ST-50 SERIES ULTRASONIC TRANSDUCER

Similar documents
ST-H SENSOR. Instruction Manual PL-527 January Rev. 1.6

MSL BELT SCALE. Instruction Manual PL-424. February PRR - 1.0

MSI SINGLE IDLER BELT SCALE

ILE - 37 Sensing Head Instruction Manual PL-374 July 1998

Level Measurement Products Installation Considerations-Ultrasonic

1' to 10' deep and 1' to 25' deep

Ultrasonic Non Contact Sensors

ILE - 61 SENSING HEAD

Autoweigh Feeder Series 400 A New Generation of Weigh Feeders

MILLTRONICS UNIVERSAL SCALE NIVERSAL SCALE Rev. 1.2

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

Instruction Manual December milltronics RBSS

MSI SINGLE IDLER BELT SCALE

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

Syntron Pneumatic Vibrators

Autoweigh Feeder Series 600. A New Generation of Weigh Feeders

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

MAIN FUNCTION FEATURES. . D = v t /2

INSTALLATION GUIDE Ultrasonic Sensors Series UX micro

Instruction Manual August milltronics MMI BELT SCALE

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Instruction Manual September milltronics A SERIES

Instruction Manual August milltronics MSI BELT SCALE

PROCAP Capacitance Level Sensors

Instruction Manual May milltronics MWL WEIGHT LIFTER

MMI-2, 2 IDLER BELT SCALE

Instruction Manual March ile-37 SENSING HEAD

AUTOWEIGH FEEDER SERIES 400

Model DFX Doppler ultrasonic flow meter

PROCAP Capacitance Level Sensors

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Ultrasonic Two-Wire Point Level Control

INTRODUCTION / TABLE OF CONTENTS

SUPERPROX Ultrasonic Proximity Sensors

SURVIVOR Paramounts HE Medium-Capacity Weigh Module Systems

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

ILE-61 SENSING HEAD. Instruction Manual PL-376. November 2001

AUTOWEIGH FEEDER SERIES 1200/3600 Instruction Manual PL-588 October 1999

QUICKSTART. Quickstart. A higher level of performance

C7170A,B Encapsulated Temperature Sensor

Installation and Operating Manual

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

LTX RF LEVEL SENSOR. Instruction Manual

CAPACITANCE LEVEL SWITCH

AUTOWEIGH FEEDER SERIES 600

OWNER S GUIDE & INSTALLATION INSTRUCTIONS

USER S GUIDE. Installation & Operation Instructions. Level Indicating Transmitter Model LIT25 Manual Series 3.3

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing

Instruction Manual July milltronics MMI BELT SCALE

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

MAIN FUNCTION FEATURES. . D = v t /2

Bend Pulleys. Instruction Manual PL-333 June Rev 2.2

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Low Profile Insertion Vortex

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Installation manual. Cooling system. Industrial engines DC09, DC13, DC16 OC16. 01:05 Issue 12 en-gb. Scania CV AB 2018, Sweden


Efficient sealing. Key benefits. - Minimises false air intake. - Fast return on investment due to reduced power consumption

Rotary blade level indicators Level limit switches for bulk goods. Accessories

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

ULTRASONIC EXAMINATION

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Ultrasonic Inspection Equipment for Al-Fin Insert Diesel Pistons

Bin Activators. Bin Activators. Bin Unloaders PLBB (LVT) Posibin MLB Live Bin Self Standing Static Bin/Hopper

Solids Flowmeters. Continuous In-Line Weighing

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Just Level. Table of Contents. Model CPH Capacitive Proximity Switch TECHNICAL INFORMATION. Principle of Operation 2. Applications 3.

Super-Safe-Plus Roto-Bin-Dicator

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

Safety Instructions. Series 3 E. for Installation, Operation and Maintenance of ABO Buteerfly Valves

Point level measurement Capacitance switches

UTM10 Series Ultrasonic Transit-time Flowmeters

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

PRO REMOTE 25 LV CAPACITANCE PROBE

PRO REMOTE Series CAPACITANCE PROBE

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Weigh modules Tank and hopper kits

SIGNET 7002 Vortex Flow Sensor ENGLISH

Industrial Mini Vent Sets

Weigh Modules. Section Contents

BEST MANAGEMENT PRODUCTS, INC. The SNOUT INSTALLATION INSTRUCTIONS U.S. Patent # Canadian Patent #

ETF-600 Sensor Operated Lavatory Faucet

M5200 Industrial Pressure Transducer

Tidal Series 5. Level Control For Dry Bulk Materials

Tips for Installation, Calibration and Operation of SmartSwitch Tank Management Systems. Contents: Page

