AWS-1025, 1075 & Torque Wrench Loaders Use with QC, MTM & Bench Stand Transducers

Similar documents
Electric Actuator Installation, Operation & Maintenance Manual

OWNERS MANUAL HF4263

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

FOR YOUR PERMANENT FILE

OWNERS MANUAL HF4261

OWNERS MANUAL HF

Performance Zone Assembly and Maintenance Manual

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

Quick Start Guide. CEM120 Center Balanced GoTo Equatorial Mount Models: #7300, #7301, #7302

2000SR. Installation Instructions May Donovan Enterprises 3353 S.E. Gran Park Way Stuart, Florida

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Dial Wrench Operating Instructions Rev 2.6 (4/10/17)

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Capture Torque Analyzer Operation Instructions Rev 1.0 (6/30/2014)

2015 & 2018 Fender Brace Installation Instructions

Phase Sequence Tester

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

AGRI-COVERTM SWITCH CONTROL INSTRUCTIONS

MOVE ON TO THE REAR BAR INSTALLATION

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9

Sport Sway Bar Kit (22431 ) Subaru Forester INSTALLATION OF HOTCHKIS FRONT SWAY BAR

V-Twin Forward Control Installation Instructions

DELUXE SMITH MACHINE MSS Model MSS Retain This Manual for Reference

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

JOHNSON/EVINRUDE 9.9 & 15HP SUZUKI For motors see below

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

HF4145 FOLDING MULTI-POSITION WORKOUT BENCH

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

Submersible Pond Pump with UV 800 Gallons Per Hour

MARCY PREMIER HOME GYM

SUBMERSIBLE MINI-PUMP

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment

Hi-Tech & Pro Magnum Roller Rocker Arms

FOR YOUR PERMANENT FILE

INSTALLATION INSTRUCTIONS

6 OFF ROAD LIGHT BAR

INSTRUCTION MANUAL NAIM SLIDE Warranty

INSTALLATION INSTRUCTIONS

Illumifalls Patio Pond

! Warning, refer to accompanying documents.

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Premium Pond Pump 330 Gallons Per Hour

22427 SWAY BAR SET 2002-UP SUBARU WRX WAGON

DISC BRAKE CALIPER TOOL SET

Harvil 4 Foot Air Hockey Table

Low-Water Auto Shutoff Pump with Light 300 Gallons Per Hour

Installation Instructions

XM-4424 INTERNATIONAL OLYMPIC BENCH with LEG & PREACHER

User Guide. Model Insulation Tester / Megohmmeter. Introduction

22421 SPORT SWAY BAR SET TOYOTA COROLLA

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Hand Held Pull Tester Instruction Manual Order No

1107 Tubular Upper A-Arms Camaro/Firebird

MARCY DIAMOND ELITE SMITH MACHINE

Installation Instructions Pet Barrier

Submersible Waterfall Pump 1200 Gallons Per Hour

PVI 60KW, PVI 82KW, PVI 95KW

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

Mechanical Filter Box Kit

CAMBELT TENSION GAUGE

NEED HELP? CONTACT US!

Operation Instructions

Assembly Instructions

INSTALLATION INSTRUCTIONS

EZ Carrier 3. Owner s Manual. Keep instructions for future reference

series USER MANUAL

Dodge Cummins 5.9L 24 Valve Edge Products EZ Module Installation Instructions & Manual

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

P/N# Performance Lowering Springs Installation Instructions

Premium Waterfall Pump 1200 Gallons Per Hour

24V Solar Charger. Instructions READ CAREFULLY Garrymore Ln Missoula, MT

MLS DEFENDER SOCCER TABLE ASSEMBLY INSTRUCTIONS

Operating and Service Manual

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

NEW GEN OWNER S MANUAL

Series 2100 Operating Instructions

Lint Slide Grid Moist Air Applicator

DELUXE OLYMPIC BENCH EVE Model EVE Retain This Manual for Reference OWNER'S MANUAL

NEW EQUIPMENT WARRANTY

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

Rear Suspension System C-10 Pickup Truck

SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

BMW E46 M3 SPORT SWAY BAR SET # 22826

1313 LOWER TRAILING ARMS CHEVROLET B-BODY

Sport Coil Springs Dodge Magnum, Chrysler 300C Dodge Challenger SRT Dodge Challenger R/T

TOOLS REQUIRED General mechanic tools

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

NF-Series Operation Instructions

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Transcription:

AWS-1025, 1075 & 11000 Torque Wrench Loaders Use with QC, MTM & Bench Stand Transducers USER'S GUIDE November, 2014 ADVANCED WITNESS SERIES, INC. 910 BERN COURT #100 SAN JOSE, CA 95112 PH: 408.453.5070 Fax: 408.453.5177 E-mail: Sales@awitness.com www.awitness.com

