Selecting & Integrating Safety Exhaust Valves White Paper

Similar documents
What you Need to Know About Safety Exhaust Valves White Paper

Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Modern Safety Systems and Advanced Fluid Power Solutions

Safety Exhaust Valve Integration Guide

NHP SAFETY REFERENCE GUIDE

Session Four Applying functional safety to machine interlock guards

4 Redundant Control System

Redundant Control System

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

WHITE PAPER. SVM4001 Series standstill monitor. Stop everything! Standstill monitors add sensorless safety features to motor-driven machinery

Crane and Hoist Solution Guide. The Advantage of Experience

NHP SAFETY REFERENCE GUIDE

Hinge Wing Safety Interlock Switches

Safety Sensor CSS 180 Product Information

Advanced Electromechanical Actuation Components to Solutions Systems

Battery Technology for Data Centers and Network Rooms: Site Planning

SECONDS CAN COST MILLIONS

Maintenance Instructions & Parts List

Safety Application Note

Sense7-series Non-contact coded safety switch

MARINE. Decrease fuel consumption and emissions with shaft generators and drives

Installation Instructions

Brochure. Arc Guard System TVOC-2 A protection device for reliable safety

DKR Intelligent Digital AC Vector Drives 35 to 330 hp (26 to 245 kw)

Laird Engineered Thermal Systems Application Note. Thermoelectric Modules and Assemblies for Medical Laser Cooling Applications

Sliding Door Automation For escape routes and emergency exit

UNI EN ISO EN

SECTION B: SYSTEM OPERATING COMPONENTS

Technical Article. ISO26262: ams deploys unique technology to meet every new safety requirement. Roland Einspieler

Focus Area Level Report Including Knowledge and Skills, and Performance Indicators

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

A. General Specifications. B. Dimensional Layout. BTU International Specification: Model 150Nz12 Reflow Solder System Date: 11/05/09 Page: 1/6

Improving predictive maintenance with oil condition monitoring.


EZS. Motorized Linear Slides. Series. RoHS-Compliant

AUTOMATION AND CONTROL TRADE 19 TAR SANDS

* Evaluated by TÜV Rheinland (Report No. 968/FSP /16) in accordance with ISO and ISO

Turbine Trip Block. State of the Art Protection System APPLICATION SUMMARY INTRODUCTION TO FSD/IMI DESIGN AND

FlexFast Welder Ver. 3.0

ABB JOKAB SAFETY Protecting your valuable personnel and your company bottom line

ABB JOKAB SAFETY Products. Material handling industries Machine safeguarding products

Dual Power. Protection. Protection

SECTION B1: MACHINE COMPONENTS

Introduction to Robotic Parking Systems

Optimizing Battery Accuracy for EVs and HEVs

Applications of Pneumatics and Hydraulics

UPS Ratings-Not so Apparent

RF Control of Pneumatic Actuators

Standby Power Systems

Customized Solutions. Safety & Reliability Stainless steel 316 products

CAUTION-ELECTRICALLY OPERATED PRODUCT

SHOULDER TO SHOULDER. The case for paralleling generator sets

BREAKER FAILURE PROTECTION

Overview. Battery Monitoring

LA Motor Protection. A South African Company to be Proud of

TRANSMISSION PLANNING CRITERIA

Pedals for commercial and special-purpose vehicles. Robust Electronically controlled Flexible installation.

Pressure Control SYSTEMS

VEKTEK PARTS LIST THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL AT REVISION C AND LATER REVISIONS.

SUBJECT: Automatic Stability Control with Traction Control System (ASC+T)

Auxiliary Power Systems. Delivering the power as you need

Water Valve Shutoff. WVS Water Valve Shutoff

Direct Communication Module

MARITIME AFTERNOON. Torben Ole Andersen. June 14, 2017 Aalborg University, Denmark

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

MICROINVERTER ANALYSIS

1. INTRODUCTION. Anti-lock Braking System

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

MASTERYS IP+ 10 to 80 kva

Steer-by-Wire Systems with Integrated Torque Feedback Improve Steering Performance and Reduce Cost

Control block VOFA with safety function

TIME REQUIREMENT GUIDE (TRG)

ABB JOKAB SAFETY Products. Food and beverage industries Machine safeguarding solutions

Exhaust System Bypass Valves and Exhaust Valve Bypass Controller

Modernization upgrade packages for KONE MonoSpace elevator

Easy Multifunctional Safe

ECONOMISER SERIES E2T USER MANUAL

AP1000 European 7. Instrumentation and Controls Design Control Document

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Delivering higher efficiency in motor drive applications

GET OFF THE DOWNTIME ROLLER COASTER.

