Rotron MAXIAX 5.75 Large Vaneaxial Fans

Similar documents
Rotron MAXIAX Large Vaneaxial Fans

Rotron MIL-80 Tubeaxial Fans

Rotron MIL901 Tubeaxial Fans

6400 RPM. All aluminum components finished with a chemical Weight: approximately 0.74 lbs.

Rotron HF/ HFV/ HFG Propeller Fans

Rotron NANOS Small Vaneaxial Fans

Airscrew 200+ Vmax Vaneaxial Fans

Airscrew 105 to 170 Vmax Vaneaxial Fans

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Square Mixed Flow Fans (MFQ)

Silencer Series Brushless DC Motors

Silencer Series Brushless DC Motors

DC Dual Inlet Centrifugal Blowers

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Bifurcated Case Axial Fans (BIFA)

EKM Series Motors. For Aerospace & Defense Applications

Sentinel D-Box Single Fan

Acoustic Twin Fans (ATQ)

Mixed Flow Roof Fans (RMH)

Sentinel D-Box Twin Fan

IN-LINE CENTRIFUGAL DUCT FANS VT Series

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

SQUARE INLINE CENTRIFUGAL FANS

2

FAN POWERED TERMINAL UNITS

Hammond Electronic Rack Packaging

Vertical Hi-Rise Fan Coil Unit (Model FS)

Sabre Plate Mounted Sickle Fans (VSP)

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Mixed Flow Roof Fans (RMH)

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

SECTION MOTOR REQUIREMENTS for HVAC

SUPER-MAX INDUCTION MOTOR

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

AVC FAN. AC Axial Fans. AC Axial Fans

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Kollmorgen Frameless Motor Selection Guide

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Brushless DC Axial Fans

Compumotor BE Series Size 16 Specifications

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

NEW Acoustic In-Line Fans (ACQ)

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Vent-Axia Sabre Sickle Roof Fans (VSR)

Electromechanical Rotary Actuator

Quantum Series Size 17, 23, 34 and 56 Brushless Servo Motors Frameless and Housed Engineering Guide

NEW Slimpak EC Box Fan (SLPT EC)

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Square Inline Fans with Multi-Directional Discharge

SILENT MV Ultra Quiet In-line Fans

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ceiling & inline/cabinet ventilators

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

Smart. Eco-friendly. Cost effective. The way. Technology. should be PRODUCT CATALOGUE

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

CEILING & INLINE/CABINET VENTILATORS

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

Climate Control Products

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

TD-ECOWATT AND DECOR-ECOWATT Series

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Application Information

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

BC-2014 ULTRA COMPACT 4-BAY SMART BATTERY CHARGER (Military Grade)

1.9" (48mm) Slotless Brushless Air Cooled Bearing Motor.

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

ELECTRIC HEAT AIR HANDLERS

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

TEC2010 SERIES SINGLE SCROLL DC MOTORS BH4400 / BH1700 / BH1900 DC MOTORS. DCM manufacturing, inc. 153

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

Am Rotböll Weiterstadt Telefax /

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Carol Lewellen-NEEC and BOC Tuesday, May 8, Sessions Session

FCVC Series VERTICAL FAN COILS

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

High-Torque Design, Low-Cost Package

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Chart, Inc. Data Sheet 2s241K Cryocooler

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Vertical Floor Fan Coil Unit (Model FW)

KW Submersible, Single-Vane Impeller

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

M SERIES. ASTM F998 Close-Coupled Centrifugal Pump

MODEL FF50 CEILING FAN

Sensorless Brushless DC-Servomotors

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

Transcription:

