SSV2BR INSTRUCTIONS INSTALLATION INSTRUCTIONS

Similar documents
INSTRUCTION MANUAL. Wireless Level Indicator

Reverse Polarity MANUAL. Surechlor S3500

PHOTON ONE - SOLAR POWERED AWNING MOTOR

Operators Guide: RoboSign Stop/Go Traffic Control System

INSTRUCTIONS Solar Motion-Activated Wedge Light

OPERATING INSTRUCTIONS Solar Motion-Activated Wedge Light

Operators Guide: RoboSign Stop/Go Traffic Control System

VERT 1 VERTICAL TAKE OFF / LANDING RC PLANE

Care and use guide. Contents. page

MAESTRO WIRELESS. You now need to wire your receiver to your display unit. RED GREEN

TC62D Installation Instructions

AVIATOR REMOTE CONTROL HELICOPTER

EWC-350/850. Commercial model - indoor/outdoor installation Operation Manual. H2oEliteLabs.com

Solar Dock Post Lites

Solar Differential Temperature Controller Model DTC-D

120 LED DUAL HEAD SOLAR MOTION LIGHT

easyflow-vs Variable Speed Peristaltic Dosing Pump

THUNDERBIRD Solar Electric Fence Energisers. S20 / S20B / S40 / S40B / S79 / S150

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00

N-BUGGY OPERATION MANUAL. Hayes Spraying ABN Troy Drive PO Box 515 GOONDIWINDI QLD 4390

INSTALLATION / MAINTENANCE

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

Recommended Tools: Phillips Screwdriver, 7mm Open End Wrench, Soldering Iron & Solder (for solar panel)

MotorScrubber MS2000S/M/L Instruction Manual

MotorScrubber MS2000S/M/L Instruction Manual

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

Installation Instructions

Installation & Operations Manual

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

INSTALLATION AND OPERATION MANUAL

SAFETY WARNING Please read these before operating your Sky Vector

Solar Powered Wireless Temperature Station & Sensor

EMF INSTALLATION & OWNER S MANUAL ULTRA COMPACT NICHE LIGHT FOR FIBREGLASS POOLS STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

Recommended Tools: Phillips Screwdriver, 7mm Open End Wrench, Soldering Iron & Solder (for solar panel)

Pivotell Mark 3/11 Automatic Pill Dispenser Instructions

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

A S S E M B L Y G U I D E

The breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece.

Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

Bluefin Led Underwater lights.

INSTALLATION & OPERATION MANUAL

Solar Gazebo Accent Lighting

SOLAR CHARGE CONTROLLER

Dankoff LCB Solar Pump & Fan Controller. INSTRUCTIONS For INSTALLATION and OPERATION

Product features and decoration may vary from the photograph above.

Aquarium Bouncer. Model Number: 79030

FIRE HYDRANT/HOSEREEL PORTABLE TESTER

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

CAUTION: Surfaces may become hot and cause burns if

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro

Openers ROLLING AND OVERHEAD SECTIONAL GARAGE DOORS

INSTALLATION INSTRUCTIONS

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

LI-2B Installation Manual

Bluefin Led Underwater lights.

Installation Manual. Opal Solar QSA Series

Modifying the exterior lighting of the Ram truck

J5242.

The Traveler Series: Wanderer

12V DC MOTORISED OPENER FOR SWING GATES Section Table of Contents Page

SPLIT SOLAR HEATER SWSP-200 SWSP-300

User s Manual. Spin & Learn Adventure Globe VTech Printed in China

Special Features. Specifications Motor Types: Sensored Motor Limit: 2.5T (on 2S) Input Voltage: 2-3S LiPo Direction: Forward, Brake, Reverse

channel damage the internal components and the weight may break the internal wiring or flexible strip.

Contents INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...

FHC-1D user manual. Features

English. Fitting Instructions: Street Triple Rx, Street Triple from VIN and Street Triple R from VIN A , A and A

Atom Bait Boat User Guide

Thermometer models / 00831A

DCC-3000 Climate Control for Vintage Air GEN-IV systems

INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only)

GP-MPPT-R. User Manual GoPower!

Tyre Pressure Monitoring System TyrePal Solar. Innovative safety solutions for your peace of mind

CONTENTS INTRODUCTION

Folding Scooter. User Manual

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100

MCL-3000 SERIES AIR PRESSURE PART# MCL-3K-A

STRX-9 100% TAKE CONTROL INSTRUCTION MANUAL READY-TO-RUN. w/ Adult Supervision

Twelve Unit Rapid Charger

High Idle Kit Dodge Cummins (24 valve) Dodge Cummins (with APPS on motor) PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

MAESTRO INSTALLATION. Determine where you are going to locate both the rooftop sensors and the read-out.

User Manual 200Ah INVERTER / CHARGER

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied:

PROwatt 150 DC to AC Power Inverter. Owner s Guide

The Renogy Firefly. 20W Portable Solar System E. Philadelphia St., Ontario CA

Combine Cover Manual

ASSEMBLY & OPERATING INSTRUCTIONS

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

11ft Round Solar Offset Umbrella with Tube Lights

PURE SINE WAVE DC TO AC POWER INVERTER

PRO Dimmer INSTRUCTION MANUAL

ELECTRIC BICYCLE OWNER S MANUAL

HPP1 MK5 Owner s Manual

LIGHTNING PROTECTION UNIT (LPU)

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

LV101 DCC Power Station

Transcription:

SSV2BR INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER MOUNTING: Find a suitable location to mount the control box. Ideally, as with all pool equipment it should be installed out of direct weather and no closer than 3m from the waters edge. Lift up the two mounting tabs and use two appropriate screws to mount the control box to the wall, keeping in mind that the power cable is 1.8m long and should be plugged directly into a general power outlet, not into extension leads. POOL SENSOR: For stand alone systems with separate suction and return, the pool sensor must be fitted into the suction line of the solar pump preferably in a position out of direct sunlight. It is recommended that a 14.5mm hole be drilled in the PVC pipe; this can be carried out using a 14.5mm drill-bit spinning in a counter clockwise direction to minimise the chance of shattering pipe. The sensor plug is to be fitted to the left hand socket. TRANSMITTER: Mount the transmitter box in an easy access location, normally next to the pipes running to the roof as system batteries will require replacement at some stage. On initial installation remove the lid of the box and install the supplied AA alkaline batteries, ensuring the batteries are located correctly. Do not fit transmitter on the roof. TEST MODE: At the opposite side of the battery holder in the transmitter box there is a jumper pin marked J1. By moving the jumper from the RUN to the TEST position the transmitter will continuously send the roof temperature to the SSV2BR. Use the select button on the SSV2BR to read the ROOF temperature, a current roof temperature should be seen or a fault code. If a reception cannot be received make sure that the batteries are in good order and in the correct way and that the code switches inside the SSV2BR and the Transmitter are matched. Due to the possibility of reception ghosting and electrical interference the Transmitter may be required to be moved to an alternative position, this may be as little as two meters and keep in mind that the roof sensor cable may be extended 20ms if required. The main SSV2BR controller should be mounted away from other electrical appliances as far as possible to reduce the chance of interference. If the unit is to be installed in a metal shed there may be reception issues and the controller may need to be optioned with a remote antenna or moved outside. BATTERIES: Replacement AA batteries must be alkaline quality or better, rechargeable batteries are not recommended. Do not mix battery types.

ROOF SENSOR: The roof sensor end must be fitted in a small piece of solar collector or equivalent and attached to the roof. Best locations are within arms length of the gutters edge of the house or shed as long as the sensor end is not shaded and is on a roof of similar aspect of the main collector run, it must not be fitted on top of the solar collector. Keep in mind that it is of the utmost importance to keep the roof sensor as short as possible as this will assist in the longevity of the sensor and controller in the event of electrical storm activity and power surges. Sensor cables must not be run parallel to power cables and run lengths should be less than 50m. Cable ties should be used to fasten the sensor cable to the cold water inlet pipe making sure that the ties are away from PVC fittings. Cable ties should be tightened firm but not too tight to damage the cable. If the cable is to be run under ground a conduit must be used to protect the wire and there is to be no cable joins within, ends of conduit must be sealed to prevent water ingress. Any excess cable should be removed and re-fitted ensuring that the wire ends are tinned with solder. The sensor plug is to be fitted to the right hand socket. NOTES: All excess cable must be removed; coils of cable are not permitted under any circumstances. If the cable is to be extended with non genuine cable a size of 14/020 should be used. Any cable joins must be soldered and this includes where the cable enters the terminal block at the case base. Heat shrink is to be used over soldered joints to eliminate moisture ingress. Cable polarity must be observed as incorrect polarity will show an error as stated in fault diagnosis. Once cables have been correctly fitted the unit can be turned on.

