Cisco Beacon Point Module

Similar documents
Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

Installing and Removing Power Supplies

Virginia Tech Research Center Arlington, Virginia, USA

Portable Pack USER MANUAL

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Soffit Application Sound Enclosure

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Switch Installation. Preparing for Installation. Warnings CHAPTER

IBM CMM Quick Reference Guide

INSTALLATION INSTRUCTIONS

Cisco Nexus 7700 Switches Environment

Virginia Tech Research Center Arlington, Virginia, USA

M40e and M160 Cooling System Installation Instructions

YOGEV. Hydro-Power Unit. Installation and Operation Guide

ADDRESSABLE SELF TESTING NON MAINTAINED SPOT LIGHT EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED

GPS Steering System Installation Manual

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Installation Guide Current Ford F-250 & Ford F-350 Super Duty. Product Code: 109 & 119

Installation Instructions - D-Series Warming Cabinet Instruction Door for Hinge UseReversal (Glass and Stainless Steel Doors)

SE-B2, B3 & BXL Sound Enclosures

INSTALLATION GUIDE. AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

HP Modular Cooling System 200/100 Options Installation Guide

SMART BUILDINGS AND ENERGY EFFICIENCY

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

Smart Door Lock. Manufacturer's Installation Guide

INSTALLATION GUIDE STANDARD PRODUCT CODES:

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Service Bulletin

SAM Series 2-Wire and 3-Wire Clock

Overview. Chassis Packaging

Rear Roll-up Door. W-Series

Smart Wi-Fi Sprinkler Timer and Flow Meters

Replacing the X Axis Belt

Installation Instructions Table of Contents

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa

INSTALLATION GUIDE DODGE PRODUCT CODE:

Steeda S550 Mustang Street Short Throw Shift Lever Installation Instructions: &

Steeda S550 Mustang Street Short Throw Shift Lever Installation Instructions For Part:

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Uninterruptible Power System

Smart-UPS On-Line Lithium-ion UPS 230V

Transmission Overhaul Procedures-Bench Service

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

LED Recessed Troffer Retrofit Kit

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

I. Introduction - basic information 3 II. Installation into a vehicle 3. III. Attachments 9

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

Hardware Install Guide

Installing the Switch Chassis

ARION: 19 EIA-310E Standard Enclosure

ChargePoint Gateway Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

Virginia Tech Research Center Arlington, Virginia, USA. PPT slides will be available at

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

ET9500 BEMS Interface Box Configuration Guide

series USER MANUAL

Unity output power factor single-phase double-conversion, online UPS with advanced management features

Note: If anything is damaged or missing, contact your customer representative immediately.

Installation Instructions

Installing the Switch

Technical Support (707)

Automotive Application ET01 Software Revision A 12/06

IP54 Gasket Kit VGA-IP54K-IC VGA-IP54K-IC78. Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

SCION tc SECURITY (V5) Preparation

Pneumatic Isolation Module

TOYOTA SOLARA EC REARVIEW MIRROR Section I - Installation Preparation

Installation Instructions PowerBoard Automatic Retracting Running Board

Installation and Operation Instructions BMW 3 E93 Convertible Comfort Module

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Uninterruptible Power System

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Steeda S550 MT-82 Tri-Ax Race Short Throw Shifter Installation Instructions For Parts: ,

SAVE THESE INSTRUCTIONS

GPS AutoSteer System Installation Manual

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Attitude And Direction

Door Interlock Switches

Steering Angle Sensor (SAS) Replacement on Vehicles Equipped with Electronic Stability Control (ESC)

Bruker BioSpin NMR CASE. Installation Manual. Version. NMR Spectroscopy. think forward

Titan Safe Owner s Manual

Cybex Arc Trainer Owner s & Service Manual. 7 - Service

Do not have any open flame or heat sources close to the installation

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

TOYOTA TACOMA EC REARVIEW MIRROR Preparation

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

INSTALLATION INSTRUCTIONS

Nuvation Low-Voltage BMS

ComfortPoint Programmable Lon, VAV/Unitary Controllers

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

SITRANS F Coriolis Flowmeters SITRANS FCS400 sensor Quick Start

RS485 Terminator Board (pn SP)

Installation & Programming Manual. Quick Reference

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Transcription:

