Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

Similar documents
GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

"Accredited Test Laboratory" (ATL) means an organisation that is accredited by the South African National Accreditation System (SANAS).

STATUTORY INSTRUMENTS. S.I. No. 732 of 2007 SAFETY, HEALTH AND WELFARE AT WORK (GENERAL APPLICATION) (AMENDMENT) REGULATIONS 2007

CAL/OSHA ELECTRICAL LOW VOLTAGE

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

S.C.C. Syllabus. Note 3 : A candidate qualifying in part 5 need not qualify further in part 12. SYLLABUS FOR SUPERVISORS. Part-1

The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector

In general this document presents specific safety procedures for systems with potentially lethal voltages on bare or exposed conductors.

POTENTIAL HEALTH & SAFETY HAZARDS

The Use of Electricity In Mines Regulations

CHAPTER 40 PROFESSIONAL LICENSING AND FACILITY REGULATION. PART 13 Radiation Safety Requirements for Particle Accelerators

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

Electricity Safety (Electrical Installations) Regulation 2005

CHAPTER II-1 D. Construction subdivision and stability, machinery and electrical installations

PLANNING, DESIGNING & CONSTRUCTING YOUR EXHIBITION

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

CENTRAL ELECTRICITY AUTHORITY (MEASURES RELATING TO SAFETY AND ELECTRIC SUPPLY) REGULATIONS, 2010

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Books. Code of Practice for In-Service Inspection and Testing of Electrical Equipment (3rd edition) By IET Publication

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Number 5 of 2003 MOTOR VEHICLE (DUTIES AND LICENCES) ACT 2003 ARRANGEMENT OF SECTIONS. 4. Amendment of Part I of Schedule to Act of 1952.

Exhibition Manual for Gallagher Convention Centre ( GCC )

Radiation Safety Requirements for the Use of Non-Medical X- Ray.

Energized Electrical Work

ELECTRICAL - GENERAL REQUIREMENTS SELF INSPECTION CHECKLIST

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

part three electrical installations

ELECTRICAL. 60 Minutes

RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS NOT USED IN THE HEALING ARTS

Unified requirements for systems with voltages above 1 kv up to 15 kv

ES5 Security Theory/Regulations Answer Schedule

PART I RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS

ELECTRICITY REGULATIONS 1939

Australian Explosives Industry and Safety Group (AEISG) Code of Practice Mobile Processing Units 4 th edition. Compliance Checklist.

Surface Regulations and Policies

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

SECTION 300 OVERHEAD SERVICE

ELECTRIC DIVISION RULES AND PROCEDURES FOR ELECTRIC SERVICE

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

ESSENTIAL SAFETY RESOURCES

NEC 2011 Code Changes

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

Monitor and Review. Electrical Safety. Causeway Coast and Glens Borough Council HSPD 009

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

PORTABLE ELECTRICAL EQUIPMENT SAFE OPERATING PROCEDURE

PART 10 ELECTRICAL INSTALLATIONS

2014 NEC Changes Part 4

A SHORT GUIDE TO THE OCCUPATIONAL SAFETY AND HEALTH ACT 9, 2006 FOREWORD

Electrical test equipment for use on low voltage electrical systems

Western Plant Health Association Anhydrous Ammonia Facility / Field Tank Safety Self Inspection Safety Checklist Form

BSS Examination Record Form for Privately Owned and Managed Vessels

GENERAL INFORMATION 1.01 PURPOSE

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

Operating Instructions

THE CORPORATION OF THE TOWNSHIP OF MIDDLESEX CENTRE BY-LAW NUMBER

Actsafe Safety Bulletin #23 WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT

Electrical safety and you

AVOIDING ELECTROCUTION HAZARDS

And the Labour Law for the Private Sector promulgated by And Legislative Decree No.(36) of 2012, particularly Article (166) thereof,

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

Generator Fire Safety: Generator assemblies should be located outside the building.

Unrestricted. S.Mukhopadhyay

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

ELECTRICAL GROUNDING SAFETY PROGRAM

Photovoltaic Module User Manual

Powered Industrial Vehicle Policy

TRAFFIC CONTROL REGULATIONS

Number 22 of 2001 MOTOR VEHICLE (DUTIES AND LICENCES) ACT, ARRANGEMENT OF SECTIONS. Section 1. Interpretation.

CHAPTER 10 ELECTRICAL

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

ENGINEERS RESPONSIBILITY-WINDERS

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

FINAL-ER 42 Electrician Regulations Answer Schedule

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Comhairle Chontae Chill Mhantain Wicklow County Council Fire Service.

