Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Similar documents
Users Manual. Phase Rotation Indicator

Phase Sequence Tester

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

362 Clamp Meter. Users Manual

Users Manual. MegOhmMeter

365 Detachable Jaw True-rms Clamp Meter

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

362 Clamp Meter. Users Manual

373 Clamp Meter. Users Manual

DIGITAL RCD(ELCB) TESTER

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Non-Contact Phase Rotation Tester

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Digital Multimeter User's Manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

302+/303 Clamp Meter. Users Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

323/324/325 Clamp Meter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Non-Contact Phase Rotation Tester

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

WENS30C Loop Calibrator

Volt/mA Calibrator. Manual

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

KMP Insulation-Continuity Tester. Users Manual

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Mini Multimeter with Non-Contact Voltage Detector (NCV)

OPERATING INSTRUCTION

OPERATING INSTRUCTION

Visit us at

3 PHASE TESTER & MOTOR ROTATION TESTER

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

i400s Calibration Information Introduction

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

USER MANUAL. Insulation Tester + DMM. Model MG320

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

Model UT602/603: OPERATING MANUAL

OPERATING INSTRUCTION

80 Series V Digital Multimeter Safety Information

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

OPERATING INSTRUCTIONS

Model UT601: OPERATING MANUAL

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Users Manual. Airflow Meter

Calibration Manual. Detachable Jaw True-rms Clamp Meter

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Dawson DDM190D. Digital Multimeter User s Manual

190M. Medical ScopeMeter. Safety Information

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

2-Year Limited Warranty. See the Users Manual for the full warranty.

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Safety design conforming to the following provisions

BM kv Digital Insulation Tester USER MANUAL

T2 Tester. Calibration Information. Introduction. Safety Information

707Ex. Users Manual. ma Calibrator

1.Safe testing IMPORTANT:

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PY-11 Voltage & Continuity Tester

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

True RMS Autoranging Multimeter

Rental Industry Safety Tester Safe Check 5s

Instruction Manual IVT-10 / IVT-20 Voltage Tester

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Autoranging Multimeter

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Autoranging Industrial Multimeter

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

5.2 PRE-OPERATION PROCEDURE WARRANTY

233 True-rms Remote Display Digital Multimeter Safety Information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

i3000s/i2000 Flex AC Current Probe

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Switching DC Power Supply

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Cable Length Meter INSTRUCTION MANUAL

3-Year Limited Warranty. See the Users Manual for the full warranty.

Safety design conforming to the following provisions

Digital/Analog Megohmmeter Model 1026

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

716 Pressure Calibrator

INSTRUCTION MANUAL DM5B Fax: (503)

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Transcription:

MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine motor-rotation direction. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery Users Manual If an item is damaged or missing, contact the place of purchase immediately. Safety Information Caution identifies conditions and actions that may damage the apparatus. Warning identifies conditions and actions that pose hazard(s) to the user. Read First: Safety Information To avoid possible electric shock or fire, do the following: Read the following safety information carefully before using or servicing the instrument. Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and injury Use of instrument in a manner not specified by the manufacturer may impair safety features/protection provided by the equipment. Avoid working alone. Inspect the test leads for damaged insulation or exposed metal. Check test lead continuity. Damaged leads must be replaced. Do not use the apparatus if it looks damaged. Be careful when working above 30 V ac rms, 42 V ac peak and 60 V dc. Such voltages pose a shock hazard. When using the probes, keep fingers away from probe contacts. Keep fingers behind the finger guards on the probes. Measurements can be adversely affected by impedances of additional operating circuits connected in parallel or by transient currents. Verify operation on a known source prior to measuring hazardous voltages (voltages above 30 V ac rms, 42 V ac peak and 60 V dc). Do not use the apparatus with any of the parts removed. Do not use the apparatus around explosive gas, vapor, or dust. Disconnect the test leads from power sources and the apparatus before changing the battery.

Do not use the apparatus in a wet environment. Symbols The following symbols appear on the Motor and Phase Rotation Indicator or in this manual. Table 1. Symbols Attention! Dangerous Voltage! Ground AC DC Low Battery Fuse European union directives Double insulation Elements of the apparatus Indicators, buttons, and jacks are shown in Figure 1. Test lead input jack L1 L2 L3 Indicators Clockwise Rotation LED ON/OFF button Explain Faceplat Orientation Symbol ON/OFF Indicator Counter-Clock wise Rotation LCD Indicator Figure 1. Using the Motor & Phase Rotation Indicator Determine Rotary Field Direction To determine the rotary field direction: 1. Connect one end of the test leads to the apparatus Make sure the L1, L2, and L3 test leads are connected to the corresponding input jacks. 2. Connect the test probes to the other end of the test leads. 3. Connect the test probes to the three mains phases. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Either the Clockwise or Counter Clockwise Rotary indicator illuminates showing the

