NO-BREAK KS. Dynamic UPS system PRESENTATION

Similar documents
Experience and History

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

CONTINUOUS POWER IN YOUR CONTROL KEM5

Power Conditioning of Microgrids and Co-Generation Systems

Glossary/Technical appendix

DC POWER SUPPLY SYSTEMS

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

DP INNOVATION. A Novel Solution to Common Mode Failures in DP Class 2 Power Plant

Unit Protection System for Pumped-Storage Power Stations

D Series: UPS UPTO - 300KVA - Three / Three Phase

Master Plus kva

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

SS SyStem SyStemy free UPS tter ba UPS

PowerWave 33 Efficient power protection for today s IT and process-related work environments

WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner!

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

Power Factor Improvement

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Regenerative Utility Simulator for Grid-Tied Inverters

ADF. Restoring the perfect wave

DYNACOMP. The top-class reactive power compensator

ELG4125: Flexible AC Transmission Systems (FACTS)

.3 Section Waste Management and Disposal.

MASTERYS IP+ 10 to 80 kva

E-15 Uninterruptible Power Systems (UPS)

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Dead bus synchronizing. Applications

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

Excitation systems for high power synchronous generators with redundant configurations

34 th Hands-On Relay School

Power Protection Discrete Automation & Motion South Africa

Electrical Test of STATCOM Valves

Transmission Problem Areas. Bulk power transfer over long distances Transmission Limitations/Bottlenecks have one or more of the following:

E-15 Uninterruptible Power Systems (UPS)

Master Plus kva

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Standby Power Systems

Wind protection. Low-voltage switching and protection strategies in wind turbines

TECHNICAL SPECIFICATION

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

DG SYNCHRONIZING &AMF PANEL

ABB UPS 3. November 2014

TECHNICAL SPECIFICATION

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

Overview Overvoltage protection

KD LV Motor Protection Relay

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

off-grid Solutions Security of supply Basics: Off-grid energy supply

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Integration of Large Wind Farms into Electric Grids

Sources, Effect, and melioration. Power Quality Problems. Asnil Elektro FT UNP

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Electric Networks/Ina Lehto Updated Original 12/2011

SINAMICS GM150 IGCT version

ROTATING MAGNETIC FIELD

MGE TM Galaxy TM 7000 GFC

UPS Multi Sentry 10-20kVA

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Product Specifications

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Standard specification Galaxy PWi, three-phase, 10 to 200 kva

PowerValue 11/31 T kva

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

PRODUCT CATALOGUE 2016

Power stability for manufacturers

European Aviation Safety Agency

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

VOLTAGE SAGS; A LITTLE STORAGE CAN GO A LONG WAY

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

UPS Multi Power 1-28 x 42 kw up to 1MW

ALTERNATOR DE-EXCITATION WITH K1 AND K2 ON ANALOGUE

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

FINHRM FINHRM5 FINHRMA FINHRMAC

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Simply Reliable Solutions for Continuous, High Quality Power Tradition. Technology. Innovation.

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

PI144D - Technical Data Sheet

PI144J - Technical Data Sheet

SIMINE DRAG. Innovative solutions for maximum productivity and reliability. Mining Technologies

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Industrial PFC UPS System

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

HIGH EFFICIENCY MODES OF OPERATION. Path toward highest energy efficiency without load availability trade-off

capacity due to increased traction; particularly advantageous on road surfaces

Power Challenges Faced by Vehicle Applications

Transcription:

NO-BREAK KS Dynamic UPS system PRESENTATION

Contents Chapter 1: Description of No-Break KS System...3 Chapter 2: Operation when mains power is available...4 Chapter 3: Operation when mains supply is disrupted...6 Chapter 4: Description of No-Break KS Systems, type KS-SB...8 Chapter 5: Resilience...10 Chapter 6: "Single-redundancy" type installations...11 Chapter 7: Parallel installations...12 Chapter 8: Medium voltage No-Break KS Systems...15 Chapter 9: Performance...16 Chapter 10: Summary of main advantages...18 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 2/18

