MANUAL OPERATED CRYOGENIC GLOBE VALVE

Similar documents
PV-80 Remotely Operated Cryogenic Flow Control Globe Valve Installation, Operation, and Maintenance Manual

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

PHPK Technologies SPECIFICATION

PHPK. Cryogenic Valves TECHNOLOGIES INCORPORATED

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Baumann Series Flexsleev Control Valve Instructions

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

REMOVAL & INSTALLATION

PV-70 Remotely Operated Cryogenic Globe Valve Installation, Operation, and Maintenance Manual

J Flow Controls Model Numbering

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

Baumann Mikroseal Control Valve

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing.

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

Service Manual Air Tech Second Stage

Model DFR 070/156/220 Rotary Actuator

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Pressure Relief Valve Maintenance Manual

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

Hard Seat Fluid Pressure Regulator

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

Baumann Sanitary Diaphragm Angle and Inline Control Valve

ANDERSON GREENWOOD SERIES 9290 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Service Manual Air Plus Second Stage

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

Fisher 657 Diaphragm Actuator Sizes and 87

SY-SERIES S04DA75 THRU S06DA180 & S04SR75 THRU S06SR180 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

Before installation these instructions must be fully read and understood

Model DFR 026 Rotary Actuator

Baumann Little Scotty Bronze Control Valve

Unique 7000 Series Valve - Standard and Reverse Acting

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

Disassembly and Reassembly for CBB-SR (Spring Return) Series Pneumatic Actuators

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

THD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

33 CENTERVILLE ROAD LANCASTER, PA

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Fisher 3024C Diaphragm Actuator

INSPECTION & MAINTENANCE BULLETIN ARI 1301/1302 1" Plug Type Angle Valves

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

Cryogenic Wafer-Sphere Butterfly Valves

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

Globe Control Valve Series 1a

Baumann Way Control Valve

Baumann 24000F Wafer Control Valve

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

CV Control Valves Installation and Operation Manual

Hydraulic Motors Repair Instructions

DA Series Diaphragm Valve

Baumann Pneumatic Actuators

Service Manual. Balanced Piston First Stage

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

0-800 psi Carbide Seat Fluid Pressure Regulator

Installation, Operation, and Maintenance Manual GENERAL VALVE GENERAL VALVE TRUSEAL / IOM-GEN-TRUSEAL. Installation, Operation, and Maintenance Manual

IMOI 2010 Rev 0

Back Pressure Regulator

ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS

0-500 PSI Soft Seat Fluid Pressure Regulator

Anderson Greenwood Series 800 POSRV Installation and Maintenance Instructions

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Soft Seat Fluid Pressure Regulator

OPERATING AND MAINTENANCE MANUAL

Gate Valve Maintenance & Adjustment Procedures

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

Property of American Airlines

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

6 6mm Nylon Lock Nuts 4 12mm Lock Washers 12 6mm Hex Nuts 4 12mm x 32mm x 3mm Flat Washers. (2) 12mm x 40mm Narrow Bolt Plates (Rear)

Packing Replacement Kit for Flowrite VF 599 Series Valves

Blue Jay Rodless Cylinder BC MS. Track Repair Manual 1996 & 2012 THE EASTMAN EASTMAN. All End Caps Black for Models

GATE VALVE MAINTENANCE AND ADJUSTMENT PROCEDURES

Baumann Sanitary Angle Control Valve

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Fisher 585C Series Piston Actuators

ANDERSON GREENWOOD. Before installation these instructions must be fully read and understood.

(2) 10mm x 50mm T-Bolts (For Rear Brackets only) (6) 10mm Rod Bolts. (2) 10mm x 35mm Button Head Bolt Plates

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

Welker Jet Top Entry Control Valve

DL/DS Series Diaphragm Valve

ONYX VALVE CO MODEL CER and CEP Installation & Maintenance

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Fisher 1052 Size 70 Diaphragm Rotary Actuator

Disassembly and Reassembly for CBB (Double Acting) Series Pneumatic Actuators

for ½" thru 2" 800 lb. Piston Lift Check Valves with Resilient Seat Option

Transcription:

INITIAL AND DATE NUMBER 01-81-3007 PREPARED CAR 3-22-96 RELEASE DATE CHECKED JHM 3-22-96 3/22/96 ENGINEER SLH 3-22-96 APPROVED JGP 3-22-96 N/C 1 OF 8 LTR REVISION RELEASE DATE INITIAL AND DATE CHGD CHKD ENGR APPD