type of rotary field direction present. Warning The rotary indicator lights even if the neutral conductor, N, is connected instead of L1, L2, or L3. Refer to Figure 2 (also shown on the face of the apparatus) for more information. Figure 2. Phase Indication Table (shown on the face of the apparatus) Non-Contact Rotary Field Indication For non-contact rotary field indication: 1. Disconnect all test leads from the apparatus 2. Position the Indicator on the motor so that it is parallel to the length of the motor shaft. The Indicator should be one inch or closer to the motor. See Figure 3. 3. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Either the Clockwise or Counter Clockwise Rotary indicator illuminates showing the type of rotary field direction present. Note The Indicator will not operate with engines controlled by frequency converters. The bottom of the apparatus should be oriented towards the drive shaft. See the OrientationSymbol on the apparatus. Figure 3. Motor Rotation See Table 2 for the minimum motor diameter and number of pole pair to obtain a reliable

test result. Table 2. Reliable Motor Test Requirements Determine the Motor Connection 1. Connect one end of the test leads to the apparatus. Make sure the L1, L2, and L3 test leadsare connected to the corresponding jack. 2. Connect the alligator clamps to the other end of the test leads. 3. Connect the alligator clamps to the motor connections, L1 to U, L2 to V, L3 to W. 4. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. 5. Turn the motor shaft half a revolution towards the right. Note The bottom of the apparatus should be oriented towards the drive shaft. See the Orientation Symbol on the apparatus Either the Clockwise or Counter Clockwise Rotary indicator illuminates showing the type of rotary field direction present. Magnetic Field Detection To detect a magnetic field, place the apparatus to a solenoid valve. A magnetic field is present if either the Clockwise or the Counter Clockwise Rotary indicator illuminate. Maintaining the apparatus This section provides basic maintenance information. Caution To avoid damaging the apparatus: Do not attempt to repair or service the apparatus unless qualified to do so. Make sure that the relevant calibration, performance test, and serviceinformation is being used. Cleaning Periodically wipe the case with a damp cloth and mild detergent. Clean only with soap and water and remove any residue afterwards. Caution To avoid damaging the apparatus: Do not use abrasives or solvents. Abrasives or solvents will damage the apparatus case. Prior to cleaning, remove test leads from the apparatus. Replacing and Disposing of the Batteries Warning To avoid electric shock, disconnect the test leads from the source before opening the apparatus for

battery replacement. Note The apparatus contains alkaline batteries. Do not dispose of these batteries with other solid waste. Used batteries should be disposed of by a qualified recycler or hazardous materials handler. The apparatus uses a 9 V battery (supplied). To replace the battery, follow these steps and refer to Figure 4: 1. Disconnect test leads from any power source. 2. Remove the holster. 3. Place the apparatus face down on a nonabrasive surface and loosen the battery-door screw with a flat-blade screwdriver. 4. Lift the battery access lid away from the apparatus. 5. Replace the battery as shown in Figure 4. Observe the battery polarity shown in the battery compartment. 6. Secure the battery access lid back in position with the screw. 7. Place the apparatus back in the holster. Figure 4. Battery Replacement Specifications Environmental Operating Temperature 0 C to +40 C Operating Altitude 2000 m Pollution Degree 2 Type of Protection IP 40 Mechanical Specifications Size 124 x 61 x 27 mm (4.9 x 2.4 x 1.1 in)

Weight 150 g (0.3 lbs) Humidity 15 % to 80 % Safety Specifications Electrical Safety Meets DIN VDE 0411, IEC 61010 DIN, VDE 0413-7, EN 61557-7, IEC 61557-7 Maximum Operating Voltage (Ume) 400 V AC for all ranges Protection Level CAT III, 300 V Electrical Specifications Battery 6F22/9V Current Consumption max 20 ma Battery Life minimum 1 year for average use Determine Rotary Field Direction Nominal Voltage Rotary Direction 1 to 400 V AC Nominal Voltage Phase Indication 120 to 400 V AC Frequency Range (fn) 2 to 400 Hz Test Currents (In per phase) less than 3.5 ma Non-Contact Rotary Field Indication Frequency Range (fn) 2 to 400 Hz Determine the Motor Connection Nominal Test Voltage (Ume) 1 to 400 V AC Nominal Test Currents (In per phase) less than 3.5 ma Frequency Range (fn) 2 to 400 Hz