BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

Similar documents
Motors and drives for applications in explosive atmospheres

VALIADIS S.A. HELLENIC MOTORS

Product note Low voltage flameproof motors for underground mining

ATEX LABELLING FOR MOTORS AND GEAR UNITS

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

SERIES R - MD MOR & GOR

High voltage flameproof induction motors The simplest solution for hazardous environments

INSTRUCTION MANUAL (ATEX / IECEx)

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Solenoid coils VACF Type codes

INSTRUCTION MANUAL (ATEX / IECEx)

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Explosion and flame-proof cast iron electric motors

Sensor boxes SRBE Key features and product range overview

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Brushless Servo Motors

Modular Explosion Proof Brakes. IECLine rev 0

NEW Explosion protection

EX-D ENCLOSURES AND DISTRIBUTIONS

Explosion and flame-proof single phase electric motors

Process performance IE3 aluminum motors, 50/60 Hz The product range for global customers

Flameproof Enclosures

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

xplosion Proof Motors hoyermotors.com Explosion Proof

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion-proof motors

ILED Dorado. User Manual

Flameproof DC motors for hazardous locations. C Series DC motors. Grandezze-Sizes Catalogo Catalogue. Code C-DC-ATEX-7-23-E-11

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

JBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

BFG range BFGC range BFN range

Explosion-proof motors

BFG range BFGC range BFN range

Motors for hazardous areas New cast iron motors in sizes

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Low voltage Motors for explosive atmospheres Installation, operation, maintenance and safety manual

Latest news on explosion protection

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

AUTOMATISIERUNGSTECHNIK ENGINEERING INDUSTRIEHANDEL INDUSTRIESERVICE TECHNIK. Blumenbecker Service-Nr.: /

Cabinet-built single drives, ACS880-07

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

APPLICATION GUIDE. Pure easiness for a wide range of applications ACS580 general purpose drives

Panelboards & Motor Starters

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

HAZARDOUS AREA MOTORS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Ex m Solenoid Operator Type 0519

Expand your business with new EXPLOSION PROOF WORK LIGHTS

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Load disconnect switch Series 8146/5-V11

Explosion-Proof Motors Increased Safety

Pneumatic control unit for decentralized automation of ELEMENT process valves

ATX DPD Series Distribution Panelboards Flameproof

Fans for ATEX EXPLOSIVE ATMOSPHERES

Certificate of Compliance

The filling level sensors are designed in accordance to the following standards

ILED Aquarius Illuminated Windsock. User Manual

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

RVP-R- VAV controller. In explosion-proof version

Catalog. Brochure. Baldor explosion proof AC and DC Motors. Catalog

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Modular Flameproof Brakes

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

OPERATING INSTRUCTIONS

Operating Instructions

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Type Electronic Limit Switch

ROOF SPECIALIZED WORK LIGHTS FOR EXPLOSIVE AREAS

Terminal Boxes TNCN. Explosion protection Marking

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

M3000 Motors for Hazardous Areas. Low Voltage Non-sparking Motors Ex na, EEx na

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Industrial Vacuums ATEX IECEX certified

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Limit switch attachments DAPZ

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Centrifugal medium-pressure fans fitted with multi-blade

PAB Atex-certified centrifugal pumps

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

Ex e, ia Junction boxes TNCN. Features

Welcome to BU Motors and Generators product overview e-learning.

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SERIES 54 Inductive Proximity Sensor

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

Transcription:

BROCHURE Low voltage motors and drives for applications in explosive atmospheres

2 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES

ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES 3 Certification. Diligence. Reliability. Safety. Everything counts. Are you looking for maximized productivity without compromizing safety? Is compliance with global and local standards and regulations together with swift project execution important to you? That s where ABB can help you. Our extensive experience working with explosive atmospheres along with our comprehensive motor and drive testing ensure that the components are combined in the optimal way to cope with the circumstances on site. Our wide global support network and extensive range of services ensure that your motor and drive packages keep running reliably with top performance throughout their life cycle. You ll have the full advantage of accurate motor speed control without compromising on safety or reliability. The benefits of purchasing a motor and a drive together from ABB for applications in potentially explosive atmospheres Cost and time savings as no project-specific testing and certification of the motor and drive combination is needed. Cost savings due to optimized performance of the motor and the drive package; there is no need to oversize the motor. Selecting the right motor and drive is very easy with our software tools and instructions. Tested motor and drive combinations make thermistor protection optional and save on installation costs.