Overview of, page 1 Installing a Cisco Beacon Point, page 4 Overview of About (AIR-RM-VBLE2-K9=) is a Bluetooth Low Energy beacon module that is mounted on supported access points. The APs now has the ability to provide Wi-Fi access as well as act as BLE Beacons for Bluetooth-integrated clients. With, smart client devices can receive different signal strengths from the multiple integrated beacon to improve location calculations. Deploying Bluetooth-integrated APs is similar to Wi-Fi location based service solution. The recommended density for deploying the Bluetooth-integrated APs is one per 1500-to-2500 sq.ft. The optimum height for a Bluetooth-integrated APs is 13 to 15 ft (3.9 to 4.6m). Cisco Beacon Center requires the correct physical orientation, position, and height of Bluetooth-integrated APs for providing clients with indoor navigation, turn-by-turn guidance and proximity messaging for best indoor navigation experience. Bluetooth-integrated APs connect with Cisco Beacon Center over the internet using secure HTTPS protocol. Bluetooth-integrated APs, each have a unique IP address just like any enterprise grade networking device. Bluetooth-integrated APs should connect with Cisco Beacon Center for management and control. For 1

About Bluetooth-integrated APs to communicate with the Cisco Beacon Center, outbound communications from to the cloud service using port 80 (TCP) and 443 (TCP) must be possible. Figure 1: Front View (AIR-RM-VBLE2-K9=) Table 1: Number 1 2 3 4 Description pointing direction. Host interface connector to access point. Draws power from the host bus interface with the access point. swing arm latch screw. Decorative gasket: Retain the gasket when Cisco Beacon Point Module is attached to AP3802I Remove and discard the gasket when Cisco Beacon Point Module is attached to AP3802E. 5 6 LED status indicator. A multicolor system status LED on the front-face of the unit. Note that you can vary (dim) the strength of this LED from the cloud settings. Serial Number, MAC, Claim code labels 2

Features Number 7 8 Description Regulatory labels Console port (covered with mylar label at manufacturing). Supported Access Points The can be attached to the following APs: AP3802I AP3802E Features comes with the following features: Table 2: Hardware Feature Summary Feature LED indicators Power Options Description A multicolor system status LED on the front-face of the unit. Note that you can vary (dim) the strength of this LED from the cloud settings. Draws power from the PCIe bus interface with the access point. Technical Specifications Table 3: Technical Specifications of Feature Dimensions (of APs with Cisco Beacon Point Module) Weight Description 285 mm x 275 mm x 61 mm 11.2 in. x 10.8 in. x 2.4 in. 1.4 kg (3.0 lbs) 3

Model Number Feature Environmental Power Dissipation Description Fanless operation; passive cooling Nonoperating (storage) temperature: 30 to 70 ( 22 to 158 ) Operating temperature: 0 to 40 (32 to 104 ) Operating humidity: 10 to 90% (noncondensing) Operating altitude: 10,000 ft (3048 m) Less than 6 W Model Number is available in the following model: Table 4: Model Number Product ID AIR-RM-VBLE2-K9= Description can be mounted on supported APs. Note that while the must be attached to supported APs, the Cisco Beacon Point itself is a standalone device. Installing a Cisco Beacon Point Unpacking the Step 1 Step 2 Step 3 Step 4 Unpack and remove and accessories from the shipping box. Return the packing material to the shipping and save it for future use. Record the Serial Number, MAC address and Claim code of the. You will need this information later to claim the from Cisco Beacon Center. Verify that you have received the following items. If an item is missing or is damaged, contact your Cisco representative or reseller for further instructions. 4

Unpacking the AIR-AP-BRACKET-2 There is no need to replace an existing bracket with the one in the packaging. Figure 2: AIR-AP-BRACKET-2 Locking Lever Designed to lock the AP to AIR-AP-BRACKET-2 when the Cisco BPM is being pushed into the AP. Figure 3: Locking Lever 5

Attaching Locking lever to AIR-AP-BRACKET-2 Strength Bracket with two screws. Figure 4: Strength Bracket Attaching Locking lever to AIR-AP-BRACKET-2 If the AIR-AP-BRACKET-2 is already attached to the ceiling and has an AP installed, uninstall the AP and remove ethernet cables. If AIR-AP-BRACKET-1 has been used, it must be detached and replaced with AIR-AP-BRACKET-2. If this is a fresh installation of an AP, follow these instructions to attach the locking lever to the AIR-AP-BRACKET-2 before installing it on to the ceiling. Before You Begin You will need: Locking lever and supplied screw Philips screwdriver AIR-AP-BRACKET-2 Align and slide the Locking lever with the AIR-AP-BRACKET-2 until the grounding hole of the AIR-AP-BRACKET-2 aligns with the rivet hole of the Locking lever. Now using the screw supplied, attach the Locking lever to the AIR-AP-BRACKET-2. 6