Rotron MAXIAX 5.75 Large Vaneaxial Fans General Large Vaneaxial Information MAXIAX fans provide relatively high flows against high impedance in a compact axial flow package. They operate at high rotational speeds, typically with 400 Hz motors or internal ECDC brushless motors. MAXIAX fans are extremely efficient and highly customizable, allowing for precise airflow design. MAXIAX fans are typically utilized to cool airborne radar and other devices with high power transmitters. They are also employed as evaporator/condenser fans in environmental controls systems and to duct air to Rotron MAXIAX 5.75 various aircraft avionics bays, cockpit displays and cabin compartments. MAXIAX fans are also used extensively in general aviation aircraft, military vehicles and shelters and shipboard applications. They come in a variety of voltages and frequencies and are available with lead wires, terminal blocks and MS connectors. Most units are available with an optional internal Fan Performance Sensor (FPS) or an internal or external Low Speed Warning Device (LSWD). Maxiax 5.75 Series: Maximum Performance Curve* 18 16 14 12 Static Pressure (inches water gauge) 10 8 11300 RPM 6 4 2 0 0 200 400 600 800 1000 1200 Airflow (cfm) *Individual Performance Curve Characteristics Available Upon Request General Materials and Finishes Physical envelope: 5.75 diameter, 5.50 to 10.6 All aluminum components finished with a chemical lengths 1. conversion coating per MIL-C-5541, top coat of Weight: 6.7 to 12.0 lbs. lusterless black enamel, color #37038, per Federal Specially designed for avionics/equipment cooling and Standard 595 conforming to TT-E-489 Type B. environmental control systems. Corrosion-resistant stainless steel shaft and hardware. Speeds as high as 14,500 RPM. Impeller runs on two high-precision, double-shielded, Airflow as high as 1046 CFM. stainless steel ball bearings (ABEC Class 5) for a long, Functional Static Pressures: as high as 12 IWG. maintenance-free life. Motors have stator winding insulation which is rated for continuous duty for either Class F or Class H. 1 Note: See specific part-number drawing for complete product dimensions Options/Accessories Flanges Beads Check Valves Custom Designs Available 06-42 Integral EMI filter LSWD (Low Speed Warning Device) FPS (Fan Performance Sensor)

AC Line Powered Units 1 3-phase and 1-phase permanent-split capacitor motor designs. Fixed speeds (performance) based on input frequency. Meets or exceeds the requirements of MIL-B-23071 and other applicable U.S. military and commercial aerospace specifications 2. Max free delivery airflow of 1046 CFM at 400 Hz. Ambient temperature range: -54 C to 100 C. DC Powered Units E.C.D.C. 1 Brushless permanent magnet design (Electronically Commutated DC). Speed (performance) fixed by input voltage. Meets or exceeds the requirements of MIL-B-28873 and other applicable U.S. military and commercial aerospace specifications 2. Max free delivery airflow of 956 CFM. Ambient temperature range: -40 C to 85 C. Acoustic levels as low as 78 dba. Standard 24 and 28 volt designs. Acoustic levels as low as 83 dba. 1 Airflow, maximum ambient and acoustic levels will vary depending on design parameters 2 Please call for further information concerning applicable U.S. military and commercial aerospace specifications Optional DC-AC Inverters and AC-AC Converters for AC Powered Models 1 BATAC Inverter Driven Units AC square wave fans driven from a DC power source through a BATAC Inverter. Low cost alternative when multiple fans are used in a single application or area. Allows for greater than 100 VDC input voltage. 1 See Accessories: Power Conversion DELTAC Converter Driven Units DELTAC converters allow high frequency (typically 400 Hz) fans to be driven by variable frequency (typically 360-800 Hz) power or low frequency 50/60 Hz power to obtain the higher frequency performance. Unit Description Key The unit description key is for reference only and should not be confused with a part number. While most units are custom configurations, not all variations of the key shown below are possible. Please contact the Application Engineering department for more information regarding possible custom configurations. AC MODELS MAX 475 01 A Q 2 C L N 1894 JF MOTOR SERIES FAN PERFORMANCE SENSOR N- WITHOUT, S-WITH CONNECTOR L- LEADWIRES M- MILITARY, MS ATTACHED TO HOUSING N- MILITARY, MS ATTACHED TO LEADS T- TERMINAL BLOCK MOUNTING CONFIGURATION A- FLANGED, INLET ONLY VOLTAGE B- FLANGED, OUTLET ONLY 1-115 C- FLANGED, BOTH ENDS 2-200 D- FLANGED INLET, BEADED OUTLET 3-115/230 E- FLANGED OUTLET, BEADED INLET 4-416 F- BEADED, BOTH ENDS G- FLANGED CENTER, PLAIN ENDS NO. NO. APPOX.. SPEED- NO LOAD (REF.) H- FLANGED CENTER, BEADED ENDS POLES PHASES 50 Hz 60 Hz 400 Hz I- PLAIN, BOTH ENDS A 2 3 2900 3500 - J- FLANGED INLET ONLY WITH INLET PERFORMANCE RING ELECTRICAL DATA B 4 3 1450 1750 - K- FLANGED OUTLET ONLY WITH INLET PERFORMANCE RING A- AC LINE OPERATED E 6 1 OR 3 950 1150 - L- FLANGED, BOTH ENDS WITH INLET PERFORMANCE RING F 8 1 OR 3 700 850 - M- FLANGED INLET, BEADED OUTLET WITH INLET PERFORMANCE RING DESIGN SEQUENCE K 2 1 2900 3500 - N- FLANGED OUTLET, BEADED INLET WITH INLET PERFORMANCE RING L 4 1 1450 1750 - O- BEADED, BOTH ENDS WITH INLET PERFORMANCE RING SIZE GROUP M 6 1 OR 3 - - 7500 P- FLANGED CENTER, PLAIN ENDS WITH INLET PERFORMANCE RING APPROXIMATE HOUSING O.D.; N 8 1 OR 3 - - 5500 Q- FLANGED CENTER, BEADED ENDS WITH INLET PERFORMANCE RING NUMBER IS DIMENSIONED IN P 12 1 OR 3 - - 3900 R- PLAIN, BOTH ENDS WITH INLET PERFORMANCE RING INCHES TO TWO DECIMAL Q 4 1 OR 3 - - 11000 S- LEGS, WITH INLET PERFORMANCE RING MAXIAX PLACES. THE PERIOD IS NOT R 2 1 OR 3 - - 23000 T- SERVO RINGS, BOTH ENDS SHOWN NOTE: DUAL FREQUENCY OR DUAL POLE MOTORS DESIGNATED BY USING 2 DIGITS. EX: KM = (2 POLE 1Φ 50/60 Hz, 6 POLE 1Φ 400 Hz X- SPECIAL DC MODELS (SAME AS AC EXCEPT WHERE INDICATED) MAX 420 01 D 28 G N N 1894 JF EXAMPLE: MAX47501AQ2CL, N, 1894 JF VOLTAGE ELECTRICAL DATA D- DC LINE OPERATED E- ECDC M- MCDC R1 06-43