Chapter 1: Description of No-Break KS System 4 5 1 2 3 Figure 1 The main components, as shown in Figure 1, are as follows: 1. A diesel engine; 2. An electromagnetic brushless clutch; 3. A special brushless rotating machine, called a "stato-alternator", composed of: 1 synchronous alternator 1 kinetic energy accumulator with single excitation 4. A power cabinet containing the motorized breaker units and an inductance; 5. A control panel containing, a PLC, and the dedicated electronic circuit boards to control and monitor of operation the system. S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 3/18

Chapter 2: Operation when mains power is available I3 D3 DA D1 SELF D2 DB CRITIQUES Figure 2a During "Normal Operation" (mains supply available), the input (D1) and output breakers (D2) are closed, the automatic by-pass (D3) is open and the system supplies power to the critical loads via No-Break KS System. The synchronous alternator acts as a motor. The shaft of the stato-alternator rotates at 1500 rpm while the kinetic energy accumulator is held at a speed of 2950 rpm. During this "Normal Operation", which usually represents 99.9% of the operating cycle time, the No-Break KS System: 1. ELIMINATES ANY MICRO-BREAKS All micro-breaks with a duration of less than 50 milliseconds are eliminated by the system, even under 100% load, and without starting up the diesel engine. 2. REGULATES THE SYSTEM VOLTAGE Whenever there are fluctuations in the system voltage, the electronic voltage regulation system acts on the excitation current of the synchronous alternator. The voltage supplied is automatically maintained at ± 1% of its set value. Any variation in the supply voltage greater than ± 10% causes the input breaker to be opened and the diesel engine to start. S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 4/18

3. IMPROVES THE POWER FACTOR Overexcitation of the synchronous alternator provides all the reactive power consumed by the load. This means that the power factor for the whole system is close to unity. The synchronous alternator is acts a perfect substitute for having the critical loads connected to a bank of condensers, while at the same time avoiding all their associated problems. 4. FILTERS OUT TRANSIENT PHENOMENA The "inductance synchronous alternator" system separates the system and the load when rapid or harmonic transient phenomena occur. On the one hand, the load is protected from disturbances in the mains power supply voltage (overvoltage from lightning strikes, switching spikes, voltage harmonics etc.) and, even in the case of a very disturbed mains, allowing the loads to benefit from a very high quality supply. On the other hand, power consumption peaks (motor starts, short-circuits etc.) and the harmonic currents caused by the load (in the event of non-linearity) are filtered out by the No-Break KS System. Pollution of the supply by the critical load is thus greatly reduced. All these Power Quality functions are provided while at the same time the system operates at very high efficiency levels (93 to 96,4% according to the exact model): in fact, the active power consumed by the load does not pass via the synchronous alternator (which operates simply as a free-running motor). S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 5/18

Chapter 3: Operation when power supply is disrupted. I3 D3 DA D1 SELF D2 DB Figure 2b During normal operation (mains supply present): The diesel engine is stopped (clutch open) The shaft of the stato-alternator turns at 1500 rpm. The kinetic energy accumulator turns at 2950 rpm. S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 6/18

The input breaker opens as soon as a failure in the mains power supply is detected. Instantaneously, the synchronous alternator which was operating as a motor reverts to an alternator while the control panel modulates the inductive coupling between the main shaft and the accumulator rotor, the supply to the critical loads is maintained without any major disturbance to the voltage (less than 5 % in voltage value and less than 1 % in frequency). At the same time that the input breaker opens, the electric starter motor cranks over the diesel engine. Approximately one second later, the electromagnetic clutch slowly closes, thus establishing a mechanical link between the diesel engine and the stato-alternator. The diesel engine rapidly takes up the load and the electronic speed governor holds the speed constant, supplying the mechanical power needed for the active electrical power required by the load. From this moment onwards, the kinetic energy accumulator is progressively brought back to its set speed. Once the mains power supply returns to normal, and provided that the kinetic energy accumulator has come up to speed, the system returns to normal operation. The diesel engine runs without any load in order to cool before shutting down. GUARANTEE THAT THE DIESEL ENGINE WILL START Experience gained in the field of generators demonstrates that one of the weak points in their application is the absence of any guarantee that the diesel engine will start. The causes of these starting failures are normally starter motor defects, battery fault, maintenance problems etc. The No-Break KS System solves this weak point with an original solution providing a redundant start-up sequence. Even if the diesel engine does not start when the input breaker has opened, the clutch will still close and mechanically connect the stato-alternator to the diesel engine. The kinetic energy accumulator then forces the diesel engine to start. This forced start-up sequence can occur occasionally and has no detrimental effect on the clutch or the diesel engine. S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 7/18

