SENTINEL BATTERY MONITORING

Battery Monitoring System

Battery Management at it's best! Technologies

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

TRIPS AND FAULT FINDING

Cellwatch Battery Monitoring Systems

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Stationary Batteries: Why they fail and what can be done to prolong battery life

Automatic DC Power Supply/Battery Charger

Est Battery Data Logger BDL3000

Battery Technology for Data Centers and Network Rooms: Site Planning

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Battery Monitoring Systems

AT EVO SERIES BATTERY CHARGER

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Factory Data: MOSFET Controls Supercapacitor Power Dissipation

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Battery Maintenance Solutions for Critical Facilities

Foreword

Standby Battery Life Management: Breaking the Price Barrier

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel.

Modbus Register Map:Galaxy VM (3: kVA 400/480V)

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

Magellan Utility Scale Energy Storage

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

ATevo SERIES BATTERY CHARGER

MCE TM Product Information 5 kv Electric Motor Analyzer

Why Ni-Cd batteries are superior to VRLA batteries. Statements and facts

icon Solar Battery Charge Controller for Home UPS

Maintaining the operating temperature of the battery at 20 C to 25 C will maximize its service life and efficiency.

EVO AT SERIES BATTERY CHARGER

Battery Monitor Products. Trust Your Batteries TM. Doing it right!

AT SERIES EVO BATTERY CHARGER

BATTERY TESTING SOLUTIONS

Proper Torque Values for Connection Hardware. 90 to 100 in-lbs

AN INTRODUCTION TO THE BENEFITS OF IMPRES ENERGY SOLUTIONS

Remote Condition Monitoring

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

BATTERY MONITORING SYSTEM RPB-24

Model UPS NXRT-1000 NXRT-1500 NXRT-2000 NXRT-3000 Model EBP NXRT-EBP1 NXRT-EBP2 NXRT-EBP3 NXRT-EBP3

TROJAN BATTERY COMPANY Renewable Energy Warranty Claim Form

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

White Paper. Direct Current Load Banks for Battery Capacity Testing

3400W Solar Battery Charger Maximum Power Point Tracker

Hydro Plant Risk Assessment Guide

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

INTELEPOWER CXS SWITCHING SYSTEMS

Station dc supply voltage. Electrolyte level. Inspect: Verify:

User Manual WatchPower App

Stationary Battery Testing

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

BATTERY CHARGERS.

REOZM SERIES GENERATORS. for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw

Powerware Master Modbus

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies

SNMP dedicated to ORVALDI Solar Infini

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

Duo Battery Charge Controller

» Sophisticated» Reliable» Intelligent

8 Troubleshooting and Maintenance

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz

3400W Solar Battery Charger Maximum Power Point Tracker

Low and medium voltage service. Power Care Customer Support Agreements

Three Phase UPS Systems Range: 10 to 500kVA

Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., November, 2016 ABB lead the intelligent revolution Intelligent technology (Part 2)

User Manual. Solar Charge Controller 3KW

3400W Solar Battery Charger Maximum Power Point Tracker

Aurora Single Phase Emergency Lighting Inverters

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

One-Stop Service: Monitoring and Managing.

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

OutdoorXUPS-600AHV-8364

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Developing PMs for Hydraulic System

Illuminator Series CR NEMA 3R

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

80V 300Ah Lithium-ion Battery Pack Data Sheet

TLE Series UPS 750/1000 kw With eboost Technology

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

Asian paper mill increases control system utilization with ABB Advanced Services

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

FEATURES & BENEFITS. 10 year design 25 C

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

INTRODUCTION. Specifications. Operating voltage range:

Transcription:

Integrated Inverter/Battery Monitoring System (IBMS) Battery monitoring at its finest Maintenance Bypass Switch Input AC to DC Converter DC to AC Inverter Static Bypass Switch Output Operations: Normal Standby Maintenance Battery System Control Alarm and Display Optional Inverter/ Battery Monitoring System (IBMS)

