btuh No. kw Btuh Input Output of Steps Input Output of Steps Input Output of Steps Input Output of Steps Input Output 208 11.3 38,600 1 22.5 76,800 1 33.8 115,300 2 45.0 153,600 2 67.6 230,700 2 220 12.6 43,000 1 25.2 86,000 1 37.8 129,000 2 50.4 172,000 2 75.6 258,000 2 230 13.8 47,100 1 27.5 93,900 1 41.3 141,000 2 55.1 188,000 2 82.7 282,200 2 240 15.0 51,200 1 30.0 102,400 1 45.0 153,600 2 60.0 204,800 2 90.0 307,100 2 440 12.6 43,000 1 25.2 86,000 1 37.8 129,000 2 50.4 172,000 2 75.6 258,000 2 460 13.8 47,100 1 27.5 93,900 1 41.3 141,000 2 55.1 188,000 2 82.7 282,200 2 480 15.0 51,200 1 30.0 102,400 1 45.0 153,600 2 60.0 204,800 2 90.0 307,100 2 550 12.6 43,000 1 25.2 86,000 1 37.8 129,000 2 50.4 172,000 2 75.6 258,000 2 575 13.8 47,100 1 27.5 93,900 1 41.3 141,000 2 55.1 188,000 2 82.7 282,200 2 600 15.0 51,200 1 30.0 102,400 1 45.0 153,600 2 60.0 204,800 2 90.0 307,100 2 ELECTRICAL/ELECTRIC HEAT DATA TCA180S Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 15.6 (46.8) 7.5 (22.5) 6 (18) (3) Locked Rotor Amps each (total) 124 (372) 59.6 (178.8) 49.4 (148.2) Outdoor Fan Motors (4) Power Exhaust Fans (2) Full Load Amps each (total) 2.4 (9.6) 1.3 (5.2) 1.0 (4.0) Locked Rotor Amps each (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 3 5 7.5 3 5 7.5 3 5 7.5 Motor Rated Load Amps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Locked Rotor Amps 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Minimum with power 0 kw 76 82 90 37 40 44 30 32 35 Circuit exhaust Ampacity 15 kw 76 82 90 37 40 44 30 32 35 30 kw 110 118 127 55 58 63 44 47 50 2 Maximum Overcurrent Protection 4 Unit Fuse Block No. of Steps 45 kw 155 163 172 77 81 85 62 65 68 60 kw 164 172 181 82 85 90 66 68 72 without power exhaust 71 77 85 35 38 41 28 30 33 with power 0 kw 90 90 110 40 45 50 35 35 40 exhaust 15 kw 90 90 110 40 45 50 35 35 40 30 kw 110 125 150 60 60 70 45 50 50 45 kw 175 175 175 80 90 90 70 70 70 60 kw 175 175 3 200 90 90 90 70 70 80 without power exhaust 80 90 110 40 40 50 30 35 40 with power exhaust 90A6 35A8 110A8 2 40A8 45A8 50A8 40A8 without power exhaust 80A6 90A6 110A8 2 40A8 50A8 30A10 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC080 1 35A8 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. 40A8 Page 10

ELECTRICAL/ELECTRIC HEAT DATA TCA180H Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 15.4 (46.2) 7.4 (22.2) 5.9 (17.7) (3) Locked Rotor Amps each (total) 124 (372) 59.6 (178.8) 49.4 (148.2) Outdoor Fan Motors (4) Power Exhaust Fans (2) Full Load Amps each (total) 2.4 (9.6) 1.3 (5.2) 1.0 (4.0) Locked Rotor Amps each (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 3 5 7.5 3 5 7.5 3 5 7.5 Motor Rated Load Amps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Locked Rotor Amps 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Minimum with power 0 kw 76 82 89 37 40 43 30 32 35 Circuit exhaust Ampacity 15 kw 76 82 89 37 40 43 30 32 35 30 kw 110 118 127 55 58 63 44 47 50 2 Maximum Overcurrent Protection 4 Unit Fuse Block 45 kw 155 163 172 77 81 85 62 65 68 60 kw 164 172 181 82 85 90 66 68 72 without power exhaust 71 77 84 35 37 41 28 30 33 with power 0 kw 90 90 110 40 45 50 35 35 40 exhaust 15 kw 90 90 110 40 45 50 35 35 40 30 kw 110 125 150 60 60 70 45 50 50 45 kw 175 175 175 80 90 90 70 70 70 60 kw 175 175 3 200 90 90 90 70 70 80 without power exhaust 80 90 110 40 40 50 30 35 40 with power exhaust 90A6 35A8 110A8 2 40A8 45A8 50A8 40A8 without power exhaust 80A6 90A6 110A8 2 40A8 50A8 30A10 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC080 1 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. 35A8 40A8 Page 11