Installing and APs Separately Installing and APs Separately Before You Begin Ensure that the Locking lever is attached to the AIR-AP-BRACKET-2 as per the instructions in Preparing AIR-BRACKET-2 for. Remove the gasket piece when installing the Cisco AP 3802E. Step 1 Attach the Strength bracket to the AP with the two screws provided. Ensure that you use the appropriate screw driver size so as to not to strip the cross grooves. Apply enough pressure to the screws to drive them all the way into the AP until the bracket is firmly attached to the AP. Step 2 Leave the locking lever in the unlocked position. 7

Installing and APs Separately Step 3 Step 4 Step 5 Now install the AP to the AIR-AP-BRACKET-2 as usual, ensuring that the AP snaps into the four holes of the bracket. Push the locking lever into the locked position to secure the unit. This secures and locks the AP in position during the installation of the in the next step. Now install the onto the AP. Loosen the captive screw on the handle and swing it open clockwise and all the way to the six-o-clock position. Slide the on to the AP until it snaps firmly on to the AP bracket, with the two dimples on snapping into the middle of the two bracket holes. 8

Installing the to the AP and Mounting as a Combined Unit Step 6 Step 7 Step 8 Close the hinged door of the. Screw in the inset screw on the to secure the hinged door to the rest of the module. Claim the on the Cisco Beacon Center. You can observe the orientation of the Cisco Beacon Point Module on the Cisco Beacon Center. See the Cisco Beacon Center Configuration Guide. Installing the to the AP and Mounting as a Combined Unit Before You Begin Ensure that the Locking lever is attached to the AIR-AP-BRACKET-2 as per the instructions in Preparing AIR-BRACKET-2 for. Remove the gasket piece when installing the Cisco AP 3802E. Step 1 Attach the Strength bracket to the AP with the two screws provided. Ensure that you use the appropriate screw driver size so as to not strip the cross grooves. Apply enough pressure to the screws to drive them all the way into the AP until the bracket is firmly attached to the AP. 9

Installing the to the AP and Mounting as a Combined Unit Step 2 Leave the Locking lever in the unlocked position Step 3 Step 4 Now install the onto the unmounted AP. Loosen the captive screw on the Cisco Beacon Point Module handle and swing it open clockwise and all the way to the six-o-clock position. Slide the Cisco Beacon Point Module into the AP until it snaps firmly on to the AP bracket, with the two dimples on snapping into the middle of the two bracket holes. Close the hinged door of the. 10

Uninstalling Step 5 Step 6 Step 7 Step 8 Screw in the inset screw on the to secure the hinged door to the rest of the module. Install the AP (installed with the Cisco BPM) on to the AIR-AP-BRACKET-2 as you would normally do, that is, align the screws at the base of the AP with the key holes of AIR-AP-BRACKET-2 and slide the AP onto the slots until it snaps into place. Push in the locking lever into the locked position to secure the unit. This will ensure safety during future unmouting. Claim the on the Cisco Beacon Center. You can observe the orientation of the Cisco Beacon Point Module on the Cisco Beacon Center. See the Cisco Beacon Center Configuration Guide Uninstalling To uninstall the AP, unlock the locking lever, and then pull the AP out of the bracket. To remove the and keep the AP, ensure that the Locking lever remains in the locked position. 11

LEDs LEDs Figure 5: Face of 1 2 Access Point Status LED Status LED Note Small variations in color intensity and hue will be present from unit to unit. This is within the normal range of the LED manufacturer s specifications, and is not a defect. Cisco Beacon Point status LED indicates various conditions, which are described in the table below: Table 5: Cisco Beacon Point LED Status Indication LED Color Blinking red Alternating green and yellow White Green Blinking orange Alternating green and purple Solid red Cisco Beacon Point LED Status Module beginning a boot reset. Module booting. Module connecting to Cisco Beacon Center. Module configured by Cisco Beacon Center. Module upgrading software. Module being located on Cisco Beacon Center. Module failure mode. 12

LEDs 13

LEDs 14