DFX series. High-end Ultrasonic Flow Meters for Liquid Hydrocarbons Custody Transfer. 32 beams for ultimate performance

Similar documents
DFX Series Liquid Ultrasonic Flow Meters

DFX-MM series. High-end Ultrasonic Flow Meter for Liquid Hydrocarbons Custody Transfer. 32 beams for ultimate performance. L002G DFX-MM leaflet

HTM Series Helical Turbine Meters

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Calibration, Fluid Property Effects Reproducibility and Long Term Stability. All in 20 minutes! Dr Gregor Brown Cameron

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Proving Liquid Ultrasonic Flowmeters Summary of Testing Conducted January 2011

HERMAN HOFSTEDE. Sales Director, KROHNE Oil & Gas

Flow Research and Test Center. Creating resource technology for today and tomorrow.

Range of Ultrasonic Flowmeters.

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

Flow Research and Test Center

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

BARTON 7400 Precision Gas Turbine Flow Meters

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

OPTIMASS 2000 Technical Datasheet

Turbine flowmeters Series TM

Enraf Small Volume Prover

Technical Data. BiRotor Plus Positive Displacement Meter

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

LIQUID MEASUREMENT STATION DESIGN Class No

VLM20 In-line Vortex Flowmeter

Calibration of Pipe Provers in the field

Intercomparison Between Trapil, France and NEL, UK Using Oil Flow Turbine Meters

Non-Invasive Hydrocarbon Products Mass Flow Measurement, Media Identification and Leak Detection

WZMC-402 Ultrasonic Apartment Energy Meters

Genesis Series 2" and 3" Steel Meters

FLUXUS HPI Series. Non-Intrusive Ultrasonic Flow Measurement for the Hydrocarbon Processing Industries. External Measurement of Internal Flow FLEXIM

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

H. HERMANN EHLERS GMBH

Superstatic 440. Static Heat- and Cooling Meter. Application

CORONA E ELECTRONIC METER MULTI-JET

LIQUID MEASUREMENT STATION DESIGN with NGL CONSIDERATIONS

tprime TM Series 280T

Traceability overview

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Micro Motion 7827 Digital Viscosity Meter

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Transmitting Transducer. Gas/Air Velocity Range:

EQUALIS S. Flow computer for depots. Metering Solutions Metering Solutions. Very open communication skills. Field of application.

Multivariable Vortex Flow Meter

F-1500 SERIES INSERTION TURBINE FLOW METER

Fluxi 2000/TZ Turbine Gas Meter

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

ULTRASONIC HEAT METER

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

ORIMAS Mass Flowmeter

Multivariable Vortex Flow Meter

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Armstrong In-Line and Insertion Vortex Flow Meters

F-2700 SERIES INSERTION VORTEX FLOW METER

FLUXUS HPI Series External Measurement of Internal Flow

Micro Motion F-Series Coriolis Flow and Density Meters

Low Profile Insertion Vortex

HYDRUS ULTRASONIC METER

OPTIGAS 4010C Technical Datasheet

KB Series self averaging pitot flowmeter for gas, liquids and steam flows

CONTOIL VZFA/VZOA , versions for higher requirements / applications

OPTIGAS 4010C Technical Datasheet

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Magnetic-inductive flow meter for hazardous areas

LCMass Series Mass Flow Sensor

OPTIMASS 3000 Technical Datasheet

Principle of Operation

High Performance Turbine Technology

Micro Motion Model D and DL Coriolis Flow and Density Meters

WESAN WPV E ELECTRONIC METER WOLTMAN

F-2600 SERIES INLINE VORTEX FLOW METER

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Valves For Cryogenic Applications

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)

Flow Measurement SITRANS F S Clamp-on

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Rosemount 3051CFA Annubar Flowmeter

SHARKY FS 473 ULTRASONIC FLOW SENSOR

mass flowmeter for compressed air

TOPAS PMW-basic. Customer benefits. Product features

CORONA ER ELECTRONIC METER MULTI-JET

Countum Group. Metering Solutions. Aviation. Metering Solutions.