ELECTRICAL/ELECTRIC HEAT DATA TCA210S Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 20.2 (60.6) 9.7 (29.1) 8 (24) (3) Locked Rotor Amps each (total) 156 (468) 75 (225) 54 (162) Outdoor Fan Full Load Amps each (total) 3 (12) 1.5 (6) 1.2 (4.8) Motors (4) Locked Rotor Amps each (total) 6 (24) 3 (12) 2.9 (11.6) Power Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Exhaust Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Fans (2) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Motor 4 Unit Fuse Block 1 Minimum Circuit Ampacity 2 Maximum Overcurrent Protection Horsepower 3 5 7.5 3 5 7.5 3 5 7.5 Rated Load Amps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Locked Rotor Amps 66 105 152 26.8 45.6 66 23.4 36.6 54 with power exhaust 110A8 2 125A8 2 50A8 60A9 without power exhaust 100A6 110A8 2 40A8 45A8 50A8 125A8 2 50A8 40A8 45A8 with power 0 kw 94 100 107 45 48 52 37 39 42 exhaust 15 kw 94 100 107 45 48 52 37 39 42 30 kw 110 118 127 55 58 63 44 47 50 45 kw 155 163 172 77 81 85 62 65 68 60 kw 164 172 181 82 85 90 66 68 72 90 kw 236 244 253 118 122 126 94 97 101 without power exhaust 89 95 102 43 46 49 35 37 40 with power exhaust 0 kw 110 110 125 50 50 60 40 45 50 15 kw 110 110 125 50 50 60 40 45 50 30 kw 110 125 150 60 60 70 45 50 50 45 kw 175 175 175 80 90 90 70 70 70 60 kw 175 175 3 200 90 90 90 70 70 80 90 kw 3 250 3 250 3 300 125 125 150 100 100 110 without power exhaust 100 110 125 50 50 50 40 40 45 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC080 1 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 90 kw N/A T1DISC150 1 T1DISC150 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. Page 12

ELECTRICAL/ELECTRIC HEAT DATA TCA210H Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 14.7 (58.8) 7.1 (28.4) 5.1 (20.4) (4) Locked Rotor Amps each (total) 91 (364) 50 (200) 37 (148) Outdoor Fan Full Load Amps each (total) 2.4 (9.6) 1.3 (5.2) 1.0 (4.0) Motors (4) Locked Rotor Amps each (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Power Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Exhaust Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Fans (2) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 3 5 7.5 3 5 7.5 3 5 7.5 Motor Rated Load Amps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Locked Rotor Amps 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Minimum Circuit Ampacity 2 Maximum Overcurrent Protection 4 Unit Fuse Block with power 0 kw 88 94 102 43 46 49 32 34 37 exhaust 15 kw 88 94 102 43 46 49 32 34 37 30 kw 110 118 127 55 58 63 44 47 50 45 kw 155 163 172 77 81 85 62 65 68 60 kw 164 172 181 82 85 90 66 68 72 90 kw 236 244 253 118 122 126 94 97 101 without power exhaust 83 89 97 41 43 47 30 32 35 with power 0 kw 100 110 125 45 50 60 35 40 45 exhaust 15 kw 100 110 125 45 50 60 35 40 45 30 kw 110 125 150 60 60 70 45 50 50 45 kw 175 175 175 80 90 90 70 70 70 60 kw 175 175 3 200 90 90 90 70 70 80 90 kw 3 250 3 250 3 300 125 125 150 100 100 110 without power exhaust 90 110 110 45 50 50 30 35 40 with power exhaust without power exhaust 100A6 100A6 110A8 2 125A8 2 110A8 2 45A8 45A8 50A8 60A9 50A8 35A8 30A10 40A8 35A8 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC080 1 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 90 kw N/A T1DISC150 1 T1DISC150 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. 45A8 40A8 Page 13

