Data sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL * _0119*

Similar documents
Data Sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61B MOVIDRIVE compact, MOVIDRIVE A Information regarding UL

Data sheet. MOVITRAC 07B, MOVITRAC 07A Information regarding UL * _1216*

Drive Technology \ Drive Automation \ System Integration \ Services. Data sheet. MOVIAXIS Multi-Axis Servo Inverter. Information regarding UL

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

Operating Instructions

Revision. Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, * _0315*

Manual. Conversion Aid MOVIDRIVE MDR60A Regenerative Power Supply Unit Series from DCV185 to DCV200

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

Revision MOVITRAC LTE-B * _1114*

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

* _1015* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Drive Unit MGF..-DSM

Synergy EN product information

MOVIDRIVE MDR Regenerative Power Supply. Energy-efficient overall concept. Drive Technology \ Drive Automation \ System Integration \ Services

Manual motor starter MS132

Miniature Circuit Breakers

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

C E R T I F I C A T E O F C O M P L I A N C E

Addendum to the Operating Instructions

8 BK brakes. 8.1 Description of BK brakes (CMP40 to CMP63) Description of BK brakes (CMP40 to CMP63)

For regenerative operation, the MOVIPRO is connected to an external braking resistor.

LOW VOLTAGE SWITCHGEAR

Correção das Instruções de Operação

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Addendum to the Geared Servomotors Catalog

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

BETA Switching Switches and Light Indicators

Electronic overload relays EF205 and EF370

* _0916* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Synchronous Linear Motors SL2

Bulletin 1489 Circuit Breakers. Selection Guide

Control Circuit Protection

Kasutusjuhendi parandus

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

3 Project Planning. 3.1 Additional documentation. Project Planning. Additional documentation 26 GSE2005

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Correcties bij de technische handleiding

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

3 - Protection components Motor circuit-breakers

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Eksploatacijos vadovo pataisa

Thermal overload relay TF140DU and TF140DU-V1000

Drive Technology \ Drive Automation \ System Integration \ Services. Käyttöohjeen korjaus MOVITRAC LTP-B/LTX, LTP-A, LTE-B

OTEC Transfer switch open transition

ACW Molded-Case Circuit Breaker UL 489 Listed

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

EPS/ELA-Series User Manual EPS/ELA 250W

CA Z-EN Overload relays, CT-operated overload relays

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Installation Instructions

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

User Manual. Solar Charge Controller 3KW

1 Phase electronic contactor (SC 1)

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

SIRIUS 3RU2 Thermal Overload Relays

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Operating Instructions

Thermal overload relay TF65 and TF96

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

XT IEC Power Control Manual Motor Protectors

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

PD-Series Ground Fault Circuit Protection

Electronic overload relay EF65, EF96 and EF146

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Addendum to the Operating Instructions

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Series L9 UL-489 Miniature Circuit Breakers

C E R T I F I C A T E O F C O M P L I A N C E

Power Switching Devices

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Selection Guide. Control Circuit and Load Protection

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

UMBW-UL489 and UL1077 Listed

Application Description

Reduced Voltage Motor Starters

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Pump Panel Specifications

CMS Electric Cylinder. Addendum to the Operating Instructions. Edition 11/ / EN

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

AP/UP, AP/MIL Series Magnetic Circuit Protectors

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Horizontal Circuit Switchers

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

AT30 SERIES BATTERY CHARGER

C E R T I F I C A T E O F C O M P L I A N C E

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services *25950274_0119* Data sheet MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL Edition 01/2019 25950274/EN

SEW-EURODRIVE Driving the world

Content Content 1 MOVIDRIVE MDX60B/61B... 4 1.1 Information regarding UL... 4 1.2 Wiring diagrams for basic device... 8 2 MOVIDRIVE MDR60A/61B and MDX62B... 11 2.1 Information regarding UL... 11 2.2 Wiring diagrams... 14 3 MOVIDRIVE compact... 17 3.1 Information Regarding UL... 17 3.2 Wiring diagram for basic unit... 19 4 MOVIDRIVE A... 21 4.1 Information Regarding UL... 21 4.2 Wiring diagram for basic unit... 23 Data sheet Information regarding UL 3

