MSR 12 Basic unit. The basic unit MSR 12 includes the PR3 pressure measurement module and the ACC3 3-axis accelerometer.

Similar documents
Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Beck. The differential pressure transmitter for air with IP65

Pressure transmitters for industrial applications Type MBS 4510

Emergency lighting units EM series

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

STT280 SEALED TILT SENSOR

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Application Note TADII - Threshold Angle Detector Operation and Calibration Instructions

Pressure transmitter for industrial applications Type MBS 4510

Specification Approval Sheet

Heating oven with mechanical control

Pressure Transmitters

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

INSTRUMENTATION & CONTROL

ReadStar & CapStar Range Torque Readouts & Torque Testers. Crane Electronics Inc The force in torque management

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Pressure transmitter COMPACT ECOnomic

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

RS MODEL 2030

Portable pressure calibrator, Wally Box III Model CPH7600

Specification Approval Sheet

Pressure Transmitter

Digital Engine Tachometer

Arm - TX series 40 family

CTE7000 / CTU7000 Series Miniature pressure transmitters

JUMO MIDAS S05 Pressure transmitter Type

Sorting Line with Detection 24V

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Heating oven with natural convection

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

Hydro Stator End Winding Accelerometer System

Wind Direction Transmitter First Class Low Power Device with digital output, 10 Bit serial-synchronous x0.001

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Electronic Pressure Switches

Hydro Stator End Winding Accelerometer System

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Specification Approval Sheet

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

HX-P420 SERIES 4 to 20 ma OUTPUT

Pressure transmitter for industrial applications Type MBS 4500

DR. ALFRED MÜLLER METEOROLOGISCHE INSTRUMENTE KG R. FUESS. Windmeasuring System AEW20

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

DPI 620 Genii. Advanced Modular Calibrator and HART / Foundation Fieldbus Communicator. GE Measurement & Control

Programming of different charge methods with the BaSyTec Battery Test System

Environment Clean Room Specification

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

SPG-DIGI. Operating Instruction. Please read carefully before use!

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

25W Rechargeable LED Spotlight ' Beam - 8aH Battery - Wireless Remote - Magnetic Mount

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Electropneumatic Timing Relays Series 7000 Industrial

EAS822 (Contrac) Power Electronic Unit

Operating instructions Binary level sensor. LI214x /00 04/2016

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Micro-Machined Silicon Transducers

NHTSA OBLIQUE/SMALL OVERLAP MOVING BARRIER (OMDB)

Vert-X 31E - 24V / 4-20mA. Applications Concrete pump Access control system Fork lift

SPT- I / U PRESSURE TRANSMITTER for general applications

Differential Pressure and Flow meters Accessories for the Media Series

CTE8000 / CTU8000 Series

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Heating oven with mechanical convection

Emergency lighting units EM powerled

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

M2-iLAN-2 Laser Scanner

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

2-Color Display High-Precision Digital Pressure Switch

MOM2 Microhmmeter. MOM2 Microhmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

OEM Pressure Transmitters

Time Delta S Fixed Transit-Time Flow Meter System

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Electronic pressure switch with integrated analogue output

Differential pressure transmitter PASCAL Ci4 Delta P

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

ACTUATORS POSITION SENSOR

Transcription:

MSR 12 Basic unit The basic unit MSR 12 includes the PR3 pressure measurement module and the ACC3 3-axis accelerometer. Module PR3 Pressure Temperature Display/ 0-15 000 mbar -10 C to +60 C Display resolution: Accuracy of internal air pressure sensor: 1 mbar 1 C ±2.5 mbar max. (at 750-1100 mbar absolute) ±1 C (at 20 C) 100 /s, 10 /s, 1 /s, every 10 s, every 30 s, every 60 s Simultaneous measurement of all pressures 1 x ambient pressure and temperature 2 x external pressure and temperature 1 000 000 measurements Module ACC3 Display resolution: Acceleration (3-axis) ±10 G 0.001 G 0.02 G (at 25 C) 50 /s, 20 /s, 10 /s, 1 /s, every 2 s, every 5 s, every 10 s, every 30 s Sequential measurement of the 3 axes 1 000 000 measurements General Dimensions: 137 x 74 x 27 mm Weight: approx. 180 G Power supply: 3 x rechargeable batteries (NiMH) 880mAh External power pack Operating conditions: Temperature: 0-50 C With special cable: 3 Storage conditions: Temperature: -20 C to +70 C 1 Attachable sensors: Pressure sensors Item number P2500-4 AIR B10130 P14K-3 AIR B10127 P2500 WATER B10121 P14K WATER B10110

