Bio Lion Table Top Centrifuge XC-H165

Similar documents
Bio Lion Table Top Centrifuge XC-L5

Centrifuge. Model XC-1000 Operating Manual

L550 Table-Top Low-Speed Large Capacity Centrifuge

Centrifuge. Model XC-2000 Operating Manual

Bio Lion CENTRIFUGES.

REFRIGERATED CENTRIFUGE. LRF-A2 Series

Vetlab CombiSpin Centrifuge

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

XCM12 Mini-Centrifuge

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

REFRIGERATED CENTRIFUGE. LRF-A1 Series

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

Operation Manual Supra R22

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:


OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

Operating Manual Cellspin

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

CLEMENTS. Orbital 160 Benchtop Centrifuge. CEN V 50Hz. User Manual. Manual No. CEN Issue 4

INSTRUCTION MANUAL FOR BENCH TOP CENTRIFUGE Z 200 A

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

CLEMENTS. Orbital 260 Benchtop Centrifuge. CEN V 50/60Hz. User Manual. Manual No. CEN Issue 5

Multi-Purpose, High Speed Centrifuge 1248R/1580R User s Manual

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

Centrifuge Operator / Service Manual


HIGH SPEED CENTRIFUGE

230VAC Power Inverter 400W Owner s Manual

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

Power Inverter 400 MW Owner s Manual

HIGH SPEED CENTRIFUGE

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

58kHz AM Deactivator DB104 Instruction Manual V1.0

BlueSpin Cryo. (Cat. No. BSD-CRYO)

Spectrafuge 24DMicrocentrifuge User Manual C2400 C V C V

L-K INDUSTRIES BENCHMARK S MANUAL

Z100A Clinical Centrifuge

MODEL 853VES. Model 853VES Operator s Manual. Laboratory Centrifuge IVD

Clinical, Low-Speed Centrifuge. Clinical, Low-Speed Centrifuge. Applications. 59 Order & Inquiry /

BLOOD BANK REFRIGERATED CENTRIFUGE

Installation/Operating Instructions

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Prism Microcentrifuge

Benchtop Low Speed Centrifuge. Labocon Scientific Limited

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

FD Conveyor for FD 260 Tabber

Company Profile Hunan Xiang Yi Laboratory Instrument Development Co., Ltd is high technology enterprises mainly engaged in manufacturing centrifuge

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

User s Manual. Automatic Switch-Mode Battery Charger

PrO-Cyto Centrifuges 61

MODEL 853VES Model 853VES Operator s Manual

Large Capacity, High-Speed Centrifuge

3000 SERIES DRY-BLOCK HEAT SOURCE

UTV-1200 Multi Gauge for 2008 Yamaha Rhino

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

Tissue Master. User Manual

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

USER MANUAL. CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1


Clinispin CT20 User Manual

1248/R, 1236R, 1580/R

Parts missing or damaged? Questions? Toll-free Helpline

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

Large Capacity, High-Speed Centrifuge

6L Oil-less Air Compressor 53103

Subject Underhood G System Error Codes and Symptoms System or Parts affected

HERCULES. PROCESS CONTROL VISCOMETER Model M2. User Guide

UTILITY INPUT MAINS OUTLET

ELECTRIC LIFTING HOIST

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Installation/Operating Instructions

Model : LMHS-40 Please read this manual carefully before using the instrument Labnics Equipment

Blood Centrifuge LBC-100 Series. Labocon Scientific Limited

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

Stealth Power i-tilt

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up

EBA 270 Small centrifuge

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Designed in USA, made in China by EEMB Co., Ltd. GUSTO POWER STATION USER MANUAL. LiFePO4 Battery.

Go Yonder D-Lite Owner s Manual

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

Meinzer II TM. Testing Sieve Shaker

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Refrigerated. Centrifuge.

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Model G14SD Vapor Management System

Transcription:

Bio Lion Table Top Centrifuge XC-H165 Operation Manual

Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting Page 9-10 Warranty Page 11 This operation manual is for the Model XC-HR20. To ensure safety, obtain optimum performance, and to familiarize yourself fully with use of this centrifuge, we recommend that you review this manual thoroughly before operating. Retain this operation manual in an easily accessible place near the work desk for future reference. Specification Max Speed 16500r/min Max RCF 18930 g Timer range 0~99min Speed accuracy Noise Power Dimension Weight ± 30r/min 65 db(a) 110V 60Hz 330 420 275mm 45 lbs 1

Display window see Table II Locking lid 2

Rotors (ordered separately) Table I Max Capacity Max Speed Max RCF Rotor Item # (ml tubes) (r/min) ( g) #1 Fixed Rotor A006-2 1.5/2.2ml 12 16500 r/min 18930 #2 Fixed Rotor A008-4 1.5/2.2ml 24 13200 r/min 16110 #3 Fixed Rotor A011-2 5ml 10 13000 r/min 11400 #4 Swing Rotor S003 2 48 hole 3000 r/min 1400 #5 Fixed Rotor A012-2 10ml 12 120000 r/min 14800 #6 Fixed Rotor A021-3 50ml 6 12000 r/min 13000 #6 Fixed Rotor A005 0.5ml 36 16000 r/min 23669 #7 Swing Rotor S010-2 10ml 4 6000 r/min 3200 A006-4 A008-4 A011-2 A012-2 A021-3 A024-1 S003 S010-2 3

