Mounting Installation Instructions NKQ, GK

Similar documents
Mounting Installation Instructions LM, NM, AM, GM

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

Table of Contents PAGE General Mounting Standard Reversible Clamp Linear Rotary Retrofit Brackets...275

Versatile and Powerful

LF Series Spring Return Direct Coupled Actuator

Minimum 27 in-lb torque

Versatile and Powerful

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 27 in-lb Torque

AF Series Spring Return Direct Coupled Actuator

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

Mounting Installation Instructions ZG-JSL(A)

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Installation Instructions

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Installation Instructions

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

GM Series Direct Coupled Actuator

Torque min. 35 in-lb, for control of air dampers

Installation Instructions

LF Series Spring Return Direct Coupled Actuator

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

LF Series At A Glance

AF Series Spring Return Direct Coupled Actuator

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S

AF24-MFT95 US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for Use with Honeywell Electronic Series 90, or a 0 to 135Ω input

Minimum 18 in-lb Torque

AM Series Direct Coupled Actuator

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Belimo is the Worldwide Leader in Fire and Smoke Actuation

FSAF24(-S) US, FSAF120(-S) US

ZG106 or ZG 107 bracket

2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington

BELIMO CONTROLS

Invensys Energy Solutions 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL United States of America

G7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim

SAX Electronic Valve Actuator

Product Cross Reference

MF4E MF4E

NV Direct Coupled Globe Valve Actuator

G3 (D) 3-way Globe Valve, Bronze Trim

Butterfly Valve Retrofits

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

G6 C(S)(LCS) 2-way Pressure Compensated Flanged Globe Valve

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Globe Valve Retrofits

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

G780, 3-Way, Mixing Flanged Globe Valve

Globe Valve Retrofits

F6 Series 2-Way, Victaulic Butterfly Valve

Butterfly Valve Retrofits

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

MA40-704X Series MA41-707X Series MA41-715X Series

G7100S, 3-Way, Mixing Flanged Globe Valve

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Globe Valve Retrofits

M9216 Series Electric Spring Return Actuators

35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML6161, ML7161, ML6174, ML7174

Powers TM Controls EA 338 Electronic Actuator

Electronic Globe Valves

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

MF Series MF Series MF Series

Technical data. Safety notes

SAV Electronic Valve Actuator

Actuators for heating, ventilation, air-conditioning. Mounting Methods Guide

SAX Electronic Valve Actuator

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

Butterfly Valve Retrofits

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

SmartX MF and MS

MF Series MS Series

Commercial Actuator Selection Chart Non-Spring Return

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

SKD U Electronic Valve Actuator

MS Series MS Series MS Series

AM-676, AM , AM-690-R, AM-692, AM-693-R, AM-762, and AM-763

Electronic Pressure Independent Valves (epiv)

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

MF /MS Series

M436A/M836A,B Damper Motors

Excel 10 W7751H SMART VAV ACTUATOR BEFORE INSTALLATION INSTALLATION

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

M9208-xxx-x Series Electric Spring Return Actuators

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Direct-Coupled ControlSet Actuators (120/180/320 in-lbs.) Installation Guide 2-7/16"

Transcription:

7-0000.B Mounting Installation Instructions NKQ, GK General Information Preliminary steps. Belimo actuators with NEMA ratings should be mounted indoors in a dry, relatively clean environment free from corrosive fumes. If the actuator is mounted outdoors, a protective enclosure must be used to shield the actuator.. For new construction work, order dampers with extended shafts. Instruct the installing contractor to allow space for mounting the Belimo actuator on the shaft. For replacement of existing gear train actuators, there are two options: A. From a performance standpoint, it is best to mount the actuator directly onto the damper shaft. B. If the damper shaft is not accessible, mount the non-spring return actuator with a ZG-GMA crankarm kit, and a mounting bracket (ZG-00, ZG-0, ZG-0, ZG-0). Direction of Rotation Switch Please refer to the appropriate product literature for detailed installation information. Reference Mounting Methods Guide Wiring Guide Damper Application Guide Electronic fail-safe actuators have a reversing switch on the cover. Switch position indicates start point. For the non-spring return, with the switch in position, the actuator rotates clockwise with a decrease in voltage or current. With the switch in position 0, the actuator rotates counterclockwise with a decrease in voltage or current. The electronic fail-safe rotates clockwise when the switch is in the position and power is applied to wire #. When power is applied to wire # and # for the - version, the actuator rotates counter clockwise. Rotating the switch to 0 reverses the control logic. 0 VDC VDC VDC 0 VDC During checkout, the switch position can be temporarily reversed and the actuator will reverse its direction. This allows the technician a fast and easy way to check the actuator operation without having to switch wires or change settings on the thermostat. When the check-out is complete, make sure the switch is placed back to its original position.

