Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and recyclable polypropylene (PPH) with no air leakage. All fan mounting hardware in stainless steel. Rotatable to any of 8 standard discharge positions by 45 increments. * with the exception of STORM 10: PE. Wheels: PP Forward curved centrifugal type impeller made of injection molded PPH. Fan wheel supplied with motor shaft bushing and hub cap constructed of PPH. Wheels electronically and dynamically balanced. LG/CCW rotation only. Motors Direct drive, asynchronous, single or three phase, IP55. Single speed: three phase 230/400V-/60 Hz, single phase 230V-Hz. Explosion proof motors available on request. Motor is outside the corrosive airstream. Three phase motors speed adjustable by variable frequency inverter drive. STORM 10 is also available with external rotor IP 20 motor for quiet performance. Motor support Several options: no stand, metal stand or polypropylene motor pedestal. ATEX SEAT Series Fans are also available in ATEX Zone II, known outside Europe as explosion proof, category 3 G execution in accordance with ATEX directive 94/9/CE. ATEX declaration of conformity avaiiable on our web site www.seat-ventilation.com. The performances curves of explosion proof fans are identical with the ones of the standard version. Performance Fan performance based on tests conducted in accordance ith AMCA 210-85 and ISO 5801. Temperature resistance PPH casing and wheel recommended up to 60 C. Warranty SEAT VENTILATION warrants its equipment to be free from defects in workmanship and material under normal use and service for two years after shipment. Warranty is void if damage results from improper wiring or installation.
Electrical data and weight* RPM (T/min) (kw) (V) AMP draw (A) Weight (Kgs) Reference Single phase 1 0,06 230 0,31 2,10 61102010 STORM 10 1 0,06 230 1,12 2,70 61102010 3000 0,12 230 1,20 4,40 61103010 STORM 12 1 0,25 230 2, 7,80 61122010 3000 0,37 230 3,10 5,60 61123010 STORM 14 3000 1,10 230 5,40 12,80 61143010 Three phase STORM 10 1 0,09 230/400 0,63/0,37 3, 61102000 3000 0,12 230/400 0,80/0,46 5,30 61103000 1400 0,18 230/400 1,13/0,65 8,60 61122000 STORM 12 1400 0,25 230/400 1,70/0,96 7,30 61122000 3000 0,37 230/400 1,68/0,96 7,40 61123000 STORM 14 3000 1,10 230/400 4,70/2,70 15,70 61143000 STORM 16 3000 2,20 230/400 8,80/5,10 22,60 61163000 ATEX STORM 10 ATEX 1 0,06 230/400 0,61/0,35 5,00 61102003 3000 0,12 230/400 0,69/0,4 5,30 61103003 STORM 12 ATEX 3000 0,37 230/400 1,64/0,95 12,30 61123003 STORM 14 ATEX 3000 1,10 230/400 4,33/2,5 15,40 61143003 STORM 16 ATEX 3000 2,20 230/400 8,00/4,60 29,70 61163003 *Tabulated current values are approximate and depend on make and model of the motor. Assembly drawing for Storm 12, Storm 14 and Storm 16 Motor Impeller Housing Motor support stand Motor plate Hub cap
PS (Pa) STORM 10 6 600 3440 rpm Standard Hz 60 Hz AMCA 210-85 ISO 5801 5 Static Pressure 4 400 3 300 200 1 100 M 3 /H CFM rpm, 0.12 kw 2200 rpm rpm 1425 rpm, 0.06 kw 100 1 200 29 58 87 116 145 DYNAMIC PRESSURE Housing and motor noise level when fan is running near maximum output Type D Ducted inlet/ Ducted outlet Noise level type B. Visit our website for details. 5D 210-85 Nozzle Chamber Noise level in octaves () n (T/min) (A) (A) Frequency Hz 1435-2870 3400 1435 62,9 51,6 1435 52,3 61,6 49,8 54,5 66,9 73,2 68,1 56,5 57,1 67,4 45,2 49,6 64,8 69,3 2870 81,1 69,6 2870 69,7 80,8 49,8 53,1 60,3 64,4 3440 85,5 74,4 3440 74,1 85,2 (ISO 13347)
STORM 10 P1 P C E N H L M int. X G ext. B Metal stand Motor guard for single phase external rotor motor only A 4 holes ø 5 L M Y1 3 spacer feet around ø 1 10 Y Z LG POSITION ONLY Available in ATEX version Dimensional data (mm). Metal stand does not come standard with fan (see accessories pricing). The motor frame size may vary upon type of motor used. A B C E G H L M N Y Y1 Z X 115 135 127 75 158 97 32 48 57 137 120 100 165 135 Motor type Moteur P1 P Single phase, rotor exterior, IP20 with cover 173 205 ATEX Three phase 262 295 Three phase, IP55 253 285 Handings with IP55 motor type are viewed from inlet side - 45 degree adjustable LG 0 LG 45 LG 90 LG 135 LG 180 LG 225 LG 270 LG 315 LG 0 and LG 90 are handings with IP20 motor type.
PS (Pa) 1400 STORM 12 1200 3440 rpm Static Pressure 800 600 400 200 M 3 /H CFM rpm, 0.37 kw 2200 rpm rpm 14 rpm, 0.25 kw Standard Hz 60 Hz AMCA 210-85 ISO 5801 100 200 300 400 600 700 58 116 174 232 290 348 406 Type D Ducted inlet/ Ducted outlet Housing and motor noise level when fan is running near maximum output n (T/min) 14 60,4 65,2 76,8 80,5 (A) 56,8 61,5 74 77,8 5D Noise level type B. Visit our website for details. 14 (A) 69,9 71,7 73,5 75,3 84,2 85,8 87,4 88,8 210-85 Nozzle Chamber 82 83,9 86,9 87,6 98,7 98,1 101,9 100,9 (ISO 13347) DYNAMIC PRESSURE Frequency Hz 100 2 0 14 79,9 71,9 63,6 66,4 55,7 47,7 43,3 Noise level in octaves () 83,2 75,6 74,5 72,4 62,5 52,2 47,7 2870 92,5 88,5 76,4 72,6 76,4 63,3 62,4 95,6 91,4 81,9 83,1 81,9 69,6 66,3 0 41,4 45,7 58 61,9
STORM 12 P C E X X 1 A B G H 10 mm 4 x 6 L M Y Z 10 N LG POSITION ONLY Available in ATEX version Dimensional data (mm). Metal stand does not come standard with fan (see accessories pricing). The motor frame size may vary upon type of motor used. A B C E G H L M N P Y Y1 Z X X1 145 175 163 90 212 130 45 80 72 152 3 180 160 340 240 71 Handings with IP55 motor type are viewed from inlet side - 45 degree adjustable LG 0 LG 45 LG 90 LG 135 LG 180 LG 225 LG 270 LG 315
PS (Pa) 2 2000 STORM 14 3440 rpm Standard Hz 60 Hz AMCA 210-85 ISO 5801 17 Static Pressure 1 1 7 rpm, 1.1 kw 2200 rpm rpm M 3 /H 200 400 600 800 1200 1400 CFM 116 232 348 464 580 696 812 DYNAMIC PRESSURE Type D Ducted inlet/ Ducted outlet Housing and motor noise level when fan is running near maximum output n (T/min) (A) 5D Noise level type B. Visit our website for details. (A) 210-85 Nozzle Chamber Noise level in octaves () Frequency Hz 100 14 81,5 76,9 86 80,1 2870 104,7 90,2 107,9 94,2 14 65,4 61,1 14 72,5 75 87,2 87,3 74,7 70,5 87,3 87 69,1 69,1 76,4 78,8 93,1 90,8 69,1 72,9 84,1 79,3 82,1 78 88,1 89,3 109,3 105,8 61,4 67,5 80 83,2 86,7 81,8 91,3 93,1 112,4 110,5 2 54,6 59 71,8 76,9 (ISO 13347) 0 54,3 69,3 73,2 0 48,3 52,6 64,7 68,5
STORM 14 P C E X X 1 A B G H 10 mm 4 x 6 L M Y Z 10 N LG POSITION ONLY Available in ATEX version Dimensional data (mm). Metal stand does not come standard with fan (see accessories pricing). The motor frame size may vary upon type of motor used. A B C E G H L M N P Y Y1 Z X X1 188 232 227 125 218 170 55 110 83 193 433 180 160 340 240 80 Handings with IP55 motor type are viewed from inlet side - 45 degree adjustable LG 0 LG 45 LG 90 LG 135 LG 180 LG 225 LG 270 LG 315
PS (Pa) 3 3 3000 STORM 16 3440 rpm Standard Hz 60 Hz AMCA 210-85 ISO 5801 27 2 Static Pressure 2 2000 17 1 1 rpm, 2,2 kw 2200 rpm 7 rpm DYNAMIC PRESSURE M 3 /H 1 2000 2 3000 CFM 290 580 870 1160 14 1740 Type D Ducted inlet/ Ducted outlet Housing and motor noise level when fan is running near maximum output n (T/min) (A) 5D Noise level type B. Visit our website for details. (A) 210-85 Nozzle Chamber Noise level in octaves () Frequency Hz 100 14 85,5 87 95,8 83,2 2870 107,9 94,2 111,1 104 14 90,6 77,7 14 77,7 79,3 90,6 92,6 74,3 80,1 94 97,3 99,1 81,8 81,8 83,3 99,1 98,2 70,9 75,3 84,1 89,3 115,8 93,8 93,8 94,8 115,8 110 69,2 73,6 83,4 87,3 119 97 97 98,2 119 114,2 2 62,9 67 80,3 84,7 (ISO 13347) 0 57,8 64,2 77,5 81,2 0 49,7 56,1 72,5 78,4
STORM 16 P C E X X 1 A B G H 10 mm 4 x 6 L M Y Z 10 N LG POSITION ONLY Available in ATEX version Dimensional data (mm). Metal stand does not come standard with fan (see accessories pricing). The motor frame size may vary upon type of motor used. A B C E G H L M N P Y Y1 Z X X1 235 288 278 160 262 205 40 100 97 197 477 240 160 420 300 90 Handings with IP55 motor type are viewed from inlet side - 45 degree adjustable LG 0 LG 45 LG 90 LG 135 LG 180 LG 225 LG 270 LG 315