Chapter 4: Description of No-Break KS Systems, type KS-SB The No-Break KS Systems comprise synchronous alternators that are largely oversized. This means that by modifying the diesel engine and the clutch it is possible to supply essential loads after a brief interruption. Normally the essential loads must not be greater than the critical load. This type of KS-SB system allows a single system to supply a complete computer center ( typically supporting computers, air conditioning, lighting, lifts, etc.). Various configurations are possible: Figure 3: Figure 4: Figure 5: No-Break KS System, type KS-SB2 No-Break KS System, type KS-SB1 No-Break KS System, type KS-SB0 I3 D3 DA D1 SELF D2 DB D6 CRITIQUES C6 ESSENTIAL C5 Figure 3: NO-BREAK KS System, type KS-SB2 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 8/18

C5 ESSENTIAL DA I3 I3 D1 D3 SELF Figure 4: NO-BREAK KS System, type KS-SB1 D3 D2 DB D6 C6 ESSENTIAL DA D1 SELF D2 DB Figure 5: NO-BREAK KS System, type KS-SB0 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 9/18

Chapter 5: Resilience The aim of resilience is to create two sets of downstream breakers configured such that the failure of one has only a limited effect on the other. Figure 6 shows how this aim is achieved in the case of a No-Break KS system. It should be noted that this resilience can be usefully exploited by the incorporation of static switches allowing a critical load to be supplied from two almost independent breakers. I3/1 I3/2 D1 D3 D2 DB2 DB1 Figure 6 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 10/18

Chapter 6: "Single-redundancy" type installations The No-Break KS Systems can be combined in order to create a "single-redundancy" type installation, as shown in figure 7. In this type of installation, the redundant No-Break KS system may be used to instantaneously substitute for any other system. As a variation, the essential loads can also be connected to each of the down stream breakers. I3/1 D3/1 DC/1 DA/1 D1/1 D2/1 DB/1 DY/1 KS/1 I3/2 D3/2 DC/2 DA/2 D1/2 D2/2 DB/2 DY/2 I3/N KS/2 D3/N DC/N DA/N D1/N D2/N DB/N DY/N KS/N I3/R D3/R DE/R DA/R D1/R D2/R DB/R DY/R ESSENTIAL KS/R Figure 7 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 11/18

Chapter 7: Parallel installations 1. PARALLEL CONNECTION OF SEVERAL No-Break KS SYSTEMS The No-Break KS systems and the type KS-SB No-Break KS systems can be installed in parallel (figures 8a and 8b). This layout allows the installation to be easily adapted to the load and to evolve with it. In parallel systems, the maximum power that the installation can provide is equal to N times the nominal power rating of a single system (N being the number of systems installed in parallel). I3 D3/1 DA/1 D1/1 D2/1 DB/1 KS/1 DA/2 D1/2 D3/2 DB/2 D2/2 KS/2 D3/N DA/N D1/N DB/N D2/N KS/N Figure 8a S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 12/18

I3 D3/1 DA/1 D1/1 D2/1 DB/1 KS/1 DA/2 D1/2 D3/2 D2/2 DB/2 KS/2 D3/N DA/N D1/N DB/N D2/N KS/N C6/N C5/N C6/1 C5/1 ESSENTIAL C6/2 C5/2 Figure 8b S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 13/18