OPERATING INSTRUCTIONS AUTO MODE: The SSV2BR should be left in AUTO mode for the pool swimming season; this will allow the solar pump to switch on and off as required. To change the desired pool limit, simply press and hold the SET TEMPERATURE up or down button until the desired temperature is achieved, the display will scroll from 20 through 40 in a continuing loop or vice versa. When idol the SSV2BR will show the pool temperature then flash the limit setting with the LIMIT light; the PUMP/MAN light will be on when solar gain is available. PUMP/MAN: To over-ride the boost pump press the MODE button until the PUMP/MAN light is illuminated, after 3 seconds the light will flash and turn the pump on if it was off and off if it was on. After 30 minutes the unit will return to AUTO mode. ROOF: To display the roof temperature press the MODE button until the ROOF light is illuminated. The roof temperature will be displayed for 3 minutes and return to AUTO mode. The ROOF indicator will give 4 quick flashes when a signal is received from the transmitter. WINTER MODE: The SSV2BR has a Winter Mode that turns the solar pump on for 3 minutes every 24 hours to assist in the systems off-season maintenance. Press the MODE button until the WINTER light is illuminated, the display will go blank, the PUMP/MAN light will be on and the boost pump will run for three minutes. This event will happen every day at the same time that winter mode was selected. If the power is interrupted or turned off during winter mode, the SSV2BR will continue to count time accurately for up to 7 days. TROPICAL MODE: Tropical mode is used to assist in cooling over heated pools. If the limit has been reached, which is indicated by the limit light on, and the roof temperature drops below the limit temperature, usually sometime late at night (To set this function press the SELECT button until the TROP light is illuminated. To switch back to Summer Mode press the SELECT button until the AUTO light is illuminated.) OPERATION: The controller will turn the pump on when the roof temperature is higher than the pool (pipe) temperature by 8 C and off at 4 C. Roof temperature is received every ten seconds from the transmitter. When the pool temperature reaches the limit setting the limit light will flash, it will remain in this state while the roof is hot to prevent over heating the pool. The controller will then wait for night time to pass and the roof to reach 40 C the next day to start the process again, this is to prevent the solar starting too early in the morning. If the roof does not achieve 40 C the following morning the

system will break out of its hold mode 12 hours from when the pool first reached limit. These functions are to minimise the pool from overheating, hence reducing water evaporation and consumption of chemicals. An auto flush program is incorporated to ensure accurate pool temperature readings are obtained as the pool sensor is normally located well away from the actual swimming pool and may sit in direct sunlight or in warm enclosures, the last recorded pool temperature will be displayed for 6 hours from when the pump was last running. When auto flush is in wait mode the limit light will be on constant until the pump is turned on for a three minute test, the pump light will flash until this test is over. FAULT DIAGNOSIS: In the event of a sensor or cable failure, the display will indicate the type of failure as follows; ROOF SENSOR A display of 99 indicates a broken or disconnected sensor cable or open circuit sensor. A display of 88 indicates wrong polarity connection or short-circuited cable or sensor. A display of 89 indicates a high sensor reading out of normal operating range. A display of 00 indicates no roof transmitter reception. POOL SENSOR A display of 77 indicates a broken or disconnected sensor cable. A display of 66 indicates wrong polarity or short-circuited sensor cable. A display of 67 indicates a sensor reading out of normal operating range.

WARRANTY - SSV2BR This range of product is covered by a limited 3 year warranty against component failure or faulty workmanship from the date of installation. A faulty unit should be returned in the first instance to the dealer from which the unit was purchased. Damage to the unit due to misuse, power surges, lightning strikes or installation that is not in accordance with the manufacturer s instruction may void the warranty. Warranty does not cover travel costs to or from installation site. Return to supplier for repair Customer Record (to be retained by the customer) Dealer/Installer Name: Model Number: Serial Number: Date Installed: SSV2BR For service assistance phone 1300 130 693 Dontek Electronics Pty Ltd PO Box 239 Bayswater, Victoria 3153 www.dontekelectronics.com.au