1 MOVIDRIVE MDX60B/61B Information regarding UL 1 MOVIDRIVE MDX60B/61B 1.1 Information regarding UL INFORMATION The UL-certification does not apply to operation on voltage supply systems with a non-grounded star point (IT systems). 1.1.1 Field wiring power terminals Use 75 C copper wire only - models with suffix 0075, 0110, 0370, 0450, 0550, 0750, 0900, 1100, 1320, 1600, 2000, 2500. Use 60/75 C copper wire only - models with suffix 0005, 0008, 0011, 0014, 0015, 0022, 0030, 0037, 0040, 0055, 0150, 0220, 0300. Tighten terminals to in-lbs (Nm) as follows: Series Size in-lbs Nm MOVIDRIVE MDX 60B/61B 0XS, 0S, 0L 5 0.6 1, 2S 5 0.6 2 13 1.5 3 31 3.5 4, 5 120 14 6 180 20 7 620 70 Field wiring is to be made using listed ZMVV Lugs - models size 2, 3, 5. 1.1.2 Short circuit current rating Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes when protected by fuses and circuit breakers as described in the tables below. 65,000 rms symmetrical amperes when protected by ABB and Rockwell Type E Combination Motor controllers as described in the tables below. MOVIDRIVE MDX60B/61B 0005-2500 (400 V units only). Max. voltage is limited to 500 V. MOVIDRIVE MDX60B/61B 0015-0300 (230 V units only). Max. voltage is limited to 240 V. 4 Data sheet Information regarding UL

MOVIDRIVE MDX60B/61B Information regarding UL 1 1.1.3 Branch circuit protection Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes. AC 400/500 V devices Three Phase 380 V 500 V Voltage Range Model 0005 (Size 0S) 0008 (Size 0S) 0011 (Size 0M) 0014 (Size 0M) 0015 (Size 1) 0022 (Size 1) 0030 (Size 1) 0040 (Size 1) 0055 (Size 2S) 0075 (Size 2S) 0110 (Size 2) 0150 (Size 3) 0220 (Size 3) 0300 (Size 3) 0370 (Size 4) 0450 (Size 4) 0550 (Size 5) 0750 (Size 5) 0900 (Size 6) SCCR: 200 ka/ 500 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 200 ka/ 500 V when protected by Inverse-Time Circuit Breaker SCCR: 65 ka/ 480 V: when protected by 1) : SCCR: 65 ka/ 480 V when protected by: Type E Combination Motor Controller 15 A / 600 V 25 A max / 500 V Min ABB, Model MS132-2.5 Rated 480 V, 1 HP 15 A / 600 V 25 A max / 500 V Min ABB, Model MS132-4.0 Rated 480 V, 2 HP 15 A / 600 V 25 A max / 500 V Min ABB, Model MS132-4.0 Rated 480 V, 2 HP 15 A / 600 V 25 A max / 500 V Min ABB, Model MS132-6.3 Rated 480 V, 3 HP 35 A / 600 V 25 A max / 500 V Min ABB, Model MS132-6.3 Rated 480 V, 3 HP 35 A / 600 V 25 A max / 500 V Min ABB, Model MS132-6.3 Rated 480 V, 3 HP 35 A / 600 V 25 A max / 500 V Min ABB, Model MS132-10 Rated 480 V, 5 HP 35 A / 600 V 25 A max / 500 V Min ABB, Model MS132-12 Rated 480 V, 7.5 HP 60 A / 600 V 25 A max / 500 V Min ABB, Model MS132-16 Rated 480 V, 10 HP 60 A / 600 V 25 A max / 500 V Min ABB, Model MS132-20 Rated 480 V, 10 HP 60 A / 600 V - ABB, Model MS132-32 Rated 480 V, 20 HP 175 A / 600 V 90 A max / 500 V Min ABB, Model MS450-40E or MS165-42, Rated 480 V, 30 HP 175 A / 600 V 90 A max / 500 V Min ABB, Model MS495-63E Rated 480 V, 50 HP 175 A / 600 V 90 A max / 500 V Min ABB, Model MS495-75E Rated 480 V, 60 HP 350 A / 600 V 175 A max / 500 V Min ABB, Model MS495-90E Rated 480 V, 75 HP 350 A / 600 V 175 A max / 500 V Min - - 225 A / 600 V 175 A max / 500 V Min - - 225 A / 600 V 175 A max / 500 V Min - - 250 A / 600 V 300 A max / 500 V Min - - Model 140M-C2E-B25, Rated 480 V, 1.5 HP Model 140M-C2E-B40, Rated 480 V, 3 HP Model 140M-C2E-B40, Rated 480 V, 3 HP Model 140M-C2E-B63, Rated 480 V, 5 HP Model 140M-C2E-B63, Rated 480 V, 5 HP Model 140M-C2E-B63, Rated 480 V, 5 HP Model 140M-C2E-C10, Rated 480 V, 7.5 HP Model 140M-D8E-C16, Rated 480 V, 10 HP Model 140M-D8E-C16, Rated 480 V, 10 HP Model 140M- D8E-C20, Rated 480 V, 15 HP Model 140M-F8E-C32, Rated 480 V, 25 HP Model 140M-F8E-C45, Rated 480 V, 30 HP - - - Data sheet Information regarding UL 5

