1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Similar documents
1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Enclosures. Section E

Junction Boxes Hazardous and Non-Hazardous

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

EDS / EFS Series Control Stations

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

W-Series Junction Boxes

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

EDS / EFS Series Control Stations

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

EDS / EFS Series Control Stations

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Covers for Cast Iron or Aluminum Device Boxes

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Hazardous Factory Sealed Control Devices

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Motor Starters Hazardous and Non-Hazardous

Plugs and Receptacles: Hazardous Location

Condulet Conduit Bodies and Outlet Boxes Hazardous

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

EBMC Combination Line Starters and Enclosures

Circuit Breakers Hazardous

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Spring-loaded cover seats against neoprene gasket.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Condulet Cast Device Boxes and Covers Application and Selection

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Control Stations Hazardous and Non-Hazardous

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

PEERLESS BLOWERS DIRECT DRIVE BLOWERS

Lighting and Power Distribution Panelboards

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Applications. Illustrated Features

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Division 1 Explosionproof Panelboards

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

GHG43 Series Control Stations

Hazardous Duty Applications

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

Standard Materials Bodies and covers: copper-free aluminum.

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE

X1PB: Explosionproof Panelboards

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

ACE20 explosionproof variable frequency drives Utilizes Allen-Bradley PowerFlex 700 drives

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

AKRON ELECTRIC, INC. CONDUIT PRODUCTS GR SERIES... EYS SERIES... TU SERIES... XBD-50 SERIES...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

SynergEX Panelboards for Hazardous Locations

SKINNER Intrinsically Safe Series Four-Way

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Jefferson Electric Class I Division 2 Transformers for hazardous locations

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

Transcription:

Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch circuit taps For housing terminal blocks, relays and other electrical devices Indoors or outdoors in damp, wet, dusty, corrosive, hazardous locations Where exposure to frequent or heavy rain, water, spray, moisture, and humidity is common, such as: offshore drilling facilities, cooling towers, coal preparation and handling facilities and sewage and waste water treatment plant In areas which are hazardous due to the presence of hydrogen or gases and vapors of equivalent hazard such as found in process industries, missile bases and gas manufacturing plants Features: Style C boxes provided with aluminum plate cover as standard, allowing for field addition of cover device holes Stainless steel cover bolts (Style C only) Ground joint cover opening provides maximum opening for pulling wires or mounting equipment Walls of bodies may be drilled and tapped for conduit entries as shown in listings Stud bolts in diagonally opposite corners of body aid in aligning cover to body during installation (not furnished with hinged covers) All Style C bodies are provided with captive, triple lead, quick release hex head stainless steel bolts with spring loaded action which provides clear indication that cover bolts are fully retracted from the body External flange design wide unobstructed cover opening provides a completely accessible interior for wiring and electrical equipment Square corners of enclosure body provide maximum interior space and area for conduit openings Internal grounding lug provides a means to ground enclosed equipment Special neoprene cover gasket provides a watertight seal to meet NEMA 4 requirements, and provides superior protection for enclosed equipment against water/corrosion ATE certified when ordered with ATE suffix Enclosures are machined for field installed mounting plates Detachable mounting feet provide mounting flexibility. No need to replace enclosure if mounting feet are broken. Optional stainless steel hinges provide convenient and easy access for inspection, maintenance and systems changes Enclosures are machined to accept field installed hinges EJB2208 with optional hinged cover Certifications and Compliances: NEC/CEC Class I, Divisions and 2, Groups B*, C and D Class II, Division, Groups E, F and G Class II, Division 2, Groups F and G Class III Class I, Zones and 2 UL Standard 203 cul to CSA Standard C22.2 No. 30 ATE: Ex d IIB + H2 T, IP ATE certificate: PTB 0 ATE 020 U Enclosure Type 3, 3R, 4, 4*, BCD, EFG IEC Standard EN:00-0 and EN:00- Standard Materials: Body and cover copper-free aluminum (suffix -SA items and all Style C), Feraloy iron alloy (Style D) Gasket neoprene Cover bolts stainless steel (Style C), steel (Style D) Hinges stainless steel Standard Finishes: Copper-free aluminum natural Feraloy iron alloy electrogalvanized and aluminum acrylic paint Steel electrogalvanized Extruded aluminum natural Gasket Detail Cross section of cover. Gasket extends beyond flange surface by.05". EJB2208 with optional hinged cover and standard neoprene cover gasket Options: Description Suffix Hinged covers Hinges mounted on left (short side)... S58 Available on all Style C and the following Style D enclosures: EJB0008-SA, EJB20804, EJB20804-SA, EJB20808-SA, and EJB400-SA Hinge kits for field installation (no field machining required) EJB KIT EJB0080 through 3208... (2 hinges) EJB KIT 3 EJB3808... (3 hinges) EJB KIT 4 EJB32408... (4 hinges) For EJB0008-SA, EJB20804, EJB20804-SA, EJB20808-SA EJB KIT 5 and EJB400-SA... (2 hinges) Factory installed mounting plates for relays, terminal blocks, electrical devices, etc. Aluminum mounting plate kit for field installation (kit includes aluminum mounting plate, pillars and mounting hardware). No field machining required. See Ordering Information on next page... MP Factory installed terminal Information blocks... on request ATE Certified... ATE Bolted cover and body assembled. Compressed gasket forms watertight seal. *For Group B, install sealing fitting in each conduit run within 8" of the enclosure. To meet 4 requirement, add suffix S52 or S53. EJB3208, 3808, 32408 and all style D enclosures require sealing fittings within 8" of enclosure for each conduit run for Group C locations. Style D enclosures require sealing fittings within 8" of enclosure for each conduit run for Group D locations. For conduit liner ordering information, see page 850. 20

Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Style D Style D Nominal Inside Top & Sides Bottom Cat. # (aa) (bb) Depth Iron EJB00404 4 4 EJB08004 8 4 EJB0800 8 EJB08080 8 8 EJB20804 8 2 4 EJB0404 4 4 Aluminum EJB00404 SA 4 4 EJB08004 SA 8 4 EJB0800 SA 8 EJB08080 SA 8 8 EJB2004 SA 2 4 EJB20804 SA 8 2 4 EJB20808 SA 8 2 8 EJB0404 SA 4 4 EJB0008 SA 0 0 8 EJB400 SA 0 4 Style C EJB2208* with optional hinged cover Style C Cat. # Nominal Inside Sides (aa) Top & Bottom (bb) EJB0080 0 8 EJB2204 2 2 4 EJB220 2 2 EJB2208 2 2 8 EJB0 EJB08 8 EJB820 2 8 EJB8208 2 8 8 EJB24208 2 24 8 EJB2420 2 24 0 EJB24808 8 24 8 EJB2480 8 24 0 EJB242408 24 24 8 EJB24240 24 24 0 EJB3208 2 3 8 EJB3808 8 3 8 EJB380 8 3 0 EJB32408 24 3 8 EJB0222 0 22 2 Class I, Div. and 2, Groups C and D only. Depth Ordering Information: Junction boxes listed can be furnished with drilled and tapped openings, subject to material required and the limitations of maximum size and number of openings as well as spacing, as shown in Tables and 2. To Order: Step Select the box required from photos at left, listings, and dimensional drawings on next pages. Step 2 Select standard conduit arrangement from Table and maximum size conduit opening required from Table 2. Step 3 Select appropriate symbol for required drilled and tapped opening from Table 3. Example: Step Box required EJB08080 Step 2 Arrangement 2 Step 3 Openings two " drilled and tapped holes in top and bottom and two 2" drilled and tapped holes on each side. Step 4 Symbols are substituted and written in clockwise order starting with "a." When no opening is required at a particular location, use symbol "0" (zero). For this example: CC, GG, CC, GG. Complete Cat. No. is made up of three parts: Part box number; Part 2 arrangement number; Part 3 symbols for conduit openings. For this example: EJB08080-2-CC-GG-CC-GG If none of the standard arrangements meet requirements, send a sketch showing junction box number with size and location of each conduit opening desired. EJB Mounting Plate Kits (For Field Installation) Select kit number that matches junction box number. Example: EJB-MP40 is used in EJB400-SA Cat. # Style C EJB MP008 EJB MP22 EJB MP EJB MP82 EJB MP242 EJB MP248 EJB MP2424 EJB MP32 EJB MP38 EJB MP324 Cat. # Style D EJB MP004 EJB MP080 EJB MP0808 EJB MP20 EJB MP208 EJB MP04 EJB MP00 EJB MP40 Class I, Div. and 2, Groups C and D only. Plate has no center hole. *See Compliances on previous page. For conduit liner ordering information, see page 850. 2