EchoSonic. LU23, LU27, LU28 & LU29 Series Manual. Ultrasonic Liquid Level Transmitter

Sludge Blanket Level Measurement

TS Series TS Series

ELECTRICAL INSTALLATION

Horizontal Pre-Piped Bladder Tanks with Proportioner

Level Measurement Continuous level measurement - Radar transmitters

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

MWL Milltronics Weight Lifter. Instruction Manual June 2001

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Mini-Roto TM Paddle Wheel Installation & Operation Manual

Vertical Pre-Piped Bladder Tanks with Proportioner

Transcription:

ST-50 SERIES ULTRASONIC TRANSDUCER Instruction Manual PL-418 December 1994 33454180 Rev 1.2

Thank you for purchasing Milltronics products. We endeavour to design equipment that is simple to use and reliable in its operation, with the aim of satisfying our customers needs. Milltronics has been designing and manufacturing process equipment since 1954. Our fields of expertise include ultrasonic level measurement, in-line weighing of dry bulk solids and motion sensing. Milltronics is established world wide through associate offices and representatives. Our network is continually being refined to provide our customers with first rate sales information, engineering assistance and after sales support. For more details on our products and service, please contact us and we will provide you with a listing of the offices or representatives nearest you. P.O. Box 4225 730 The Kingsway Peterborough, ON Canada K9J 7B1 709 Stadium Drive Arlington, Texas U.S.A. 76011 Oak House Everoak Estate Bromyard Road Worcester, WR2-5HP England Château de la Saurine Pont de Bayeux B.P. 6 13590 Meyreuil Aix en Provence France Tel. (705) 745-2431 Fax (705) 745-0414 Tel. (817) 277-3543 Fax (817) 277-3894 Tel. (01905)748404 Fax (01905) 748430 Tel. 42.65.69.00 Fax 42.58.63.95

ABOUT THE TRANSDUCER The ST-50 series of s operates in association with Milltronics ultrasonic level monitoring products. The converts the electrical energy of the face transmit pulse from the transceiver into acoustical energy. It then converts the acoustical energy of the echo back into electrical energy for the transceiver receive period. The effective acoustical energy is generated from the face and is radiated outward, decreasing in amplitude at a rate inversely proportional to the square of the distance. Maximum power is radiated axially (perpendicular) from the face in a line referred to as the axis of transmission. Where power is reduced by half ( 3 db), a conical boundary defining the sound beam, centered about the axis of transmission is established. The diametric measurement of the cone in degrees defines the beam angle. Impedance matching techniques are used to optimize the transfer of power from the into air and from the air back into the. 3 db boundary 5 beam angle axis of transmission, perpendicular to face SPECIFICATIONS Model : Measurement range : Temperature range : Frequency :» ST-50» typically 0.3 m -15 m (1-50 ft) restricted to transceiver maximum» 40 to 93 C ( 40 to 200 F)» typically 44 KHz, transceiver dependent Beam angle :» 5 Weight * : Construction : Separation : Approvals :» 3.9 Kg (8.5 lb)» CPVC housing with polyurethane face» 1" NPT mounting/conduit connection with neoprene jacketed cable» totally encapsulated» options:» flanging: the can be factory flanged, consult Milltronics» facing:» CPVC for corrosive applications» Teflon for corrosive applications» polyethylene foam for dry-dust applications» typically 365 m (1200 ft) from associated transceiver» CSA, FM and BASEEFA / CENELEC * approximate shipping weight of with standard cable length and unflanged refer to associated transceiver manual the maximum temperature for polyethylene foam facing is 77 C (170 F) Teflon is a registered trade mark of Dupont PL-418 1 95/07/11

OUTLINE AND CONNECTION *Cable length:» standard: 5 m (16 ft)» optional: consult Milltronics cable*, PVC jacket black white junction box hot Milltronics transceiver S H I H E O L T D 1" NPT shield RG62 A/U coaxial cable OR black white 125 mm (4.9") direct connection shield CPVC housing 140 mm (5.5") dia. radiating surface (see Specification \ Construction) DO S AND DON TS VERY IMPORTANT Do not route cable openly in raceways. For optimum isolation against electrical noise, run cable in a grounded metal conduit with no other cabling (except temperature sensor). Ground shield only at transceiver. Insulate shield at junctions to prevent inadvertent grounding. Transducer wiring must be done in conjunction with approved conduit, boxes and fittings and to procedures in accordance with all governing regulations. Seal all thread connections to prevent ingress of moisture. Do not run cable near high voltage or current runs, contactors and SCR control drives. For BASEEFA Zone 0, cable must be terminated externally to Zone 0 in an appropriate manner. The cable must be protected against mechanical damage, and arrangements sealed to prevent migration of atmosphere from zone 0. To reduce risk of elecrostatic discharge, housing (except free) must be covered with copper mesh and grounded. PL-418 2 96/03/19

