ECT Applications. Features

Similar documents
Industrial Pressure Transmitter

Marine Pressure ECTN Applications. Features

EPI Applications. Features

EPN/EPNCR Applications. Features

FPT Applications. Features

Submersible Pressure

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

Temperature switch. Switching output 2 transistors PNP Logger Ring buffer: 3518 data points Sampling time: s, Off (0)

Ex Pressostat EXPK 944/947/953. Applications. Features

Ministat M/MS 624/634. Applications. Features

Pressure transmitterses. По вопросам продаж и поддержки обращайтесь: Единый адрес для всех регионов:

Railway technology. Pressure and temperature monitoring solutions. NN Pressure switches. NN Pressure transmitters. NN Thermostats

Alterostat M2S 104/114. Applications. Features

Alterostat M2S 104/114. Applications. Features

Thermostat for shipbuilding Switching differential Not adjustable

JUMO MIDAS Pressure transmitter

JUMO MIDAS S05 Pressure transmitter Type

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

MBS 1200 and MBS 1250

Electronic Pressure Switches

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Electronic Pressure Switches

Pressostat P/PS 900/904/912. Applications. Features

Electronic Pressure Switch EDS 3000

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

OEM Pressure Transmitters

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Pressure Transmitters

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Pressure transmitters for heavy duty applications Type MBS 3250

G 1/4 A DIN 3852 (bar version) ±0.5 %FS max

Type A-10 General Purpose Pressure Transmitters

Pressure transmitter for industrial applications Type MBS 4500

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Pressure transmitters for heavy duty applications MBS 3200 and 3250

OEM relative pressure transmitter type 506

OEM Pressure Transmitters

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Pressure transmitters for industrial applications Type MBS 4510

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Pressure transmitter for industrial applications Type MBS 4510

Pressure transmitter for air and water applications Type MBS 1900

Data Sheet P1A Pressure Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Type A-10 General Purpose Pressure Transmitter

Pressure Sensors. for liquid and gaseous media

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Electronic Pressure Switches

Industrial Pressure Transmitters

Pressure sensor for liquid and gaseous media QBE620-P...

Seal material. Pressure range. Pressure connection -40 F +212 F 1 -4 F +257 F 3

Pressure Sensor - EPT3100

Pressure transmitter for marine applications MBS 3100 and MBS 3150

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Electronic pressure switch with integrated analogue output

M5200 Industrial Pressure Transducer

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Adjustment range. Seal material. Pressure connection

INSERTION flow sensor for continuous flow measurement

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Pressure Transmitter JUMO dtrans p30 Type

CTE8000 / CTU8000 Series

Relative and absolute pressure transmitter type 528

Electronic Pressure Switches

Pressure transmitter for elevated media temperatures

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

P255 Stainless Steel Pressure Transducer

P1A Pressure Sensor. Description. Features. Applications MAIN FEATURES

Electronic Temperature Sensor ETS 300

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

OsiSense XMLP Pressure Transmitters for Industrial Applications. Catalog

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Special Purpose Transmitters

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Pressure transmitter for marine applications MBS 33M

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

Pressure transducer DMU 01K Compact version

Paddle-wheel flow controller for On/Off control

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

SSI Technologies MediaSensor

Condensed Catalog 2006 North America

Pressure Transmitter JUMO dtrans p30 Type

Relative and absolute pressure transmitter type 691

Transcription:

Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The economical pressure transmitter ECT 847 is based on the tried and true ECT line of transmitters. The wide media temperature range from -5 to 5 C in combination with a comprehensive set of of features and options makes the ECT 847 pressure transmitter a versatile solution suitable for most industrial applications. Applications Machine tools Hydraulics Water treatment Features Excellent media compatibility Relative or absolute pressure measurement Titanium version optional Frontal membrane optional Data sheet 0/09 Technical Data Measuring principle Thick-film-on-ceramic Accuracy @ 5 C typ. ± 0.5 % FS typ. Measuring range Output signal 0... to 0... 400 bar 0... 5 to 0... 5000 psi 4... 0 ma, 0... 5 VDC,... 6 VDC, 0... 0 VDC, 0.5... 4.5 VDC ratiom. Media temperature Ambient temperature -5 C... +5 C 400 bar/5000 psi: -0 C... +5 C -5 C... +5 C Cable PVC : -5 C... +60 C Cable PUR 4: -0 C... +70 C Cable Raychem 08: -0 C... +00 C Subject to change Trafag sensors & controls Switzerland Industriestrasse 8608 Bubikon Tel. +4 44 9 Fax +4 44 9 www.trafag.com trafag@trafag.com

Ordering information/type code Measuring range ) Sensor Pressure connection Electrical connection Output signal Pressure measurement range Over pressure Burst pressure 0....0 7 0....6. 4.8 7 0....5 5 7.5 75 0... 4 8 76 0... 6 5 77 0... 0 0 5 78 0... 6 40 79 0... 5 50 75 80 0... 40 80 00 8 0... 60 0 80 8 0... 00 4) 00 00 8 0... 60 4) 0 480 85 0... 50 4) 500 750 74 0... 400 ) 4) 800 000 84 Relative pressure, Material pressure connection and housing:.405 (AISI0) 57 Relative pressure, Material pressure connection and housing:.4404/.445 (AISI6L) 4) 59 Relative pressure, Material pressure connection and housing:.446 (AISI8LN) 4) 5 Relative pressure, titanium grade 5 4) 5 Pressure measurement range [psi] Over pressure [psi] Burst pressure [psi] 0... 5 0 40 G 0... 0 45 70 G 0... 0 60 90 G5 0... 50 00 50 G6 0... 00 00 50 G7 0... 50 00 75 G8 0... 50 500 65 G9 0... 400 800 00 H0 0... 500 000 50 H 0... 000 000 000 H 0... 500 4) 000 4500 H 0... 000 4) 4000 6000 H5 0... 000 4) 6000 9000 G4 0... 5000 ) 4) 0000 500 H4 Absolute pressure, Material pressure connection and housing:.405 (AISI0) ) 87 Absolute pressure, Material pressure connection and housing:.4404/.445 (AISI6L) ) 4) 89 Absolute pressure, Material pressure connection and housing:.446 (AISI8LN) ) 4) 8 Absolute pressure, titanium grade 5 ) 4) 8 847. XX XX XX XX XX XX G/4" female 0 G/4" male 7 G/" male DIN85-A 4) G/" male DIN85-E 4) 4 /4" NPT male, ANSI B.0. 4) 0 /8" NPT male, ANSI B.0. ) 4 7/6"-0UNF male SAE4 (J96) 4) 4 7/6"-0UNF male, DIN866 ) 8 7/6"-0UNF female SAE J5 with valve opener ) 4 R/4" male, DIN858 9 G/4" frontal membrane 4) 7) 5 Male electrical plug EN 750-80-A (DIN4650-A), Mat. PA 05 Male electrical plug Mx, 5-pole, Mat. PA (Old shape), Mat. PBT (New shape) 5 Male electrical plug Packard Metri Pack, Mat. PBT 5 Male electrical plug industrial standard (contact distance 9.4 mm), Mat. PBT 0 Cable PUR (Screwed cable gland PA 6-), -0 C +70 C 5) 6) 4 Cable PVC (Screwed cable gland PA 6-), -5 C +60 C 5) 6) 9) Cable Raychem (Screwed cable gland PA 6-), -0 C +00 C 5) 6) 9) 08 Signal output Load resistance I (supply) U (supply) 4... 0 ma (Usupply-9 V) / 0 ma 9... 0 VDC 9 0... 5 VDC.5 kω 0 ma 0... 0 VDC 4... 6 VDC 5.0 kω 0 ma 0... 0 VDC 6 0... 0 VDC 5.0 kω 0 ma 5... 0 VDC 7 0.5... 4.5 VDC ratiometric 5.0 kω 0 ma 5 VDC ± 0.5 VDC ratiom. page /8