Ordering Information Table Conduit Arrangement Diagrams Table 2 Conduit Arrangements Style D Maximum Trade Size and Number of Openings Top and Bottom (bb)* Sides (aa) Spacing Cat. # 2 3 4 2 3 4 S L2 S2 L3 S3 L4 S4 EJB00404 2 2 2 5 /8 5 /8 / 2 /8 EJB08004 2 2 /2 2 2 5 /8 2 /8 5 /8 2 3 2 /8 2 / EJB0800 3 /2 2 /2 3 /2 3 3 2 5 /8 2 3 2 /8 2 / EJB08080 3 /2 2 /2 3 /2 2 /2 3 3 2 2 2 3 2 3 2 / 2 / EJB0008 4 2 /2 /2 4 2 /2 /2 4 3 2 3 2 3 3 5 /8 3 5 /8 2 / 2 / EJB2004 2 2 2 2 /2 2 3 3 5 /8 4 /8 2 /8 3 /8 EJB20804 2 2 2 2 2 /2 2 /8 3 2 4 /8 2 3 3 / 2 / EJB20808 4 4 2 4 2 /2 4 3 3 2 4 /8 2 3 3 / 2 / EJB400 3 /2 3 /2 2 /2 /2 3 /2 2 /2 /2 3 /8 3 3 2 3 5 3 / 3 5 /8 2 / EJB0404 2 2 2 2 2 2 5 /8 3 / 4 /8 *Top and bottom are longer dimensions on enclosures which are not square. Conduit seals are required in all conduit entrances for Class I, Division, Group B hazardous areas, and for EJB3208, EJB3808, EJB380, EJB32408, and all Style D enclosures when used in Class I, Division, Group C hazardous areas. For other sealing requirements, consult the National Electrical Code*. Where standard arrangements are not adequate, special drilling and tapping can be ordered, or instructions can be provided for field drilling and tapping. Breathers and drains must be ordered separately. Maximum trade size for Group B application is 4". 22

