Components and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel

Similar documents
Technical Documentation about limit switch boxes for rotary- and linear atuators acc. to guidline 94/9/EC, IBExU 07 ATEX 1155

RAUTER Sensor-Boxes - 1 -

Product cataloge 2017

Solenoid coils VACF Type codes

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Type 4746 Electric or Pneumatic Limit Switch

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Magnetic switch For bypass level indicators Model BGU

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Position Switches Series 8074/2

Electrical position indicators and combi switchboxes for linear and quarter turn valves

Sensor boxes SRBE Key features and product range overview

Position Switches Series 8070/2

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC. Selection and ordering

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Limit Switch Type 3776

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Limit Switch Type 4747

Limit switch attachments DAPZ

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Control Buttons / Switches for Panel Mounting Series 8003

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Junction box for EKL light

LMK 387. Stainless Steel Probe DRUCK & TEMPERATUR LEITENBERGER GMBH. Ceramic Sensor

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Accord DS/DM Series UltraSwitch Switch box

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type Electronic Limit Switch

Terminal Boxes in Stainless Steel SLS**.T

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Electrical position indicators and combi switchboxes for linear and quarter turn valves

Position Switches Series 8060/2

KINAX SR 709 Transmitter for Position Feedback

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

2/2- and 3/2-way solenoid valve for aggressive fluids

Our policy is one of continued research and development. We therefore reserve the right

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Electronic Limit Switch Type

Direct-acting 3/2 way plunger valve

Room thermostats type series TRM

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Assembly. Trunk IN + - S U, I U, I. Spur 1

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

HERION SERIES Indirect solenoid actuated soft seal

Rod thermostats (without immersion tube)

Series 3730 Electropneumatic Positioner Type

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

HTSB system System overview

Pneumatic control unit for decentralized automation of ELEMENT process valves

Solenoid coil for control in potentially explosive areas Type BZ

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

EX-D ENCLOSURES AND DISTRIBUTIONS

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Electrical position feedback for actuator sizes Ø mm

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

INSTRUCTION MANUAL (ATEX / IECEx)

SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08

Solenoid Valves Type 3963

Limit Switch Type 3776

Integrated Control modules

Load disconnect switch Series 8146/5-V11

Compact Sheet-Steel Light Fittings Series 6114/1

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

Number: TEPEx.RS.067 Rev : 02 Date: Manufacturer General safety information s Purpose Degree of protection 2.

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Linear actuators DFPI

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

M-0. M-0... series control, monitoring and signalling devices. Ex e

JUMO dtrans p20 DELTA

Ex m Solenoid Operator Type 0519

Plug and Socket Devices SolConeX 16 A Series 8570

97100 NAMUR. Technical data

Floodlight Series 6521/4

ExBin-P Pressure switches 5 Pa Pa

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Our policy is one of continued research and development. We therefore reserve the right

Transcription:

- 1 - Documentation about Ex i - 45 C 8 V DC limit switch boxes with Pepperl+Fuchs sensors for pneumatic rotary- and linear actuators acc. to guidline 2014/34/EU, IBExU 04 ATEX 1211 II 2G Ex ia/ib IIC/IIB T6 Gb II 2D Ex ia/ib IIlC T 80 C Db Topic: Page: 1. Objectives and practical use 2 2. Technical specification 3 3. Mechanical mounting / Electrical connection 3.1 Mechanical mounting 3.2 Electrical connection 3 3 3 4. Components and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel 6 6 8 7. Applicable standards 10

- 2-1. Objectives and practical use The positions of industrial valves represent an important piece of information for the course of action of a production. These valves are e.g. actuated with pneumatic rotary- and linear actuators at which the end position of the valve like open or closed is reported back to a control system. This is done via a mounted limit switch boxes which are placed on / at the actuator. Use of the above mentioned limit switch boxes can be found in endangered explosive areas as specially for oel and gas industry in extremely cold areas suchlike Siberia - Russia. Equipment group II, category 2G, zones 1, 2 or 2D, zones 21, 22, see image 1-3. Image 1-3: aluminium low temperature limit switch boxes, size.: 125x80x57mm, for rotary- and linear actuators with 2x Pepperl+Fuchs sensors SJ 3,5-SN, temperature range: - 45 C Ta +70 C