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

Ch. 167 PORTABLE WARNING DEVICES CHAPTER 167. PORTABLE EMERGENCY WARNING DEVICES

Statutory Instruments Supplement No. Supplement to Official Gazette No. dated, MOTOR OMNIBUS TERMINALS REGULATIONS, Arrangement of Regulations

Operating procedures relating to the use of electrical equipment and installations

Periodic comprehensive review of the CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 (as amended)

18 HB 673/AP A BILL TO BE ENTITLED AN ACT

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

The Impact of the 18 th edition (BS 7671:2018)

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

Technical Information Manual

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Definitions of and have been revised. a. automatic b. nonautomatic c. none of the above d. both a and b

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

Element C8.3 Installation, Use and Inspection of Electrical Systems

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Weights And Measures (Sand And Other Ballast) THE WEIGHTS AND MEASURES ACT (CAP. 340) PART I PRERIMINARY PROVISIONS PART II BALLAST

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

Transcription:

1 Title Chapter 14:08 Factories and Works (Electrical) Regulations, 1976 2 Interpretation of terms 3 Fencing and enclosure 4 Notices 5 Safety precautions 6 Switch-boards 7 Portable electric tools and lights 8 Examination and repairs 9 Safety equipment 10 Temporary earthing and isolation 11 Earthing, general 12 Transformer-or switch-rooms and houses Chapter 14:08 Factories and Works (Electrical) Regulations, 1976 Rhodesia Government Notice No. 304 of 1976 Amended by S.I. 285/82. ARRANGEMENT OF SECTIONS PRELIMINARY Section PART I ELECTRICAL MACHINERY PART II MAINTENANCE PART III INSTALLATION IT is hereby notified that the Minister of Labour and Social Welfare has, in terms of subsection (1) of section 34 of the Factories and Works Act [Chapter 14:08], made the following regulations: PRELIMINARY Title 1 (1) These regulations may be cited as the Factories and Works (Electrical) Regulations, 1976. (2) These regulations shall come into operation on the 1st May, 1976. 2 In these regulations Interpretation of terms "Chief Inspector" means the Chief Inspector of Factories appointed in terms of section 4 of the Act; code means a publication (a) embodying a Code of Practice laid down by the British Standards Association or the Central African Standards Association or the South African Bureau of Standards; and

(b) copies of which are held at Occupational Safety Offices "competent person" means a person who has served an apprenticeship in an appropriate trade or who has not less than 5 years' practical experience in working with machinery, and who has a thorough knowledge of the machinery or class of vessel of which he is in charge or which he may be required to examine; conductor means any bar, pin, tube, socket, wire or line used for conducting electrical energy; earthed and connected with earth means connected with the general mass of earth in such a manner as will ensure at all times an immediate and efficient discharge of electrical energy, and cognate expressions shall be construed accordingly; extra low voltage means normal operating voltage not exceeding 30 volts. inspector means an inspector appointed in terms of section 4 of the Act; insulation means non-conducting material enclosing, surrounding or supporting electrical conductors, or parts of electrical equipment which may become live; live means charged with electrical energy; low voltage means exceeding 30 volts but, not exceeding 250 volts; metal parts or metal work means any metal part other than a conductor and its associated live parts, or an earth conductor; user means an occupier or builder, or the person or persons owning or using the machinery or electrical apparatus. PART I ELECTRICAL MACHINERY Fencing and enclosure 3 A user shall cause all electricity generating plant, transforming, switching or linking apparatus, to be fenced or properly enclosed when situated in any factory or structural works. Notices 4 (1) A user shall cause the following notices to be exhibited at suitable places within electric generating stations and all premises and structural sites where electrical apparatus is installed (a) a notice prohibiting any unauthorized person from handing or interfering with electrical apparatus; (b) a notice containing directions as to procedure in case of fire; (c) a notice containing directions as to resuscitation of persons suffering from the effects of electric shock; (d) a notice forbidding interference with switches whilst any person is working on associated electrical apparatus during maintenance, repair or similar operations. (2) Notices prohibiting unauthorized persons from entering such factories or structural premises shall be posted at all designated entrances to such premises. Safety precautions 5 A user shall cause all electrical machinery, apparatus and conductors to be so installed, worked, maintained and identified as to prevent danger to persons and to be protected in such a manner that no injuries can be caused to any person by inadvertent contact with any portion thereof. Switch-boards 6 A user shall cause all switch-boards to have at the back thereof a clear space of at least 1,2 mtrs, and this space shall be kept closed and locked except for the purpose of inspection, alteration or repair, and shall not be obstructed in any manner: Provided that this shall not apply in the case of

