Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

Similar documents
Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

Panther HP Oil Pump Series

Lion HP 50:1 Grease Pump Series

PANTHER HP SERIES OIL PUMPS 3:1 Model # Bare Pump # Flange Mount 5:1 Model # Bare Pump # Flange Mount

Premium Series Grease Dispensing Handle One and Two Piece Body Styles

SERVICE INSTRUCTIONS. Material Pump

In-Line Fluid Meters Models: Liter Pint Quart Gallon

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

Service Guide. High-Pressure Grease Pump. 100 psi (6.8 bar) High-Pressure Pump Model 7785 Series Specifications

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

Stub pump 3:1. User and maintenance instructions. Models and , series D. Date of issue December Form number

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

SERVICE INSTRUCTIONS. Transfer Pump

SINGLE ACTION FLUID PUMP

Oil & Light Fluid Pumps

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

In-Line Electronic Control Handle

Air Operated 1:1 Oil Ratio Pump OP-11

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

#9040 FUEL TANK SWEEPER

CenterFlo Pumps. Air Operated Double Diaphragm (AODD) Pumps. Automotive Commercial Industrial

OPERATOR S MANUAL A

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

OPERATOR S MANUAL SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

Polypropylene Piston Drum Pumps

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Instructions Parts List

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

SERVICE GUIDE 8540-B 8549-B C. High-Pressure Lubricant Pump DESCRIPTION. Pump Assembly. Specifications

Air Operated Grease Ratio Pumps 50:1 BGRP

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA

Model S Table of Contents

IMPULSE METERS Oil Inventory Control

Instructions Parts List

Model 1210C Battery Powered Pump Shown

1/2" AIR DRIVEN DIAPHRAGM PUMP

Instructions Parts List

7783-A B C4

P-200 Plastic Utility Pump for Petroleum Products

Air operated chassis pump

D Instructions/Parts. Siphon Feed Detail Spray Gun D

1600 PSI ELECTRIC PRESSURE WASHER

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Calcium Chloride Pump

fusion RF Control Handle

Husky 715 Air-Operated Diaphragm Pumps

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

1-1/2" DIAPHRAGM PUMP 1:1 Ratio (metallic) with Cone Checks

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

High pressure stripped pump

Model S Metallic Design Level 1

Instructions - Parts List Sanitary Series FDA-Compliant Diaphragm Pumps

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM

Husky 1040 Air-Operated Diaphragm Pumps

50:1 Grease Pump Kits

Instructions Parts List

M-1115S Series Fuel Pump

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS

Air Operated Diaphragm Pumps

MODEL T26746 FOOT-OPERATED GREASE PUMP INSTRUCTIONS

Husky 307 Air-Operated Diaphragm Pumps

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Binks FRX20 FLUID SECTION

Page 1 of 19. Part# /10/2006

herkules 338 Air Operated Diaphragm Pump

Instructions Parts List

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

UV PROCESS SUPPLY, INC.

OPERATOR'S MANUAL FOR DOUBLE ACTING PISTON HAND PUMP

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

The History of Balcrank

Pump Operating and Maintenance Manual - Models

Husky Sanitary Series FDA-Compliant Diaphragm Pump

Husky Sanitary Series FDA-Compliant Diaphragm Pump

Air Operated Diaphragm Pumps

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

Electric Diesel Pump EDP/12, EDP/24

M-3025CB-AV Fuel Pump

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

Instructions-Parts 3D150, 3D350, 4D150, Diaphragm Pump G EN

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

12 Volt DC Diaphragm Pumps Series 400

SERVICE KITS REBUILD KIT DESCRIPTION CHART MODEL DESCRIPTION CHART SPECIFICATIONS X X 1 - B X - X X X - B

Fluid Dispensing Systems. Automotive Commercial Industrial

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

Model 8329 Table of Contents

Transcription:

SERVICE BULLETIN SB1101 Revision F 10/13 Lynx 3:1 Pump Model: 1110-007 Thoroughly read and understand this manual before installing, operating or servicing this equipment. OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