N/C 2 OF 8 Operation 1. The operator and valve have been preadjusted to insure bubble-tight shut-off of the valve at the seat to the customer-supplied design pressure rating. No further adjustments should be required. 2. All moving and contacting parts have closely held tolerances for free operation. The seal seat is a replaceable Neoflon PCTFE M-400H (formerly known as Kel-F) for positive shut-off. The bonnet O-Ring seals and the seal seat are the only replaceable wear items. The valve is designed to operate smoothly under all cryogenic conditions. Maintenance 1. With proper care, the Valve Assembly should require very little maintenance; however, as with all cryogenic equipment, thorough inspection of the system should be performed periodically to ensure continued, reliable operation. 2. O-Rings (6, 7) can be replaced by following the installation instructions for removing the actuator, and then by removing the Gland Nut (5) from Valve Stem (2) by turning gland nut counterclockwise and sliding it off the valve stem. Remove O-Rings (6, 7) from gland nut, taking care not to damage O-Rings during removal. Inspect O-Rings for damage such as nicks, scratches or tears. Replace as needed. Clean O-Ring grooves and replace in reverse assembly order after applying a very thin film of Halocarbon 25-5S or Krytox Grease to O-Rings. Bonnet O-Ring (10) can be inspected and replaced using installation instructions. 3. The Neoflon PCTFE M-400H Seal Disc (13) can be replaced by following the installation instructions for removal of the valve bonnet and barrel. To remove the seat seal for replacement simply press thumb against the open slot in the Kel-F seat while holding the barrel rigid. Very slight pressure should snap the seat seal from the barrel. Replace the seat seal and reassemble in reverse order. CAUTION: Assembly contains equipment plated with nickel. Cleaning with acids or other caustic solutions will remove plating and void warranty. Questions Contact: 2111 Builders Place Columbus, OH 43204 TEL (614) 486-4750, FAX (614) 486-4950

N/C 3 OF 8 (Continued) Installation Removal of Actuator 1. Support valve and actuator. 2. Remove actuator by removing Actuator Mounting Jam Nut (4). Loosen Stem Jam Nut (17). Carefully supporting actuator, unscrew Valve Stem (5) counterclockwise completely from actuator stem. At this point the actuator should slide completely off valve by lifting upward vertically. Removal of Barrel and Valve Seat 1. Support Valve 2. Remove Bonnet Bolts (10) and lift bonnet upward vertically until Valve Stem (5) can be removed from slot in Barrel (12). 3. Remove barrel and seat assembly from valve body; Care should be taken not to drop barrel and seat assembly onto valve body as the Neoflon PCTFE M-400H (formerly known as Kel-F) seal seat could be damaged. 4. Remove O-Ring (11) and store in a clean are until ready for reassemble. Installation in Process Line 1. Prepare connection on equipment on which valve will be installed. 2. Position Valve Body (14) to equipment and weld into place. (Weld per customer approved welding procedure). NOTE: All valve bodies are 304L Stainless Steel. Care should be taken not to over-heat valve body beyond that required for normal welding. When the valve is to be installed in a vacuum jacketed system, care should be taken not to introduce welding stress between the vacuum jacket and valve assembly, and to prevent forces on the bonnet of the valve caused by differential contraction rates (thermal loads) between the inner process line and the vacuum jacket.

N/C 4 OF 8 (Continued) Inspection of Weld Joints 1. Dye penetrant or radiograph check process line weld joint per customer approved procedure. 2. Pneumatic or hydrostatic pressure test inner line to specified test pressure per customer approved procedure. If hydrostatic test is used demineralized water is suggested as testing fluid. All traces of testing fluid are to be removed from pipes, valves, flex, etc. prior to proceeding. Re-assembly of Barrel and Seat Assembly 1. Allow valve body to cool after welding, ensure all testing fluids have been removed form valve. 2. Clean O-Ring (11) and O-Ring groove. Apply a very thin film of Halocarbon 25-5S or Krytox Grease to O-Ring and replace in groove. 3. Slide Valve Stem (5) into Barrel Slot (12) and slide assembly down into valve body. Replace Bonnet Bolt (10) and tighten to 150 inch Lbs. of torque. Re-assembly of the Actuator 1. It may be necessary to apply a temporary loading pressure to the actuator to move the actuator stem away from the valve during installation. CAUTION: When placing the actuator with loading pressure applied, use caution to keep hands and tools from between the actuator stem and the valve stem. If loading pressure is disconnected, personal injury may be possible if caught between actuator stem and valve stem. 2. Slowly lower the actuator down on to the valve. As the actuator yoke passes over the Valve Stem (5), place the Actuator Jam Nut (4) over the stem. 3. Continue to lower the actuator while guiding the Valve Stem (5) into the actuator stem (NOTE: At this point, it may be necessary to screw the valve stem into the actuator stem to allow the actuator yoke to seat properly onto the Valve Bonnet (9). If this is done, screw valve stem as far as possible into actuator stem to allow for seat adjustment later on). 4. Screw the Actuator Jam Nut (4) onto the Valve Bonnet (9) and tighten.

N/C 5 OF 8 (Continued) Readjusting Fail Closed Valve 1. Temporarily apply loading pressure to move actuator stem in upward position. 2. Loosen Valve Stem Jam Nut (17) and screw valve stem up into actuator. 3. Remove loading pressure from actuator allowing valve stem to move down into valve. 4. Screw Valve Stem (5) counterclockwise to move stem downward into valve. This should be done until resistance is met. (This should be the valve seat Kel-F coming into contact with the valve seat in the casting). 5. Supply loading pressure once again to the actuator to lift the valve stem upward. 6. Screw the Valve Stem (5) 2 complete rotations counterclockwise adjusting the valve stem downwards, then snug Valve Stem Jam Nut (17). 7. Remove loading pressure from actuator, then actuate actuator 4 to 5 times. 8. Check valve seat sealing by applying pressure to main process line to insure bubble-tight shut-off. At this point, valve should be ready for service. (If valve does not seat bubble-tight continue to next step). 9. Apply loading pressure once again to the actuator to lift the valve stem upwards. 10. Loosen stem jam nut and screw the valve stem (1) complete rotation counterclockwise adjusting the stem downward, then snug stem jam nut and remove loading pressure. 11. Actuate actuator 4 to 5 times and recheck valve bubble-tight shut-off. (This process can be used for a maximum of 3 times). If valve does not shut-off bubble-tight at this point, please contact your nearest PHPK representative.

N/C 6 OF 8 (Continued) Readjusting Fail Open Valve 1. Remove any loading pressure from actuator to allow actuator stem to move in upward position. 2. Loosen Valve Stem Jam Nut (17) and screw valve stem up into actuator. 3. Apply loading pressure to actuator allowing valve stem to move down into valve. 4. Screw Valve Stem (5) counterclockwise to move stem downward into valve. This should be done until resistance is met. (This should be the valve seat Kel-F coming into contact with the valve seat in the casting). 5. Remove loading pressure once again from actuator to lift the valve stem upward. 6. Screw the Valve Stem (5) 2 complete rotations counterclockwise adjusting the valve stem downwards, then snug Valve Stem Jam Nut (17). 7. Apply loading pressure to actuator, then actuate actuator 4 to 5 times. 8. Check valve seat sealing by applying pressure to main process line to insure bubble-tight shut-off. At this point, valve should be ready for service. (If valve does not seat bubble-tight continue to next step). 9. Remove loading pressure once again from actuator to lift the valve stem upwards. 10. Loosen stem jam nut and screw the valve stem (1) complete rotation counterclockwise adjusting the stem downward, then snug stem jam nut and remove loading pressure. 11. Actuate actuator 4 to 5 times and recheck valve bubble-tight shut-off. (This process can be used for a maximum of 3 times). If valve does not shut-off bubble-tight at this point, please contact your nearest PHPK representative.

PHPK PHPK Spare Parts List TECHNOLOGIES INCORPORATED 535 ENTERPRISE DRIVE WESTERVILLE, OHIO 43081 PHONE: (614) 436-9114 FAX: (614) 436-5815 ¼" OD - 1" OD Tube Size Remote Operated Valve Pressure Rating 150 PSI WOG [1]

PHPK PHPK Item No. PHPK Part Number Spare Parts List TECHNOLOGIES INCORPORATED 535 ENTERPRISE DRIVE WESTERVILLE, OHIO 43081 PHONE: (614) 436-9114 FAX: (614) 436-5815 Qty. Rec. ¼" OD - 1" OD Tube Size Remote Operated Valve Pressure Rating 150 PSI WOG [1] Description 1 84-020-010 1 PHPK Tube Size Actuator 2 05-001-001 1 Breather Vent 3 81-530-020 1 Actuator Adapter, Remote 4 81-530-010 1 Jam Nut, Actuator 5 81-410-010 1 Valve Stem, Remote 6 81-390-010 1 Gland Nut 7 11-02-2110 *2 O-Ring 8 11-02-2113 *1 O-Ring 9 81-330-010 1 Bonnet, Remote 10 81-541-020 6 Bonnet Bolt (Niflor coated) 11 11-02-2121 *1 O-Ring 12 81-430-010 1 Barrel Assembly (Niflor coated) 13 81-480-010 *1 Seal Disc Neoflon PCTFE M-400H (2) 14 1 Valve Body 15 FAS-70003 4 Hex Head Cap Screw 16 FAS-71063 4 Lock Washer, Split 17 FAS-70832 1 Jam Nut 81-900-010 1 Valve Soft Goods Spare Parts Kit * These items are recommended spare parts and are available in the kit P/N 81-900-010 (1) Valves individually tested to customer rated pressure, all valves not tested to maximum working pressure. (2) Formally Kel-F 81