1 MOVIDRIVE MDX60B/61B Information regarding UL Three Phase 380 V 500 V Voltage Range Model 1100 (Size 6) 1320 (Size6) 1600 (Size 7) 2000 (Size 7) SCCR: 200 ka/ 500 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 200 ka/ 500 V when protected by Inverse-Time Circuit Breaker SCCR: 65 ka/ 480 V: when protected by 1) : SCCR: 65 ka/ 480 V when protected by: Type E Combination Motor Controller 300 A / 600 V 300 A max / 500 V Min - - 400 A / 600 V 300 A max / 500 V Min - - 400 A / 600 V 600 A max / 500 V Min - - 500 A / 600 V 600 A max / 500 V Min - - 2500 (Size 7) 600 A / 600 V 600 A max / 500 V Min - - 1) Drives employing Type E Combination Motor Controller model MS132-12, -16, -20, -25, -32 must be installed with Current Limiter Series S803W-SCLxxx-SR manufactured by ABB, otherwise SCCR rated 30kA/ 480 Vrms. AC 230 V devices Three Phase 200 V 240 V Voltage Range Model 0015 (Size 1) 0022 (Size 1) 0037 (Size 1) 0055 (Size 2) 0075 (Size 2) 0110 (Size 3) 0150 (Size 3) 0220 (Size 4) SCCR: 200 ka/ 240 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 200 ka/ 240 V when protected by: Inverse-Time Circuit Breaker SCCR: 65 ka/ 240 V when protected by: 1) SCCR: 65 ka/ 240 V when protected by: Type E Combination Motor Controller 30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-10 Rated 480 V, 5 HP 30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-10 Rated 480 V, 5 HP 30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-20 Rated 480 V, 10 HP 60 A / 250 V 40 A max / 240 V Min ABB, Model MS132-25 Rated 480 V, 15 HP 60 A / 250 V 40 A max / 240 V Min ABB, Model MS450-40E or MS165-42, Rated 480 V, 30 HP 175 A / 250 V 90 A max / 240 V Min ABB, Model MS450-50E or MS165-65, Rated 480 V, 40 HP 175 A / 250 V 90 A max / 240 V Min ABB, Model MS495-63E Rated 480 V, 50 HP 350 A / 250 V 175 A max / 240 V Min ABB, Model MS495-90E Rated 480 V, 75 HP Model 140M-C2E-C10, Rated 480 V, 7.5 HP Model 140M-C2E-C10, Rated 480 V, 7.5 HP Model 140M-D8E-C20, Rated 480 V, 15 HP Model 140M-F8E-C25, Rated 480 V, 20 HP Model 140M-F8E-C45, Rated 480 V, 30 HP 0300 (Size 4) 350 A / 250 V 175 A max / 240 V Min - - 1) Drives employing Type E Combination Motor Controller model MS132-12, -16, -20, -25, -32 must be installed with Current Limiter Series S803W-SCLxxx-SR manufactured by ABB, otherwise SCCR rated 30kA/ 480 Vrms. - - - 6 Data sheet Information regarding UL

MOVIDRIVE MDX60B/61B Information regarding UL 1 1.1.4 Motor overload protection The units are provided with load and speed-sensitive overload protection and thermal memory retention upon shutdown or power loss. The trip current is adjusted to 150 % of the rated motor current. 1.1.5 Ambient temperature The units are suitable for an ambient temperature of 40 C, max. 60 C with derated output current. To determine output current rating at higher than 40 C, the output current should be derated 2.5 % per C between 40 C and 50 C, and 3 % per C between 50 C and 60 C. INFORMATION - Use only tested units with a limited output voltage (V max = DC 30 V) and limited output current (I max = 8 A) as an external DC 24 V voltage source. - UL certification does not apply to operation in voltage supply systems with a nongrounded star point (IT systems). 1.1.6 Environmental Conditions The units are for use in pollution degree 2 environments. Data sheet Information regarding UL 7