ELECTRICAL/ELECTRIC HEAT DATA TCA240S Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 22.4 (67.2) 10.9 (32.7) 8.3 (24.9) (3) Locked Rotor Amps each (total) 164 (492) 100 (300) 78 (234) Outdoor Fan Motors (4) Power Exhaust Fans (2) Full Load Amps each (total) 2.4 (9.6) 1.3 (5.2) 1 (4) Locked Rotor Amps each (total) 4.7 (18.8) 2.4 (9.6) 7.9 (7.6) Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 5 7.5 10 5 7.5 10 5 7.5 10 Motor Rated Load Amps 16.7 24.2 30.8 7.6 11 14 6.1 9 11 Locked Rotor Amps 105 152 193 45.6 66 84 36.6 54 66 1 Minimum with power 0 kw 104 112 118 51 55 58 40 42 44 Circuit exhaust Ampacity 15 kw 104 112 118 51 55 58 40 42 44 30 kw 117 127 135 58 63 66 47 50 53 2 Maximum Overcurrent Protection 4 Unit Fuse Block 45 kw 163 172 180 81 85 89 65 68 71 60 kw 172 181 189 85 90 93 68 72 74 90 kw 244 253 261 122 126 130 97 101 103 without power exhaust 100 107 114 49 52 55 38 40 42 with power 0 kw 125 125 150 60 60 70 45 50 50 exhaust 15 kw 125 125 150 60 60 70 45 50 50 30 kw 125 150 150 60 70 70 50 50 60 45 kw 175 175 3 200 90 90 90 70 70 80 60 kw 175 3 200 3 200 90 90 100 70 80 80 90 kw 3 250 3 300 3 300 125 150 150 100 110 110 without power exhaust 110 125 125 50 60 60 45 45 50 with power exhaust 125A8 2 60A9 70A8 50A8 150A8 2 45A8 without power exhaust 110A8 125A8 2 60A9 45A8 50A8 50A8 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC150 1 T1DISC080 1 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 T1DISC150 1 90 kw N/A T1DISC150 1 T1DISC150 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. Page 14

ELECTRICAL/ELECTRIC HEAT DATA TCA240H Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 17.3 (69.2) 9 (36) 7.1 (28.4) (4) Locked Rotor Amps each (total) 123 (492) 62 (248) 50 (200) Outdoor Fan Motors (4) Power Exhaust Fans (2) Full Load Amps each (total) 2.4 (9.6) 1.3 (5.2) 1 (4) Locked Rotor Amps each (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 5 7.5 10 5 7.5 10 5 7.5 10 Motor Rated Load Amps 16.7 24.2 30.8 7.6 11 14 6.1 9 11 Locked Rotor Amps 105 152 193 45.6 66 84 36.6 54 66 1 Minimum with power 0 kw 105 113 119 54 58 61 43 46 48 Circuit exhaust Ampacity 15 kw 105 113 119 54 58 61 43 46 48 30 kw 117 127 135 58 63 66 47 50 53 2 Maximum Overcurrent Protection 4 Unit Fuse Block 45 kw 163 172 180 81 85 89 65 68 71 60 kw 172 181 189 85 90 93 68 72 74 90 kw 244 253 261 122 126 130 97 101 103 without power exhaust 100 108 114 52 55 58 41 44 46 with power 0 kw 110 125 150 60 60 70 45 50 50 exhaust 15 kw 110 125 150 60 60 70 45 50 50 30 kw 125 150 150 60 70 70 50 50 60 45 kw 175 175 3 200 90 90 90 70 70 80 60 kw 175 3 200 3 200 90 90 100 70 80 80 90 kw 3 250 3 300 3 300 125 150 150 100 110 110 without power exhaust 110 125 125 60 60 70 45 50 50 with power exhaust 110A8 2 60A9 70A8 50A8 125A8 2 150A8 2 45A8 without power exhaust 110A8 2 125A8 2 60A9 70A8 50A8 45A8 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC150 1 T1DISC080 1 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 T1DISC150 1 90 kw N/A T1DISC150 1 T1DISC150 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. Page 15