MOUNTING DO S AND DON TS VERY IMPORTANT Mount the so that it is above the maximum material level by at least the blanking value. Refer to the associated transceiver manual. Do not mount the directly to metal. Use a PVC coupling and nipple as provided. Do not overtighten mounting. Hand tightening of the mounting hardware is sufficient. On liquid applications, the must be mounted so that the axis of transmission is perpendicular to the liquid surface. Avoid aiming into vortexes. On solids applications, the Milltronics Easy Aimer should be used to facilitate aiming of the. Refer to the Easy Aimer instruction manual. Where the is mounted to a standpipe, the inner standpipe surface and end must be smooth and free of burrs, ridges and seams. Consider the optional temperature sensor when mounting the. MOUNTING - LIQUID APPLICATIONS Flexible Conduit Bracket flexible conduit steel channel 1" NPT coupling Flexible conduit mounted should not be subjected to wind, vibration or jarring. PL-418 3

MOUNTING - LIQUID APPLICATIONS (cont d) Blind Flange Flanged 1" NPT nipple welded to blind flange factory assembled flanged 1" NPT coupling bolt gasket nut FLAT FACE FLANGE ONLY 1" NPT coupling Flange, gasket and hardware supplied by customer. Refer to Liquid \ Applications - Standpipes. Customer flanged standpipe. If metal flange must be welded to pipe, refer to Liquid\ Applications - Standpipes. MOUNTING - SOLIDS APPLICATIONS Optional Easy Aimer Kit Easy Aimer Kit In solids applications, the should be mounted so that it is aimed toward the low level draw point. To facilitate this mounting, it is suggested that the optional Milltronics Easy Aimer Kit be used. Refer to the Easy Aimer instruction manual. PL-418 4

APPLICATIONS LIQUID APPLICATIONS - STANDPIPES In many applications, access must be made via a standpipe. In such cases, Milltronics can provide flange mounted s that will readily mate to the flanged standpipe. Another option is to hang the from a blind flange. The standpipe length should be as short and the diameter as large as possible. As a rule of thumb, the 3 db cone of the sound beam should not intersect the standpipe wall in applications opening into a vessel or larger area. Otherwise, additional blanking will be required to compensate for the interference zone created by the opening. no additional blanking flanged no intersection vessel no vessel additional blanking sound beam intersects vessel reflection at interference zone created by opening near blanking extension of 150 mm (6") past end of standpipe may be required PL-418 5

LIQUID APPLICATIONS - VOLUME "Alternate" "Preferred" "Bad" tank manufacturer s full level 5 beam angle span: corresponds to tank manufacturer s empty level rise run Empty level for "alternate" location. Below this level, echo would reflect away from the. tank manufacturer s empty level discharge 1. Beam should not detect bin bottom. If this occurs use range extension parameters (on transceivers where available) to omit false echoes. A 5 beam angle represents a rise : run of about 20 : 1. In most tanks, the should be centered as much as possible (without interference from inlet) for optimum reading range. 2. Sound beam must be perpendicular to liquid surface. If standpipe is used, refer to Liquid Applications - Standpipes. 3. Echo has missed improperly leveled. 4. When performing an empty or full calibration, the tank must contain its normal vapour and be at its normal temperature. PL-418 6

SOLIDS APPLICATIONS - TYPICAL Easy Aimer bin wall seams filling profile emptying profile 1. Transducer angled to avoid seams in bin wall and aimed at discharge in order to read bin when empty. 3. Transducer too close to material inlet. Falling material will intersect sound beam and cause erroneous readings or loss of echo. 2. Avoid intersecting bin wall seams, structural members and wall irregularities. Otherwise, refer to transceiver manual. minimal angle of repose discharge 4. On fluid like solids, aim perpendicular to material surface. 5. On dual discharge bins, aim each at the discharge point. PL-418 7

SOLIDS APPLICATIONS - SPECIAL STORAGE BIN WITH AGITATOR infeed agitator 1. Transducer should be kept away from infeed. 2. Where agitators are in use, use the Agitator Discrimination parameter on transceivers where available. 3. Transducer should be aimed away from wall projections. drag conveyor DRYER - WOOD CHIPS infeed typical low level typical high level 1. Transducer should be mounted perpendicular to slope of wood chips. PL-418 8