1 MOVIDRIVE MDX60B/61B Wiring diagrams for basic device 1.2 Wiring diagrams for basic device 1.2.1 Power section (sizes 0 6) and brake L1 L2 L3 F11/F12/F13 Protective earth (shield) V AC V AC V AC F14/F15 F14/F15 F14/F15 L1 L2 L3 NF... line filter option L1' L2' L3' L1 L2 L3 X1: DC link connection*** -U Z +U Z X4: Power section DBØØ DBØØ DBØØ U X2: X3: V W +R -R 1 BMK* 2 3 4 13 14 15 DGND K12 Brake plug** DGND 1 BE 2 BG 3 BGE 4 5 CT/CV/DR/DT/DV: Cut-off in the AC and DC side circuits CT/CV, CM71... 112: Cut-off in the DC and AC circuits K12 white red blue DGND 1 BE 2 BG 3 BGE 4 5 white red blue CT/CV/DR/DT/DV: Cut-off in the AC circuit M 3-phase see chapter Connecting BW.. / BW..-T / BW..-P braking resistor 9007201060300683 ** Strictly adhere to the connection sequence of the brake connector. Incorrect connection will cause irreparable damage to the brake. Observe the operating instructions of the used motors when connecting the brake using the terminal box. *** With sizes 1, 2 and 2S, there is no connection next to the supply system connection terminals and motor connection terminals (X1, X2). In this case, use the terminal next to the DC link connection (X4). INFORMATION Folgen Connect the brake rectifier using a separate supply system lead. Supply via the motor voltage is not permitted. Always switch off the brake on the DC and AC sides with: All lifting applications, Drives that require a rapid brake response time CFC and SERVO operating modes. 8 Data sheet Information regarding UL

MOVIDRIVE MDX60B/61B Wiring diagrams for basic device 1 Brake rectifier in control cabinet Install the connection cables between the brake rectifier and the brake separately from other power cables when installing the brake rectifier in the control cabinet. Joint installation is only permitted with shielded power cables. 1.2.2 Power section and DC power supply unit (size 7) For connecting the brake, refer to the wiring diagram of size 1 6. L1 L2 L3 F21/F22/F23 L1 L2 L3 F11/F12/F13 L1 L2 L3 NF... line filter option L1' L2' L3' L1 L2 L3 L1 L2 L3 9 10 11 12 DC power supply unit U X1: X2: X3: V Power section W +R -R M 3-phase Chapter Connecting BW.. / BW..-T / BW...-P braking resistor 9007201440755083 Technical data of DC power supply unit: Nominal line current: AC 2.4 A Inrush current AC 30 A / AC 380-500 V INFORMATION Note that the connection of external +24 V power supply units to the X10:9 control terminal is not permitted in backup mode via power supply unit. Incorrect connection prompts an error message. Data sheet Information regarding UL 9

1 MOVIDRIVE MDX60B/61B Wiring diagrams for basic device 1.2.3 Braking resistor BW... / BW...-...-T /BW...-...-P Power section Power section Power section X3: +R -R X3: +R -R X3: +R -R F16 affects BW...-...-P 97 95 F16 98 96 affects RB1 BW...-...-T T 2 affects 4 6 RB2 T 1 BW... When the signal contact F16 trips, must be opened and DIØØ/"controller inhibit" must receive a "0" signal. The resistor circuit must not be interrupted. Braking resistor type When the internal temperature switch trips, must be opened and DIØØ/"controller inhibit" must receive a "0" signal. The resistor circuit must not be interrupted. Design specified Overload protection Internal temperature switch (..T), (..P) BW... - - Required 9007201060304139 When the external bimetallic relay (F16) trips, must be opened and DIØØ/"controller inhibit" must receive a "0" signal. The resistor circuit must not be interrupted. External bimetallic relay (F16) BW...-...-T / P - One of the 2 options must be selected (internal temperature switch / external bimetallic relay). BW...-003 / BW...-005 Adequate - Permitted BW090-P52B Adequate - - 10 Data sheet Information regarding UL

MOVIDRIVE MDR60A/61B and MDX62B Information regarding UL 2 2 MOVIDRIVE MDR60A/61B and MDX62B 2.1 Information regarding UL 2.1.1 Field wiring power terminals Use 75 C copper wire only - models with suffix 1600, 2000, 2500. Use 60/75 C copper wire only - MOVIDRIVE MDR60A0150 0750 and MOVIDRIVE MDR61B1600 2500 Tighten terminals to in-lbs (Nm) as follows: Series Size in-lbs Nm MOVIDRIVE MDR60A/61B MDX62B 2 16 1.8 3 31 3.5 4 120 14 7 620 70 Field wiring is to be made using listed ZMVV Lugs - models size 2, 3. 2.1.2 Short circuit current rating MOVIDRIVE MDR60A0150 0750 and MOVIDRIVE MDR61B1600 2500: When these regenerative power supply units are installed with the appropriate MOVIDRIVE inverter, the system can be marked with the short circuit rating of the inverter. Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes when protected by fuses and circuit breakers as described in the tables below. 65,000 rms symmetrical amperes when protected by ABB and Rockwell Type E Combination Motor controllers as described in the tables below. Max. voltage is limited to 500 V. MOVIDRIVE MDX62B1600 2500: Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes when protected by fuses and circuit breakers as described in the tables below. 65,000 rms symmetrical amperes when protected by ABB and Rockwell Type E Combination Motor controllers as described in the tables below. Max. voltage is limited to 500 V. Data sheet Information regarding UL 11