Bio Lion Centrifuges are specially designed for clinical examination and teaching demonstrations in laboratories, colleges and medical fields. They are also ideal instruments for biological, bacteriological, pathological, and pharmaceutical research. Because of higher capability with lower price and humanized configuration design, it is an ideal choice for individuals, schools and scientific research organizations. For users: Caution!- Please read the Operation Manual first. Please verify the correct voltage and frequency of the outlet, before you plug in the unit. The Centrifuge should be controlled by the technical staff and maintained by an approved service technician. Don t use or service the centrifuge before reading the Operation Manual. Use only electrical plug supplied with the equipment. If attempting to replace fuse, make sure centrifuge is unplugged. Make sure the equipment is placed on a flat surface. This equipment is a precision instrument, always use it with care. Avoid dropping or shaking during operation. When moving the equipment, you should use both hands and set it down carefully with equal weight on all 4 corners. Do not put the equipment in direct contact with the sun. Do not expose the equipment to high temperature, damp, or dusty environment. ALWAYS make sure the centrifuge is balanced with equal weight and volume on opposite sides. The balancing weight difference should be no more than 1.5g. For fixed angle rotor, the sample volume should be less than 80% of the tubes total volume. For swing rotor, the sample volume should be less than 90% of the tubes total volume. NEVER use the following material in equipment: Flammable and explosive material. Poisonous and radioactive material. 4

This centrifuge has microprocessor control, brushless motor, real-time change of SPEED and RCF function, and a quick spin feature. In addition, it has several rotor options for the user to select (sold separately). Requirements for Installation: 1. The centrifuge should be stable with the centrifuge weight equally distributed on all 4 rubber feet. 2. Single phase alternating current, 110V/60HZ, with ground wire. DO NOT use voltage converters or extension cords. 3. Humidity level should be less than 85%. 4. There should be at least 6 (150mm) between this unit and other equipment. Table II ROTOR SPEED r/minx10 RCF TIME TEMP ACC/DEC SET ENTER RCF START STOP SET: Setup button ENTER: Confirm button in set up process RCF: Speed show in RCF SHORT: Button used for quick instantaneous spin START: Start spinning STOP / OPEN: Stop spinning / Door Open button : Up / Increase Button : Down / Decrease button Description of Display window ROTOR: SPEED/RCF: TIME: TEMP: ACC/DEC: Displays the rotor number being used Displays speed or RCF value Displays length of time centrifuge will spin Displays the temperature inside the centrifuge Displays how fast centrifuge will speed up/slow down 5

Assembly: Turning unit on 1. Insert one side of the plug into the back socket of the centrifuge. The centrifuge must be grounded. Make sure that outlet voltage is in accordance with centrifuge voltage. 2. Turn the power switch located on lower right hand side into the ON position. Set up 1. After unit is powered on push and hold STOP button. This will allow the door to open automatically. Please note door will not open if centrifuge is spinning 2. Visually inspect rotor for any flaw / weak points / or other inconsistency that may cause the rotor to fail. 3. If rotor is not installed then follow Table III and the next step. If already installed, move on to next section. 4. Put some lubricating oil (Not Included) on the motor shaft, install the rotor, washer and secure the nut cap. 5. Make sure securing nut is fastened tightly. Table III Nut Washer Rotor Motor Motor Shaft 6

Choosing the correct rotor 1. Push the SET button to adjust the rotor. The 2 digit number under the word ROTOR should be flashing. If the numbers under ROTOR are not flashing then continue to push the SET button until this happens. 2. Select your rotor by using the following chart and the or arrow buttons 01 refers to 1.5/2.2 ml 12 02 refers to 1.5/2.2 ml 24 03 refers to 5ml 10 04 refers to 2 48 hole well plates (not provided) 05 refers to 10ml 12 06 refers to 100ml 4 AND 50ml 6 07 refers to 10ml 4 3. Push ENTER to confirm. Operation: After the correct rotor has been chosen and installed (see Assembly if this has not been done) then you can add your tubes to the centrifuge. Make sure tubes are correct size and fit in the holders. Screw on the locking cap to the rotor. Press the lid down until the lid is locked and will not open. Speed Adjustment 1. Push the SET button 2 times to adjust the speed setting. The 4 digit number under the word SPEED / RCF should be flashing. If the numbers under SPEED / RCF are not flashing then continue to push the SET button until this happens. 2. NOTE speed increments are X 10. For example if you set the speed in the display to 2000, this really means 20,000 RPM s. If you set the display to 350 then this is 3,500 RPM s 3. This centrifuge default setting for speed is in RPM s. Please select desired speed (shown in RPM s) by using the or arrow buttons. If you would rather adjust speed setting based on RCF values, then push the RCF button to the right of the display window. This will convert RPM into RCF values. 4. Push ENTER to confirm. Time Adjustment 1. Push the SET button 3 times to adjust the time setting. The 2 digit number under the word TIME should be flashing. If the numbers under TIME are not flashing then continue to push the SET button until this happens. 2. Select your desired time (in minutes) using the or arrow buttons. You can set the time from 1 99 minutes. 7