CONTENTS 1 CONTENTS CONTENTS... 1 INTRODUCTION... 2 Description... 2 System Specifications... 2 System Components... 3 ASSEMBLY INSTRUCTIONS... 4 Use Advice Notes... 5 DESCRIPTION OF FUNCTIONS... 6 Operating Mode... 6 Peak... 6 1st Peak... 6 Track... 6 Selecting a Transducer... 6 Engineering Units... 6 Full Scale... 6 Low Limit... 7 High Limit... 7 SERVICE AND WARRANTY... 8

Description of Functions 2 INTRODUCTION DESCRIPTION The AWS- 1025, 1075 and 11000 torque wrench loaders are designed to provide mechanical advantage to the testing of manual torque wrenches when used in conjunction with our torque transducers and torque analyzers. S pecifically the instruments that these loaders are designed to complement are the AWS - QC, QCM, AWS- 3000 Series, AWS - MTM S eries as well as any of our bench stand mounted transducers whether they are connected to our AWS - 4050 or our newer AWS - 8000 touch screen instruments. As you can see by the illustrations the transducer or the tester/analyzer is mounted onto an adapter plate that secures and centers the transducer in the loader. The torque wrench is inserted into the square drive of the transducer and the crosshead driven by a hand powered lead screw loads the torque wrench by advancing the torque wrench handle. This mechanism reduces the effort required by the operator to load the torque wrench and can reduce user error due to technician influence. The design and choice of materials used in manufacturing these loaders insure many years of trouble free use. The selection of precision ways and bearings insure proper fit without looseness or play between the parts contributing to better repeatability and less wear. These loaders are extremely durable yet lightweight, portable and easily provide the best value ratio available. SYSTEM SPECIFICATIONS Dimensions depending on model Power Requirements Operating Temperature Range Data Communications Width: 12", Height: 1 1 ", Depth: 20", Weight: 50 Lbs. NA NA NA Accuracy Depends on analyzer and transducer used. S tandard 0.5% of I ndicated Reading top 90% of Range. Optional 0.25% of I ndicated Reading top 90% of Range. Range 10% to 100% Optional 5% to 100% ( Expanded R ange) Display NA Units NA

Description of Functions 3 SYSTEM COMPONENTS Main carriage and transducer mounting plate Crosshead with lever handle Reaction Post Wrench support Extension bracket Bolts The torque wrench loaders are shipped with the pictured components. Main carriage with angle bracket for mounting transducer bench stand, cross slide for appling load to torque wrench handle, reaction post, torque wrench handle support, extension plate for small wrenches (top of picture to bottom left). I ncluded in the shipment are bolts for assembling components and attaching transducer bench stand. When unpacking, verify all components are included, if there are missing items please call our Customer Service department immediately, 408 453-5070. There are two different size bolts; 8 each 3/8-16 x ¾ socket head cap screw 2 each 3/8-16 x 2½ socket head cap screw 2 each ½ - 13 x 2½ socket head cap screw

Description of Functions 4 ASSEMBLY INSTRUCTIONS 1: Install cross slide onto main carriage as pictured. 2: I nstall reaction post, or extension bracket and reaction post, to cross slide platform. Place torque wrench handle support on reaction post. 3: Attach transducer to angle bracket on main carriage. When inserting torque wrench into transducer, it is very important to adjust the wrench handle support so the torque wrench handle is level. 4: When adjusting the cross slide it is important to position the reaction post at the respective end of the cross slide to enough travel to actuate a wrench.

Description of Functions 5 USE ADVICE NOTES There are several things to keep in mind when testing manual torque wrenches, failure to pay attention to these details will cause an increase in uncertainty in measurements, resulting in poor accuracy, repeatability and reproducibility. 1. Many torque wrenches, particularly click type wrenches are length dependent. This means that the test result will vary if the wrench load point (center of hand grip or reference indicator on wrench handle) changes during test or changes from test to test. Most, if not all manufacturers create a reference indicator to illustrate where the torque wrench should be gripped or positioned for loading. I t is imperative that users and calibration technicians are aware of this and follow the manufacturer s instructions in order to achieve the specified accuracy and repeatability of the wrench. 2. All test articles (torque wrenches) should be level and perpendicular to the transducer axis when testing. 3. Torque wrenches are comprised of mechanical mechanisms, i.e. springs, pins, levers, pivot points etcetera, these mechanical devices will produce more consistent results if the load applied to the torque wrench is deliberate and somewhat consistent. Loading or actuating a torque wrench fast will cause accuracy and repeatability errors. 4. I t is important to exercise ( actuate the wrench several times, usually three tim es) prior to comm encing with a calibration or verification test. 5. When using adapters and sockets it is very important to insure that the internal and external squares (fittings) have a common center and not offset in any direction. Otherwise if the squares/hexes are rotated they will cause measurement variation that could possibly exceed the accuracy statement of the wrench. 6. Users should be cautious when using extensions as these will increase the opportunity to lose perpendicularity on the test article which will effect measurements and could cause significant variation.