2 MOVIDRIVE MDR60A/61B and MDX62B Information regarding UL 2.1.3 Branch circuit protection Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes. MOVIDRIVE MDR60A/61B Model SCCR: 200 ka/ 500 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 200 ka/ 500 V when protected by: Inverse-Time Circuit Breaker SCCR: 65 ka/ 480 V when protected by: SCCR: 65 ka/ 460 V when protected by: Type E Combination Motor Controller MDR60A0150 50 A / 600 V - ABB, Model MS450-50E Rated 480V, 40 HP MDR60A0370 100 A / 600 V - ABB, Model MS495-75E Rated 480V, 60 HP MDR60A0750 175 A / 600 V 175 A max / 500 V Min - - MDR61B1600 400 A / 600 V 600 A max / 500 V Min - - MDR61B2500 600 A / 600 V 600 A max / 500 V Min - - Model 140M-F8E-C45, Rated 460V, 40 HP - MOVIDRIVE MDX62B Three Phase 380 V 500 V Voltage Range Model 1600 (Size 7) 2000 (Size 7) 2500 (Size 7) SCCR: 200 ka/ 500 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 200 ka/ 500 V when protected by Inverse-Time Circuit Breaker SCCR: 65 ka/ 480 V when protected by: SCCR: 65 ka/ 460 V when protected by: Type E Combination Motor Controller 400 A / 600 V 600 A max / 500 V Min - - 500 A / 600 V 600 A max / 500 V Min - - 600 A / 600 V 600 A max / 500 V Min - - 12 Data sheet Information regarding UL

MOVIDRIVE MDR60A/61B and MDX62B Information regarding UL 2 2.1.4 Motor overload protection MOVIDRIVE MDX62B1600 2500: The units are provided with load and speedsensitive overload protection and thermal memory retention upon shutdown or power loss. The trip current is adjusted to 150 % of the rated motor current. 2.1.5 Ambient temperature The units are suitable for an ambient temperature of 40 C, max. 60 C with derated output current. MOVIDRIVE MDR60A0150 0750: To determine the output current rating at higher than 40 C, the output current should be derated 3.0 % per C between 40 C and 60 C. MOVIDRIVE MDR61B1600 2500 and MOVIDRIVE MDX62B1600 2500: To determine output current rating at higher than 40 C, the output current should be derated 2.5% per C between 40 C and 50 C, and 3% per C between 50 C and 60 C. INFORMATION - Use only tested units with a limited output voltage (V max = DC 30 V) and limited output current (I max = 8 A) as an external DC 24 V voltage source. - UL certification does not apply to operation in voltage supply systems with a nongrounded star point (IT systems). 2.1.6 Environmental Conditions The units are for use in pollution degree 2 environments. Data sheet Information regarding UL 13

2 MOVIDRIVE MDR60A/61B and MDX62B Wiring diagrams 2.2 Wiring diagrams 2.2.1 DC link connection with MDR60A0150/0370/0750 regenerative power supply unit L1 L2 L3 F11 F12 F13 Incorrect DC link connection (reverse polarity ground fault) will damage the connected devices L1 L2 L3 Line filter NF... L1' L2' L3' (AC3) U1 V1 W1 You must not connect the power connectors of the inverter! U2 V2 W2 ' ND... MOVIDRIVE / MOVITRAC X2: 1 2 L1 L2 L3 4 5 6 3 7 8 X1: X4: U V W +R -R BW... l -U Z +U Z X3: 8 9 max. 5 m F25 F26 X1: 1 2 3 L1 L2 L3 X2: X3: DGND MOVIDRIVE MDR60A0150-503-00 MDR60A0370-503-00 MDR60A0750-503-00 11 12 7a 8a bk rd TRIP -D +D -U Z +U Z -U Z +U Z 1 7b 2 DC+24 V- output 3 4 5 inhibit ready for operation red: MDR not ready yellow: MDR ready -U Z +U Z 8b 7c 8c rd bk rd bk DGND Connection of additional inverters. Use a sub-distributor if required. F16 acts on 1877029771 14 Data sheet Information regarding UL