EPA Tier 4 and the Electric Power Industry

CIMAC Position Paper

Grid-Friendly Utility-Scale PV Plants

TERMINATOR User Manual

METAL STAMPING & FORMING EQUIPMENT. Straight Side. Mechanical Presses tons

Cost Affective Dockside Crane Retrofit Utilizing Existing SCR s

White Paper. Safe collaboration with ABB robots Electronic Position Switch and SafeMove

The Tanktwo String Battery for Electric Cars

Relay Driver Applications Guide

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Hydraulic Railcar Maintenance Equipment

MID TONNAGE. Van Dorn Caliber

Transcription:

Selecting & Integrating Exhaust Valves White Paper

Selecting and Integrating Exhaust Valves Linda Caron Global Product Manager, Factory Automation Parker Hannifin Corporation Today, exhaust valves are designed to ensure fail-safe operation and ensure rapid exhaust of any pneumatic equipment on an e-stop, and they are available in single-channel or two-channel (redundant) configurations. High-risk safety applications (based on a risk assessment in accordance with ISO 13849-1) employ safety exhaust valves that are integrated into a control circuit and monitored with a safety-rated device. In industrial environments, pneumatic lines can pose significant hazards to workers and associated equipment; these hazards are associated with both the pneumatic lines themselves and the moving components they operate. Systems that minimize these hazards have been developed to comply with two ISO safety standards, EN ISO 13849 and ISO 13118:2000, which mandate the dissipation of pneumatic energy to prevent unintended startup or movement in a machine. As manufacturers increase their focus on equipment safety, design engineers need a clear understanding of these standards and how to comply with the required safety levels. Adding a pneumatic safety exhaust valve into an air preparation system offers one simple, cost-effective way to accomplish this. Traditionally, the air trapped in the pneumatic lines had to be exhausted with pneumatic circuits with two valves to provide redundant safety. The downsides of this pneumatic circuit approach included the need to purchase the valves and other peripherals, and the plumbing and space needed to ensure safe evacuation of the machinery; unfortunately, this traditional approach was also relatively slow to exhaust. Today, a handful of manufacturers have combined this pneumatic circuit into a compact product called a safety exhaust valve. These valves allow users to shut off the pneumatic energy safely and reliably, stopping the flow of compressed air to the machine and allowing the downstream pressure to exhaust out. For example, the safety function can be activated when operators are reaching into hazardous areas or during an e-stop condition. (Architecture for redundant two channel safety valve s)

Internally or Externally Monitored exhaust valves are available. Let s review the advantages and disadvantages of each. Internally monitored safety exhaust valves tend to be more expensive than the externally monitored type because the monitoring logic is programmed inside the valves, using either electric or pneumatic logic. Although internally monitored valves are easier to integrate, they respond more slowly and typically deliver a reduced service life in terms of both switching cycles (B10 values) and Mean Time to dangerous failure (MTTFd). This reduced service life is the result of using on-board electronics that are contained and give off heat, so they tend to fail earlier than mechanical components. Internal diagnostics add further complexity because they must be run each time the valve pressurizes, which results in a longer start time and, therefore, a Integrated Guidance Cat 4, PL e longer cycle time. If the machine s internally monitored valves are not grounded, there may be further problems caused by electromagnetic interference (EMI). Just as with laptops, internally monitored valves must be shut down and restarted properly or they will lock out the machine, which makes resetting and repressurizing the machine a challenge. Externally monitored safety exhaust valves are less expensive than internally monitored ones simply because the user programs the monitoring logic into the programmable safety device or standard programmable logic controller (PLC). Some Exhaust Valve manufacturers offer function blocks to help make this programming easier. This reduces the internal complexity of the product, making the valves easier to integrate and restart; it also provides a higher B10 value for longer service life. The disadvantage is the necessity of doing the monitoring logic programming and taking control, but there is significant cost savings with greater functionality and longer life, which many engineers feel far outweigh the work of programming. The purpose of monitoring is to ensure that faults are not present in the control circuit (such as a wiring short) and that the safety exhaust valve is operating correctly. Monitoring a safety product requires a safety-rated device and a means of programming. This can be accomplished in several ways via the products integration. Cat 3, PL d relay PLC relay PLC for external monitoring Reset button Reset button Integration for Cat 4, P/L e provides the highest level of safety. The safest (but costlier) way to do this is to use a safe PLC that is fully programmable and offers independent processors to manage the two (redundant) channels of monitoring. By selecting the correct safety devices and with proper integration this arrangement allows you to achieve up to a Category 4, performance level e safety rating. Those who need a less expensive alternative can opt for a programmable safety relay that still supports achieving the highest safety level of Category 4, PL e. Integration for Cat 3, P/L d A redundant control circuit with the lowest cost can be built using a standard PLC and a safety relay. While this allows for safe monitoring, it will not meet the Category 4 criteria; the maximum rating achievable would be Category 3, PL d. Valve integration is critical because a safety valve rated for Category 4 and a safety device rated for Category 4 will not always produce a Category 4 safe solution. The secret to achieving the desired Category and Performance Level is in the design of the safety exhaust valve and its MTTF d, the diagnostic coverage of the control system and the proper integration and wiring of the monitoring and control system.