847. XX XX XX XX XX XX Accessories Seal FKM (-0 C... +5 C) 6 Seal CR 00 bar (-5 C... +00 C) 8) 6 Seal EPDM (-5 C... +5 C) 6 Pressure peak damping element ø.0 mm, material.405 0) 40 Pressure peak damping element ø 0.4 mm, material.405 (sensors 57, 87) resp..4404 (sensors 5, 5, 59, 8, 8, 89) 0) 44 Female electrical connector EN 750-80-A (DIN4650-A)/NBR, -40 C... +90 C 58 Female electrical connector EN 750-80-A (DIN4650-A)/Silicone, -40 C... +5 C 56 Female electrical plug Mx, 5-pole Female electrical connector industrial standard 4 Special electrical connection: Pin +, Pin - (only for output signal 4... 0 ma and male electrical plug EN750-80-A / DIN4650-A) 9 Special electrical connection: Pin Out, Pin -, Pin + (only for output 4, 6, 7, and male electrical plug EN750-80-A / DIN4650-A) 98 Special electrical connection: Pin +, Pin -, Pin Out (only for output signals 4, 6, 7, and male electrical plug EN 750-80-A / DIN 4650-A) 97 Special electrical connection: Pin +, Pin - (only for output 4... 0 ma and male electrical plug Packard Metri Pack -poles) E4 Special electrical connection: Pin +, Pin Out, Pin - (only for output signals 4, 6, 7, and male electrical plug Packard Metri Pack -poles) 99 Special electrical connection: Pin +, Pin -, Pin 5 Ground (only for output signal 4... 0 ma and male electrical plug 5, Mx, 5-pole) 94 Special electrical connection: Pin Out, Pin -, Pin +, Pin 4 Ground (only for output signals 4, 6, 7, and male electrical plug 0, industrial standard) E Cable length.5 m M Cable length.0 m M Cable length 5.0 m 5M Housing nut for electrical connection EN750-80-A (DIN4650-A) secured with Loctite (max. 85 C) L9 Multiple packaging ) VM ) Extended overpressure as well as customized pressure ranges upon request ) Media -0 C... +5 C ) max. 40 bar 4) Upon request 5) Cable length see accessories (max. length 50 m, in 5-meter sections) 6) Protection IP68: Immersion depth max. m, Media +0 C +5 C 7) Not for sensors 57 and 87, only for pressure ranges 5 bar or 400 psi 8) Only for pressure connections 0, 0, 4, 4, 8, 4, 9 9) Pressure ranges > 6 bar (Pressure ranges 6 bar upon request) 0) Not for pressure connections 0, 8, 4, 5 ) Only for sensors 59 and 89 and electrical connections 0, 5, 5 (others on request) ) The order quantity must be a multiple of 50, only for electrical connections 05 and 5 Ni Identical construction for refrigeration: Data sheet No. H7 page /8