MOVIDRIVE MDR60A/61B and MDX62B Wiring diagrams 2 2.2.2 DC link connection with MDR60A0150 regenerative power supply unit with brake module function. L1 L2 L3 F11 F12 F13 K12 (AC3) L1 L2 L3 line filter NF... L1' L2' L3' U1 V1 W1 U2 V2 W2 ' ND... 1 2 X1: X4: 3 L1 L2 L3 MOVIDRIVE / MOVITRAC (max. 30 kw) 7 8 -U Z +U Z max. 5 m X1: 1 2 3 L1 L2 L3 X3: TRIP DGND MOVIDRIVE MDR60A0150-503-00 1 2 DC+24 V- output 3 4 5 inhibit Ready for operation red: MDR not ready yellow: MDR ready DGND X2: X3: U V W +R -R 4 5 6 8 9 X2: -D +D -U Z +U Z -U Z +U Z 11 12 7a 8a 7b -U Z +U Z 8b 7c 8c F25 F26 bk rd BW... l F16 acts on 3627533963 Data sheet Information regarding UL 15

2 MOVIDRIVE MDR60A/61B and MDX62B Wiring diagrams 2.2.3 DC link connection with MDR61B1600/2500 regenerative power supply unit In conjunction with MOVIDRIVE MDX61B/62B1600 2500 (size 7) L1 L2 L3 L1 L2 L3 Incorrect DC link connection (reverse polarity, ground fault) will damage the connected devices! F21 F22 F23 F31 F32 F33 F11 F12 F13 L1 L2 L3 line filter NF... L1' L2' L3' You must not connect the power connectors of the inverter! 1 2 3 L1 L2 L3 X1: X4: L1 L2 L3 9 10 11 12 DC 24 V pwr L1 L2 L3 9 10 11 12 DC 24 V pwr X1: 1 2 3 L1 L2 L3 MOVIDRIVE MDX61B/62B1600 MDX61B/62B2000 MDX61B/62B2500 -U Z +U Z 7 8 DLZ 11B -U Z +U Z MOVIDRIVE MDR61B1600-503-00/L MDR61B2500-503-00/L X2: X3: U V W +R -R 4 5 6 8 9 X2: BW... l F16 acts on 3347843723 16 Data sheet Information regarding UL

MOVIDRIVE compact Information Regarding UL 3 3 MOVIDRIVE compact 3.1 Information Regarding UL 3.1.1 Field wiring power terminals Use 75 C copper wire only models with suffix 0075, 0110, 0370, 0450, 0550, 0750. Use 60/75 C copper wire only models with suffix 0015, 0022, 0030, 0037, 0040, 0055, 0150, 0220, 0300. Tighten terminals to in-lbs (Nm) as follows: Series Frame Size in-lbs Nm MOVIDRIVE compact 1 5 0.6 2 13 1.5 3 31 3.5 4, 5 120 14 3.1.2 Short circuit current rating Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes when protected by fuses as described in the tables below. MOVIDRIVE compact models with suffix 0015 to 0750 (400 V units only). Max. voltage is limited to 500 V. MOVIDRIVE compact models with suffix 0015 to 0300 (230 V units only). Max. voltage is limited to 240 V. 3.1.3 Branch circuit protection Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes. For maximum fuse rating see tables below. 400/500 V units MOVIDRIVE compact MC_4_A...5_3 Max. supply short circuit current Max. supply voltage Max. fuse rating Non Semiconductor Fuses 0015/0022/0030/0040 AC 200000 A AC 500 V AC 35 A / 600 V 0055/0075/0110 AC 200000 A AC 500 V AC 110 A / 600 V 0150/0220 AC 200000 A AC 500 V AC 175 A / 600 V 0300 AC 200000 A AC 500 V AC 225 A / 600 V 0370/0450 AC 200000 A AC 500 V AC 350 A / 600 V 0550/0750 AC 200000 A AC 500 V AC 500 A / 600 V 230 V units MOVIDRIVE compact MC_4_A...2_3 Max. supply short circuit current Max. supply voltage Max. fuse rating Non Semiconductor Fuses 0015/0022/0037 AC 200000 A AC 240 V AC 30 A / 250 V 0055/0075 AC 200000 A AC 240 V AC 110 A / 250 V 0110 AC 200000 A AC 240 V AC 175 A / 250 V 0150 AC 200000 A AC 240 V AC 225 A / 250 V 0220/0300 AC 200000 A AC 240 V AC 350 A / 250 V Data sheet Information regarding UL 17

3 MOVIDRIVE compact Information Regarding UL 3.1.4 Motor overload protection Motor over temperature sensing is required. 3.1.5 Ambient temperature The units are suitable for an ambient temperature of 40 C, max. 60 C with derated output current. To determine output current rating at higher than 40 C, the output current should be derated 2.5 % per C between 40 C and 50 C, and 3 % per C between 50 C and 60 C. INFORMATION - An external DC 24 V voltage supply has to be limited to a max. voltage U max = DC 30 V and max. current I max = 8 A.. - UL certification does not apply to operation in voltage supply systems with a nongrounded star point (IT systems). 3.1.6 Environmental Conditions The units are for use in pollution degree 2 environments. 18 Data sheet Information regarding UL

MOVIDRIVE compact Wiring diagram for basic unit 3 3.2 Wiring diagram for basic unit 3.2.1 Wiring the power section and brake L1 L2 L3 F11/F12/F13 Protective earth (shield) V AC V AC V AC F14/F15 F14/F15 F14/F15 L1 L2 L3 NF... line filter option L1' L2' L3' L1 L2 L3 X1: DC link connection* 1 2 3 7 8 -U Z +U Z X4: Power section X2: X3: U V W +R -R DBØØ DBØØ DBØØ 4 5 6 8 9 1 BMK 2 3 4 13 14 15 DGND K12 Brake connector DGND 1 BG 2 3 BGE 4 5 CT/CV/DT/DV/D: Cut-off in the DC and AC circuits CT/CV, CM71... 112: Cut-off in the DC and AC circuits K12 white red blue DGND 1 BG 2 3 BGE 4 5 white CT/CV/DT/DV/D: Cut-off in the AC circuit red blue M 3-phase see section "Connecting braking resistors BW... / BW..-T / BW...-P" 2040155659 * With sizes 1 and 2, there is no connection next to the supply system connection terminals and motor connection terminals (X1, X2). In this case, use the terminal next to the DC link connection (X4). Important: Read the operating instructions for the motors when connecting the brake. INFORMATION If the brake rectifier is connected via the supply system lead, the braking function is restricted. - Connect the brake rectifier using a separate supply system lead. - Supply via the motor voltage is not permitted! Always switch off the brake on the DC and AC sides with: All hoist applications Drives that require a rapid brake response time CFC and SERVO operating modes Data sheet Information regarding UL 19

3 MOVIDRIVE compact Wiring diagram for basic unit Brake rectifier in control cabinet Install the connection cables between the brake rectifier and the brake separately from other power cables when installing the brake rectifier in the control cabinet. Joint installation is only permitted with shielded power cables. 3.2.2 Connecting BW... / BW...-...-T /BW...-...-P braking resistors Power section Power section Power section X3: +R -R X3: +R -R 8 9 X3: +R -R 8 9 F16 Has effect on BW...-...-P 97 95 F16 98 96 Has effect on RB1 BW...-...-T T 2 Has effect on 4 6 RB2 T 1 BW... When the auxiliary contact trips, must be opened and DIØØ"/Controller inhibit" assigned a "0" signal. Do not interrupt the resistor circuit! Braking resistor type When the internal temperature switch triggers, must be opened and DIØØ"/Controller inhibit assigned a "0" signal. Do not interrupt the resistor circuit! Design specified Overload protection Internal temperature switch (..T) BW... - - Required When the external bimetallic relay (F16) triggers, must be opened and DIØØ"/Controller inhibit" assigned a "0" signal. Do not interrupt the resistor circuit! 2040159371 External bimetallic relay (F16) BW...-...-T - One of the two options (internal temperature switch / external bimetallic relay) is required. BW...-003 / BW...-005 Adequate - Permitted 20 Data sheet Information regarding UL

MOVIDRIVE A Information Regarding UL 4 4 MOVIDRIVE A 4.1 Information Regarding UL 4.1.1 Field Wiring Power Terminals Use 75 C copper wire only models with suffix 0370 to 0750. Use 60/75 C copper wire only models with suffix 0003 to 0300. Tighten terminals to in-lbs (Nm) as follows: Series Frame Size in-lbs Nm MOVIDRIVE A 1 5 0.6 2 13 1.5 3 31 3.5 4, 5 120 14 4.1.2 Short Circuit Current Rating Suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical amperes: MOVIDRIVE B models with suffix 0005 to 0014 and 0055 to (400 V units only). Max. voltage is limited to 500 V. MOVIDRIVE B models with suffix 0015 to 0150 (230 V units only). Max. voltage is limited to 240 V. Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes: MOVIDRIVE B models with suffix 0015 to 0040 and 0370 to 0750 (400 V units only). Max. voltage is limited to 500 V. MOVIDRIVE B models with suffix 0220 to 0300 (230 V units only). Max. voltage is limited to 240 V. Data sheet Information regarding UL 21

4 MOVIDRIVE A Information Regarding UL 4.1.3 Branch Circuit Protection Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes. For maximum fuse rating see tables below. 400/500 V devices MOVIDRIVE MD_60A...5_3 max. Netzstrom max. Netzspannung Sicherungen 0015/0022/0030/0040 10000 A AC 500 V AC 30 A / 600 V 0055/0075/0110 10000 A AC 500 V AC 30 A / 600 V 0150/0220 5000 A AC 500 V AC 175 A / 600 V 0300 5000 A AC 500 V AC 225 A / 600 V 0370/0450 10000 A AC 500 V AC 350 A / 600 V 0550/0750 10000 A AC 500 V AC 500 A / 600 V 230 V devices MOVIDRIVE MD_60A...2_3 Max. supply short circuit current Max. supply voltage Max. fuse rating Non Semiconductor Fuses 0015/0022/0037 AC 200000 A 240 VAC 30 A / 250 V 0055/0075 AC 200000 A 240 VAC 110 A / 250 V 0110 AC 200000 A 240 VAC 175 A / 250 V 0150 AC 200000 A 240 VAC 225 A / 250 V 0220/0300 AC 200000 A 240 VAC 350 A / 250 V 4.1.4 Motor overload protection Motor over temperature sensing is required. 4.1.5 Ambient Temperature The units are suitable for an ambient temperature of 40 C, max. 60 C with derated output current. To determine output current rating at higher than 40 C, the output current should be derated 2.5 % per C between 40 C and 50 C, and 3 % per C between 50 C and 60 C. INFORMATION - Use only tested units with a limited output voltage (U max = DC 30 V) and limited output power (P 100 VA) as an external DC 24 V voltage source. - UL certification does not apply to operation in voltage supply systems with a nongrounded star point (IT systems). 22 Data sheet Information regarding UL

MOVIDRIVE A Wiring diagram for basic unit 4 4.2 Wiring diagram for basic unit 4.2.1 Connection of the power section and brake L1 L2 L3 Protective earth conductor (shield) F11/F12/F13 L1 L2 L3 F14/F15 V AC F14/F15 V AC F14/F15 V AC Option NF... input filter L1' L2' L3' DC link connection * 1 2 3 8 7 L1 L2 L3 X1: Power section +VDC link - V X4: DC link X2: X3: U V W +R -R X10:3 DBØØ X10:3 DBØØ X10:3 DBØØ 4 5 6 8 9 X10:2 DGND K12 K12 1 BMK 2 3 4 13 14 15 Brake connector** CM (DY) 5 (1) 4 (2) 3 (3) X10:2 DGND 1 BG 2 3 BGE 4 5 white CT/CV/DT/DV/D: simultaneous switch-off in the AC and DC circuits. CM/DFY71...112: simultaneous switch-off in the AC and DC circuits. DFS56: 24 V supply of the brake without brake rectifier red blue X10:2 DGND 1 BG 2 3 BGE 4 5 white red blue CT/CV/DT/DV/D: switch-off in the AC circuit. M 3- phase BW... F16 affects mustbeopened in case F16 triggers andx13:1 ( DIØØ "/Controller Inhibit") must receive a 0 signal.do not separate the resistor circuit! 2042174347 * With sizes 1 and 2, there is no connection next to the mains connection terminals. In this case, use the terminal next to the DC link connection. Important:It is essential to adhere to the sequence of connections. Incorrect connection will lead to irreparable damage to the brake. INFORMATION A separate supply system lead is required for connecting the brake rectifier. Powering it from the motor voltage is not permitted! Always switch off the brake on the DC and AC sides under the following conditions: all hoist applications, drives which require a rapid brake reaction time and in CFC and SERVO operating modes. Data sheet Information regarding UL 23

4 MOVIDRIVE A Wiring diagram for basic unit Brake rectifier in switch cabinet Route the connection cables between the brake rectifier and the brake separately from other power cables when installing the brake rectifier in the switch cabinet. Joint routing is only permitted if the power cables are shielded. 24 Data sheet Information regarding UL

SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Str. 42 76646 BRUCHSAL GERMANY Tel. +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com