VORTEX IN-LINE FLOW METERS

Volumeter. RMG Meßtechnik GmbH. Publication No E

Flow Measurement SITRANS F C

MAIN FUNCTION FEATURES. . D = v t /2

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

RMG Meßtechnik GmbH. Publication No E

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Series 7000 Torque Sensor for PTO-shafts

MPD Manifold 4 x psi with Integrated Control System and Coriolis Flowmeter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

Transcription:

High-end Ultrasonic Flow Meters for Liquid Hydrocarbons Custody Transfer /03/204 Page 32 beams for ultimate performance

Features & benefits Performance A master meter class UFM exceeding current standards from Naphtas / Condensates / Liquid gases to Heavy crudes / Fuel oils Superior linearity and repeatability thanks to unequalled spatial coverage and ultra-fast scanning rate Compliant with OIML R7- class 0.3, M.I.D. 4/22/EC and API MPMS Ch5.8 Truly Provable with standard turbine prover loops Design 5 or 32-beam patented design Transit time operating principle Unique axial symetry with excentration design for really much less sensitivity to flow profile disturbances Small volume transducers cavities minimize the scaling effects and avoid gas pockets Installation Reduced straight runs installation possible No flow conditioner option Counication High integration to coon flow computers Secure ethernet counication HTML-based configuration and auditing software with open counication protocol for on-line remote technical support Powerfull flow imaging capability Service Transducers exchangeable without recalibrating the meter No zeroing adjustment needed in case of transducer replacement Thanks to their ultrasonic paths redundancy, DFX meters remain fiscal in the unlikely event of one transducer failure. Therefore replacement operation can be delayed and planned. This is a quick operation, reducing flow shutdown time /03/204 Page2 Compact integrated electronics for easy site coissioning and start-up

Applications FSO's & FPSO's custody transfer (crude oil, condensates) On & offshore allocation metering (crude oil, condensates) Pip eline metering stations (crude oil, refined products) Tanker loading/unloading terminals (crude oil, refined products, petrochemicals) Storage management (crude oil, refined products, petrochemicals) 5 beams for refined products / light oils /03/204 09/0/202 Page3 L002I leaflet L002H DFX DFX-MM leaflet 32 beams for multi-viscosity / medium to high viscosity oils

Calibration uncertainty All DFX meters are calibrated at accredited laboratories such as Trapil, France Calibration using hydrocarbons of similar viscosity to site conditions International Approvals DFX meters received approvals for fiscal metering and custody transfer in many countries. In addition, they comply with the relevant International standards such as API, OIML, GOST No master meters direct proving against ball provers for best calibration laboratory uncertainty 0,043% /03/204 Page4 Typically, meters are calibrated on 6 flowrates over 5 runs each to achieve a K-factor uncertainty of +/-0.027% at 95% confidence level as per API MPMS 4.8 table A-

Proving volume Repeatability & Heavy Oil Comparison with other UFM's DFX meters require much less other UFM's and therefore are standard turbine prover loops definitively should be proved method. prove volume than truly provable with where other UFM's by master meter DFX meters are provable with standard ball provers thanks to repeatability improved by their unequaled spatial coverage and ultra-fast scanning rate. DFXMM 0 8 - REP EAT ABILIT Y t est No pressure drop! No reducing nozzle! API MPMS chapter 5-8 recoendation Conventional UFM # 0,06% 0,04% METER ERROR % Recoended Prover Volume v/s Meter Size 30 Meter Size (inch) Conventional UFM #2 20 Dies el oil 4.9 cs t - m3/h - 0 m 3 ball prover - 5 runs 0,02% 0,00% -0,02% -0,04% -0,06% DFX-MM proving requirements 2 3 4 5 6 7 8 9 0 2 3 4 5 RUN n DFX-MM meters accurately measure viscous flows and therefore are ideal when pressure drop is the concern. 0 DFXMM 0 6 - HEAVY OIL cent is t ockes minera l oil, 6'' PD m as t er m et er Prover Volume (m3) 0 ME TER FACTOR 0,0 0 2,00,0 0 0 0,9 9 9 0,9 9 8 50 5 0 2 00 30 0 DFX-MM are repeatable according to API MPMS 4.8 Table A- including in the difficult Reynolds flow transition area (medium to high viscosity oils) /03/204 Page5 FLOWRATE M3/H

Calibration curves DFX-MM 08'' baselines Flow straightener 7D long, ball prover volume 0m3 Meter Factor JET FUEL 5,0 cst 7 C Water 6% JET FUEL 4,5 cst 24 C JET FUEL 4,5 cst 24 C Ball valve 40% closed GASOIL 8,4 cst 8 C GASOIL 8,4 cst 8 C Ball valve 40% closed OIL 5,5 cst 22 C OIL 62,0 cst 6 C Same oil, no flow conditioner 0 0 Flowrate DFX-MM 08'' baselines v/s Reynolds Number Flow straightener 7D long, ball prover volume 0m3 Meter Factor JET FUEL 5,0 cst 7 C Water 6% JET FUEL 4,5 cst 24 C JET FUEL 4,5 cst 24 C Ball valve 40% closed GASOIL 8,4 cst 8 C GASOIL 8,4 cst 8 C Ball valve 40% closed OIL 5,5 cst 22 C OIL 62,0 cst 6 C Same oil, no flow conditioner 2,000 20,000,000 2,000,000 DFX sustains a premium +/- 0.0 % accuracy with a constant K-factor over a wide range of viscosities and operating conditions. /03/204 Page6 09/0/202 L002H DFX L002I DFX-MM leaflet leaflet Reynolds Number

Proving superior performance DFX-MM 6" prove results on medium oil (5 cst) with end user ball prover, Kf deviation 8 6 4 2 0 2498 2496 2494 2492 2490 Low e r lim it -0.5% Upper lim it +0.5% 203-08-05 With FC 203-08-2 With FC 203-08-28 Without FC 203-09-02 Without FC 0 0 0 0 0 0 Flowrate (m3/hr) DFX is provable with compact provers DFX04 repeatability with 20 litres compact prover 5 runs per flowrate, 4 passes per run, medium oil 20 cst 0.0% 0.09% 0.08% 0.07% 0.06% 0.05% 0.04% 0.03% 0.02% 0.0% 0.00% 20 40 60 80 Flowrate (m3/hr) 20 40 60 /03/204 Page7 09/0/202 L002H DFX L002I DFX-MM leaflet leaflet Repeatability 5 runs Kf (Pulses/m3) DFX installation option with no flow conditioner (consult M&T to discuss your project)

DFX-MM series (32 beams) DFX-MM performance Technical data Nominal flow ranges f or s t andard accuracy +/ - 0, 5 % 4" * 6" 50 8" 0" 2" 4" 6" 8" 450 20" 24" 26" 28" 30" 750 32" 34" 850 36" 38" 950 40" 42" 050 * 5 beams design Flow rat e ( m3/ h) 5 30 60 90 30 60 2 3 3 0 6 7 0 0 0 00 20 20 20 30 30 t y pe Flow rat e (BPH ) 2 3 3 4 5 6 6 7 8 8 9 Met er s ize DFX-MM04 4'' DFX-MM06 6'' DFX-MM08 8'' DFX-MM0 0'' DFX-MM2 2'' DFX-MM4 4'' DFX-MM6 6'' DFX-MM8 8'' DFX-MM20 20'' DFX-MM24 24'' DFX-MM26 26'' DFX-MM28 28'' DFX-MM30 30'' DFX-MM32 32'' DFX-MM34 34'' DFX-MM36 36'' DFX-MM38 38'' DFX-MM40 40'' DFX-MM42 42'' Note given length are 2 0 8 3 20 23 3 30 49 69 8 3 25 44 60 82 20 226 Nom inal f low ranges f or premium accuracy +/ - 0, % Met er s ize 04" * 06" 50 08" 0" 2" 4" 6" 8" 450 20" 24" 26" 28" 30" 750 32" 34" 850 36" 38" 950 40" 42" 050 * 5 beams design Flow rat e (m3/ h ) 30 65 20 320 520 50 550 750 0 2 0 2750 0 0 0 3 0 5 0 0 0 5 7 00 20 00 27 00 Met er lengt h 6 406 50 8 457 20 508 22 559 24 60 28 7 32 83 450 36 94 40 06 48 220 52 32 56 422 750 60 524 64 626 850 68 727 72 829 950 76 930 80 2032 050 84 230 for face to face flanges Weight Flow rat e ( BPH ) 0 0 3 4 6 7 8 9 2 3 5 7 8 4 7 2 8 20 25 32 40 62 72 84 97 0 25 38 57 70 88 t y pe DFX-MM04 DFX-MM06 DFX-MM08 DFX-MM0 DFX-MM2 DFX-MM4 DFX-MM6 DFX-MM8 DFX-MM20 DFX-MM24 DFX-MM26 DFX-MM28 DFX-MM30 DFX-MM32 DFX-MM34 DFX-MM36 DFX-MM38 DFX-MM40 DFX-MM42 Weight ( k g) # 50 # # 5 70 99 39 86 230 258 295 495 568 646 748 862 95 072 94 355 423 60 88 25 76 232 364 442 504 72 866 035 92 322 553 742 72 3 59 240 328 352 448 # 79 5 25 394 Weight (lb) # 50 # # # 3 54 28 306 40 506 568 770 089 422 646 897 2093 2359 2627 298 330 32 94 275 388 5 660 80 973 0 587 906 2277 2623 2909 347 3833 59 249 528 722 775 986 74 333 473 660 867 /03/204 Page8 Met er s ize Lengt h *

DFX-LV series (5 beams) DFX-LV performance Technical data Nominal flow- ranges f or s t andard accuracy +/ - 0, 25 % (20 ) 4'' 6'' 8'' 0'' 2'' 4'' 6'' 8'' 20'' 24" 26" 28" 30" 32" 34" 36" 38" 40" 42" 50 450 750 850 950 050 Flow rat e ( m3/ h ) 7 40 70 0 60 90 30 390 550 50 450 2 3 3 0 6 7 0 0 0 00 20 20 20 30 30 t y pe Flow rat e (BPH ) 07 252 440 692 6 95 572 950 2453 3459 4088 503 5660 6289 7233 876 99 63 32 Met er s ize DFX-LV04 4'' DFX-LV06 6'' DFX-LV08 8'' DFX-LV0 0'' DFX-LV2 2'' DFX-LV4 4'' DFX-LV6 6'' DFX-LV8 8'' DFX-LV20 20'' DFX-LV24 24'' DFX-LV26 26'' DFX-LV28 28'' DFX-LV30 30'' DFX-LV32 32'' DFX-LV34 34'' DFX-LV36 36'' DFX-LV38 38'' DFX-LV40 40'' DFX-LV42 42'' Note given length are 2 0 8 3 20 23 3 30 49 69 8 3 25 44 60 82 20 226 Nominal f low ranges for premium accuracy +/- 0, 5 % ( 0 ) Met er s ize 4" 6" 8" 0" 2" 4" 6" 8" 20" 24" 26" 28" 30" 32" 34" 36" 38" 40" 42" 50 450 750 850 950 050 Flow rat e (m3/h ) 30 65 20 320 520 50 550 750 0 2 0 2750 0 0 0 3 0 5 0 0 0 5 7 00 20 00 27 00 6 406 50 8 457 20 508 22 559 24 60 28 7 32 83 450 36 94 40 06 48 220 52 32 56 422 750 60 524 64 626 850 68 727 72 829 950 76 930 80 2032 050 84 230 for face to face flanges Weight Flow rat e (BPH ) 0 0 3 4 6 7 8 9 2 3 5 7 8 Met er lengt h 4 7 2 8 20 25 32 40 62 72 84 97 0 25 38 57 70 88 t y pe DFX-LV04 DFX-LV06 DFX-LV08 DFX-LV0 DFX-LV2 DFX-LV4 DFX-LV6 DFX-LV8 DFX-LV20 DFX-LV24 DFX-LV26 DFX-LV28 DFX-LV30 DFX-LV32 DFX-LV34 DFX-LV36 DFX-LV38 DFX-LV40 DFX-LV42 Weight ( k g) # 50 # # 5 70 99 39 86 230 258 295 495 568 646 748 862 95 072 94 355 423 60 88 25 76 232 364 442 504 72 866 035 92 322 553 742 72 3 59 240 328 352 448 # 79 5 25 394 Weight (lb) # 50 # # # 3 54 28 306 40 506 568 770 089 422 646 897 2093 2359 2627 298 330 32 94 275 388 5 660 80 973 0 587 906 2277 2623 2909 347 3833 59 249 528 722 775 986 74 333 473 660 867 /03/204 Page9 Met er s ize Lengt h *

Calibration Performance Monitoring DFX is the only ultrasonic flow meter performing real time comparison between factory calibration & site operating conditions. Featuring in DFX software suite CALIBRATION PERFORMANCE MONITORING CONDITION BASED MONITORING TRACEABILITY DATA VISUALIZATION & PLOTTING DATA LOGGING DIAGNOSTICS PROVING SUPPORT DOCUMENTATION DFX interfacing is easy and cost effective thanks to its Web server and Ethernet link, making skid coissioning, meter health check and auditing operations straightforward. /03/204 Page0 COMMUNICATION

Specifications Compliances Accuracy Flow range Repeatability Uncertainty Installation Safety pressure Metrology Environment Ingress protection Temperature Pressure Viscosity METROLOGY OIML R7- class 0.3 API MPMS ch5.8 M.I.D. 4/22/EC see pages 6 and 7 see pages 6 and 7 0.05% 5 runs with conventional prover loops +/-0.027% at 95% confidence level as per API MPMS 4.8 table A- 0D upstream with recoended flow conditioner + 3D downstream no flow conditioner option, please contact us for details CERTIFICATIONS compliant with all relevant European Counity standards ATEX 94/9/EC II 2 G Exd IIB T6 P.E.D. 97/23/EC ASME B3.3 OIML R7- (PTB-.5-4037579) GOST-M (FR.C.29.006.A N 3866) SIRIM ATS 04/0 MIGAS (4599/8.06/DMT/9) SPRING WMO 423/08 INMETRO (P-0003--36896-0) E.M.C 89/336/EC I.P. 66/67 IEC529 ENVIRONMENT process -55 C to +20 C ambient -55 C to + 55 C Up to bar 0. to cst Density to kg/m3 Materials BODY carbon steel, low temp carbon steel, stainless steel, duplex Flanges ANSI #50 # # Internal full bore Power supply Pulse volume output Counication port Protocols CONV ERTER 0 / 220 VAC 50/60 Hz or 8 / 32 VDC, 0W, isolation V two static relays V 0.2A isolation 0V 0/Base-T IEEE 802.3 Ethernet link RJ45, optional Wifi 802. b & g, optical fiber Range up to 3 km (0 000 ft ) over 2-wires AWG24 twisted pair HTTP, HTTPs, Telnet, SNMP, Modbus TCP Please contact M&T for specifications outside above standard ones /03/204 Page please contact M&T for higher viscosities

Ordering codes A B - C D - E F - G H DFX-MM 2 - A - - 0 Section E Installation conditions Section A Product line DFX-MM or DFX-LV Section B Meter Size 04 4'' / DN 06 6'' / DN50 08 8'' / DN 0 0'' / DN 2 2'' / DN 4 4'' / DN 6 6'' / DN 8 8'' / DN450 20 20'' / DN 24 24'' / DN Standard with recoended f o l w straightener 2 Standard without f o l w straightener 3 Customized Section F Accuracy class DFX-MM standard +/-0.5% 2 premium +/-0.% Section F Accuracy class DFX-LV standard +/-0.25% 2 premium +/-0.5% Section G Documentation Section C Pressure Class A 50# ANSI R.F. Flanges B # ANSI R.F. Flanges C # ANSI R.F. Flanges D Other (please contact us) 0 None Standard 2 Customized Section H Special request Section D Materials of construction Body Flanges Transducers C.S A06 or equ. C.S A05 or equ. Peek / SS 36L 2 L.T.C.S. A333 Gr6 or equ. L.T.C.S. A LF2 or equ. Peek / SS 36L 3 SS 36L or equ. SS 36L or equ. Peek / SS 36L 4 Other Other Peek / SS 36L 0 None S Special request Address METERING & TECHNOLOGY S.A.S. Parc des Propylées II, 5 Allée Prométhée, 20 CHARTRES, FRANCE Tel Fax E.mail Web +33 (0) 965 027 803 / 237 835 446 +33 (0) 237 835 547 info@mnt-sas.com www.mnt-sas.com /03/204 Page2 DFX-MM ordering contacts