Installation Instructions Quick-Mount Visual Instruction for Mechanical Installation C A B D 0 See next page for standard mounting instructions. A* B C** D NKQB / to.0 <.0" to 7 ft-lb GKB / to.0 <.0" 0.8 to 7 ft-lb *NKQB clamps have an insert that self-centers on the following diameter shafts: / (default), / and.0. GKB clamps have an insert that self-centers on / diameter. Without the insert, the clamp centers on.0" **Shorter with reversible clamp for the GKB Note: If an auxiliary switch or potentiometer is used while the clamp is reversed, part number (P/N) 8-0000 is needed to connect the clamp to the auxiliary device.

Mounting Installation Reversible Clamp Quick Mount (GK) Center the anti-rotational bracket in the slot. Standard Mounting. Turn the damper shaft until the blades are fully closed.. Slip the actuator s universal clamp over the damper shaft. Make sure that the duct and the controls on the cover are accessible. Place the actuator in the desired mounting position. ➁ Hand tighten the two nuts on the actuators universal clamp.. Disengage the actuator gear train by pressing the manual override button and rotate the clamp until centered. ➁ Slide the anti-rotation strap up under the actuator so it engages the actuator at the center of the cutout. Bend the bracket as needed to support the rear of the actuator. Secure to ductwork with self-tapping screws (No. 8 recommended).. Loosen the nuts on the universal clamp. Press the manual override button and rotate the clamp to about from the closed position (/ to /8 between stop and clamp). ➁ Tighten the two nuts on the universal clamp with a 8, 0 or mm wrench (see table, column D on page for required torque).. Snap on the reflective position indicator. ➁ Adjust end-stops, if required. Mount actuators indoors. If mounted outdoors, use approved protective enclosure. The damper is now fully closed but the actuator is from fully closed. This is called pre-loading the actuator. When the actuator is powered and sent to the closed position: it will put its full torque on the shaft compressing the edge and blade seals. This ensures that the damper will meet its leakage rating. The actuator is electronically protected from overload and will not be damaged. Testing the installation without power. Disengage the gear train with the manual override button and move the shaft from closed to open to closed. Ensure that there is no binding and that the damper goes fully open and closes with of actuator stroke left.. Correct any problems and retest.

Wiring On/Off, Floating Point Torque (based on in-lb per sq. ft) Supply Consumption Fail-Safe 0 in-lb [0 Nm], Apprx. sq. ft. in-lb [ Nm], Apprx. sq. ft. Motor Drive (Default) VDC +0%/-0% VA rating Wattage running (holding) Airside Products GKB(X)- 0 () NKQB(X)- () Seconds Wiring NKQ GK VAC Transformer Blk () Common Red () + W_B W99_0 a open a closed a Wht () + The indication of direction is valid for switch position. 0 On/Off Floating Point or On/Off control 8 Provide overload protection and disconnect as required. Actuators may also be powered by VDC for a V power supply. Meets culus requirements without the need of an electrical ground connection. Contact closures A & B also can be triacs. A & B should both be closed for triac source and open for triac sink. Note: Floating Point not available on NKQ series

Wiring to 0 VDC Torque (based on in-lb per sq. ft) Supply Consumption Feedback Fail-Safe Airside Products GKB-SR, GKX-SR NKQB-SR, NKQX-SR in-lb [ Nm], Apprx. sq. ft. 0 in-lb [0 Nm], Apprx. 90 sq. ft. Motor Drive (Default) VDC +0%/-0% VA rating Wattage running (holding) 0 () () TO 0 VDC Seconds Wiring VAC Transformer W to 0 ma Control Signal ( ) (+) Ω 00Ω Blk () Common Red () Hot + Wht () Y Input, to 0V Org () U Output, to 0V To other actuators 0 Provide overload protection and disconnect as required. Actuators may be connected in parallel. consumption and input impedance must be observed. Actuators may also be powered by VDC. The ZG-R0 00Ω resistor converts the to 0 VDC control signal to to 0 ma, up to actuators may be connected in parallel. Only connect common to neg. ( ) leg of control circuits.