Ordering Information Table 2 - Continued Conduit Arrangements - Style C Drilled and Tapped Openings Groups B, C and D Maximum Trade Size and Number of Openings Top and Bottom (bb)* Sides (aa) Cat. # 2 3 4 5 8 2 3 4 5 8 EJB0080 3 /2 3 /2 3 /2 2 /2 /2 EJB2204 /2 /2 /2 3 /2 /2 /2 3 EJB220 3 /2 3 /2 /2 3 3 /2 3 /2 /2 3 EJB2208 5 3 /2 /2 3 5 3 /2 /2 3 EJB0 3 /2 3 /2 2 /2 2 /2 3 3 /2 3 /2 2 /2 2 /2 3 EJB08 5 5 3 2 /2 3 5 5 3 2 /2 3 EJB820 3 /2 3 /2 3 /2 2 /2 /2 /2 3 3 /2 3 /2 /2 3 EJB8208 5 5 3 /2 2 /2 2 /2 5 3 /2 /2 3 EJB24208 5 5 5 3 /2 3 2 /2 2 /2 5 3 /2 /2 EJB2420 5 3 /2 3 2 /2 2 /2 3 /2 /2 EJB24808 5 5 5 3 /2 3 2 /2 2 /2 5 5 3 /2 2 /2 2 /2 EJB2480 5 3 /2 3 2 /2 2 /2 3 /2 2 /2 2 /2 EJB242408 5 5 5 3 /2 3 2 /2 2 /2 5 5 5 3 /2 3 2 /2 2 /2 EJB24240 5 3 /2 3 2 /2 2 /2 5 3 /2 3 2 /2 2 /2 EJB3208 5 5 5 5 4 4 3 /2 2 /2 5 3 /2 /2 3 EJB3808 5 5 5 5 4 4 3 /2 2 /2 5 5 3 /2 2 /2 2 /2 EJB380 5 5 4 4 3 /2 2 /2 3 /2 2 /2 2 /2 EJB32408 5 5 5 5 4 4 3 /2 2 /2 5 5 5 3 /2 3 2 /2 2 /2 Spacing Cat. # S L2 S2 L3 S3 L4 S4 L5 S5 L S L S L8 S8 EJB0080 3 3 /8 2 3 /8 3 2 3 /8 2 3 EJB2204 3 2 2 3 5 /8 3 5 /8 3 / 3 / 2 2 3 3 /2 EJB220 3 3 3 3 3 5 /8 3 5 /8 3 / 3 / 2 2 3 3 /2 EJB2208 4 3 3 3 3 5 /8 3 5 /8 3 / 3 / 2 2 3 3 /2 EJB0 3 3 3 3 4 5 /8 4 5 /8 4 3 / 4 3 / 2 3 2 3 2 /2 2 /2 2 2 3 3 EJB08 4 3 3 3 4 5 /8 4 5 /8 4 3 / 4 3 / 2 3 2 3 2 /2 2 /2 2 2 3 3 EJB820 3 3 3 3 3 5 /8 4 5 /8 3 / 2 3 2 2 3 3 2 /2 3 EJB8208 4 3 4 3 / 3 3 5 /8 4 5 /8 3 / 3 2 2 3 3 2 /2 2 EJB24208 5 /8 4 3 / 3 8 / 3 5 /8 3 / 4 5 /8 2 3 /8 2 3 /2 2 3 EJB2420 /8 4 3 3 8 / 3 5 /8 3 / 4 5 /8 2 3 /8 2 3 /2 2 3 EJB24808 5 4 3 / 4 3 / 8 / 4 5 /8 4 5 /8 3 3 /8 2 3 3 2 /2 2 3 2 EJB2480 4 3 4 3 8 / 4 5 /8 4 5 /8 3 3 /8 2 3 3 2 /2 2 3 2 EJB242408 5 3 /8 4 3 / 4 3 / 8 / 8 / 4 5 /8 4 5 /8 3 /8 3 /8 3 3 2 3 2 3 EJB24240 3 /8 4 3 4 3 8 / 8 / 4 5 /8 4 5 /8 3 /8 3 /8 3 3 2 3 2 3 EJB3208 4 3 4 / 3 8 / 3 5 /8 8 / 3 / 5 3 2 5 3 3 5 /8 /2 3 /8 EJB3808 5 /2 4 / 4 / 8 / 8 / 4 5 /8 5 3 3 5 3 2 3 5 /8 2 /2 3 /8 2 EJB380 /2 4 3 4 3 8 / 8 / 8 / 5 3 3 5 3 2 3 5 /8 2 /2 3 /8 2 EJB32408 4 3 4 3 / 8 / 8 / 8 / 5 3 4 5 /8 5 3 3 /8 5 /8 3 3 /8 2 3 Conduit seals are required in all conduit entrances for Class I, Division, Group B hazardous areas, and for EJB3208, EJB3808, EJB380, EJB32408, and all Style D enclosures when used in Class I, Division, Group C hazardous areas. For other sealing requirements, consult the National Electrical Code*. Where standard arrangements are not adequate, special drilling and tapping can be ordered, or instructions can be provided for field drilling and tapping. Breathers and drains must be ordered separately. Maximum trade size for Group B application is 4". Table 3 Symbols for Openings Conduit Size Drilled and Tapped Hole Symbol /2 A 3 B C E /2 F 2 G 2 /2 H 3 J 3 /2 K 4 L 5 M Maximum trade size for Group B applications is 4". *Top and bottom are longer dimensions on enclosures which are not square. N Spacing dimensions for Group B boxes are based on use of EYS-0 sealing fitting in conduit. None 0 For conduit liner ordering information, see page 850. 23

