Similar documents
TECHNICAL DATA HYDRAULIC UNIT

Oil-hydraulic operator for swinging gates

INSPECTIONS AND MAINTENANCE

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

INSTALLATION MANUAL GB

CHECKING AND MAINTENANCE:

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

GB INSTALLATION MANUAL

GB Instructions Manual

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

BAYT 980. Oil-hydraulic Road Traffic Barrier. BAYT 980 painted version BAYT 980 stainless steel version inox

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres

I - Libretto di istruzioni GB - Instructions manual F - Notices de montage

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Typical Installation Schematic

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Automation Swing Gate Opener

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Instruction Manual for the. E-SL 450 Series

Automatic concealed bollards 275 H600 and 275 H800 with pit

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

Installation Manual. Swing Gate System. Leading the way...

SWING GATE OPENERS 24V DC GEAR MOTOR

FITTING AND CONNECTION INSTRUCTIONS

Sliding Gate Operator User's Manual

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

CHECKLIST & COMPONENTS

TEL: G&C Electronics CC E. T.

SWING GATE OPENERS 24V DC GEAR MOTOR

a p prove d ELECTROMECHANICAL SLIDING GATE OPENER

INSTALLATION MANUAL (cod )

AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

BARRY BARRIER GATE AUTOMATION

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Automatic concealed bollards 275 H600 and 275 H800 Control station

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Sliding Gate Operator User's Manual

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

Installation Guide Rollerdor RD55 Econ Roller Garage Door

FORCE SPD 800/1500/2000

ARACHNE 230V 24V- 12V

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

TITANO 400V SLIDING GATE OPENER

FEATURES AND SPECIFICATIONS

OPERATIONS MANUAL LEVER CHAIN HOIST

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

E R A I GATE AUTOMATION DIVISION

Operating Instructions Type MPT 53

SKC400U SLIDING GATE OPENER OWNER S MANUAL

INSTRUCTIONS FOR INSTALLATION

PROFESSIONAL 270 o PIR MOTION DETECTOR

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

BISON 20 OM BISON 25 OTI

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

Hunter Automatics HA-8. Installation Manual

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

EC DECLARATION OF CONFORMITY

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

LI-2B Installation Manual

SLIDE NEW CONTROL BOARD

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1

Gate & Door Controller with LCD and Intelligent Technology

IMPORTANT NOTICE FOR THE INSTALLER

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

SWING GATE OPENER SW300 SERIES

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

AUTOMATIC CONTROL ROLLING DOOR OPENER

Model 2300JL Installation Guide

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

Model 2300DL Installation Guide

The 750 Swing Gate Operator and 450 MPS Control Panel: Installation Manual

Automation systems for swing gates hydraulic

Installation and Maintenance Manual

INSTRUCTION MANUAL MAGNA RAIL

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

The House of Gate Automation

Adjustable Pneumatic Time Delay Switch

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Operating Instructions Pedestrian Turnstile Type MPT 33

LINCE 300/400/600. User s and Intaller s manual

Installation Guide Rollerdor RD55 Econ Roller Garage Door

YG101 SWING GATE OPENER OWNER S MANUAL

Porte 150 Users Manual Swing Gate Opener 24V DC

Transcription:

GB INSTALLATION MANUAL

DRIVE 700 INSTRUCTIONS TO INSTALL THE SYSTEM FOR A PERFECT APPLICATION AND PERFORMANCE OF DRIVE 700 SYSTEM IT IS RECOMMENDED TO KEEP TO THE INSTRUCTIONS AND THE DIAGRAMS IN THIS MANUAL. IMPORTANT:THE INSTALLATION IS TO BE CARRIED OUT BY QUALIFIED TECHNICAL PEOPLE IN COMPLIANCE WITH EN 12453 - EN 12445 SAFETY NORMS AND 98/37/EC MACHINE DIRECTIVE. GENERAL FEATURES DRIVE 700 is an electro-hydraulic mechanism, part of which to be fitted under the ground while the motor pump unit is external and separately fitted, to operate single or double swinging gates. Recommended gate weight is 700 kg per gate. The two basic versions allow rotation angles of 110 and 175 degrees respectively. Both versions are also available in different options, as follows: non locking (an electric lock is recommended to be fitted to the gate/s); locking where the gates are hydraulicaly locked in any required position by DRIVE 700 in either directions of movement ie. opening or closing; Braking on Opening and Closing, non Braking; and eventually they can be fitted with a flow regulator to control and keep constant the speed of the gates during the rotation movements. IMPORTANT: All the above models of DRIVE 700 imply that the gates are fitted with an electric lock in case they are wider than 2 meters. PRELIMINARY INSPECTION OF THE GATE CONDITION Before going on fitting DRIVE 700 it is recommended to carry out the following: - Make sure that the gate structure is adequate to be electrically operated: check that all the metallic parts, if any, are all right and do not show deformation, strengthen possible weak points and inspect the hinges to be in perfect good condition without any friction points etc. - No obstacle is to interfere with the gate travel: make sure that the ground in the area of the gate movement is levelled. - The gates are to be well built, mounted straight and aligned. - IMPORTANT: Gate stops are to be provided and firmly fixed in the required open and closed gate positions. Verify solidity before operating the system. GATE POST WALL SWINGING GATE TO OPERATE MOTOR PUMP UNIT FIXING MOTOR PUMP FRONT COVER F-RING SQUARE SECTION HOLE GATE STOP IN CLOSED GATE POSITION LATCH TO HOLD GATE IN CLOSED POSITION ENCLOSURE LID. NERROW SECTION OIL-HYDRAULIC JACK ENCLOSURE GATE STOP IN OPEN GATE POSITION PIC. 1 ENCLOSURE LID. LARGE SECTION GUIDE BASE FIXING ANGLES 2

PREPARING THE GATE The gate to be operated must be prepared to take the DRIVE 700 mechanism. For a perfect performance of the system, it is most important that the gate is hanged only by the top hinge whereas the mechanism rotation shaft is to provide a seat for the gate and replaces the lower hinge (Pic. 2). 65 mm IMPORTANT: Ideally the gate hinge centre line should be approximately 65 mm away from the gate post surface line (Pic.2) With existing gates, it is sufficiente that the DRIVE 700 jack, ie. the underground mechanism, is positioned closed to the gate post in axis with the centre line of the gate top hinge. NOTE: With existing gates, remove the lower hing and fit the shaft ring in compliance with the indications provided on page 4, Putting the jacks in phase. PIC. 2 FITTING THE JACK - Dig a hole in the ground at the gate foot, close to the gate post, as indicated in Pic. 3. IMPORTANT: The dimensions indicated are in consideration that the hole has to be large enough to accomodate the jack, to fit the two halves of the enclosure around it, and the piping between the jack and the external motor pump unit (read the section installation of the motor pump on page 5). - Set the fixing base plate with concrete at the bottom of the hole ie. 130 mm deep from ground level. Make sure that it is perfectly straight and levelled as it is to take the hydraulic jack on to it and ensure that the shaft center and the top hinge center are aligned on the same axis. - Let the concrete set well around the fixing base plate so this can provide a firm setting to further operations (Pic.3). GATE 65 mm SPIRIT LEVEL TOP HINGE GATE POST SPIRIT LEVEL GATE POST 550 mm 280 mm 220 mm GATE 65 mm 280 mm GATE POST ESCAVATE UNDER THE GATE FOOT CLOSE TO THE GATE POST 220 mm 130 mm CONCRETE SETTING 20 mm PIC. 3 3