Wiring MFT Torque (based on in-lb per sq. ft) Supply Consumption Feedback Fail-Safe in-lb [ Nm], Apprx. sq. ft. 0 in-lb [0 Nm], Apprx. 90 sq. ft. Motor Drive (Default) VDC +0%/-0% VA rating Wattage running (holding) -0 VDC (default) VDC Variable (0 to 0 VDC) Airside Products GKX-MFT 0 () NKQX-MFT () - Seconds Wiring VDC/-0 ma VAC Transformer Control Signal to 0 ma or to 0 VDC ( ) (+) Ω 00Ω / watt 7 Blk () Common Red () + Hot Wht () Y Input, to 0V Org () U Output, to 0V MFT Floating Point (GK only) VAC Transformer to 0 VDC Feedback Signal A B 8 Blk () Common Wht () Hot + Wht () Y Input 9 Pnk () Y Input Org () U Output to 0V MFT W99_B PWM On/Off VAC Transformer (AC only) Position Feedback VDC VAC/DC Transformer Position ( ) ( ) (+) a Blk () Common Red () + Hot Wht () Y Input Org () U Output MFT Blk () Common Red () Hot Wht () Y Input Pnk () Y Input MFT Provide overload protection and disconnect as required. Actuators may be connected in parallel if not mechanically mounted to the same shaft. consumption and input impedance must be observed. Actuators may also be powered by VDC Provide Position overload feedback protection cannot and be disconnect used with a as Triac required. sink controller. The actuator internal common reference is not compatiable. Actuators may be connected in parallel if not mechanically mounted to the same shaft. consumption and input impedance must be Control observed. signal may be pulsed from either the Hot (Source) Actuators or Common may also (Sink) be powered VAC line. by VDC. 7 Position feedback cannot be used with a Triac sink controller. ZG-R0 may be used. The actuator internal common reference is not compatiable. 8 Control Contact signal closures may be A pulsed & B also from can either be triacs. the Hot A (Source) & B should both or Common be closed (Sink) for triac VAC source line. and open for triac sink. 7 ZG-R0 may be used. 9 For triac sink the common connection from the actuator Contact closures A & B also can be triacs. A & B should 8 both must be closed be connected for triac to source the hot and connection open for triac of the sink. controller. For triac sink the common connection from the actuator Note: 9 Floating Point not available on NKQ series must be connected to the hot connection of the controller.

Operations Mechanical Features Manual Override The Belimo non-spring return actuators have a black, manual override button located on the top of the housing. Press this button and the gear train is disengaged so the damper shaft can be moved manually. Release the button and the gear train is re-engaged. Use the manual override to test the installation without power. For tight shut-off the damper should close with of actuator stroke left. Manual override button Mechanical Angle of Rotation Limiting The adjustable stops are needed when there is no damper stop or if you want the damper to stop rotating before it reaches its stops. The non-spring return actuators can be indefinitely stalled in any position without harm.. Loosen the two end stops with a No. Phillips head screwdriver being careful not to unscrew the captive nut under the slot.. Move the stops (in. steps) to the desired position and re-tighten the screws. Setting the Fail-Safe Position Belimo's new Electronic Fail-Safe Actuators allows the user to set the fail position (0-00% in 0% increments). To set the position of the fail-safe, rotate the cover away from the fail-safe switch. Turn the switch to the desired positon. To set with PC Tool, turn the switch to PROG FAIL-SAFE. When done, rotate the cover back into position. Note: If switch is left in PROG FAIL-SAFE, the PC Tool software setting is active and can set the fail-safe position. It is recommended that the switch be set on the front of the actuator. This gives a simple visual as to what the fail-safe positon is set as. If the fail-safe is programmed using the PC Tool, and the switch is then moved off the PROG FAIL-SAFE position, the new position will override the PC Tool setting. The direction switch does not affect the fail-safe position switch. 7

Belimo worldwide: www.belimo.com BELIMO Americas USA Locations, Old Ridgebury Road, Danbury, CT 080 Tel. 800--908, Fax 800-8-88, marketing@us.belimo.com 09 Fortunado Loop, Sparks, NV 89 Tel. 800 987-90, Fax 800-987-887, marketing@us.belimo.com Canada Locations, / 7 Coopers Avenue, Mississauga, Ontario LZ E8 Tel. 8-80-7089, Fax 90-7-, marketing@us.belimo.com Latin America and The Carribean Customer Service, Tel. 0-79-89, Fax 0-79-99, marketing@us.belimo.com 8/0 Subject to change. Belimo Aircontrols (USA), Inc.