MSR 12 plug-in module 3ACCF The 3ACCF accelerometer module processes and logs measurements from an external acceleration sensor. Acceleration (3 axis) Display/ ± 10 G Display resolution: 0.001 G 1000 /s 10 /s 500 /s 1 /s 200 /s every 2 s 100 /s every 5 s 50 /s every 10 s 20 /s every 30 s Simultaneous measurements 1 x 3-axis acceleration sensor 4000000 measurements per axis Integration with MSR 12: By qualified personnel B10103 Attachable sensors: Acceleration sensors Item number 3ACCF-RS232 10 G B10132 3ACCF-RS232 2 G B10137

Accelerometer 3ACCF The 3ACCF sensor measures acceleration in the X, Y and Z axes. The sensors are contained in a housing that is linked to the MSR 12 via cable. The sensor housing can best be fixed using the four mounting holes. 3ACCF-RS232 2g ADXL202AE Acceleration (3 axis) ±2 G 0.001 G 0.02 G (25 C) B10137 68 56 Z 6 3ACCF-RS232 10g -Y Y 1,6 (12) 13,6 ADXL210AE Acceleration (3 axis) 4x ø3,2 -Z ±10 G -X 0.01 G -Y Y X 62 3 3,5 24 31 0.1 G (25 C) B10132 General Medium: Dimensions: Air See drawing Cable length: 2 m Weight exc. cable: Approx. 15 G Electrical connections: Plug for MSR 12 RS232 socket Power supply: Via MSR 12 Material: Sensor housing: Epoxy, ABS Operating conditions: Temperature: -20 C to +70 C Storage conditions: Temperature: -20 C to +70 C Special feature: Calibration coefficients stored in EEPROM Required additional module: 3ACCF (Item number B10103)

MSR 12 plug-in module PR8 The PR8 pressure module processes and logs pressure and temperature values from external pressure sensors. Display resolution: Pressure Temperature of the pressure sensors 0-15 000 mbar -10 C to +60 C 1 mbar 1 C 20 /s every 10 s 10 /s every 30 s 2 /s every 60 s 1 /s Simultaneous measurements of all pressure values Max. 8 pressure sensors 1000000 measurements Integration with MSR 12: By qualified personnel B10018 Attachable sensors: Pressure sensors Item number P2500-4 AIR B10130 P2500 WATER B10121 P14K-3 AIR B10127 P14K WATER B10110

Air pressure sensors The air pressure sensor is linked to the pressure system by means of the rapidaction coupling provided. The sensor is contained within a stainless steel casing and is connected to the MSR 12 via cable. P2500-4 AIR MS5534A Pressure / temperature 0-2500 mbar absolute -10 C to 60 C 1 mbar 1 C ±2.5 mbar max. (at 750-1100 mbar absolute) ±1 C (at 20 C) B10130 63,5 ø 17 P14K-3 AIR General Medium: Dimensions: MS5535A Pressure / temperature 0-14 000 mbar absolute -10 C to +60 C 1 mbar 1 C ±25 mbar max. (at 0-5 000 mbar, 0 C to +50 C) ±160 mbar max. (at 0-14 000 mbar, -10 C to +60 C) ±1 C at 20 C B10127 Air See drawing Cable length: 1.6 m Weight exc. cable: 52 G Electrical connections: Plug for MSR 12 (LEMO) Power supply: Via MSR 12 Material: Sensor housing: Stainless steel Operating conditions: Temperature: -10 C to +60 C Storage conditions: Temperature: -20 C to +70 C Special feature: Calibration coefficients stored in EEPROM Required additional module: PR8 (Item number B10018)