GENERAL SAFETY REQUIREMENTS NOTE: THOROUGHLY READ AND UNDERSTAND THIS MANUAL BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT. PRESSURE RELIEF PROCEDURE: Follow this procedure whenever you shut off the pump, when checking or servicing any part of the system and when installing, cleaning or changing any part of the system. 1 ) Disconnect the air to the pump. 2) Point dispensing valve away from yourself and others. 3) Open dispensing valve until pressure is relieved. Because this pump can be incorporated into pressurized systems, the following safety precautions should be observed. Check equipment regularly and repair or replace worn and damaged parts. Never alter or modify any parts of this pump, doing so may cause damage to pump and/or personal injury. Under no circumstances should the dispensing valve be aimed at any person at any time. Personal injury may result. Release pressures built up in the system before any service or repair is begun. See the pressure relief procedure below. Do not operate this pump above 150 PSI (10.3 BAR) air inlet pressure. Always read and follow the fluid manufacturer s recommendations regarding the use of protective eyewear, clothing and respirators. IMPORTANT Pump develops 450 PSI (31 BAR) maximum working pressure at 150 PSI (10.3 BAR) maximum inlet air pressure. Be sure that any components or accessories used in the system are rated to withstand this pressure. To determine fluid outlet pressure, multiply the ratio of the pump by the air pressure being used. EX: 3.1 (3:1 ratio) x 100 PSI = 300 PSI fluid pressure. 3.1 (3:1 ratio) x 6.9 BAR = 20.6 BAR fluid pressure. DANGER: Not for use with fluids that have a flash point below 100 F (38 C). Examples: gasoline, alcohol. Sparking could result in an explosion which could result in death. In the presence of explosive vapors, take action to prevent static sparking. Failure to ground the pump, piping, valves, containers, or other miscellaneous equipment can result in fire or explosion. NOTE Note: Thermal expansion of the fluid in a distribution system can cause an increase in system pressure that can damage fluid distribution system components. Pressure relief valve, 3120-019 is recommended. Do NOT use with solvents or other explosive fluids. An explosion can result in the pump when aluminum & zinc parts come in contact with certain solvents. 2

TABLE OF CONTENTS Cover...1 General Safety Information...2 Technical Data...3 Dimensional Data...3 Installation/Operation...4 Servicing...5 Troubleshooting...5 Parts Listing... 6 & 7 Warranty...8 TECHNICAL DATA Pressure Ratio...3:1 Air Pressure Operating Range...45-150 psi Maximum Fluid Working Pressure...450 psi Cycles Per Gallon...98 cpg Delivery per minute...6.6 gpm Air Inlet Port Size...1/4 NPTF Fluid Inlet Port Size...3/4 NPTF Fluid Outlet Port Size...3/4 NPTF Noise Level... 79 dba @ 85 psi Wetted Parts...Steel, Brass, Aluminum, Polyurethane, Buna-N Product Description The Lynx 3:1 pump is designed to deliver a range of light weight oils including gear oils. The pump s 2 bung adapter allows installation directly onto original containers or bulk tanks. The Lynx pump accepts a variety of different length and types of extension and/or suction tubes. Motor oil SAE 10-30 @ 68 0 F, air pressure 150 psi and free flow. 68 0 F A pump s ability to deliver oil is based on the pressure (bar/psi) and quantity of air supplied to the air motor and the amount of material discharge (back) pressure to be overcome within the system. 145 psi 100 psi 58 psi 3

DIMENSIONS GENERAL SAFETY The pump is intended for non-corrosive and 7. petroleum based liquids. It may NOT be used for other purposes or for pumping gasoline, or other explosive liquids. Check that all components used are suitable 8. for the operating pressure of the system. Do not use higher pressure than required for the satisfactory functioning of the system. Before work is undertaken on the pump the compressed air should be disconnected from the pump and the whole system should then be depressurized. Check all components thoroughly for damage and leakage. Ensure that the compressed air is disconnected from the pump and the system is depressurized when system is not in use (i.e. overnight or during longer shut down periods) as there is always a risk of hoses bursting or pipework leaking etc. 4 The pump is made up of two main parts: A compressed air operated two way piston air motor and a double acting liquid pump. The liquid is sucked into the pump tube via the bottom valve. When the piston moves upwards liquid is forced out of the fluid outlet. The fluid is forced out of the pump when the piston is moving in both directions. The relationship between the air piston and the pump piston determines the ratio of the pump. If the pump ratio is 3:1 the theoretical fluid pressure will be 3 times to the air pressure, when the pump stalls out. The air is exhausted from the pump via a sound attenuator. INSTALLATION / OPERATION 3. 4. 5. 6. To achieve long pump life we recommend that filter regulator to be installed prior to the air inlet of the pump. Remove the protective packaging from the pump and also the protective plugs. Fit the 2 pump adaptor firmly on to the barrel. Mount the pump into the pump adaptor and lock into position. Fit and secure the outlet hose. Fit and secure the air inlet hose, slowly increase the air pressure letting the pump slowly build up fluid pressure. Ensure there are no leaks either on the air inlet or at the fluid outlet. To obtain maximum vacuum all connections should be sealed and tight. Slowly increase the air pressure to optimum working pressure. The maximum permitted air pressure is 150 psi, do not exceed this limit. Service: Before any servicework is carried out the compressed air must be turned off to the pump or the air coupling disconnected. The fluid outlet must be depressurized completely. Follow pressure relief procedure.