- Lay the jack, which is fitted with a guide base plate, on to the ground fixing base plate. - Make sure that the jack, once fitted on to the base plate fixed to the ground, has the shaft straight with the top hinge center line: a plumb line is recommended in this case to ensure that the jack shaft is in true vertical position (Pic.4). - Weld the four angles, provided with the equipment, on to the ground fixing base plate to match the position of the corners of the jack base plate, to keep the jack in the correct position (Pic.5). NOTE: Before fixing the corners, operate the gate manually open and closed to assess smoothness and alignment. JACK PIC. 4 ANGLES ROTATION SHAFT IN AXIS WITH THE HINGE CENTER LINE PIC. 5 GUIDE BASE ANGLES WELDED ON TO FIXING BASE PUTTING THE JACKS IN PHASE The oil-hydraulic jack is to be fitted to the gate by means of a specially designed ferrule (f-ring) having a square center hole. A reinforcement plate is generally recommeded to fix the F-ring to the gate foot. Before this operation, it is needed to put the jacks in phase: that is to say to set the jack shaft in the required position to achieve correct gate operation by rotating the shaft to the limit of the permitted stroke in closed gate position; this is to be done before welding the angles on to the fixing base plate and before piping the jack to the motor pump unit. PLEASE NOTE: It is extremely important that the jack shafts are in the correct phase to ensure that the gates are properly and securely driven to close position and the setting is maintained for long time. - By means of a wrench rotate the jack shaft until you can feel that the limit of the permitted stroke in closed gate position is reached: in this position it can be noted that one of the flattened sides of the shaft is now positioned 5 degrees beyond the closed gate line (no need to rotate hard, as the jack is not piped yet and no fluid is inside it yet). JACK FIXED TO THE GATE STOP IN CLOSED POSITION JACK FIXED TO THE 5 5 PIC. 6 4 CLOSED GATE CLOSED GATE

- Make sure that the hydraulic jack is perfectly levelled before fixing the F-ring by tightening or loosening the adjusting screws in the jack guide base (Pic.7). A spirit level can be used to assess levelling. - Fit the F-ring to the jack shaft and indelibly mark it so that the required shaft fitting position can be noted on it (this is quite simple as both the shaft and the F-ring have four flattened faces). - Remove the F-ring from the shaft (Pic.8) - Rotate the shaft back by a wrench so that the nearest flattened face is aligned with the gate in closed position. - Fit the F-ring back to the shaft in the same position as marked before. - Before definitely fixing the parts, spot weld the F-ring to the plate and the plate to the gate and carry out some maual open and close operations of the gate. SPIRIT LEVEL ADJUSTING SCREWS SPIRIT LEVEL PIC. 7 ROTATION SHAFT DRIVE 700 F-RING ROTATE TO THE LIMIT OF THE PERMITTED CLOSE END STROKE F-RING ROTATE THE SHAFT UNTIL THE FLATTENED SIDE IS STRAIGHT WITH THE GATE IN CLOSED POSITION STRENGTHENING 5 CLOSED GATE AXIS CLOSED GATE AXIS PIC. 8 - Weld the F-ring to the gate foot and interpose a strengthening plate between them, making sure that the parts are vertically straight with the gate top hinge center line and that the fixing geometry has been strictly respected as indicated before. Perfect alignment of the DRIVE 700 shaft with the gate hinge is essential to the correct operation of the gates (Pic.9). FITTING THE MOTOR PUMP UNIT The hydraulic motor pump unit is to be fitted at a suitable distance from the jack so as piping can be as easy as possible in respect of the site requirements. It is also to be considered that an easy access to the internal parts of the hydraulic motor pump unit is recommended during the fitting operations and to be able to override the system for manual operations in events like an emergency or power failure. PLEASE NOTE: for gates wider than 2 meters it is always recommended to use the non locking version of the motor pump unit and fit the gates with an electric lock - Before starting the piping operations, bring the enclosure apart. Drill a hole in the lateral component, where piping is required, the size of the hole must be adequate to take a tube through it, into which the pipes from the motor pump unit to the jack are to be laid (Pic.10 and 12). ENCLOSURE WELD THE F-RING TO THE STRENGTHENING AND THIS TO THE GATE TUBE TO HOUSE THE PIPES PIC. 9 LATERAL ENCLOSURE COMPONENT PIC. 10 5