4 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES Low voltage motors and drives for potentially explosive atmospheres By using an ABB motor together with an ABB drive, you can enjoy the benefits of efficient, high-performance motors with optimal speed and control accuracy without compromising on safety. Tested with ABB motors Easy to select, install and use Drives for reliable and efficient motor control ATEX-certified built-in overtemperature protection modules Meet extensive chemical industry requirements, including NAMUR recommendations Reliable and accurate DTC functionality together with sine filter

ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES 5 ABB has a wide range of robust, reliable and efficient products for demanding environments, together with decades of experience and know-how in industrial applications. We can offer you full support throughout your project. Wide range of protection types and suitable applications Wide range of high-performance motors Certified to national and international standards Designed for reliable and safe operation with variable speed drives Available with efficiency classes IE2 and IE3 Meet national energy efficiency requirements, MEPS (minimum energy performance standards)

6 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES 01 02 03 04 05 06 07 08 09 10

ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES 7 Typical applications A potentially explosive area is defined as a location in which gases, vapors, mist or dust mixed with air may form a flammable mixture. These areas can be found in, for example, a sawmill where sawdust has been allowed to gather in large amounts, in a food factory handling sugar or flour, and in sewage treatment where methane is present. Below is a list of industries, relevant to the respective motor and drive family, where explosive atmospheres often exist. 01 Oil and gas 02 Chemical industry 03 Mining 04 Water treatment 05 Food and beverage 06 Sawmills 07 Pharmaceutical 08 Textile industry 09 Marine 10 Power generation Correct dimensioning is important We help you to size motors and drives to your exact needs. Correctly sized motors and drives reduce motor frame heating and sparking from bearing currents. They also help you to reduce your energy use. We have the certificates We have our own test center where we can test and certify motor and drive combinations. Our low voltage motors for explosive atmospheres and low voltage industrial drives have been tested to verify that, when correctly dimensioned, they are always safe to use in explosive atmospheres. Global service and support network Our global network of certified service providers are trained and experienced to help you with motors and drives for applications in explosive atmospheres. Our service ensures that your ABB Declaration of Conformity is retained.

8 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES Motor selection table Ex motor Motor type Gas/dust group Temp. class Equipment protection level (EPL) Motor power Motor frame size Efficiency class IP class 1) Flameproof Ex d M3JP IIB or IIC T4 Gb 0.55 to 710 kw IEC 80 to 450 IE2, IE3 IP55 Flame proof I Ex d (underground mining) M3JM Mb 0.55 to 710 kw IEC 80 to 450 IE2, IE3 IP66 Flameproof Ex de M3KP IIB or IIC T4 Gb 0.55 to 950 kw IEC 80 to 450 IE2, IE3 IP55 Increased safety Ex ec (formerly Non-sparking Ex na) M3GP cast iron IIC T3 Gc 0.25 to 1000 kw IEC 71 to 450 IE2, IE3 IP55 Increased safety Ex ec (formerly Non-sparking Ex na) M3AA aluminum IIB T3 Gc 0.25 to 90 kw IEC 71 to 280 IE2, IE3 IP55 Increased safety Ex eb (formerly Ex e) M3HP IIC T3 Gb 0.25 to 390 kw IEC 80 to 400 IE2 IP55 Dust ignition proof Ex t M3GP cast iron IIIB or IIIC T125/150 C 2) Db/Dc 0.25 to 1000 kw IEC 71 to 450 IE2, IE3 IP65/IP55 Dust ignition proof Ex t M3AA aluminum IIIB/IIIC T125 C Db/Dc 0.25 to 90 kw IEC 71 to 280 IE2, IE3 IP65/IP55 Larger motors for explosive atmospheres for VSD duty on request. 1) Higher IP class on request 2) Temperature class T150 C when surface temperature protection with PTC is used. Note! The drive must be installed in a non-ex area

ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES 9 Protective functions Motor certification EC Declaration of Conformity Winding equipped with temperature sensor to protect the insulation as standard. It is recommended to connect the sensor to the VSD through a safety circuit. PTC sensors for surface temperature control of low voltage motors is available as a standard option. Winding equipped with temperature sensor to protect the insulation as standard. PTC sensors for surface temperature control of low voltage motors are available as a standard option. Winding equipped with temperature sensor to protect the insulation as standard. It is recommended to connect the sensor to the VSD through a safety circuit. PTC sensors for surface temperature control of low voltage motors are available as a standard option. Winding equipped with temperature sensor to protect the insulation as standard. It is recommended to connect the sensor to the VSD through a safety circuit. In size 160 and above, winding is equipped with temperature sensor to protect the insulation as standard. It is recommended to connect the sensor to the VSD through a safety circuit. For other VSDs, protection is available with thermistors limiting the surface temperature of the motor (option +813). For other VSDs, protection is available with thermistors limiting the surface temperature of the motor (option +813). For other VSDs, protection is available with thermistors limiting the surface temperature of the motor (option +813). As standards require Ex eb motors to be tested together with the specific drive, Ex d / Ex de motors are usually offered instead for practical reasons. Winding equipped with temperature sensor to protect the insulation as standard. It is recommended to connect the sensor to the VSD through a safety circuit. PTC sensors for surface temperature control of low voltage motors are available as a standard option. In size 160 and above, winding is equipped with temperature sensor to protect the insulation as standard. It is recommended to connect the sensor to the VSD through a safety circuit. For other VSDs, protection is available with thermistors limiting the surface temperature of the motor (option +813). We have tested and certified our motors for explosive atmospheres with our drives. Therefore when you purchase a motor and a drive together from ABB, you save time and money, as no additional testing and certification are needed.

10 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES Drive selection table Drive family Type and construction Supply voltage Power range ATEX-certified STO ATEX-certified protective functions ACS880 ACS880-01 208 to 690 V 0.75 to 250 kw +Q971 +L537 +Q971-11, -31 380 to 500 V 2.2 to 110 kw +Q971 +L537 +Q971-04/-04F 380 to 690 V 250 to 2200 kw +Q971 +L537 +Q971-04XT 380 to 690 V 630 to 1200 kw +Q971 FPTC-02* ) +Q971 -M04 200 to 500 V 0.37 to 45 kw -14, -34 380 to 690 V 200 to 2200 kw +Q971 +L537 +Q971 -multidrive modules 380 to 690 V 1.5 to 3200 kw +Q971 FPTC-02* ) +Q971 -liquid-cooled multidrive modules 525 to 690 V 355 to 3000 kw +Q971 FPTC-02* ) +Q971-07 380 to 690 V 55 to 2800 kw +L513/L514/L537 +Q971-17, -37 380 to 690 V 55 to 3200 kw See next column +L513/L514/L537 +Q971 -multidrives 380 to 690 V 1.5 to 5600 kw +L513/L514/L537 +Q971 ACS800 -multidrive modules LC 380 to 690 V 1.5 to 2800 kw - ACS800 -multidrives LC 380 to 690 V 1.1 to 5600 kw See next column +L513/L514 +Q971 ACS580-01 380 to 480 V 0.75 to 250 kw +L537 +Q971-04 380 to 480 V 250 to 500 kw See next column +L537 +Q971-07 380 to 480 V 75 to 500 kw +L537 +Q971 Note! The drive must be installed in a non-ex area * ) ATEX-certified thermistor protection module kit for ACS880 multidrive modules available with an MPR order code

ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES 11 Recommendations The customer can connect the motor thermistor sensors to the interface of the ATEX-certified thermistor protection module FPTC-02 (+L537 +Q971), which executes the protection function Safe Motor Temperature (EN/IEC 61800-5-2). Alternatively, the customer can build the temperature protection function with a motor temperature sensor, an ATEX-compliant protection relay and the ATEX-certified Safe Disconnection Function of the drive (+Q971). The customer can connect the thermistor sensors of the motor to the interface of the ATEX-certified protection module FPTC-02 (+L537 +Q971), which executes the protection function Safe Motor Temperature (EN/IEC 61800-5-2). Alternatively, the customer can connect the motor temperature sensors to the protective function (PTC/Pt100) of the drive (+L513/+L514 +Q971). The customer can build the safety circuit by connecting the motor temperature sensors to a certified PTC/PT100 relay, which controls the main contactor of the drive. In this case, the contactor should be dimensioned to withstand twice the nominal current of the drive. The customer can connect the motor temperature sensors to the protective function (PTC/Pt100) of the drive (+L513/+L514 +Q971). The customer can connect the motor thermistor sensors to the interface of the ATEX-certified thermistor protection module CPTC-02 (+L537 +Q971), which executes the protection function Safe Motor Temperature (EN/IEC 61800-5-2).

For more information, please contact your local ABB representative or visit abb.com/drives abb.com/motors&generators Copyright 2018 ABB. All rights reserved. Specifications subject to change without notice. 3AUA0000158367 REV C EN 23.08.2018