MAINTENANCE SERVICE 3. 4. 5. 6. Before any service work is carried out the compressed air must be turned off to the pump or the air coupling disconnected. The fluid outlet must be depressurized completely. Clean the air filter, remove all pollutants including condensed water. Check system for any air or fluid leaks. Always keep the equipment clean and remove foreign objects, ensure no pollutants enter the barrel as these will be pumped into the system. When changing the barrel make sure the pump remains clean (Do not put on to floor otherwise the oil will become polluted). When depressurizing the system or removing the outlet hose from the pump ensure there is a container available to drain the excess fluid into. 3. 4. For your personal safety ensure the air is disconnected from the pump and the fluid discharge is depressurized before any service is carried out. Be cautious when repressurizing the system after any service work is carried out. During service procedures it is important to avoid any scratching or any other damage to gasket or bearings surfaces. Keep tools and benches clean. Be extremely cautious when assembling or dismantling V-pack ings and O- rings. Exchange all worn or damaged parts no matter how slightly damaged they seem. Clean and grease all gasket, bearing surfaces including O-rings and gaskets with teflon grease when reassembling pump. Try to use paraffin to clean pump parts. If water based cleaners are used, wipe parts clean & dry immediately to avoid corrosion. TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE REMEDY The pump is not working or there is no oil delivery The pump begins to operate very fast without delivering oil The pump keeps on operating although the oil outlet is closed Oil leaks out through the air outlet muffler (14). Air leaks out through the air outlet muffler (14). Decrease of the oil delivery Not enough air pressure Some outlet line component is clogged or closed The drum is empty Oil level is beneath the suction tube inlet There is an oil leakage in some point of the outlet circuit Contamination in the upper valve (23) or foot valve (37) Oil has by-passed to the air motor caused by worn or dam aged packing set 3. 4. The air piston o-ring is worn or damaged (4). The air motor cylinder is scratched (3). The upper part of the central bar is damaged or scratched (6). The air valve mechanism is worn or damaged (5). Contamination in the upper valve (23) or foot valve (37) 5 Increase the air pressure Clean or open the outlet circuit Replace the drum Lower the suction tube Verify and tighten or repair Disassemble and clean, replace if damaged Replace the fluid packing set Disassemble and clean, replace Replace the air motor cylinder 3. Replace the central bar 4. Replace air valve mechanism Disassemble and clean, replace if damaged

Parts List Gen 1 - Lynx 3:1 Pump (made in Sweden (1) ) Description Item Number(s) Repair Kits Packing kit 4, 8, 9, 10, 16, 17, 18, 19, 21, 27 Packing Kit - 832864 Air-valve 4, 5, 10 Air Valve Kit - 832865 Central bar 6, 7, 8, 9, 10, 16, 17, 18, 19, 21 NOTE: The kits listed above are the only parts available for this pump. Air cylinder 1, 2, 3, 10 Piston kit 23, 24, 25, 26, 27, 28, 29 Foot valve 33, 34, 35, 36, 37 Pump tube 30, 31, 32 Piston rod 21x 22, 23, 24, 25, 26, 27, 28, 29 Air filter kit 11, 12, 13, 14 833346 Bung adapter 20 4411-022S 1 2 3 8 9 10 21 22 21 23 11 12 24 4 5 25 26 27 28 29 13 14 30 15 31 6 16 17 18 19 32 33 34 7 35 36 20 37 Included in 832865 repair kit Included in 832864 repair kit 6 (1) Identified on pump label

Parts List Gen 2 - Lynx 3:1 Pump (made in EU (1) ) Description Item Number(s) Repair Kits Packing kit 4, 12, 13, 14, 15, 21, 22, 23, 24, 33 Packing Kit - 833111 Air-valve 4, 5, 6, 7, 8, 9, 10, 13 Air Valve Kit - 833110 Central bar 11, 12, 13, 14, 15, 21, 22, 23, 24 NOTE: The kits listed above are the Air cylinder 1, 2, 3, 13 only parts available for this pump. Piston kit 30, 31, 32, 33, 34, 35 Foot valve 39, 40, 41, 42, 43 Pump tube 36, 37, 38, 44 Piston rod 12, 28, 29, 30, 31, 32, 33, 34, 35 Air filter kit 16, 17, 18, 19 833346 Bung adapter 25, 26, 27 4411-022 Included in 833110 repair kit Included in 833111 repair kit 7 (1) Identified on pump label

For Warranty Information Visit: www.balcrank.com Balcrank Corporation 115 Reems Creek Road Weaverville, NC 28787 800-747-5300 800-763-0840 Fax www.balcrank.com SERVICE BULLETIN SB1101 Revision F 10/13 8 Revision Log: Rev. A - New release Rev. B - Added packing & air valve kits Rev C - Added cycles per gallon, noise level, wetted parts and pump curves to pg. 3 Rev D - Added note about external pressure relief Rev E - Added parts list & diagram for Gen 2 Lynx 3:1 Rev F - Added air filter kit to part lists