Exhaust Valve 5 Key Selection Guidelines Several important questions should be considered when specifying a safety exhaust valve: 1 Measure the Exhaust Time in Faulted Condition Take the time to understand the worst-case scenario; when a safety valve is in faulted condition, standard exhaust times (assuming normal stop) do not apply. In this situation there is a failure in the valve or control system and the exhaust flow may be restricted thereby increasing exhaust time. Switching Time is Important 2 The faster a machine can stop, the closer to the machine that the guards, light curtains, or other presence-sensing devices can be installed. Your switching time off impacts your calculations for safe stopping distance. Your switching time on impacts the lag time to fill the machine. Product Design 3 A series-parallel flow design (as shown) for safety exhaust valves incorporates the best of both Parallel to Series Parallel series and parallel arrangements to ensure that both valve elements (redundant design) must shift to supply air downstream and if either valve element were to be out of position with the other, the downstream air will be dumped to exhaust in parallel. This arrangement allows higher exhaust flow capability and ensures very low residual pressure during a fault, eliminating the danger of residual energy making its way into the machine. Consequently, if two exhaust valves are used in series, the air supply to the first valve flows through to the second valve and then downstream. When in exhaust mode this design flows most of the exhaust through the second valve creating a lag in exhaust time. Know the B10 Value 4 The valve s B10 value is its life expectancy in switching cycles and is based on B10 testing (the point at which 10 percent of a sample lot has failed). It s an important consideration when determining the MTTF d. The higher the quality of the components is, the longer the B10 life of the machine into which they are built will be. This is an important consideration for Category 4 applications where a high diagnostic coverage is needed. Monitoring To achieve the 5 highest level of diagnostic coverage, it s critical to employ all the best aspects of safety circuit architecture redundancy (dual channel circuits) and monitoring to detect faults or failures in control systems and check for short circuit faults. The monitoring portion of the safety system must check to see if both sides of the valve are shifting together every time. This is generally done with most versions of safety relays and safety PLCs that can also perform pulse test monitoring. These types of safety relays and safety PLCs make for very reliable systems with high diagnostic coverage especially, short circuit faults in dual channel systems. The use of sophisticated controls and monitoring ensures the valve is functional. Conclusion allows no room for error. If the risk assessment requires a safety rating of PL c or higher for the pneumatic system, a dual redundant safety exhaust valve offers a simple-to-implement and cost-effective way to attain the required safety level. Take the time necessary to find a safe exhaust valve that has been designed to fit well into both mid- and high-level safety circuits to ensure the machine is properly protected. Additional integration details are available for Parker products at www.parker.com/pdn/safetyvalve 2018 Parker Hannifin Corporation Parker Hannifin Corporation Pneumatic Division 8676 E. M89 P.O. Box 901 Richland, MI 49083 USA Tel: 269 629 5000 Fax: 269 629 5385 PDNWP-001 February 16, 2018 Applications Engineering Phone: 877 321 4PDN Option #2 E-mail: pdnapps@parker.com Customer Support Phone: 877 321 4PDN Option #1 E-mail: pdncustsvc@parker.com Web site: www.parker.com/pneumatics www.parker.com/pdn/safetyvalve

Hydraulics Industrial Mobile Marine Automation Pneumatics Electronics Robotics Electromechanical Systems Fluid Connectors Instrumentation Industrial Engineered Systems and Solutions Factory Authorized Repair Service Installation and Field Service Vendor Managed Inventory Services NEW JERSEY Mahwah/Morse Fluid Technologies 305 Island Road, Mahwah, NJ 07430 P: 800.382.2823 24-Hour Emergency Service: 800.305.0854 Maple Shade 612 East Woodlawn Avenue, Maple Shade, NJ 08052 P: 800.526.270 24-Hour Emergency Service: 877.467.3376 Vineland 205C South Delsea Drive, Vineland, NJ 08360 P: 888.492.9869 24-Hour Emergency Service: 888.625.6290 NEW YORK Kingston 615 State Route 28, Kingston, NY 12401 P: 888.366.3358 24-Hour Emergency Service: 800.291-9341 PENNSYLVANIA Montoursville 1210 Broad Street, Montoursville, PA 17754 P: 877.280.084 24-Hour Emergency Service: 877.276.6423 Pittston 119 Brown Street, Pittston, PA 18640 P: 570.883.1009 24-Hour Emergency Service: 800.775.4906 Sewickley 1712 Mt. Nebo Road, Sewickley, PA 15143 P: 877.736.1613 Sinking Spring, Reading 4704 Penn Avenue, Sinking Spring, PA 19608 P: 800.347.8534 24-Hour Emergency Service: 888.480.1419 Lancaster 1350 Harrisburg Pike, Lancaster, PA 17601 P: 800.541.0165 24-Hour Emergency Service: 800.807.1062 York 15 Flour Mill Road West, York, PA 17406 P: 717.849.034 24-Hour Emergency Service: 877.435.7347 WEST VIRGINIA Fluid Component Services 3256 US Route 60, Ona, WV 25545 P: 740.894.3139 www.rg-group.com toll-free 877.870.2692 email customer.service@rg-group.com Innovative Motion Control and Fluid Handling Products and Solutions Fluid Component Services Division I ParkerStore Hose & Fitting Service I Marine Systems I Morse Fluid Technologies Division