2. PARALLEL REDUNDANT INSTALLATIONS Redundancy is achieved by installing one or more systems in addition to the N systems strictly necessary to supply the loads. 3. PARALLEL INSTALLATIONS (REDUNDANT OR NOT) WITH RESILIENCE It is possible to install No-Break KS systems in parallel each with a twin set of resilient down stream breakers (figure 9). I3 MANUAL BY-PASS D3/1 DA/1 D1/1 D2/1 DB2/1 DB1/1 DA/2 D3/2 D1/2 D2/2 DB2/2 DB1/2 D3/3 DA/3 D1/3 D2/3 DB2/3 DB1/3 LOAD A LOAD B Figure 9 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 14/18

Chapter 8: Medium voltage No-Break KS Systems Where the supply is medium voltage (generally required for power ratings above 5 MVA), the No-Break KS systems provide a technically superior solution (figure 10). The inductance and the breaker components operate at medium voltage levels. Conversely, the low voltage stato-alternator is connected to the medium voltage via a reversible transformer. One of the advantages of this solution is that under normal service operation a high level of efficiency is attained and therefore low operating costs are guaranteed. TR3 D1/3 KS3 D2/3 D1/2 TR2 KS2 D2/2 TR1 D1/1 KS1 D2/1 D3I NTR TRA DSN DLA D3O DA Automatic By-Pass DB I1 I3I Manual By-Pass I2 I3O Figure 10 S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 15/18

Chapter 9: Performance ING USERS WITH IDEAL VOLTAGE AND FREQUENCY VALUES 1. VOLTAGE 1.1. Voltage regulation under steady state conditions...± 1% 1.2. Voltage variations induced by load steps of: 10 %...± 1% 50%...± 3% 100%...± 5% (The voltage is restored to ± 1% in less than 1 second) 1.3. Temporary voltage variation during Mains supply failure...± 5% Mains supply return...± 1% 1.4. Voltage regulation with 25% imbalanced load...± 2% 2. PHASE ANGLE With balanced load: With 25% imbalance: 120 ± 0 degree 120 ± 1 degree 3. FREQUENCY 3.1. Frequency regulation with steady state load...± 0,2% 3.2. Frequency variation induced by load steps of: 10%...± 0,5% 50%...± 1% 3.3. Temporary frequency variation during Mains supply failure and 100% of the load being taken up...± 1% Mains supply return...± 0,2% S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 16/18

4. EFFICIENCY In normal operation: 93 to 96.4 % 5. OVERLOAD ALLOWED In normal operation: In emergency operation: 10% for 1 hour 25% for 10 minutes 1 50% for 2 minutes 1 10% for 1 hour 6. TOTAL HARMONIC LEVELS Less than 2% for a linear load 7. SHORT-CIRCUIT CURRENT Upstream: 3 In Downstream: 12 to 20 In 8. RADIO INTERFERENCE Conforming to VDE level K 9. CERTIFICATE ACCORDING TO EMC DIRECTIVE 1 Percentage of rated output power S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 17/18

Chapter 10: Summary of main advantages 1. Reliability. 2. Monobloc unit. 3. Unique system, completely free of rings and brushes. 4. Absolute guarantee that the diesel engine will start using the kinetic energy of the accumulator should the conventional starting system fail. 5. Accumulation of kinetic energy before returning to normal service; this allows successive power supply failures to be handled. 6. Bearing replacement every 10 years. 7. Life of No-Break KS System of at least 20 years. 8. A single unit to handle both types of load: critical and essential. 9. Service production able to cope with long term power supply failures. 10. Efficiency up to 96,4 % under full load which minimizes operating costs. 11. Small size and may be installed in an area without air conditioning and without anti-acid treatment. 12. Electrical control panel composed mainly of simple components (only 8 dedicated circuit boards). 13. Harmonic filtration and acceptance of deforming loads. 14. Elimination of micro-failures during normal operation. 15. Voltage stabilization at the terminals for the load. 16. Immune to up-line and down-line perturbations such as: Short-circuits Voltage spikes due to lightning strikes of operator error Calls for current Etc. 17. Automatic supply of reactive power, guaranteeing a power factor close to unity upline of the No-Break KS installation. 18. Operation and maintenance can be carried out by a technician without any special training. S\KS5_COM\V:\KC5EN\UPS_Presentation_VTENG_101002.doc Page 18/18