In Inches: A B C D E Table 4 Outside Cat. # Diagram aa bb Mtg. Hole ww xx yy zz Net Weight (lbs.) w/ Cover EJB00404 8 /32 0 /32 EJB08004 0 5 /32 2 5 /32 EJB0800 0 5 /32 2 5 /32 EJB08080 2 5 /32 2 5 /32 EJB20804 2 /2 /2 EJB0404 8 /2 20 /2 EJB00404 SA 8 A, /32 0 /32 EJB08004 SA 0 B, /32 2 5 /32 EJB0800 SA 0 D /32 2 5 /32 EJB08080 SA 2 5 /32 2 5 /32 EJB2004 SA 0 /2 /2 EJB20804 SA 2 /2 /2 EJB20808 SA 2 /2 /2 EJB0404 SA 8 /2 20 /2 EJB0008 SA 4 2 /32 4 2 /32 EJB400 SA 4 2 /32 8 2 /32 / 8 3 /8 5 /8 43 / 0 25 /32 3 / /8 4 / 0 25 /32 8 3 / /8 84 / 2 25 /32 8 /32 /8 8 / 2 3 / 3 /8 /8 03 / 8 3 / 5 /32 5 /8 8 / 8 3 /8 5 /8 / 0 25 /32 3 / /8 24 / 0 25 /32 8 3 / /8 32 / 2 25 /32 8 /32 /8 3 / 0 3 / 3 / /8 32 / 2 3 /8 3 /8 /8 3 / 2 3 / 0 3 /8 /8 5 / 8 3 / 5 /32 5 /8 33 / 4 /8 0 3 /8 3 /8 5 / 4 /8 8 5 /32 3 3 /8 EJB0080 3 /32 5 /32 EJB2204 / / EJB220 / / EJB2208 / / EJB0 2 3 / 2 3 / EJB08 2 3 / 2 3 / EJB820 C / 23 5 / EJB8208 and / 23 5 / EJB24208 E / 2 / EJB2420 / 2 / EJB24808 23 / 2 5 /8 EJB242408 2 / 2 / EJB24240 2 / 2 / EJB3208 / 4 / EJB3808 23 5 / 4 5 / EJB380 23 5 / 4 5 / EJB32408 30 3 / 42 3 / For conduit liner ordering information, see page 850. / 2 8 / 5 /2 0 / /8 3 / 5 /2 5 /8 0 / /8 8 /8 5 /2 5 /8 0 / /8 0 /8 5 /2 5 /8 80 / 20 /8 8 /8 /2 /8 03 / 20 /8 0 /8 /2 /8 3 / /8 8 /8 /2 5 /8 0 / /8 0 /8 /2 5 /8 0 / /8 3 /2 5 5 /8 4 / /8 3 3 /2 5 5 /8 0 / 23 /2 2 2 /8 243 / 2 /2 2 5 / 2 /8 2 / 2 /2 4 5 / 2 /8 322 / /8 / 2 /2 5 /8 85 / 23 /2 2 / 28 2 /8 35 / 23 3 4 28 2 /8 3 / 3 2 5 /8 28 2 /2 5 24

EJB Custom-Built Control Panels Globally Certified Individually Customized Ordering Information Building a Custom Solution Ordering and receiving Cooper Crouse-Hinds EJB Custom-Built Control Panels is now easier and faster than ever. Follow the steps below, fill out a separate order form for each panel, and fax it to your local Cooper Crouse-Hinds Distributor. It s as simple as that! Easy Five Step Ordering Process: Specify cover openings and devices. 2 Specify conduit openings. 3 Determine device arrangement. 4 Specify device location. 5 Specify legend and nameplates. Step Specify the openings required for the cover of the enclosure. Indicate in Section of the order form the combination of devices, openings without devices, and windows required. Total the number of device openings required based on the devices, openings and windows specified in Section. Using Table, you can determine the smallest size enclosure required based upon the total number of devices/openings and the number of devices a window requires. (NOTE: The actual size of your custom panel enclosure may change based on the number and size of your entry requirements.) TABLE Total # of Device Openings Available DEVICE AND WINDOW INFORMATION Device Layout EJB Enclosure Catalog Number 3 3 EJB0080 4 4 EJB2204 4 4 EJB220 4 4 EJB2208 3 EJB0 3 EJB08 24 4 EJB820 24 4 EJB8208 3 4 EJB24208 3 4 EJB2420 54 54 EJB24808 EJB2480 8 EJB242408 8 EJB24240 52 3 4 EJB3208 8 8 3 3 EJB3808 EJB380 3 EJB32408 Requires same area as 2 devices. May be installed in all boxes. EJB Size W GUB008 Symbol W 4-3" dia. viewing area SIZE REQUIREMENTS Max. No. Windows 2204 to 8208 24208 to 32408 2 2