Standard products (extra short lead time) Product No. Type Code Pressure range Over pressure max. Signal output Supply [VDC] ECT.0A 847 7 577 05 0000 0000 9 58 6 0.... 4... 0 ma 9... 0 ECT.6A 847 7 577 05 0000 0000 9 58 6 0....6. 4... 0 ma 9... 0 ECT.5A 847 75 577 05 0000 0000 9 58 6 0....5 5 4... 0 ma 9... 0 ECT4.0A 847 76 577 05 0000 0000 9 58 6 0... 4 8 4... 0 ma 9... 0 ECT6.0A 847 77 577 05 0000 0000 9 58 6 0... 6 4... 0 ma 9... 0 ECT0.0A 847 78 577 05 0000 0000 9 58 6 0... 0 0 4... 0 ma 9... 0 ECT6.0A 847 79 577 05 0000 0000 9 58 6 0... 6 4... 0 ma 9... 0 ECT5.0A 847 80 577 05 0000 0000 9 58 6 0... 5 50 4... 0 ma 9... 0 ECT40.0A 847 8 577 05 0000 0000 9 58 6 0... 40 80 4... 0 ma 9... 0 ECT60.0A 847 8 577 05 0000 0000 9 58 6 0... 60 0 4... 0 ma 9... 0 ECT.0V 847 7 577 05 0000 0000 7 58 6 0.... 0... 0 VDC 5... 0 ECT.6V 847 7 577 05 0000 0000 7 58 6 0....6. 0... 0 VDC 5... 0 ECT.5V 847 75 577 05 0000 0000 7 58 6 0....5 5 0... 0 VDC 5... 0 ECT4.0V 847 76 577 05 0000 0000 7 58 6 0... 4 8 0... 0 VDC 5... 0 ECT6.0V 847 77 577 05 0000 0000 7 58 6 0... 6 0... 0 VDC 5... 0 ECT0.0V 847 78 577 05 0000 0000 7 58 6 0... 0 0 0... 0 VDC 5... 0 ECT6.0V 847 79 577 05 0000 0000 7 58 6 0... 6 0... 0 VDC 5... 0 ECT5.0V 847 80 577 05 0000 0000 7 58 6 0... 5 50 0... 0 VDC 5... 0 ECT40.0V 847 8 577 05 0000 0000 7 58 6 0... 40 80 0... 0 VDC 5... 0 ECT60.0V 847 8 577 05 0000 0000 7 58 6 0... 60 0 0... 0 VDC 5... 0 page 4/8

Specifications Accuracy TEB typ. @ -5... +85 C ±.0 % FS typ. Accuracy @ 5 C typ. NLH @ 5 C (BSL) typ. TC zero point and span typ. Long term stability year typ. ± 0.5 % FS typ. ± 0. % FS typ. ± 0.0 % FS/K typ. ± 0. % FS typ. Electrical Data Output / supply voltage 4... 0 ma: 4 (9... 0) VDC 0... 5 VDC: 4 (0... 0) VDC... 6 VDC: 4 (0... 0) VDC 0... 0 VDC: 4 (5... 0) VDC 0.5... 4.5 VDC ratiom. Rise time Typ. ms / 0... 90 % nominal pressure Switch-on-delay Inverse-polarity protection, short-circuit strength @ 5 C during 5 min. Max..5 s 4... 0 ma: to U s = 0 VDC 0... 0 VDC, 0... 5 VDC,... 6 VDC: to U s = 0 VDC 0.5... 4.5 VDC ratiometric: to U s = 5.5 VDC Environmental conditions Media temperature -5 C... +5 C 400 bar/5000 psi: -0 C... +5 C Ambient temperature -5 C... +5 C Cable PVC : -5 C... +60 C Cable PUR 4: -0 C... +70 C Cable Raychem 08: -0 C... +00 C Protection ) IP65, IP67, IP68 Humidity Vibration Shock Max. 95 % relative 4 g (0...000 Hz) 50 g / 8 ms EMC Protection Emission EN/IEC 6000-6- Immunity EN/IEC 6000-6- Mechanical Data Sensor (wetted parts) Ceramic, Al O (96 %) Pressure connection (wetted parts) Housing Sealing Male electrical plug Weight Mounting torque 57/87:.405 (AISI0 59/89:.4404/.445 (AISI6L) 5/8:.446 (AISI8LN) 5/8: Titanium Grade 5 57/87:.405 (AISI0 59/89:.4404/.445 (AISI6L) 5/8:.446 (AISI8LN) 5/8: Titanium Grade 5 FKM 70 Sh, CR, EPDM See ordering information ~ 0 g 5... 0 Nm ) See electrical connection page 5/8