Water pressure sensors The pressure sensor is encased in silicon and measures the pressure and temperature of a system filled with water. It is linked to the MSR 12 via cable. An optionally available multi-layer seal allows the cable to be routed through one or more water-tight barriers. 50 P2500 WATER MS5534A Pressure Temperature 0-2500 mbar absolute -10 C to +60 C 0.1 mbar 1 C ±2,5 mbar max. (750-1100 mbar absolute) ±1 C at 20 C 8,5 B10121 ø31,5 M16x0,5 ø 28 12,5 P14 K WATER General Medium: Dimensions: MS5535A Pressure Temperature 0-14 000 mbar absolute -10 C to +60 C 0.1 mbar 1 C ±25 mbar max. (0-5000 mbar, 0 C to 50 C) ±160 mbar max. (0-14 000 mbar, -10 C to +60 C) ±1 C at 20 C B10110 Water See drawing Cable length: 1.6 m Weight exc. cable: 7 G Electrical connections: Plug for MSR 12 (LEMO) Sensor sheath material: Silicon Operating conditions: Temperature: -10 C to +60 C Storage conditions: Temperature: -20 C to +70 C Required additional module: PR8 (Item number B10018)

MSR 12 plug-in module T24HUM8 The T24HUM8 additional module for the MSR 12 processes and logs the values measured by external temperature or humidity sensors. Module T24 Temperature Display/measurement range: ±150 C Display resolution: 0.01 C 1 s intervals every 10 s every 30 s every 60 s Simultaneous measurement of all temperatures Max. 24 temperature sensors 1000000 measurements Module HUM8 Relative humidity Temperature of humidity sensor Display/measurement range: 0-100 % relative humidity ±100 C Display resolution: 0.01 % 0.01 C 1 s intervals every 10 s every 30 s every 60 s Simultaneous measurements of all humidities Max. 8 humidity sensors 1 000 000 measurements General Integration with MSR 12: By qualified personnel B1006 Attachable sensors: Sensors Item number Temperature sensor T-3 B10012, B10013 Core temperature sensor B10014 Humidity sensor HUM B10011

Temperature sensors The temperature sensor is encased in epoxy and measures the temperature even in inaccessible places such as inside a glove. The core temperature sensor was designed to take anal/rectal temperatures. Both temperature sensor types are linked with the MSR 12 via cable. Temperature sensor T-3 approx. approx. approx. 9 Temperature sensor T-3 Cable length: Weight exc. cable: 3 x 1.1 m or 3 x 1.6 m or 3 x 2.5 m 5 G Cable length 1.1 m: B10013 Cable length 1.6 m: B10012-2 Cable length 2.5 m: B10012-3 Core temperature sensor Cable length: Weight exc. cable: 1.6 m 3 G B10014 Core temperature sensor 10 (94) approx. ø4 approx. 104 ø5.5-6.5 General DS18B20 Temperature 0.0625 C Electrical connections: Power supply: Via MSR 12 Sensor sheath material: Medium: Dimensions: -40 C to +70 C (optional -40 C to +125 C) ±0.5 C max. (at -10 C to +85 C) optional ±0.2 C max. (at 20 C to 40 C) Plug for MSR 12 (LEMO) Polyolefin Air, water See drawing Operating conditions: Temperature: -40 C to +70 C With special cable: -40 C to +125 C Storage conditions Temperature: -20 C to +70 C Required additional module: T24HUM8 (Item number B10006)

Humidity sensor HUM The humidity sensor measures relative humidity and temperature even in places that are difficult to access such as inside a jacket. The sensor is linked with the MSR 12 via cable. 20 ø4.5-6.0 Humidity sensor HUM Electrical connections: SHT15 Relative humidity Temperature 0-100 % relative humidity -20 C to +60 C 0.05 % relative humidity 0.01 C Power supply: Via MSR 12 Dimensions: Cable length: Weight exc. cable: Sensor sheath: Medium: < ±2 % relative humidity (at 10-90 % relative humidity, 0 C to 40 C) ±0.5 C (at 0 C to 40 C) Plug for MSR 12 (LEMO) See drawing 1.6 m 2.5 m Approx. 5 G Silicon Air Operating conditions: Temperature: -20 C to +60 C Storage conditions: Temperature: -20 C to +70 C Cable length 1.6 m: B10011-1 Cable length 2.5 m: B10011-2 Required additional module: T24HUM8 (Item number B10006)