Ordering Information When ordering, please specify the specific Rotron part number listed on the model table below. Further ordering information, based on the configuration and motor series, may be obtained by contacting customer service. Please refer to the Unit Description Key explanation above. Standard Product Offering of AC Line Powered Models Part # Product Description Flow (CFM) Max Pressure (IWG) Nom. RPM Nom. Watts Line Amps (A) Max Amb (C) Weight Volts Phase Hz Capacitor Airflow Source Data Features 041155000 035312000 035601000 035785000 035976000 035953000 041041000 MAX57501 1953JF MAX57500 1953JF MAX57500 2670WF MAX57503 2702JF MAX57515 3260JH MAX57507 3664X7 MAX57502 2616JF 680 14.0 11000 1385 5.1 60 8.3 200 3 400 N/A A533-28 LEADS, FPS 628 15.1 11000 1365 4.0 60 8.3 200 3 400 N/A A440-4 CONNECTOR 431 6.8 7500 382 1.6 60 8.3 200 3 400 N/A A312-22 LEADS, FPS 258 1.5 3230 147 1.0 100 6.7 115 3 60 N/A A511-19 LEADS, FPS 840 13.5 12 1456 6.1 75 7.5 200 3 400 N/A A573-9 CONNECTOR 1029 15.4 11500 1911 3.0 80 8.3 480 3 400 N/A A629-14 LEADS, TP 315 3.6 5540 173 0.8 100 6.7 230 3 400 N/A A294-29 LEADS Standard Product Offering of DC Line Powered Models Part # Product Description Flow (CFM) Max Pressure (IWG) Nom. RPM Nom. Watts Line Amps (A) Max Amb (C) Weight Volts Airflow Source Data Features 012270000 011577000 011780000 MAX57506 3259RF MAX57512 3412SF MAX57514 3674XF 990 13.0 10500 1793 64.0 70 11.4 26 A552-3 TERMINALS, C VALVE 482 5.9 8200 448 16.0 85 8.0 28 A789-18F LEADS, FPS 511 6.6 8800 497 18.5 95 7.8 28 A694-20B LEADS, FPS 06-44

MAXIAX 57500/01 AC MAXIAX 57506 DC 06-45

MAXIAX 57507 AC MAXIAX 57512 DC 06-46

MAXIAX 57515 AC 06-47

06-48

R1 06-49