(i) switch-boards the backs whereof are accessible only through an opening in the wall or partitions against which they are placed, if such openings are kept closed and locked; (ii) switch-boards which have no uninsulated conductors accessible from the back; (iii) switch-boards for voltages not exceeding low voltage; or (iv) switch-boards the switch-gear of which is of a totally enclosed construction. Portable electric tools and lights 7 (1) No user shall permit the use of, and no person shall use, a portable electric tool the operating voltage of which exceeds 50 volts unless (a) it is connected to a source of electricity supply incorporating an earth leakage protection device of a type and construction approved by the Chief Inspector; or (b) it is connected to the source of electricity supply through the interposition between each tool and the source, of an individual double wound isolating trans-former, the secondary winding of which is not earthed at any point and which is construed in accordance with a code approved by the Chief Inspector, and the screen or core earthed; or (c) it is connected to a source of high frequency electricity supply derived from a generator which is used solely for supplying power to such portable electric tool and which arrangement is approved by the Chief Inspector; or (d) it is constructed with double insulation in accordance with a Chief Inspector. code approved by the (2) No user shall require or permit any person to and no person shall use a portable electric light unless (a) it is fitted with a handle which is robust and made of non-hygroscopic, non-conducting material; (b) all live metal parts or parts which may become alive due to a circuit fault are completely guarded so as to prevent danger through accidental contact; (c) the lamp is protected by means of a substantial guard firmly fixed to the insulated handle; (d) the cable lead-in is such that usage can be withstood without failure or damage to the insulation. (3) In wet or damp situations in closely confined spaces, inside metal vessels or in general in contact with large masses of metal, no portable electric light shall be used unless, in addition to the requirements contained in subsection (2), the operating voltage of the lamp does not exceed 30 volts and where the power supply is derived from a transformer such transformer shall have separate windings, and the extra low voltage winding must not be earthed but the transformer screen or core must be earthed. PART II MAINTENANCE Examination and repairs 8 A user shall not permit any examinations, repairs, or alterations necessitating the dangerous approach to, or the handling of electrical apparatus to be carried out while such apparatus is alive, unless such work is done by or under the constant supervision of a competent person. 9 Every user shall provide free of charge and maintain in good condition suitable rubber mats, gloves or gauntlets, safety belts and such other protective equipment as may be necessary to prevent accidents, for the use of persons engaged in examination, repairs or alterations necessitating the dangerous approach to, or the handling of live mains or electrical apparatus. Temporary earthing and isolation 10 (1) Whenever work is be carried on any electrical apparatus which has been disconnected from all sources of supply but which is liable to acquire or retain an electrical charge, the user shall cause

adequate precautions to be taken, earthing or other means, to discharge electrically such electrical apparatus or any adjacent electrical apparatus if there is any danger therefrom, before it is handled, and to prevent any conductor or electrical apparatus from being charged while person are working thereon. (2) No electrical apparatus shall be reconnected to a supply of electrical energy after examination, adjustment, repair or alteration has been undertaken unless such work has been carried out or inspected and approved by a qualified or competent person. [substituted by SI 285/82 with effect from 14 th May, 1982] Earthing, general 11 A user shall cause all accessible metallic portions of electric plant or apparatus which, though normally not forming part of an electrical circuit, may become alive accidently, to be protected by an insulating covering or by other efficient means, or to be connected to earth by a conductor of adequate cross-section area: Provided that his requirement shall not apply to (i) metal in earth-free situations, other than runs of metal conduit and close-fitting metal sheathing and armourings of cables; (ii) short isolated lengths of heavy-gauge metal conduit use for mechanical protection of metalsheathed or tough rubber protected cables such cables are not used in the secondary circuits of luminous-discharge tube lighting installation; (iii) short unexposed isolated lengths of metal conduit used for the mechanical protection and insulated wiring passing through floors, walls, partitions or ceilings; (iv)metal work of fixed electrical equipment, where such metal works is more than 2,4 mtrs above the floor and is neither situated in any position likely to become damp, nor in a lift shaft or near running machinery, nor in contact with a wall, ceiling Chapter 14:08 Factories and Works (Electrical) Regulations, 1976 or other support constructed of or covered with conducting material; (v) metal parts of electrical apparatus, where such parts are enclosed or shrouded by insulating material so that such metal parts cannot be touched; (vi) cleats, clips, saddles, clamps or other devices for fixing conduits and cables; (vii) lamp-caps; (viii) shades, reflectors, and guards, supported on holders, or lighting fittings of non-conducting material; or (ix) metal parts on, or screws in or through, non conducting materials separated by such material from current carrying parts and from earth non-current carrying parts in such a way that in normal usage they cannot become alive or come into contact with earthed parts. PART III INSTALLATION Transformer- or switch-rooms and houses 12 (1) A user shall cause all transformer and switch houses (a) to be of a size sufficient to provide clear working space for operating or maintenance personnel and to be sufficiently ventilated so as to maintain the equipment at a safe temperature; (b) to be so constructed as to be proof against vermin, leakage, seepage and flooding; (c) to be supplied with natural light where possible and with artificial light, the intensity whereof shall not be less than 300 lux, which shall be controlled by a switch adjacent to the

entrance as to prevent danger to persons and to enable all equipment to be clearly distinguished, and all instruments, labels and notices to be easily read; (d) to be so constructed that no windows are within easy reach of bare conductors or exposed live parts of electrical apparatus; (e) to have doors opening outwards and which can be readily opened from the inside; and (f) to be provided with adequate fire extinguishing appliances suitable for use on electrical equipment, which shall be maintained in good working order. (2) A user shall cause all cable ducts in transformer and switch houses to be covered with suitable non-slip material. (3) No person other than a competent person shall enter or be required or permitted by the user to enter a transformer or switch house unless all live conductors which are not adequately insulated against inadvertent contact are screened off: Provided that the competent person may be assisted by any other person acting under his immediate supervision.