Description of Functions 6 DESCRIPTION OF FUNCTIONS The following is a description of the standard features of the AWS product line. OPERATING MODE Current operating mode (Peak, 1st Peak or Track) will show on the display. Press the key to toggle between them. Peak Displays and retains the maximum peak torque experienced by the wrench. The Peak Mode is used for all power tools and most dial wrenches. 1st Peak Detects the first peak of torque experienced by the wrench, which is the initial peak torque when the mechanism in the click wrench actuates. First Peak is used primarily for Click torque wrenches and torque limiting or cam- over type screwdrivers. Track Displays torque as it is being applied to the transducer. Track mode is used primarily for verifying calibration of the transducer or analyzer. It is also used to check condition of the transducer and zero with no strain on the transducer SELECTING A TRANSDUCER IMPORTANT NOTE: On power- up, the transducer that is selected will be active and ready to use. When changing transducers, you MUST Zero the unit. Do this by pressing the On/Zero. The shaft capacity can be verified by going to the Information screen in the S ystems Menu (2-4). Full Scale capacity screen is shown. Press the ENT button twice to return to the run mode. ENGINEERING UNITS Current engineering units are displayed. Press the key to cycle through the eight possible choices: Kgf m, KgfCm, gfcm, cnm, Nm, FT LB, I N LB, I N OZ. FULL SCALE This screen shows the Full- Scale value of the transducer. This is not a field adjustable value.

Description of Functions 7 LOW LIMIT Use the low limit setting as a means of visually flagging the operator when a reading fails to reach a desired minimum value. A small down arrow will appear on the screen if a peak is captured below the limit setting. The limit is adjusted by using the navigation buttons to set the first four digits to the desired value. The fifth digit is used to select the decimal point position. The up and down buttons under the S oft button Change will change the value from 0-9. Pressing the soft DI G will scroll through the digit positions. When the correct value is entered, pressing the ENT button will return you to the menu system. Once all the digits have been set, press the MEM key to accept the value and return to Program Function mode. The next time a reading is taken, "LO" will appear on the display if the captured value is less than the low limit HIGH LIMIT Use the high limit setting as a means of visually flagging the operator when a reading falls over a desired m aximum value. High limits are set in the identical way as low limits. Please refer to the Low Limit section for details. NOTE ON LIMITS: The green LED on the front of the display will flash when a peak is captured that falls within the limit setting.

Service and Warranty 8 SERVICE AND WARRANTY SERVICE To ensure the best possible support for our customers, Advanced Witness S eries maintains a complete calibration and repair facility for all its products. We keep in stock most replacement parts for torque testers, transducers, and our line of digital wrenches. When you buy a product from us, the only place you need to go for parts and service is...us! For service, call (408) 453-5070, Monday through Friday, between the hours of 9: 00am and 5: 00pm Pacific Coast Time. THE WARRANTY CARD In order to ensure protection of the warranty as described below, you MUS T fill in the appropriate information on the warranty card that came with your unit and return it to Advanced Witness S eries, I nc. within 30 days of receipt of item. We wish to call your attention to the fact that this system and various components need calibration and certification on a periodic basis. By returning the card to us, you will receive timely notification as to when this re- calibration and re- certification is due. STATEMENT OF LIMITED WARRANTY ADVANCED WITNESS SERIES, INC. products are warranted free of defects in material and workmanship for a period of one (1) year from date of shipment. This warranty does not include failures due to application of torque to transducers or loaders beyond the stated capacity, operating system with a damaged transducer cord, nor any other misuse, abuse, or tampering. When used with impact type wrenches, the warranty is limited to the electronic digital display units only. This warranty does not cover calibrations. All freight charges are the responsibility of the company or individual returning the item(s) for repair. Freight collect shipments will not be accepted. Any modification to any of this equipment, without the express written approval of ADVANCED WI TNES S S ER I ES, I NC., will void this warranty. ADVANCED WI TNES S S ER I ES disclaims any and all liability, obligation or responsibility for the modified product; and any claims, demands or causes of action for damage or for personal injuries resulting from the modification and/or use of such a modified ADVANCED WI TNES S S ERI ES product. ADVANCED WITNESS SERIES, INC.'S OBLIGATION WITH RESPECT TO ITS PRODUCTS S HALL BE LI MI TED TO REPAI R OR REPLACEMENT, AND I N NO EVENT, SHALL ADVANCED WITNES SERIES, INC. BE LIABLE FOR ANY LOS S OR DAMAGE, CONSEQUENTIAL OR SPECIAL, OF WHATEVER KIND OR NATURE OR ANY OTHER EXPENS E WHI CH MAY ARI S E I N CONNECTI ON WI TH OR AS A RESULT OF SUCH PRODUCTS OR THE USE OR INFORMATION THEREOF IN A JOB. THI S WARRANTY I S EXPRES S LY MADE I N LI EU OF ALL OTHER WARRANTI ES OR MERCHANTABI LI TY AND FI TNES S FOR A PARTI CULAR PURPOS E. NO EXPRES S WARRANTI ES AND NO I MPLI ED WARRANTI ES WHETHER OF MERCHANTABI LI TY OR FI TNES S FOR A PARTI CULAR PURPOS E OR OTHERWISE OTHER THAN THOSE EXPRESSLY SET FORTH ABOVE SHALL APPLY TO ADVANCED WITNESS SERIES.