MSR 12 plug-in heart rate module HR The HR plug-in module processes and logs the heart rate (pulse) measured by the POLAR transmitter chest strap. Display resolution: Pulse (heart beats per minute) 1 bpm (beat per minute) 1 / s, every 10 s, every 30 s, every 60 s MSR 12 plug-in heart rate module HR Integration with MSR 12: Attachable sensors: Following each heart beat the heart rate (heart beats per minute) is recalculated. The measurement rate determines how often the MSR 12 logs the last calculated heart rate. The storage rate determines how often the heart rate is stored. Radio signal from the POLAR transmitter chest strap 1 000 000 measurements By qualified personnel B10017 POLAR T61 coded transmitter chest strap POLAR transmitter chest strap

MSR 12 plug-in ECG module This plug-in module serves to record an ECG signal. The unit can also compute the pulse (heart rate). ECG Pulse ECG: 1 value Pulse: 1 bpm 200 Hz Storage rate: ECG: 200 /s, 100 /s, 50 /s Pulse: 1 /s, every 10 s, every 30 s, every 60 s Integration with MSR 12: Attachable sensors: ECG signal with 3 electrodes (optional 2 ECG) 4 000 000 measurements By qualified personnel B10100 ECG cable with 3 electrodes B10126

MSR 12 valve-tester plug-in module The valve tester measures the delay time between the control pulse and the output signal. It logs this time together with the value of the output signal and a time stamp. In addition, the delay time is analysed. Voltage Delay time between control pulse and output signal Analysis of the delay time during the test Voltage: 0-2.7 V Delay time: 0-30 000 ms Counter: 23 Bit Voltage: 12 bit Delay time: 1 ms Counter: 1 bit Selectable up to 10 khz Docking station Pressure sensor Optoelectronic coupler Storage rate: Integration with MSR 12: Accessories: All measured delay times Each measured delay time is recorded and logged together with the output signal 4 analogue inputs for optional use as Voltage input Analogue pressure input Digital input 0-10 V Digital optoelectronic coupler input Digital input with photo diode Each input can be defined as a control pulse of an output signal 1 000 000 measurements By qualified personnel B10106 Docking station DS1 B10135 Attachable sensors: Sensors Item number Pressure sensor PA-21SR/16bar S10015 Optoelectronic coupler DS1 IF OPTO B10136 Photo diode DS1 IF FOTO B10139

MSR 12 plug-in module AIN4-12 The universal module AIN4-12 records and logs four input voltages. Voltage Voltage: 0-2.4 V Input voltage divider, optional (max. 48 V) Voltage: 12 bit 1000/s, 200/s, 500/s, 100 /s, 50 /s, 20 /s, 10 /s, 5 /s, 2 /s, 1 /s Special feature: Integration with MSR 12: Voltages are measured sequentially 4 analogue inputs 4 000 000 measurements Linear transfer function for voltage measurements is switchable By qualified personnel B10106

MSR 12 plug-in module AIN4-10 The universal module AIN4-10 records and logs four input voltages. Voltage Voltage: 0-3.0 V Input voltage divider, optional (max. 48 V) Voltage: 10 bit 100 /s, 50 /s, 20 /s, 10 /s, 5 /s, 2 /s, 1 /s Voltages are measured sequentially Up to 4 analogue inputs 1000000 measurements Special feature: Linear transfer function for voltage measurements is switchable Integration with MSR 12: By qualified personnel B10019

MSR 12 plug-in module A2D5HUM1 The A2D5HUM1 plug-in module records two input voltages, the level of five digital inputs, the signal from one humidity sensor and the temperature of the humidity sensor. Either the instantaneous value or the average, minimum and maximum values can be logged. In addition, a threshold value can be set and an event triggered should this threshold be exceeded. MSR 12 - plug-in module A2D5HUM1 Module A2D5 Voltage Digital level Voltage: 0-3 V Digital level: 0-3 V Voltage: 10 Bit Digital level: 1 Bit 100 /s, 10 /s, 1 /s, every 10 s, every 30 s, every 60 s Voltages are measured sequentially 2 x voltage 5 x digital level 1 000 000 measurements Combined pressure and humidity sensor Module HUM1 Humidity Temperature Humidity 0-100 % relative humidity Temperature: -20 C to 60 C Display resolution: 0.01 % Temperature: 0.01 C 1 / s, every 10 s, every 30 s, every 60 s Humidity and temperature are measured sequentially 1 x humidity and temperature 1 000 000 measurements General Integration with MSR 12: By qualified personnel B10107 Attachable sensors: Sensors Item number Pressure and humidity sensor H-P14K-2 AIR B10104-2