ELECTRICAL/ELECTRIC HEAT DATA TCA300 Voltage 60hz 3 phase 208/230V 460V 575V Compressors Rated Load Amps each (total) 18.6 (74.4) 9.6 (38.4) 7.8 (31.2) (4) Locked Rotor Amps each (total) 156 (624) 75 (300) 54 (216) Outdoor Fan Motors (4) Power Exhaust Fans (2) Full Load Amps each (total) 3 (12) 1.5 (6) 1.2 (4.8) Locked Rotor Amps each (total) 6 (24) 3 (12) 2.9 (11.6) Horsepower 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps each (total) 4.8 (9.6) 2.6 (5.2) 2.0 (4.0) Locked Rotor Amps each (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.2) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 5 7.5 10 5 7.5 10 5 7.5 10 Motor Rated Load Amps 16.7 24.2 30.8 7.6 11 14 6.1 9 11 Locked Rotor Amps 105 152 193 45.6 66 84 36.6 54 66 1 Minimum with power 0 kw 113 121 132 57 61 64 47 49 51 Circuit exhaust Ampacity 15 kw 118 126 132 57 61 64 47 49 51 30 kw 118 127 135 58 63 66 47 50 53 2 Maximum Overcurrent Protection 4 Unit Fuse Block 45 kw 163 172 180 81 85 89 65 68 71 60 kw 172 181 189 85 90 93 68 72 74 90 kw 244 253 261 122 126 130 97 101 103 without power exhaust 108 116 127 55 58 61 45 47 49 with power 0 kw 125 150 150 60 70 70 50 50 60 exhaust 15 kw 125 150 150 60 70 70 50 50 60 30 kw 125 150 150 60 70 70 50 50 60 45 kw 175 175 3 200 90 90 90 70 70 80 60 kw 175 3 200 3 200 90 90 100 70 80 80 90 kw 3 250 3 300 3 300 125 150 150 100 110 110 without power exhaust 125 125 150 60 60 70 50 50 60 with power exhaust 150A8 2 70A8 50A8 60A9 125A8 2 60A9 without power exhaust 125A8 2 60A9 70A8 50A8 60A9 150A8 2 Disconnect 0 30 kw T1DISC150 1 T1DISC080 1 T1DISC080 1 45 kw T1DISC150 1 T1DISC250 1 T1DISC080 1 T1DISC150 1 T1DISC080 1 60 kw T1DISC250 1 T1DISC150 1 T1DISC080 1 T1DISC150 1 90 kw N/A T1DISC150 1 T1DISC150 1 4 Electric Heat Control Kit T1EHKT01C 1Y T1EHKT01C 1G T1EHKT01C 1J NOTE Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 Circuit breaker must be field provided. 4 Only used with electric heat. Page 16

OPTIONS / ACCESSORIES COOLING SYSTEM Compressor Crankcase Heater Item 180 210 240 300S 208/230V T1CCHT01CD1Y x x x x 460V T1CCHT01CD1G x x x x 575V T1CCHT01CD1J x x x x Condensate Drain Trap PVC LTACDKP09/36 x x x x Copper LTACDKC09/36 x x x x Corrosion Protection Efficiency Standard High High Pressure Switch T1SNSR11C 1 x x x x Low Ambient Kit T1SNSR12C 1 x x x x ELECTRIC HEAT 15 kw EHA240 7.5 (order 1) and EHA240S 7.5 (order 1) x x x x 30 kw EHA360 15 (order 1) and EHA360S 15 (order 1) x x x x 45 kw EHA360 22.5 (order 2) x x x x 60 kw EHA150 30 (order 2) x x x x 90 kw EHA360 45 (order 2) x x x Electric Heat Control Kit 208/230V 3ph T1EHKT01C 1Y x x x x 460V 3ph T1EHKT01C 1G x x x x 575V 3ph T1EHKT01C 1J x x x x Unit Fuse Blocks See Electric Heat Tables for Ordering Information AIR FILTERS MERV 11 High Efficiency 24 x 24 x 2 order 6 per unit C1FLTR10C 1 x x x x Replaceable Media Filter Kit with Frame 24 x 24 x 2 order 6 per unit C1FLTR30C 1 x x x x BLOWER SUPPLY AIR See Blower Data Tables for Specifications Low Static Motor/Drive Combination Standard Static Motor/Drive Combination (stock unit) High Static Motor/Drive Combination 1 Standard to Low Static Conversion Kit Drive Kit #A C1DRKT044 1 x 1 Standard to Low Static Conversion Kit Drive Kit #2 C1DRKT004 1 x 1 Standard to Low Static Conversion Kit Drive Kit #9 C1DRKT045 1 x 1 Standard to Low Static Conversion Kit Drive Kit #7 C1DRKT042 1 x 2 High to Standard Static Conversion Kit Drive Kit #3 C1DRKT038 1 x 2 High to Standard Static Conversion Kit Drive Kit #7 C1DRKT042 1 x CONTROLS Control Systems See Engineering Handbook x x x x Blower Proving Switch LTABPSK x x x x Dirty Filter Switch LTADFSK x x x x Smoke Detector Supply LTASASDK10/36 x x x x Smoke Detector Return LTARASDK10/30 x x x x NOTE The catalog and part numbers that appear here are for ordering field installed accessories only. Configure to Order (Factory Installed). Factory installed items are special order with extended lead times and must be ordered with the unit. Field Installed or Configure to Order (factory installed). Factory installed items are special order with extended lead times and must be ordered with the unit. X Field Installed. 1 Standard static drive can be converted to low static drive with field installed kit. 2 High static drive can be converted to standard static drive with field installed kit. Page 17

OPTIONS / ACCESSORIES Item 180 210 240 300S Indoor Air Quality (Co 2 ) Sensors CO 2 Sensor Duct Mounting Kit LTIAQSDMK03/36 x x x x Sensor white case CO 2 display LTAIAQSWDK03/36 x x x x Sensor white case no display LTAIAQSWN03/36 x x x x Sensor black case CO 2 display LTAIAQSND03/36 x x x x Sensor black case, no display LTAIAQSDMBN03/36 x x x x Aspiration Box for duct mounting LTIAQABD03/36 x x x x Handheld CO 2 Monitor LTAIAQSHM03/36 x x x x ELECTRICAL Voltage 60 hz 208/230V 3 phase 460V 3 phase 575V 3 phase HACR Circuit Breakers T1HACR*** 1 (***indicate size) x x x x Disconnect Switch See Electric Heat Tables for ordering information x x x x GFI Service Outlets LTAGFIK10/15 x x x x CABINET Coil Guards C1GARD20C 1 x x x x Hail Guards C1GARD10C 1 x x x x Horizontal Return Air Panel Kit C1HRAP10C 1 x x x x Economizer / OUTDOOR AIR Economizer Order Hood Separately T1ECON10C 1 Economizer Controls Differential Enthalpy C1SNSR07AE1 x x x x Single Enthalpy C1SNSR06AE1 Sensible TASEK03/36 x x x x Differential Sensible TASEK03/36 1 x 1 x 1 x 1 x Barometric Relief Down Flow Barometric Relief Dampers Order Hood Separately LAGED18/24 Hood for Down Flow LAGED C1HOOD20C 1 x x x x Horizontal Barometric Relief Dampers Hood Furnished LAGEDH18/24 x x x x Outdoor Air Dampers / Hoods Damper Section (down flow) Automatic Order Hood Separately T1DAMP20C 1 Damper Section (down flow) Manual Order Hood Separately LAOAD18/24 Outdoor Air Hood (down flow) includes 3 16 x 25 x 1 in. filters C1HOOD10C 1 Power Exhaust Standard Static 208/230V C1PWRE20C 1Y x x x x 460V C1PWRE20C 1G x x x x 575V C1PWRE20C 1J x x x x ROOF CURBS Down Flow Cliplock 1000 14 in. (356 mm) height LARMF18/30S 14 x x x x 18 in. (457 mm) height LARMF18/30S 18 x x x x 24 in. (610 mm) height LARMF18/30S 24 x x x x Horizontal Cliplock 1000 26 in. (660 mm) height LARMFH18/24S 26 x x x x 37 in. (940 mm) height LARMFH18/24S 37 x x x x Down Flow Standard 14 in. (356 mm) height LARMF18/36 14 x x x x 24 in. (610 m) height LARMF18/36 24 x x x x Horizontal Standard 26 in. (660 mm) height LARMFH18/24 26 x x x x 37 in. (940 mm) height LARMFH18/24 37 x x x x Insulation Kits for Standard Horizontal Roof Curbs for LARMFH18/24 26 C1INSU11C 1 x x x x for LARMFH18/24 37 C1INSU13C 1 x x x x CEILING DIFFUSERS Step Down Order one RTD11 185(S) x RTD11 275(S) x x x Flush FD11 150/180S or FD11 185 x Order one FD11 275(S) x x x Transitions (Supply and Return) LASRT18(S) x Order one LASRT21/24(S) x x x Field Installed or Configure to Order (factory installed). Factory installed items are special order with extended lead times and must be ordered with the unit. X Field Installed. 1 Order two each Page 18

TCA180/300 PARTS ARRANGEMENT ECONOMIZER DAMPERS (OPTIONAL) FILTERS (SIX 24 X 24 X 2") INDOOR COIL OUTDOOR FANS BLOWERS BLOWER MOTOR FILTER DRIERS CONDENSATE DRAIN OUTDOOR COIL MCC (A45) CONTROL ELECTRIC HEAT (OPTIONAL) COMPRESSORS (4TH COMPRESSOR ON 210H, 240H, & 300H UNITS ONLY) FIGURE 1 TCA CONTROL BOX T1 T18 F10 F6 K10 A45 MCC K65 C2 C1 K3 K1 K2 K14 K146 K138 K68 C19 C18 S42 TB2 GND FIGURE 2 Page 19

I UNIT COMPONENTS TCA unit components are shown in figure 1. All units come standard with removeable unit panels. All L1, L2, and L3 wiring is color coded; L1 is red, L2 is yellow, and L3 is blue. A Control Box Components TCA control box components are shown in figure 2. The control box is located in the compressor compartment. 1 Disconnect Switch S48 (field installed) All units may be equipped with an optional disconnect switch S48, or circuit breaker, CB10. S48 and CB10 can be a toggle switch or a twist style switch. Both types can be used by the service technician to disconnect power to the unit. CB10 when use, will be in the same location as S48 on the wiring diagram. 2 Terminal Strip TB2 All units are shipped with factory installed TB2. Units without S48 or CB10 will have supply power connected to TB2. 3 Control Transformer T1 (all units) All use a single line voltage to 24VAC transformer mounted in the control box. Transformer supplies power to control circuits in the unit. The transformer is rated at 70VA and is protected by a 3.5 amp circuit breaker (CB8) which is located on the transformer itself. The 208/230 (Y) voltage 208/230V TRANSFORMER transformers have two BLUE YELLOW SECONDARY primary voltage taps, but only one may be 208 VOLTS used depending on RED supply voltage. See 230 VOLTS figure 3. 460 (G) and PRIMARY ORANGE BLACK 575 (J) voltage transformers use a single FIGURE 3 primary voltage tap. 4 Contactor Transformer T18 T18 is a single line voltage to 24VAC transformer used in 4 compressor units only. Transformer T18 is protected by a 3.5 amp circuit breaker (CB18) located on the transformer itself. T18 is identical to transformer T1. The transformer supplies 24VAC power to the contactors. 5 Terminal Strip TB1 All indoor thermostat connections will be to TB1 located on MCC board A45. For thermostats with occupied and unoccupied" modes, a factory installed jumper across terminals A1 and A2 should be removed. Unit wiring is designed for a three stage thermostat. For two stage applications jumper between Y2 and Y3 on TB1. 6 Terminal Strip TB14 Terminal strip TB14 located on the MCC board A45 distributes 24V power from transformer T1 to the control box components. Units not equipped with smoke detectors A17 or A64, will have a factory installed jumper across terminals 24VAC and R. 7 Outdoor Fan Capacitors C1, C2, C18 & C19 Fan capacitors C1, C2, C18, C19 are 10 MFD / 370V capacitors used to assist in the start up of condenser fans B4, B5, B21, B22 respectively. 8 Outdoor Fan Relay K10 & K68 Outdoor fan relays K10 and K68 used in all units, are DPDT relays with a 24VAC coil. In all TCA units K10 energizes condenser fans B4 and B5 and K68 energizes condenser fans B21 and B22. 9 Fuses F10 and F6 Two line voltage fuses F10 provide overcurrent protection to all condenser fans in all Y voltage TCA units and rated at 30A. Fuses F6 provide overcurrent protection for optional field installed power exhaust fans and rated at 15A. 10 Compressor Contactor K1, K2 & K14 (all units) K146 (TCA 210H, 240H, 300S units only) All compressor contactors are three-pole-double-break contactors with 24VAC coils. In all TCA180, 210S and 240S units, K1, K2 and K14 energize compressors B1, B2 and B13 in response to thermostat demand. In the TCA210H, 240H and 300S units, K1, K2, K14 and K146 energize compressors B1, B2, B13 and B20 in response to thermostat demand. 11 Blower Contactor K3 Blower contactor K3, used in all units, is a three-pole-doublebreak contactor with a 24VAC coil used to energize the indoor blower motor B3 in response to blower demand. K3 is energized by relay KD on the A45 MCC board. Page 20