3. Push ENTER to confirm. 4. If you prefer to run the centrifuge for time less than 1 minute then you can hold the SHORT button down for this time frame. By holding the SHORT button down the centrifuge will run at your desired speed until you release this button. Temperature Adjustment 1. Push the SET button 4 times to adjust the temperature setting. The 3 digit number under the word TEMP should be flashing. If the numbers under TEMP are not flashing then continue to push the SET button until this happens. 2. Select your desired temperature (in degrees Celcius) using the or arrow buttons. You can set the temperature from -20ºC to 40ºC. 3. Push ENTER to confirm. Acceleration Adjustment 1. Push the SET button 5 times to adjust the acceleration setting. The 1 digit number under the word ACC should be flashing. If the number under ACC is not flashing then continue to push the SET button until this happens. 2. Select your desired acceleration setting using the or arrow buttons. 0 is the FASTEST acceleration setting and 9 is the SLOWEST acceleration setting. 3. Push ENTER to confirm. Deceleration Adjustment 1. Push the SET button 6 times to adjust the deceleration setting. The 1 digit number under the word DEC should be flashing. If the number under DEC is not flashing then continue to push the SET button until this happens. 2. Select your desired deceleration setting using the or arrow buttons. 0 is the FASTEST deceleration setting and 9 is the SLOWEST deceleration setting. 3. Push ENTER to confirm. Spinning Centrifuge Now that the correct rotor is selected and your desired speed, time, temperature and acceleration / deceleration setting are set you can now run your samples. 1. Make sure lid is closed and locked. 2. Press the START button. 3. After the centrifuge has run for the desired amount of time (when the timer gets down to 0 ) then the centrifuge will slow down. Please note that the speed must reach 0, before you can open the door. 4. When speed reaches 0 the door will open automatically and beep to indicate it has completed the spin. 8

Note This centrifuge has an electronic lock feature. If the unit is unplugged, needs to be opened during a power outage, or for any other reason the lid can not be opened, please insert the emergency lid release tool (looks similar to a screw driver and included with centrifuge) into the lid release on the side (shown below) and open the lid. Emergency hole Maintenance 1. Periodically clean the inside and outside of centrifuge with a lint free cloth. 2. Do not use any caustic cleaning liquids inside centrifuge. 3. Check the rotor before every use. 4. Please turn off and unplug the centrifuge if it is not regularly used. 9

Trouble Shooting: Error Messages Table IV Display E1 E2 E3 E4 E5 E7 E8 E9 Failure Imbalance Over speed Temperature Senor Electronic plate Motor Error Poor Contact Setup Error Transformer E1 - Imbalance: The weights of the tubes are not equally balanced. Error message can occur if weight is over 1.5 grams Rotor is not installed or spinning correctly Bent or damaged motor shaft. Solutions: Make sure the tubes are equally balanced as described in the Caution section. If it is the Rotor, please double check that everything is assembled correctly as described in TABLE III. If there is any damage, please report to your dealer. E2 - Over speed: Power supply isn t correct. Failing speed sensor Solutions: Check to make sure the voltage and frequency of your outlet are correct, if not, unplug immediately. For any failing equipment, please report to your dealer. E3 Temperature Sensor: Not cooling centrifuge to desired Temperature. Solutions: Contact your authorized dealer. E4 - Electronic plate failure: Failed electronic plate. Solutions: Check out to insure the plug is in good working condition. A failed Electronic plate needs to be replaced. Please report to your dealer. E5 - Motor failure: The connecting line between motor and electronic plate is loose. Motor has failed. Solutions: These failures should be fixed by a professional. Please report to your dealer. E8 - Setup failure: Solutions: Reset the setting in assembly and operation part of manual. Display is not working Unit is not turned on. Check for secure connection of the power cord at the unit back and at the power outlet. Blown fuse, please report to your dealer. 10

Upon receipt of your new Bio Lion centrifuge we recommend you record the following information for future reference: Date purchased/received: Bio Lion Dealer: Dealer s phone number: Warranty The manufacturer warrants this instrument to be free from defects in material and workmanship under normal use for 1 year from the date of purchase. It does not cover damage resulting from abuse or misuse, repairs or alterations performed by unauthorized repair technicians, or damage occurring in transit. If you have questions concerning this product or warranty, contact the dealer from whom it was purchased. For warranty service, centrifuge should be well packed to avoid damage in transit, preferably in original box and packing. Include your complete return address and telephone number as well as a description of the difficulty, date and place of purchase, and ship to the address below. If under warranty it will be repaired or replaced at no charge and returned. If misuse, alterations, accident or abnormal conditions of operation caused failure, an estimate for repairs will be provided for your approval prior to work being performed. Centrifuge Service Department 7241 Gabe Court Manassas, VA 20109-2434 Bio Lion Centrifuges www.bio-lion.com 11