GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Similar documents
NI 9251 with mini XLR

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs

GETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate

GETTING STARTED GUIDE NI AI, 51.2 ks/s/ch Simultaneous, Universal Measurements

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

CALIBRATION PROCEDURE NI Channel, ±0.5 V, 24-Bit Simultaneous, Channel-to-Channel Isolated Analog Input Module

Bracket and Assembly Dimensions

CALIBRATION PROCEDURE NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

NI Pin DSUB to Screw-Terminal Connector Block

Industrial Rack Mount Kit for CompactRIO and CompactDAQ

Contents. Software. CALIBRATION PROCEDURE NI PXIe Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module. ni.com/manuals

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices

NI PS-15/16/17 Side Mount Brackets

SCXI Power Supply/Float Charger Installation Guide

NI TB Introduction INSTALLATION INSTRUCTIONS. Terminal Block for the NI PXI/PXIe-2527

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

362 Clamp Meter. Users Manual

Solenoid coil for control in potentially explosive areas Type BZ

i3000s/i2000 Flex AC Current Probe

F5 Platforms: FIPS Kit Installation MAN

PF 3100 ION PILOT CARD PRO.FIRE

Installation Instructions

Megohmmeter Test Probe

2-Year Limited Warranty. See the Users Manual for the full warranty.

Safety Standards. Model Number:

323/324/325 Clamp Meter

365 Detachable Jaw True-rms Clamp Meter

373 Clamp Meter. Users Manual

707Ex. Users Manual. ma Calibrator

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Installation and Operating Manual

BroadBand PowerShield. 20 AHr Battery. User Manual

Switching DC Power Supply

Leica GKL341 User Manual. Version 1.0 EN

- Wiring Brochure Mixing Expansion Module 440

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Solenoid Operator 0516 / 1216

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

A419ABG-3C Electronic Temperature Control

Technical Data. Dimensions

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INTERNATIONAL METAL ENGINEERING

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

INSTALLATION INSTRUCTIONS

650mA Phase Dimmable LED Driver

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

EStrong-series Emergency Stop

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

MINI MCR-SL-UI-UI(-SP)(-NC)

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Powerware Vdc Extended Battery Cabinet User s Guide.

CONTROL MICROSYSTEMS Power Supply. Hardware Manual

Model Fixed Rack-Mount Kit

362 Clamp Meter. Users Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog Data Sheet

Electrical Installation


EU RO Mutual Recognition Technical Requirements

3-Year Limited Warranty. See the Users Manual for the full warranty.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

1100 Series Piston Type Differential Pressure Gauges

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Ex m Solenoid Operator Type 0519

WF3132 User s Manual. AC rev D

DALI 650mA LED Driver

and Accelerometers

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

1000mA - 650mA Phase Dimmable LED Driver

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Solenoid Operator 0513 / 1213

Phase Sequence Tester

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

80 Series V Digital Multimeter Safety Information

POWERWARE User s Guide VA.

Tina 4A Connection block

Load and Motor Switches, Load-Break Switches Series 8544

SERIES 54 Inductive Proximity Sensor

BMRX Series ROTARY LEVEL CONTROL

Safety and General Information

HIGH VOLTAGE DIGITAL AMMETER

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Mini Multimeter with Non-Contact Voltage Detector (NCV)

F261 Series Fluid Flow Switches

Load and Motor Switches, Load-Break Switches Series 8549

Transcription:

GETTING STARTED GUIDE NI 9223 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

This document explains how to connect to the NI 9223. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9223. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9223 only as described in this document. Caution Do not operate the NI 9223 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair. 2 ni.com NI 9223 Getting Started Guide

Safety Voltages Connect only voltages that are within the following limits: Isolation Channel-to-channel Continuous Withstand Channel-to-earth ground Continuous Withstand 60 VDC, Measurement Category I 1000 Vrms, verified by a 5 s dielectric withstand test 60 VDC, Measurement Category I 1000 Vrms, verified by a 5 s dielectric withstand test Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary NI 9223 Getting Started Guide National Instruments 3

circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution Do not connect the NI 9223 to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Safety Guidelines for Hazardous Locations The NI 9223 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 and Ex na IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9223 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. 4 ni.com NI 9223 Getting Started Guide

Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15. Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9223 with screw terminal has been evaluated as Ex na IIC T4 Gc equipment under DEMKO Certificate No. 07 ATEX 0626664X and is IECEx UL 14.0089X certified. The NI 9223 with BNC has been evaluated as Ex na IIC T4 Gc equipment under DEMKO Certificate No. 12 ATEX 1202658X and is IECEx UL 14.0089X certified. Each NI 9223 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient NI 9223 Getting Started Guide National Instruments 5

temperatures of -40 C Ta 70 C. If you are using the NI 9223 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage. Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC 60664-1. Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) 6 ni.com NI 9223 Getting Started Guide

stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded accessories. Caution Electrostatic Discharge (ESD) can damage the NI 9223 with screw terminal. To prevent damage, use industry-standard ESD prevention measures during installation, maintenance, and operation. NI 9223 Getting Started Guide National Instruments 7

Caution To ensure the specified EMC performance, operate the NI 9223 with screw terminal only with double-shielded, twisted pair cables. Caution To ensure the specified EMC performance, operate the NI 9223 with BNC only with shielded cables. Caution To ensure the specified EMC performance, the length of all I/O cables must be no longer than 30 m (100 ft). Cable Requirements for EMC Compliance Select and install cables for the NI 9223 with screw terminal in accordance with the following requirements: Connect the cable shield to the chassis ground (grounding screw of the chassis) using the shortest length of wire possible. Use shielded, twisted-pair cables (Belden 9451 or equivalent). 8 ni.com NI 9223 Getting Started Guide

Figure 1. Cable Connections for NI 9223 with screw terminal for EMC Compliance Signal Source Shield AI0+ AI0 Signal Source Shield AI1+ AI1 Signal Source Shield AI2+ AI2 Signal Source Shield AI3+ AI3 NI 9223 NI 9223 Getting Started Guide National Instruments 9

Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 10 ni.com NI 9223 Getting Started Guide

Preparing the Environment Ensure that the environment in which you are using the NI 9223 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude Indoor use only. 10% RH to 90% RH, noncondensing 5,000 m Note Refer to the device datasheet on ni.com/manuals for complete specifications. NI 9223 Getting Started Guide National Instruments 11

NI 9223 Pinout AI0+ AI0 AI1+ AI1 AI2+ AI2 AI3+ AI3 0 1 0 1 0 1 0 1 AI0+ AI0- AI1+ AI1- AI2+ AI2- AI3+ AI3-12 ni.com NI 9223 Getting Started Guide

Table 1. Signal Descriptions Signal AI+ AI- Description Positive analog input signal connection Negative analog input signal connection Grounded Connections + Signal Source AI+ AI NI 9223 Make sure the voltage on the AI+ and AI- connections are in the channel-to-earth safety voltage range to ensure proper operation. NI 9223 Getting Started Guide National Instruments 13

Floating Connections Signal Source + AI+ AI NI 9223 NI 9223 Connection Guidelines Make sure that devices you connect to the NI 9223 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9223 with screw terminal. 14 ni.com NI 9223 Getting Started Guide

Wiring for High-Vibration Applications If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI 9223 with screw terminal: Use ferrules to terminate wires to the detachable connector. Use the NI 9971 backshell kit. Overvoltage Protection The NI 9223 provides overvoltage protection for each channel. Note Refer to the device datasheet on ni.com/manuals for more information about overvoltage protection. NI 9223 Getting Started Guide National Instruments 15

Where to Go Next CompactRIO NI CompactDAQ NI 9223 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9223 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals 16 ni.com NI 9223 Getting Started Guide Installs with the software

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9223 Getting Started Guide National Instruments 17

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2010 2016 National Instruments. All rights reserved. 374223D-01 Feb16