- Fix the electro-hydraulic motor pump unit by means of expanding bolts (not included). It is to be fixed close to the gate to operate in the most suitable position considering all the fitting, setting and testing operations involved. - Excavate between the jack and the motor pump (Pic.12) and lay a tube to house the pipes: copper pipes are supplied on request in one length to be bent on site to meet the application requirements. FIXING BOLTS HYDRAULIC MOTOR PUMP UNIT HYDRAULIC JACK PIC. 11 HYDRAULIC MOTOR PUMP UNIT KEY HYDRAULIC JACK HYDRAULIC MOTOR PUMP UNIT PIPES FRONT COVER SPIGOT GRAVEL LAYER TO PROVIDE A SOAKAWAY OIL-HYDRAULIC JACK ENCLOSURE PIPE CONDUIT NUT 3 mm ELBOW FITTING PIC. 12 IMPORTANT: Avoid sharp bending in the pipes between the motor pump unit and the jack; make sure that all nuts in the jack and motor pump are well tightened. - Assemble the enclosure around the jack and fix it with concrete. Fill in the whole escavation from the hole where the jack is located to the motor pump unit where the pipes are laid. FILLING THE MOTOR PUMP WITH POWER OIL - Unlock the motor pump front cover by the provided key and remove it. Incorporated in the motor pump unit is a funnel. Pull it outwards (2 cm approx.) and turn it up (Pic. 13). - The power oil, supplied with the equipment in a 3 l container, is to be poured up to the sight glass. POWER SUPPLY CABLE FUNNEL OIL LEVEL SIGHT GLASS 6 PIC. 13

FITTING THE ELECTRIC LOCK, THE MECHANICAL LATCHING BOLT AND THE GATE STOPS It is recommended to fit the gates with an electric lock either vertically or horizontally positioned (70 cm high from ground level in the second case) in order to better hold the gates in the closed position. The gate that is fitted with the electric lock is to be 5 degrees out of phase against the other one and has to reach the stop closed position a bit later than the gate that is fitted with the catching plate. In the case where the gate lock is horizontally fitted, it is also needed to fit a latching bolt to the gate that first reaches the gate stop. The bolt is latched into the gate stop by the other ie. the delayed gate on approaching the gate stop (Pic.14). IMPORTANT: Provide the installation with gate stops in the open gate position to be fixed 5 before the jack reaches the very end of the permitted stroke. DELAYED GATE HORIZONTAL ELECTRIC LOCK THIS GATE CLOSES FIRST HORIZONTAL ELECTRIC LOCK CATCHING IIN CLOSED POSITION 70 cm LATCHING BOLT 90 GATE STOP OPEN POSITION THIS GATE CLOSES FIRST GATE STOP CLOSED POSITION 95 VERTICAL ELECTRIC LOCK 70 cm FIT THE HEAD OF THE GATE THAT CLOSES FIRST WITH A LATCHING BOLT TO BE DRIVEN INTO THE CLOSED POSITION GATE STOP WHERE A HOLE HAS BEEN PROVIDED FIRST PIC. 14 ELECTRICAL CONNECTIONS TO ELPRO 13 CEI CONTROL PANEL Before carrying out any electrical connections read the enclosed electrical wiring diagrams (Pic.15). IMPORTANT: All the equipment must be properly earthed (Pic.15). - The mains, electric motor and flashing lamp wires must have a 1.5 mm 2 square section for a max. distance of 50 m in case that a longer distance is required, section must be 2 mm 2. - 1 mm 2 square section wires can be used for the accessories such as the photocells, keyswitch etc. 1) MIRI 4 FLASHING LAMP 2) ELPRO 13 CEI CONTROL PANEL 3) O.O3 A MAGNETIC-THERMAL CIRCUIT BREAKER 4) JUNCTION BOX 5) DRIVE 700 MOTOR PUMP UNIT 6) DRIVE 700 JACK 7) POLO 44 PHOTOCELL RECEIVER 8) ELECTRIC LOCK 9) POST-MOUNTED POLO 44 PHOTOCELL PROJECTOR 10)POST-MOUNTED POLO 44 PHOTOCELL RECEIVER 11)POLO 44 PHOTOCELL PROJECTOR 12) JUBI 433 EXTERNAL RADIO RECEIVER 13) BIRIO A 8 AERIAL 14) PRIT 19 KEYSWITCH 14 13 15) JUBI 433 TRANSMITTER 12 3 2 1 RG58 cable n 4x1 n 2x1 n 4x1 n 2x1.5 n 4x1.5 230 V 50 Hz n 4x1 n 4x1.5 n 4x1.5 4 5 6 7 95 n 2x1 8 GATE STOP IN CLOSED GATE POSITION GATE STOP IN OPEN GATE POSITION AT 95 90 6 GATE STOP IN OPEN GATE POSITION AT 90 11 5 10 n 4x1 9 PIC. 15 n 2x1 15 7

- Carry out all the electrical connections to the Elpro 13 CEI control panel - First running test: set the Motor Run Time 09 to a value 4-5 seconds higher than the time required by the gates to reach the gate stop; set the Dwell Time 08 (automatic mode) and Gate Delay Time in Closing Cycle 07 (in case of double swinging gates) as required, pic. 16: - Automatic Mode: Dip-switch B No. 3 set to ON. Once an open pulse is given (to terminals 4 and 8 in Elpro 13 CEI main terminal board, pic.16), the gates are driven to open, stopped for a time as set by the Dwell Time 08 and then automatically re-cycled to close. - Semi-automatic Mode: Dip-switch B No. 3 set to OFF. Once an open pulse is given, the gates are automatically operated only to open; a second pulse (to terminals 5 and 8 in the Elpro 13 CEI main terminal board, pic.16) is needed to close the gates. - Radio Contact: terminals 7 and 8 in the Elpro 13 CEI main terminal board, pic.16. Any pulse from a keyswitch, remote control or push button reverses the gate travel (it is recommended to carefully read the instructions provided in the control box). FOR SWING GATES SINGLE-PHASE B 26 27 28 TERMINALS FOR THE CONNECTION OF THE PUSH BUTTONS PULIN 3 ON Should more pairs of photocells be required than the recommended quantity, fit an auxiliary transformer outside the control box. DIP-SWITCH 3 4 RADIO CONTROL PLUG-IN CARD SUPPORT ON 1 CHANNEL 24 V OUTPUT PEDESTRIAN MODE ONE PULSE OPENS ONE GATE LEAF ONLY MICROPROCESSOR FADINI 1 2 3 4 5 6 7 8 1 2 3 4 5 6 OFF -PHOTOCELLS 2nd PAIR- INSIDE PHOTOCELLS N.C. contact. If obstructed, they prevent the gates from opening, reverse gate direction during close cycle. ON TO 0 THE DELAY IS OUT OF SERVICE 1 2 3 4 5 6 7 8 9 10 11 12 13 N.C. CONTACT. PHOTOCELLS COMMON OPEN SWITCH N.O. CONTACT CLOSE SWITCH N.O. CONTACT STOP SWITCH N.C. CONTACT RADIO CONTACT N.O. 7 8 COMMON 7 8 9 VOLTAGE OUTPUT ELECTRIC LOCK SUPPLY 0 24 V - 3 W max. INDICATOR Max. permitted load: 24 Vac OUTPUT 2 pairs photocells 1 radio receiver LEAF DELAY TIMER + CLOSE + DWELL TIME MOTOR RUN + TIME OPEN & CLOSE COMMON CAPACITORS 12,5 µf 12,5 µf 16 17 18 19 20 21 22 23 24 25 M1 COMMON F5 M2 ELECTRIC MOTORS SINGLE-PHASE 1 FUSE: 24 V OUTPUT TERMINALS 12-13 230 V - 25 W max FLASHING LAMP CUT OFF SWITCH BY COVER KNOB 230 V SINGLE-PHASE SUPPLY VOLTAGE F3 F4 630 ma FUSE F2 5 FUSE F1 630 ma 5 FUSE FUSE FLASHING LAMP N. W.: for special applications, ie. to switch on lights - CCTV etc, SOLID STATE RELAYS are recommended to be used only. Standard relays would affect the micro-processor. N.W.: THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH FADINI ACCESSORIES. NO GUARANTEE FOR ACCESSORIES OF OTHER MAKE OR SPECIAL APPLICATIONS. PULSE TWICE CONSECUTIVELY TO OPEN BOTH GATE LEAFS ALL OPERATIONS OPEN, CLOSE & REVERSE RADIO CONTACT Drwg. 2014 PIC. 16 8

FEATURES OF THE ELECTRONIC PROGRAMMER FOR SWINGING GATES All the electrical connections are to be made as per the following instructions and diagrams. Supply the terminals 24-25 with 230V - 50 Hz single phase voltage. The red LED switches on and stays on as long as the board is properly supplied. Through the timer No. 9 you can control the running time of the motor in both cycles, OPEN and CLOSE. Set it so that the running time of the motor is longer than the actual travel of the gate: set the timer No. 8 -DWELL- ie. the interval between open and re-closing, so that you can meet the required interval of time. - With the electric motor connected to terminals 19-20 - 21: the delay is operative in the open cycle, with a factory pre-set time. - With the electric motor connected to terminals 16-17 - 18: the delay is operative in close cycle and can be adjusted through the timer No. 7 on to less or more. LOGIC OF THE ELECTRONIC PROGRAMMER: When a pulse is given, the flashing light switches on. After three seconds the motors start. During the interval before re-closing, the light stays on. When the gates are fully re-closed, the light keeps on flashing for three more seconds and then switches off automatically. The 3 second interval (pre-flashing) which precedes the actual start of the motors can be eliminated by means of the DIP-SWITCH B No.4. LED No. 1: It switches on when voltage is supplied. LED No. 2: PHOTOCELLS. Normally on. It switches off when the photocells are obstructed. LED No. 3: OPEN. It switches on when the respective switch is activated. LED No. 4: CLOSE. It switches on when the respective switch is activated. LED No. 5: STOP. Normally on. It switches off when the respective switch is activated. LED No. 6: RADIO. It switches on whenever a pulse is given, either from remote control, keyswitch or push buttons. DIP-SWITCH B SETTING IN ELPRO 13 CEI N 1 OFF = PHOTOCELLS. NO STOP IN OPEN CYCLE. REVERSE/CLOSE N 2 OFF = REMOTE CONTROL. REVERSE N 3 OFF = NO AUTOMATIC RECLOSING N 4 OFF = NO PRE-FLASHING N 5 OFF = REMOTE CONTROL. NO STOP AND HOLD AS LONG AS BUTTON DOWN. IT OPENS STRAIGHT AWAY N 6 OFF = BOTH LEAFS ARE OPERATED N 7 OFF = STROKE REVERSING PULSE OUT OF SERVICE N 8 OFF = LEAF DELAY OPEN CYCLE. ONE STARTS BEFORE THE OTHER N 1 ON = STOP DURING OPEN CYCLE N 2 ON = NO REVERSE DURING OPEN CYCLE N 3 ON = AUTOMATIC RECLOSING N 4 ON = PRE-FLASHING N 5 ON = STOP AND HOLD AS LONG AS THE BUTTON IS KEPT DOWN N 6 ON = PEDESTRIAN. ONE LEAF ONLY GATES IN CLOSED POSITION N 7 ON = S. R. P. IN SERVICE GATES IN CLOSED POSITION N 8 ON = NO LEAF DELAY BOTH MOTORS START TOGETHER LAMP ON = GATE OPEN LAMP FLASHES SLOWLY = GATE OPENING LAMP FLASHES FAST = GATE CLOSING LAMP OFF = GATE CLOSED 1) It is advisable not to expose the control box directly to weather conditions; if mounted outside, a suitable enclosure is recommended to protect it from sunshine and rain. 2) Bridge terminals 1-2 if you do not require any photocells. 3) Should two sets of photocells be required, these are to be series connected to terminals 1-2, contact normally closed. 4) Bridge terminals 6-8 if you do not require any keyswitch or push buttons. 5) Fit the mains to the control box with a high sensitivity, differential, magnetic-thermal switch, 0.03 Amps. 6) OPERATING MODE WITH TWO PAIRS OF PHOTOCELLS, INDEPENDENT FROM EACH OTHER Dip-switch No. 1 set to OFF, connect the pair of photocells that are inside the property to the terminals marked 2nd pair. The second pair always stops the gate in open cycle in case of an obstacle. During close cycle the second pair reverses the gate direction. 7) NOTE WELL FAULT FINDING: - Check supply voltage with a tester: it must be 230 V, single-phase. - Check the high voltage fuses. - Check the low voltage fuses. - Check if the photocell contacts are normally closed. - Check voltage from the control box to the electric motor(s): power might have dropped. - The section of the electric cables to the motor(s) must not be less than 1.5 mm 2. - Connect the other pair to the terminals 1-2 This pair performs in the standard pre-set mode, ie: no stop during open cycle, REVERSING GATE DIRECTION DURING CLOSE CYCLE. Terminals to stay linked out should the second pair of photocells not be used, and set the desired operating mode through Dip-switch No. 1. * 24 V ~ output. Terminals 12-13. It can supply power for 2 pairs of photocells plus 1 radio receiver. Terminal 11 provides a power output for a lamp. 24 V - 3 Wmax. Flashing lamp output. Terminals 22-23. Maximun available power 25 Wmax. 9

FEATURES AND TECHNICAL SPECIFICATIONS Elpro 13 CEI represents the latest state of the art technology for control panels. It is extremely versatile and can meet the most various requirements. It is fitted with the Cut Off Switch by cover knob. It has the same functions as Elpro 9 and incorporates additional advantages as follows: Stroke Reversing Pulse, Pedestrian Operating Mode (where one leaf only can be operated allowing people to walk in/out), STOP and HOLD function by keeping the remote control button pressed down. Further improvements can be noted in the Elpro 13 CEI : - Addition of a 1 Amp. fuse to the 24 V circuit as a protection for the accessories (remote control - photocells -etc.) which are connected to the terminals 12-13 and for the panei itself in that it can prevent short circuit during installation. - The pulse to the electric lock is increased to 2 seconds. Releasing is so much easier as the electric lock is released with an anticipation of 100 msec. before the gate starts moving. - A 24 V - 3 W lamp indicates gate operations (Gate CLOSED = Lamp OFF - Gate in OPEN cycle = Lamp flashes slowly - Gate OPEN = Lamp stays ON without flashing - Gate in CLOSED cycle = Lamp flashes fast). - It provides a better switching intelligence design to enhance the reliability of the relays. - The Motor Run Time is independent from the Leaf Delay Time in close cycle (the delay time is automatically added to the duration of the opening time). - The 8 Dip-switches can be arranged into any of the possible patterns to achieve the required operating modes without any risk of interference with one another. STROKE REVERSING PULSE and S.1A.P. Set Dip-switch No.7 to ON. The Stroke Reversing Pulse (S.R.P.) is activated only with the gate in the closed position. The pulse operates the gate in the CLOSED direction first and then immediately reverses into OPEN (This will help the gate lock to release). All the other operations will be performed in the standard way. No danger comes from the Stroke Reversing Pulse. This function remains in service with the panel set to Pedestrian Mode. Set Dip-switch No.6 to ON for Pedestrian Mode (S.1A.P.), terminals 3-4. Only one leaf is operated when the OPEN button is pressed down. Automatic reclosing. If the OPEN button is pressed twice in a row, both leafs are opened. The S.1A.P. function is activated only when the gate is in the fully CLOSED position. The remote control always operates both gates, terminals 7-8. FIRST RUNNING TEST Once satisfied that the electrical connections have been completed as described, test the system to make sure that it works as required: it is essential that on pulsing to the electric motors of the oilhydraulic motor pump units both gates are to be operated in the same direction. Should they fail to perform in a synchronized way, swap the electrical motor connections, ie. live 1 and 2 for both gates to open (Pic.17). PLEASE NOTE: should the electric motors fail to start because of electric power shortage, fit a 12.5 µf capacitor between the two live wires (Pic. 17) 12,5 µf VOLTAGE SUPPLY CABLE COMMON LIVE 1 LIVE 2 ADDITIONAL CAPACITOR PIC. 17 PRESSURE ADJUSTMENT Remove the oil-hydraulic motor pump unit front cover; the two pressure valve adjustment screws can be noted in the base of the unit, one is red in colour and controls pressure in the close cycle (check the electric motor connections), the other one is green for the open cycle (Pic.18). A screwdriver is needed to adjust the valve pressure: the tighter the screw is driven the higher the pressure is; by turning it the other way round, pressure is decreased. ADJUSTING VALVE SCREWS CLOCKWISE = MORE POWER ANTI-CLOCKWISE = LESS POWER PIC. 18 10

OVERRIDING AND MANUAL OPERATION In cases when power fails and during some phases of installation, it is needed to override the system and operate the gates by hand, DRIVE 700 operators, locking version, still fitted to the gates: remove the front cover of the oil-hydraulic motor pump unit and unscrew the release knob by one or max. two turns. The knob is fitted in the base of the unit (a key is supplied with the equipment to unlock the front cover (Pic.19). IMPORTANT: If DRIVE 700 non locking version has been fitted, and manual operation is required, unlock the gate electric lock by means of its key, and open the gate. No need to do any operation with the DRIVE 700 system. RELEASE BY 1 OR 2 TURNS TO OVERRIDE DRIVE 700 LOCKING FOR MANUAL OPERATIONS RELEASE KNOB PIC. 19 BRAKE ADJUSTMENT ie. DAMPENING Should a DRIVE 700 system braking in Open and Close cycles have been installed, it is necessary to adjust the brake ie. the dampening device to slow down speed over the last 40 cm of the gate travel, before the gates reach the gate stop (please remember, it is essential that the installation is fitted with gate stops in the open and closed gate positions). Pic 20: - Remove the two parts of the enclosure lid - The screw that controls the dampening device is fitted in the end cap of the oil-hydraulic jack: tighten the screw to increase the slowing down effect, loosen it to increase speed on approaching end of travel. BRAKE ADJUSTMENT SCREW PIC. 20 AIR BLEEDING This operation is needed after completing and testing the installation. A screw is fitted in the jack end cap for air bleeding. Loosen the screw for a little while. At the beginning some air and oil can be noted to come out. When only oil comes out, firmly tighten the screw. Avoid overtightening (Pic. 21). BRAKE ADJUSTMENT SCREW AIR BLEED PIC. 21 11

110 DRIVE 700 OVERALL DIMENSIONS 40 10 155 344 324 140 460 9-2004 356 150 50 38 10 136 65 40 150 156 230 165 156 150 12 230 230 160 460 116 TECHNICAL SPECIFICATIONS ELECTRIC MOTOR Power Yield...0.24KW (0.33HP) Supply voltage...230v Frequency...50Hz Absorbed current...2a Absorbed power...400 W Capacitor...12.5 µf Motor rotation speed...1. 350 r.p.m. Intermittent service... S3 OIL-HYDRAULIC MOTOR/PUMP UNIT Pump flow rate P3...0.85 l/1 min. Average working pressure...1mpa (10bars) Max. pump pressure...3mpa (30bars) Oil type...oil FADINI A 15 BY AGIP Tank capacity...0.95 dm 3 Static weight...8 Kg Working temperature...-20 C - +80 C Protection standards...ip 673 OIL-HYDRAULIC JACK Rotation angle...110 /175 Rotation time 110...23 s Rotation time 175...28 s Max. rated torque...235nm Piston diametre...75mm Piston stroke...52mm Working temperature...-20 C - +80 C Oil volume...0,25dm 3 Static gate weight...700kg PERFORMANCE Duty cycle:...23 s Opening - 30 s Dwell - 23 s Closing Time of one complete cycle:...76s No. of complete cycles Opening-Stop-Closing...47/Hour 137. 000 cycles per year, 8 hours service per day CHECKING AND MAINTENANCE: To achieve an optimum performance and longer life of the equipment and in observance of the safety regulations, it is recommended that inspections and proper maintenance are made by qualified technicians to the whole installation ie, both the mechanical and electronic parts, as well as wiring: - Mechanical parts: maintenance every 6 months approx. - Eletronic apparatus and safety equipment: maintenance every month. The growth of MECCANICA FADINI has always been based on the development of guaranteed products thanks to our TOTAL QUALITY CONTROL system which ensures constant quality standards, updated knowledge of the European Standards and compliance with their requirements, in view of an ever increasing process of improvement. EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 98/37/EC DECLARATION OF CONFORMITY GENERAL WARNINGS EN 12453, EN 12445 STANDARDS CEI EN 60204-1 STANDARDS WARRANTY CERTIFICATE AUTOMATIC GATE MANUFACTURERS s.n.c. Made in Italy Distributor s box The manufacturers reserve the right to change the products without any previous notice and are not liable for possible damages to people and properties. Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a. - Fax +39 0442 331054 - e-mail: info@fadini.net - www.fadini.net