Measuring accuracy 0.5 % ECT 847 Accuracy (%) 8 7 6 5 4 0 - - - -4-5 -6-7 -8-0 -0-0 0 0 0 0 40 50 60 70 80 90 00 max. typ. TEB (-5...+85 C) Temp. ( C) Electrical connection Protection / electrical connection IP65* ) IP67* ) IP67* ) IP65 IP68 max. m Industrial standard EN750-80A ** ) 05 Mx ** ) 5-pole 5 4 5 Packard Metri Pack ** ) -pole 5 Industrial standard Contact distance 9.4 mm ** ) 0 Cable** ) 4/ IP68 max. m Cable ** ) 08 Standard 9 Standard 94 E4 Output signal P 4-0mA I 847.xx.xxxx.xx.9 P U Us (pos. Supply) Us (neg. Supply) Earth (housing) Shield*** ) for DC Supply Output Common Earth (housing) Shield *** ) <e> <e> Standard 98 97 e e e 4 5 5 4 5 99 <e> E e e white brown yellow white green brown yellow red black green red white black green 847.xx.xxxx.xx.4/6/7/ * ) Provided female connector is mounted according to instructions ** ) Ventilation via male electric plug/cable end *** ) Only cable versions or female electrical plug with shield connection Additional information Documents Data sheet www.trafag.com/h74 Instructions www.trafag.com/h74 Flyer www.trafag.com/h7066 page 6/8

Dimensions 6 8 with male thread 48.5 50.5 with female thread 40.5 Ø 4 Ø 9.405 847.XX.XXXX.05.XX.XX 847.XX.XXXX.5.XX.XX 847.XX.X77.5.XX.XX 847.XX.X94.5.XX.XX 9 5.5.5 5.5 9 8.5 Ø 9.405 Ø 9.405 847.XX.XXXX.5.XX.XX 847.XX.X77.5.XX.XX 847.XX.X94.5.XX.XX 847.XX.XXXX.0.XX.XX.5 8.5 6 8 with male thread 48.5 50.5 with female thread 5.5 customer spec. length 5 5 Ø /Ø 4.5 Ø 4.8 - Ø 6. 847.XX.X77.0.XX.XX 847.XX.X94.0.XX.XX 847.XX.XXXX./4/08.XX.XX page 7/8

Dimensions 4.5 (5) 4 8 (8.5) 4.5 Ø G/4.5 Ø 5.05xU G/4" Seal DIN869 Ø9.5 G/" DIN85-A 9. 7/6"-0UNF SAE4 (J96) ø9.5 M 5x7 G/" DIN85-E Seal DIN869 847.XX.XX0.XX.XX.XX 847.XX.XX7.XX.XX.XX 847.XX.XX.XX.XX.XX 847.XX.XX4.XX.XX.XX 7 5. 0 6.7.5 /4-8 NPT ANSI B.0. ø9.5 7/6-0UNF DIN866 847.XX.XX0.XX.XX.XX 847.XX.XX4.XX.XX.XX 847.XX.XX8.XX.XX.XX 7/6"-0UNF SAE J5 7/6"-0UNF SAE J5 0 Ø Ø0 /8-8 NPT ANSI B.0. ø9.5 847.XX.X94.XX.XX.XX 8.6 4 4.5.5 8.6 R/4" DIN858 847.XX.XX4.05.XX.XX.XX 847.XX.XX4.XX.XX.XX 847.XX.XX9.XX.XX.XX Bore M :.5.7 6 - with male thread G/4" 0 Ra.6 Ø H8 R 6 G/4" G/4" ~Ø 0.5 O-Ring Ø0x.5 Sealing DIN/ISO 869.9x9.x.5 847.XX.XX5.XX.XX.XX Ø 9 SW6 Ø 4 Ø Ø 50 Welding flange for G/4" frontal membrane (.40) Ordering No. C7805 6 5.5 7 0 5.5 8.5 5.8 5.5 ~Ø0 54... 60 max. 5 mm 6 M ) M ) M 7 ) Tightening torque 50...60 Ncm ) Tightening torque 50...60 Ncm 847.XX.XXXX.XX.XX.56 847.XX.XXXX.XX.XX.58 847.XX.XXXX.XX.XX. 847.XX.XXXX.XX.XX.4 page 8/8