DSPM s Monitoring System (IBMS) If you re operating mission critical systems relying on the protection of a UPS with battery bank, system monitoring is essential. It s about peace of mind - knowing that the system is functioning properly and being constantly monitored. Knowing that everything has been done that can be done, to protect your enterprise from the consequences of a power failure. All batteries will fail, it is just a matter of time It only takes the failure of one battery to compromise the entire battery string. It is often assumed that batteries are meticulously maintained, but this is rarely so. Many batteries are not inspected or maintained beyond an annual service visit. Unknown and undetected battery failures become apparent right at the time when you need the batteries the most - during a power failure. DSPM Monitoring System provide more than rudimentary battery monitoring. The IBMS can identify faults within individual batteries, and detect an imbalance in the performance of multiple strings. To ensure the integrity of the battery system, it is necessary to detect failing blocks before they affect the performance of the entire system. The effectiveness of a battery monitoring system is proportional to the number of points that are monitored and the frequency that this occurs. With regular monitoring comes the accumulation of data, the ability to report and spot trends, and the ability to take timely remedial action. DSPM s IBMS provides an advanced and most cost-effective tool for monitoring battery banks. DSPM s continuous data sampling, reporting and battery monitoring capability delivers reduced costs, gives peace of mind, and most importantly - ensures that you have batteries that perform when needed. When and where it matters the most DSPM s Monitoring System takes a total approach to battery monitoring. This means that by selecting from a range of options, the system can be tailored to meet your specific requirements. Maintenance free VRLA or wet cells, lead acid or Nicad - DSPM has a solution for your battery. Understanding your batteries Individual battery voltage Incorrect charge voltages may result in loss of capacity, accelerated grid corrosion, excessive gassing and premature end of life. Voltage also identifies catastrophic failures, such as short circuit cells, and gives true visibility of performance under discharge. Ambient temperature A battery s life-span is normally specified at 20 or 25 degrees centigrade. Temperatures outside of the specified range can significantly affect the battery s corrosion rate, and therefore the life of the battery. An 8-10deg temperature increase can decrease battery life by 50%. String current String current monitoring measures the energy delivered or accepted by each battery string. A UPS will only measure total current and cannot detect imbalances between strings. An imbalance highlights potential problems within a battery string. String current measurement also allows detection of incorrect battery charging and any significant earth leakage faults. Individual battery The impedance of a battery will increase with age. High impedance results in a battery that cannot supply the required current - its key task. High impedance also highlights poor connections and open circuit batteries before failure. Batteries can fail in a very short period of time (less that a week) so measuring batteries daily allows you to detect faulty batteries. By trending battery voltage you can accurately determine the end-of-life of the battery. It is designed to be evaluated every month.

Battery temperature Measuring the temperature of each battery highlights poor connections and excessive charger ripple. Temperature is a critical parameter for all batteries. Most importantly, battery temperature measurements allow the early detection of thermal runaway. The financial benefits By definition, wherever there is a bank of batteries, there is a mission-critical environment being protected. It follows that if the batteries are unable to perform when they are needed, the consequences and costs are going to be serious. Power failures happen all too often and at a time like that the investment in the UPS, battery bank and battery monitoring system needs no further financial justification. System Monitoring features 24/7 alarm notification. Automatic capture and recording of data during float, charge & discharge. Voltage sampling - all batteries simultaneously every minute. Planned battery purchasing - through avoiding emergency replacements. Built in intelligence for battery state recognition and comparable voltage readings. User defined alarm limits. On-board memory. Batteries Flexible to suit battery model & application. However, even in day-to-day operation, DSPM battery monitoring provides a strong return. The following cost savings are worth considering: Fewer batteries to purchase - through extending the service life of the ones installed. Reduced manpower - through automation & reduced number of discharge tests. Reduced call-out charges - through effective preventive maintenance. Planned battery purchasing - through avoiding emergency replacements. Reduced travel and time - through remotely accessing status data. Successful warranty claims - through having documentary evidence. Reduced insurance premiums. Guarantee battery power when needed. Avoid liability claims.

Ensure that you can see and understand what is happening in your inverter system including all batteries, charger and inverter parameters. NEMA 3R or NEMA 4/12 Outdoor Internet/Ethernet NEMA 1 Battery Monitoring Software Permanent monitoring not only offers increased measurement frequency and consistency, it allows this do be done with greater safety and security. Keep personnel out of hazardous battery rooms and away from sensitive plants & operations. Simplify your health & safety planning and focus on your core operations. Inverter Cabinet Battery Cabinet Email Alarm/Remote Dispatch DSPM Monitoring Software Proactive monitoring tool Real time battery status Alarm & activity log with on-screen pop-ups and email alerts Live discharge display Automated data management Battery history database for life trending Point & click report generation Data presentation is the key for efficient management A single battery monitoring system can monitor up to 46 batteries per cabinet. Connecting multiple systems via DSPM Monitoring Software gives visibility to an unlimited number of batteries from a single desk. DSPM Monitoring offers: LAN integration for remote monitoring via software.

Technical Specifications Sentinel Monitor The monitor captures, processes and stores data from a range of sensors. Battery Inputs Unlimited Memory 350,000 Data Points Sensor Type Volt, Current, Temperature Operating Temperature 0ºC to 50ºC/32ºF to 122ºF String Voltage 240V-600VDC Storage Temperature 0ºC to 70ºC/32ºF to 158ºF Current Inputs All Batteries Service Port RS232, RJ45 Sensor Type Measurement Range Holl Effect 0A-1000A Comport 1 Primary monitoring connection with option of: Ethernet - 10Base-T Voltage Accuracy ±1% + Sensor Accuracy Measurement Range 0ºC to 80ºC/ 32ºF to 176ºF Temperature Accuracy ±1ºC/1.8ºF DSPM Monitoring System is UL Listed