- 3 - Technical specification Table 1: Technical specifications as well as conditions of use for the low temperature limit switch boxes equipment group II, category 2G, zone 1, 2 or 2D, zone 21, 22 Term / Identifier: Technical specifications: Potential recyclables and Aluminium grey, 125x80x57mm measurements Interface: Box to bracket 4xM6-winding at the bottom hole circle 50mm, F05-slot Interface: Box to bracket for - acc. to VDI/VDE 3845, steam hight 20, 30 and rotary- or linear actuator 50mm, hole spacing 80x30mm and 130x30mm - mounting set f. linear actuators acc. to IEC 534 Surrounding temperature array - 45 C T a + 70 C Protection class of the housings IP 65 Ignition protection class II 2G Ex ia/ib IIC/IIB T6 Gb II 2D Ex ia/ib IIIC T 80 C Db Temperature class T6 Nominal voltage Nominal current Power U i = 16 V I i = 25 ma P i = 34 mw Cable gland M20x1,5mm, 13-9,0mm Joint clamp max. 2,5mm² Weight (without bracket) 0,5kg Display and switching range 0-90, 0-180 or adjustable Pepperl+Fuchs sensor SJ 3,5-SN, C I = 50 nf und L i = 250µH, more details see page 5 3. Mechanical mounting / Electrical connection 3.1 Mechanical mounting: The low temperature limit switch boxes with the mounted brackets or the mounted aluminium plate (via F05-slot) and the mounting set are placed on / at the rotary- or linear actuator and screwed together. 3.2 Electrical connection: The low temperature limit switch boxes are electrically connected to the 4-pole clamp clamp within the housing through the bush and cable clands tightening torque, see operating instructions page 6-9. Data like cable thickness and cable cross section are shown in table 1. You also have to take the attached wiring diagram into consideration which can always be found on the left long surface within the housing or directly on the pcb-see image 4. Metal parts have to be grounded or the metal housing has to be connected to the equipotential bonding.

- 4 - Image 4: wiring diagram about connection the 2x Pepperl+Fuchs sensors SJ 3,5-SN at the 4-pole clamp 4. Components and parts list Table 2: Components and parts list of the low temperature limit switch boxes equipment group II, category 2G, zone 1, 2 or 2D, zone 21, 22 Term/Identifier Article-No. Material Comments Aluminium empty housing: Consisting of a lower part with F05-slot, shaft bushing 12mm, tap hole M20x1,5 mm, closed cover as well as 4 pieces of cover screws SB-AL-L-T AL-Si 12 125x80x57mm, grey Cable gland nickel-plated, Sealing insert Cable gland stainless steel, Sealing insert SB-KL-T MS LSR SB-KL-VA-T 1.4301 LSR M20x1,5mm, clamping range for cables 13-9,0mm Pflitsch-type: U28.UNI Ex e -60 C-+180 C M20x1,5mm, clamping range for cables 13-9,0mm Pflitsch-type: U28.UNI Ex e -60 C-+180 C 2 pieces clamp SB-V Plastic 2,5 mm 2, blue, Fa. Bartec Shaft for trench shaped sensors SB-W-schl 1.4305 12x64mm, Z.-No. 002 O-Ring for shaft SB-O-T Silikon 9x1,5mm Washer for shaft, 2 pieces SB-U POM 18/ 12x1,2mm Lock washer for shaft, 2 pieces SB-S V2A DIN 6799-9 Cam switches for shaft, 2 pieces SB-S-s AL Z.-No. 003 Cable binder, 2 pieces SB-K Neylon 99x2,5mm Wiring diagram and sensor label SB-Sch-S PVC 30x32mm and 2 pieces 8x4mm aluminium plate grey for mounting set SB-AB Al 135x80x10mm,Z.-Nr.: 061 acc. to Namur IEC 534 Sensors with attachment screws and nut: SJ 3,5-SN Housing PBT 10x15x19mm,

- 5-5. Data sheet sensor SJ 3,5-SN (Extract from Pepperl+Fuchs data sheet page 1)

- 6-6. Cable gland 6.1 Cable gland nickel-plated

- 7 -

- 8-6.2 Cable gland stainless steel

- 9 -

- 10-7. Applicable standards EN 60079-0: 2012+A11:2013 Explosive atmospheres - Part 0: Equipment - General requirements EN 60079-11: 2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety i