Temperature controller- and limiters

Similar documents
EX T... AT. Sensors with switching function. Identification II 2 G Ex db eb mb IIC PTZ 16 ATEX 0024

Operating Instructions

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Control and Terminal Box Type A21-**-*****

HTSB system System overview

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

ILED Aquarius Illuminated Windsock. User Manual

Compact System NRGS 11-2 NRGS Original Installation Instructions English

ILED Dorado. User Manual

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

RVP-R- VAV controller. In explosion-proof version

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Terminal Boxes in Stainless Steel SLS**.T

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Explosion protected terminal boxes type, GHG 72.

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

IQL Helios Area-/Streetlight. User Manual

Solenoid Valve Island Type 3965

EX GHL ALAT Connection fitting

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

EX-REPAIR AND MAINTENANCE RECEPTACLES

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Technical Data. Dimensions

Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Surface-mounting Thermostats Series ATH-SW

Ex m Solenoid Operator Type 0519

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Electronic Limit Switch Type

Instruction manual and installation guide Traction sheave brake TSB TSB

Armoured / Un-armoured Cable Gland

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

For air / gas dampers and control valves of oil or gas burners

OPERATING INSTRUCTIONS

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

Measuring insert for process resistance thermometer

Solenoid Valves Type 3963

Level limit switch Series RF 3000 Selection list

SITRANS P measuring instruments for pressure

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Explosion and flame-proof cast iron electric motors

Continuous level measuring system NB 4000 Selection list

SATRON VT Pressure Transmitter

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Electronic Ballast EVG 2000-T

Panel-mounted Thermostats

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

ZE motor-protective relay Overload monitoring of EEx e motors

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

KINAX SR 709 Transmitter for Position Feedback

Material pressure (bar) (Cv (US) kv x 1,2 Seat

PC T8 PRO, W T8 fluorescent lamps

Series 3730 Electropneumatic Positioner Type

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

ZB0050 / ZB0051 ZB0070 / ZB0071

SATRON VDt Differential Pressure Transmitter

Sentronic PLUS 614 Series

DATAFLEX 110/... Torque Measuring Shaft Operating/Assembly instructions DATAFLEX. Torque measuring shaft type 110/

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Solenoid coil for control in potentially explosive areas Type BZ

Operating Instructions

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

I Ex-safety switches I

Operating Instructions

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Zone 1 Linear Range - Installation Guide

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Type MR 783 Magnetic level switch

Mini temperature switch Stainless steel switch enclosure Model TXS

SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08

Solenoid coils VACF Type codes

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

JUMO dtrans p20 DELTA

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Actuators for air dampers and control valves of oil burners

SATRON VTe pressure transmitter

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

Transcription:

65189 WIESBADEN Rüdigerstrasse 15 Telefon (0611) 761393 Telefax (0611) 711462 Temperature controller- and limiters For the assembly within the ex range after ATEX ZELM03ATEX0171 ZELM03ATEX0172X 0344 Type of protection EX II 2 GD Ambient temperature -40 C - +60 C Measuring range 0 C - 50 C 0 C - 100 C 0 C - 300 C Nominal voltage 16 A Nominal curren 400 V Protection IP 65 Temperature limiter Temperature controller Ex TBK... /.. KA Ex TRK... /.. KA Temperature limiter modul Temperature controller modul Ex TBK... /.. KAU Ex TRK... /.. KAU Temperature limiter -controller combination Ex TBK/TRK... /.. KA Malux Finland Oy, P.O.Box 69, FIN-06151 PORVOO, Finland Phone: +358 (0)19 57 45 700, Fax: +358 (0)19 57 45 750, www.malux.fi

1.0 BASIC DEVICE The pressure - resistant enclosed switching element is inserted into a housing in the type of protection "increased safety". The housing material is polyester. The switching element of the limiter has a manual resetting mechanism. 1.1 RANGE OF APPLICATION The temperature controller and/or temperature limiter is intended for being used in industrial plants and serves for the temperature measurement of surfaces, air or in protective pipes for general on-off controls. In particular it is intended for electrical resistance trace heating and protection cabinet heaters in explosive atmospheres of zone 1 or 2. 1.2 GENERAL DESCRIPTION Temperature changes are detected by the temperature sensor and transferred over the capillary and diaphragm directly to the precision micro switch. The switching temperature can be adjusted after removing the housing cover by a handwheel with a thermometric scale steplessly. Temperature setting and limiter resetting may also be made under voltage (strip terminal taken off). The illustration of the contact in the connection diagram implies that the sensor temperature is lower than 5% and/or min. 5 K than the temperature set at the setpoint element. The devices have only one setpoint element and a two-way contact (change-over switch) each. The capillary tube limiter is suitable for temperatures up to 300 C and 16A/400V. 1.3 TEMPERATURE LIMITATION The limiter was originally a safety limiter, which was equipped with an adjustable setpoint and because of that it is no limiter. This function is however safety-relevant for the practice of electrical resistance trace heating, since also safety limiters of other design loose their function by corrosion or freezing up, as a squeezed capillary generally leads to inoperability of the capillary tube limiters. Due to the adjusting possibility of the desired value the operability can be checked at any time at temperatures over 0 C. 2.0 GENERAL TECHNICAL DATA Measuring range: Capillary tube length: 0-50 C, 0-100 C and 0-300 C 1 m and 3 m Contact Contact rating: max: 4000 VA Switching power: min: 10 V, 0,1 A Nominal voltage: 16 A ~ Nominal current: 400 V ~ 1

Type of protection: IP65 II 2 GD Enclosure dimensions: Material: Mounting dimensions: Ambient temperature: 160 x 75 x 75 mm Polyester 148 x 45 mm - 40 C - +60 C** **Usual continuous operating temperature of the cable >90 C Adjustment range 0..50 C 0..100 C 0..300 C Cut off accuracy* + 1K + 1,5K + 4,5K Differential gap + 1,5K + 3K + 9K max. sensor temperature 70 C 120 C 320 C sensor dimensions 6x250mm 6x135mm 4x175mm Capillary (V4A) 1 / 3 m 1 / 3 m 1 / 3 m * Delivery status. In dependence on the ambient temperature this value can double. Confirmity: the essential requirements of the directives by application of the following harmonized standards: EN 60079-0: 2007 EN 60079-1: 2004 +Korr. 2006 EN 60079-18: 2004 EN 61241-0: 2006 EN 61241-1: 2004 +Korr. 2006 Cable gland: M 25 brass-ni (-40 C - 100 C) box 160x75 M 32 plastic (-40 C - 70 C) box 160x160; 160x260; 160x360 PG 9 steel (-40 C - 100 C) modul EC - type Examination Certificate: ZELM 03 ATEX 0171 (single and combination) Marking: 0344 II 2 GD II2G Ex de mb IIC T6 bzw T5 bzw. T4 II2D Ex td A21 IP6x T100 C EC - type Examination Certificate: ZELM 03 ATEX 0172X (modul) Marking: 0344 II 2 G II2G Ex d mb IIC T6 bzw T5 bzw. T4 2

2.1 FERTIGUNGSNUMMER xxxx / 03.03 Year Month Serial number 2.2 MODEL CODE For Limiter Ex T_ K/... /... /.. KA _ B = limiter / R = controller Kombinationsgertät (for example TBK/TRK see4.0) _Temperature range of adjustment (for example 300 for 0-300 C) capillary length (for example 3 for 3 m) s = with VA cable protective tube / o = no VA cable protective tube 2.3 ORDER DATA The standard type designation is the complete ordering designation for metal cable glands. If plastic cable glands are desired, this must be mentioned in plain text. Shortcuts: R = limiter B = controller The first number after the shift is the effective range of the basic device: 5 = 0 to +50 C 1 = 0 to +100 C 3 = 0 to +300 C The second number after the shift specify the length of the capillary tube system: 1 = 1m 3 = 3m 5 = 5m The third number after the shift specify if there is an cable protective tube or no cable protective tube. s = Schutzschlauch (Kapillarrohrschutz (VA Wellschlauch) gegen Knickbelastungen bei der Montage) o = ohne Schutzschlauch 3

ASSEMBLY INSTRUCTION 3.0 INSTALLATION For installation/operation the EN 60079-14 FF and respectively the valid installation regulations as well as this instruction manual shall be observed. The devices may not be thrown or dropped. If a damage has been recognized, the devices shall be sent back for examination. The capillary may not be stressed by external loads, e.g. other equipment. This applies for storage as well as during transport. The capillary may not be draggled, folded or squeezed, at least a bending radius of 15 mm should be ensured. The sensor may not be deformed. The smallest deformation may lead to an misadjustment and so a switchpoint deviation of the temperature preset at the interior adjuster might occur. The measured temperature corresponds to the average temperature value of the capillary tube sensor. The temperature of the capillary and the switching element has a very small influence on the switching behaviour. According to DIN the sensors may be warmed up to 20% over the measuring temperature at maximum without leading to a misadjustment of the switching point. Warming above this temperature should be avoided. All installations have to be verified for functionality before commissioning and after assembly at temperatures over 0 C. The contact of the switching element is a heavy current contact. In case of too low switching capacity (below 10 ma, 12 V) high contact resistances may accure and inoperability may be the result. This error can be repaired by e.g. switching a lamp with 50 Watts 230 V. Afterwards the equipment can be used again for small contact ratings which are higher than 10 ma and 12 V. The interconnection of individual certified components to a new equipment, is conform to a new unit, with new ignition risks, resulting in a new examination of the critical parameters such as the max. temperature. 3.1 ASSEMBLY The local assembly regulations of the operator* and the applicable standards, like EN 62086-2 and EN 60079-14 have to be obeyed. In case of doubt consultations with the supervising body or a notified body may be useful. The special conditions of the EC - type Examination Certificate have to be obeyed. The fixation of the sensor on piping shall be carried out with tension band or adhasive tape. No stress may be exerted on the sensor system. The sensor may not be opposed to stress during operation, too. For the assembly of the devices on a mounting plate there are designed four bores in the housing of the temperature controller and/or limiter. With those bores the devices can be fixed using two M4 (M5) screws DIN 84. The grid dimension for mounting is shown in the handout. Concerning installation of the devices and in particular the connection cable the necessary rules and standards (e.g. EN 60079-14 and EN 62086-2) shall be obeyed. The sealing for the cable glands must be selected appropriate to the cable diameter. 3.2 PROJECT ENGINEERING The switching hysteresis depends on the adjustable temperature range final value. On - off control are producing heat waves with dead times in the heating system, so that in the in-regulated condition min. and max. temperatures are resulting, whose difference usually is more than the triple of the switching hysteresis. Heated objects exhibit smaller variations in temperature depending on there thermal inertia (mass, material). 4

3.3 CONNECTION DIAGRAM schw br δ bl P 1 E 2 3 3.4 SAFETY MEASURE As safety measure for the heating circuit grounding (potential equalization) is essential. Due to in many cases long connection cables and the resulting capacitive residual currents, which may increase significant by humidity saturation of the isolation, earth-leakage circuit breakers with 300mA should be used. It should be kept in mind that dependent on the brand of the Residual Current Device these devices can respond differently to capacitive residual currents. 3.5 OTHER The equipment is maintenance free. Disassembly takes place in reverse order of the assembly. Due to the small heavy metal portion defective devices shall be disposed as hazardous waste. A repair of the devices is not possible because of the properties of the switching element. All other repairs shall only be carried out in the factory of the manufacturer. a. In case of disregarding of the assembly guidelines the warranty expires. b. The basic devices (devices without terminal box) are irreparable with exception of the capillary. These must only be replaced by the manufacturer. An interference is not permissible. c. Only qualified personal shall perform installations. d. The switching hysteresis produces heat waves in the application and contribute to an enlargement of the vari ations in temperature. e. Local the replacement of the basic devices (devices without terminal box) is restricted to persons which were authorized by Erich Ott. 3.6 MAINTENANCE The valid regulations for repair / maintenance / examination of the EN 60079-14 have to be considered. The devices themselves are maintenance-free. 5

4.0 SPECIAL DESIGNS according to EC - type Examination certificate ZELM 03 ATEX 0171 Different users need several independent temperature limiters, controllers or guards at one object. Therefore we offer different combinations of basic devices in a terminal box and/or a basic device in a larger terminal box. In these cases it is necessary to deliver the basic devices as spare parts. Three different terminal boxes can be used for the installation of 1 to 4 basic devices, equipped with clamps for 2.5 (4) mm² and cable glands of M 32 or smaller. Number of special devices 1 2 3 4 Housing size 160x160x90 260x160x90 360x160x90 360x160x90 Mounting dimensions 140x110 240x110 340x110 340x110 Number of cable glands 2 x M32 3x M32 4 x M32 4 x M32 4.1 SPECIAL DESIGNS according to EC - type Examination certificate ZELM 03 ATEX 0172 X The basic devices are designated for retrofitting or for the installation into a control with separate EC - type Examination certificate. The EC - type Examination certificate ZELM 03 ATEX 0172 X and the mentioned conditions for safe use have to be considered. The type designation according to page 2, under point 2.2 is supplemented with an additional "U". 4.2 MODEL CODE The sequence of the abbreviations corresponds to the sequence in which the basic devices are mounted. One character is always followed by two numbers. The first module determines the type designation. R or B for the first module are thus already given Shortcuts: R = controller (Regler) B = limiter (Begrenzer) 6 The first number after the character indicates the measuring range of the basic device: 5 = 0 to 50 C 1 = 0 to 100 C 3 = 0 to 300 C

The second number behind the character indicates the length of the capillary tube system: 1 = 1m 3 = 3m 5 = 5m Depending on the version the model code consists of three up to twelve indications. Combinations with the number 5 are only available in exceptional cases and must be asked for. Connection diagrams according to draft Point.: 4.4 * smaller cable glands on request 4.3 TECHNICAL DATA MODUL Cable gland modul: PG9 steel (-40 C - 100 C) EC - type Examination Certificate: ZELM 03 ATEX 0172X (modul) Marking: 0344 II2G Ex d mb IIC T6 bzw T5 bzw. T4 Confirmity: the essential requirements of the directives by application of the following harmonized standards EN 60079-0: 2004 EN 60079-1: 2004 EN 60079-18 : 2004 Other technical details are analog to Point 2.0 4.4 CONNECTION DIAGRAM TRK KAU KA x dimensions in brackets apply for housings of 160x260x90 mm 1. blue 2. black 3. braun 7 If the assembly instructions are not maintained, the warranty expires.